Search NASA⌕ Search

SEARCH · Search NASA

Results for “Session detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

FT-01: Autonomous Helicopter Flight Testing Over Long Island Sound Special Session - Hazard Perception and Avoidance Tech Area

This presentation is included as part of a panel reporting on the Integration of Automated Systems (IAS) flight test series. The IAS series concluded in October 2023 and was conducted under NASA’s Advanced Air Mobility project and in partnership with Sikorsky and the Defense Advanced Research Projects Agency (DARPA). The flight test effort included two crewed rotorcraft platforms. The first, a modified S-76B helicopter, served as the “ownship” for the duration of the flight test. The second vehicle, a modified S-70, served as the intruder aircraft. One Sikorsky pilot and one NASA test pilot was onboard each aircraft for every test point, with the NASA test pilot responsible for interacting with the research systems under test. This portion of the panel presentation focuses on the results of the flight test that assessed the Federal Aviation Administration’s (FAA) next-generation collision avoidance system, the Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr). The two configurations available within ACAS Xr – the Collision Avoidance System (CAS) configuration and the Detect and Avoid (DAA) configuration – were flown with an onboard pilot under Visual Flight Rules in controlled airspace over the Long Island Sound (Connecticut, USA). A total of 33 flight test cards were flown with ACAS Xr active. Results showed that the ACAS Xr alerting and guidance was largely effective and rated positively by the NASA test pilots, exemplified by zero instances of the pilots overriding an ACAS Xr Resolution Advisory (RA). Key areas of improvement, however, were noted, particularly with regards to the lack of an aural alert indicating a need to accelerate when receiving an RA at low speed and the occurrence of multiple RAs that the pilots found to be unacceptable.

detect and avoid↗

Skeletal Adaptations to Different Levels of Eccentric Resistance Following Eight Weeks of Training

Coupled concentric-eccentric resistive exercise maintains bone mineral density (BMD) during bed rest and aging. PURPOSE: We hypothesized that 8 wks of lower body resistive exercise training with higher ratios of eccentric to concentric loading would enhance hip and lumbar BMD. METHODS: Forty untrained male volunteers (34.9+/-7.0 yrs, 80.9+/-9.8 kg, 178.2+/-7.1 cm; mean+/-SD) were matched for leg press (LP) 1-Repetition Maximum (1-RM) strength and randomly assigned to one of 5 training groups. Concentric load (% 1-RM) was constant across groups, but each group trained with different levels of eccentric load (0, 33, 66, 100, or 138% of concentric) for all training sessions. Subjects performed a periodized supine LP and heel raise (HR) training program 3 d wk-1 for 8 wks using a modified Agaton Fitness System (Agaton Fitness AB, Boden, Sweden). Hip and lumbar BMD (g/sq cm) was measured in triplicate pre- and post-training using DXA (Hologic Discovery ). Pre- and post-training means were compared using the appropriate ANOVA and Tukey's post hoc tests. Within group pre- to post-training BMD was compared using paired t-tests with a Bonferroni adjustment. RESULTS: There was a main effect of training on L1, L2, L3, L4, total lumbar, and greater trochanter BMD, but there were no differences between groups. CONCLUSION: Eights wks of lower body resistive exercise increased greater trochanter and lumbar BMD. Inability to detect group differences may have been influenced by a potentially osteogenic vibration associated with device operation in the 0, 33, and 66% groups.

English, Kirk L.↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Methods and Applications of 3D Radiochromic Dosimetry

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-03: Real-Time Volumetric Scintillation Dosimetry for Radiation Therapy

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: Cherenkov Imaging for Radiation Therapy Dose Verification On Patients

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

Evaluating the feasibility of LA-ICP-TOF-MS for the analysis of environmental particle collections

Laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) was employed to rapidly analyze environmental particle samples collected using aerosol contaminate extractors (ACE). The ACE particle collectors were placed at various distances (0.5, 1.3, and 4.5 km) from a source that released Ru-bearing particles. Samples for measurement were then generated (as sub-samples) from the ACE collection plates via particle “lift off” with gunshot residue (GSR) tabs. The LA-ICP-TOF-MS method was employed such that 10+ samples could be analyzed in a single unattended analytical session. A 3 × 1 mm area of individual GSR tab samples were analyzed in less than 30 minutes. This provided spatially resolved elemental and isotopic measurements of the particulate content and confirmed the presence of Ru-bearing particles within the complex background environmental particle loading. As anticipated, measurements showed collectors closest to the source had the highest concentration of the released Ru-bearing particles, while all collectors, regardless of distance, contained similar levels of background particles (e.g., Fe and Sr). Sequential scanning electron microscopy – automated particle analysis (SEM-APA) and LA-ICP-TOF-MS analysis was employed for method validation and a demonstration of the multi-modal approach. The same 2-dimensional region was analyzed by both methods and the particles identified via SEM-APA were also detected using LA-ICP-TOF-MS, with 100% accuracy. Overall, LA-ICP-TOF-MS demonstrated its utility for rapid elemental and isotopic particle analysis from environmental air samples.

Manard, Benjamin T. [Oak Ridge National Laboratory↗

Panel Discussion: Life in the Cosmos

Water appears to be essential to all life on Earth. For this reason, "Follow the Water" has been adopted as a mantra for the search for Life in the Cosmos. Expeditions have helped to establish the limits and biodiversity of life in the most extreme environments on Earth. Microbial extremophiles inhabit acidic streams; hypersaline and hyperalkaline lakes and pools; the cold deep sea floor, permafrost, rocks, glaciers, and perennially ice-covered lakes of the polar environments; geysers, volcanic fumaroles, hydrothermal vents and hot rocks deep within the Earth's crust. The ESA Venus Express Spacecraft entered Venusian Orbit in 2006 and continues to produce exciting results. The Visible and Infrared Thermal Imaging Spectrometer (VIRTIS) instrument made the first detection of hydroxyl in the atmosphere of Venus, indicating it is much more similar to Earth and Mars than previously thought. Huge hurricane-like vortices have been found above the poles of the planet and as yet unidentified UV absorbers that form mysterious dark bands in the upper atmosphere. At 70 km and below, water vapor and sulfur dioxide combine to form sulfuric acid droplets that create a haze above the cloud tops. Thermophilic acidophiles, such as have recently been discovered on Earth, could possibly survive in the hot sulfuric acid droplets that exist in the upper atmosphere of Venus. In order to understand how to search for life elsewhere in the Solar System, over 40 VIRTIS images of Earth from Venus have been obtained to search for evidence of life on Earth. The signatures of water and molecular Oxygen were detected in the Earth s atmosphere, but the atmosphere of Venus also exhibits these signatures. The water and water ice are far more abundant on comet, the polar caps and permafrost of Mars and the icy moons of Jupiter and Saturn. These "frozen worlds" of our Solar System, are much more promising regimes where extant or extinct microbial life may exist. The ESA Mars Advanced Radar for Subsurface and Ionospheric Sounding (MARSIS) probe has found that both the North and South Polar Caps of Mars are approximately 3.5 km thick and are composed almost entirely of water ice. In winter, a thin dry ice layer covers the caps, but it sublimates directly to CO2 in the spring. The ESA Mars Express Orbiter images reveal Rupes Tenuis to be a vast snow-laden region on the southern edge of the Martian North Polar Cap. The Mars Exploration Rover Spirit found alkaline volcanic rocks in the Gusev Crater and the Phoenix Mars Lander has shown that the soil of Mars is much more alkaline than previously expected. The Phoenix Mars Lander has also made direct observations of frozen and liquid water on Mars. It is known that microorganisms from Alaska, Siberia and Antarctica can remain alive frozen in permafrost or ice for long periods of time. These discoveries increase the possibility that the Labeled Release Experiment may have discovered life on Mars during the Viking Mission and provide strong impetus for the return of life detection experiments to Mars. Changes in the spin rate of Saturn's moon Titan indicate that it may also harbor a 300 km thick liquid water ocean beneath its icy crust. The NASA/ESA/Italian Space Agency Cassini Spacecraft has imaged geysers containing water vapor, methane, carbon dioxide and organics erupting from the "tiger stripe" regions near the South Pole of Saturn's moon Enceladus. The high temperatures observed, the water vapor and large number of ice particles expelled suggest that a liquid water lake may exist beneath the "tiger stripe" ice cracks of Enceladus. The NASA Deep Impact probe found the surface temperature of comet 9P/Temple 1 at 1.5 AY was slightly above the ice/water phase change temperature (273 K). This suggests melting of water ice near the comet surface. A spectrometer the spacecraft detected a mixture of clay and carbonate minerals (that form in the presence of liquid water) streaming off the comet after the collision with the pactor. The study of chemical and mineral biomarkers, chiral amino acids and possible indigenous microfossils in SNC and carbonaceous meteorites continues. These results suggest that comets should be considered prime targets in the search for Life in the Cosmos. The ESA Rosetta mission is on track to rendezvous with comet 67P/Churyumov-Gerasimenko. The recent space observations combined with new information about the ability of microbial extremophiles to thrive in polar environments suggest that life may be far more widely distributed in the Cosmos than previously thought possible. The Panelists will review recent discoveries and provide their own insights about Life in the Cosmos -- followed by a question and answer session with the audience.

Hoover, Richard B.↗

The Radio Fundamental Catalogue. I. Astrometry

We present the all-sky catalogue of absolute positions and estimates of correlated flux density of 21,942 compact radio sources determined from processing interferometric visibility data of virtually all VLBI observing sessions at 2 to 23~GHz from 72 programs suitable for absolute astrometry collected for 30 years. We used a novel technique of generation of a dataset of fused observables that allowed us to incorporate all available data in our analysis. The catalogue is the most complete and most precise to date. It forms the foundation and reference for positional astronomy, space geodesy, space navigation, population analysis of active galactic nuclei (AGNs), and provides calibrators for phase-referencing for differential astrometry and VLBI astrophysical observations. Its accuracy was evaluated through a detailed accounting systematic errors, rigorous decimation tests, comparison of different datasets, and comparison with other catalogues. The catalogue samples preferentially the AGNs with a strong contemporary parsec-scale synchrotron emission. Its milliarcsecond level positional accuracy allows association of these AGNs with detections in a wide range of the electromagnetic spectrum from low-frequency radio to gamma-rays and high energy neutrinos. We describe the innovative data processing and calibration technique in full detail, report the in depth analysis of random and systematic positional errors, and provide the list of associations with large surveys at different wavelengths.

Astronomy↗

Clinical evaluation of a medical high dynamic range display

Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.09% of difference. For the difficult nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 1.38% of difference. The averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in function of the local average luminance around the nodules. For the lowest luminance range, there is more than 30% in favor of the HDR display. For the highest luminance range, there is less than 6% in favor of the LDR display. Conclusions: This study shows the potential benefit of using a HDR display in radiology.

60 APPLIED LIFE SCIENCES↗

MO-E-9A-01: Risk Based Quality Management: TG100 In Action

One of the goals of quality management in radiation therapy is to gain high confidence that patients will receive the prescribed treatment correctly. To accomplish these goals professional societies such as the American Association of Physicists in Medicine (AAPM) has published many quality assurance (QA), quality control (QC), and quality management (QM) guidance documents. In general, the recommendations provided in these documents have emphasized on performing device-specific QA at the expense of process flow and protection of the patient against catastrophic errors. Analyses of radiation therapy incidents find that they are most often caused by flaws in the overall therapy process, from initial consult through final treatment, than by isolated hardware or computer failures detectable by traditional physics QA. This challenge is shared by many intrinsically hazardous industries. Risk assessment tools and analysis techniques have been developed to define, identify, and eliminate known and/or potential failures, problems, or errors, from a system, process and/or service before they reach the customer. These include, but are not limited to, process mapping, failure modes and effects analysis (FMEA), fault tree analysis (FTA), and establishment of a quality management program that best avoids the faults and risks that have been identified in the overall process. These tools can be easily adapted to radiation therapy practices because of their simplicity and effectiveness to provide efficient ways to enhance the safety and quality of treatment processes. Task group 100 (TG100) of AAPM has developed a risk-based quality management program that uses these tools. This session will be devoted to a discussion of these tools and how these tools can be used in a given radiotherapy clinic to develop a risk based QM program. Learning Objectives: Learn how to design a process map for a radiotherapy process. Learn how to perform a FMEA analysis for a given process. Learn what Fault tree analysis is all about. Learn how to design a quality management program based upon the information obtained from process mapping, FMEA and FTA.

60 APPLIED LIFE SCIENCES↗

New Developments in FPGA: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

hardware description language (HDL)↗

CodeScribe Agent

SF-26-086 CodeScribe introduces a structured, multi-stage pipeline that combines deterministic program analysis with LLM-powered translation to enable incremental, testable Fortran-to-C++ migration. First, `code-scribe index` traverses the project directory tree and produces `scribe.yaml` metadata files recording all modules, subroutines, and functions at each level, giving the LLM accurate structural context instead of a hallucinated codebase model. Second, `code-scribe draft` performs the deterministic portion of translation — converting Fortran types to C++ equivalents, replacing `use` statements with `#include` and `using namespace` directives, and detecting constructs requiring special handling — while embedding`scribe-prompt` annotations that guide the LLM through non-trivial cases such as statement-function-to-lambda conversions and `extern "C"` wrapper generation. Third, `code-scribe translate` applies project-specific TOML-based few-shot prompt templates and submits the composed prompt to a pluggable LLM backend (OpenAI, Anthropic, Argonne ARGO, any OpenAI-compatible endpoint, or local Hugging Face checkpoints), producing a C++ source file, a header, and a Fortran-C++ interface file for each translated routine so the codebase compiles and runs correctly throughout the migration. Beyond translation, CodeScribe includes a tool-using coding agent (`code-scribe agent`) with read, bash, edit, and write capabilities, and a bounded loop mode (`code-scribe loop`) that runs repeated stateless agent sessions over a task file with restricted tool access — enabling sustained, auditable software development workflows for broader scientific computing tasks.

Dhruv, Akash [Argonne National Laboratory (ANL), A↗

[EUV Spectroscopy of MrK 421]

In accordance with our proposal, we carried out and analyzed a successful Extreme Ultraviolet Explorer spectroscopic observation of the BL Lacertae object Mrk 421 in April/May 1995 (approx. 242 ksec useful time). During this period, the source underwent a flare that was detected also in simultaneous observations in the X-ray and TeV (gamma)ray energy bands. Our EUVE data, however, provided the best continuous coverage of the flare and therefore played a key role in the analysis of the multiwavelength observation campaign (Buckley et al. 1996). Our spectral analysis benefited from an efficient procedure that we employed for properly assessing the background contamination at the shortest wavelengths. As a result, we were able to identify strong absorption features at the shortest observed EUV wavelengths (approx. 65-75 A), which were missed in earlier, on axis EUVE observations that extended only down to approx. 75 A (Fruscione et al. 1996). Our observations and interpretation of Mrk 421 were described in Kartje et al. 1997 (see attached reprint). The results were also presented in a poster at the AGN session in the 18th Texas Symposium on Relativistic Astrophysicsheld (Chicago, December 1996). Our interpretation of the observations has formed the basis for a unified model of outflows in BL Lac objects and Broad Absorption Line QSOs (Kartje & Konigl 1997). Preliminary accounts of this work, which have included a description of the EUVE observations of BL Lac objects, were presented in posters in IAU Colloquium No. 163 on Accretion Phenomena and Associated Outflows (Port Douglas, July 1996) and in the Carnegie Observatories Workshop on Ejection of Matter from AGNs (Pasadena, February 1997).

Koenigl, Arieh↗

The CCSDS Next Generation Space Data Link Protocol (NGSLP)

The CCSDS space link protocols i.e., Telemetry (TM), Telecommand (TC), Advanced Orbiting Systems (AOS) were developed in the early growth period of the space program. They were designed to meet the needs of the early missions, be compatible with the available technology and focused on the specific link environments. Digital technology was in its infancy and spacecraft power and mass issues enforced severe constraints on flight implementations. Therefore the Telecommand protocol was designed around a simple Bose, Hocquenghem, Chaudhuri (BCH) code that provided little coding gain and limited error detection but was relatively simple to decode on board. The infusion of the concatenated Convolutional and Reed-Solomon codes5 for telemetry was a major milestone and transformed telemetry applications by providing them the ability to more efficiently utilize the telemetry link and its ability to deliver user data. The ability to significantly lower the error rates on the telemetry links enabled the use of packet telemetry and data compression. The infusion of the high performance codes for telemetry was enabled by the advent of digital processing, but it was limited to earth based systems supporting telemetry. The latest CCSDS space link protocol, Proximity-1 was developed in early 2000 to meet the needs of short-range, bi-directional, fixed or mobile radio links characterized by short time delays, moderate but not weak signals, and short independent sessions. Proximity-1 has been successfully deployed on both NASA and ESA missions at Mars and is planned to be utilized by all Mars missions in development. A new age has arisen, one that now provides the means to perform advanced digital processing in spacecraft systems enabling the use of improved transponders, digital correlators, and high performance forward error correcting codes for all communications links. Flight transponders utilizing digital technology have emerged and can efficiently provide the means to make the next leap in performance for space link communications. Field Programmable Gate Arrays (FPGAs) provide the capability to incorporate high performance forward error correcting codes implemented within software transponders providing improved performance in data transfer, ranging, link security, and time correlation. Given these synergistic technological breakthroughs, the time has come to take advantage of them in applying them to both on going (e.g., command, telemetry) and emerging (e.g., space link security, optical communication) space link applications. However one of the constraining factors within the Data Link Layer in realizing these performance gains is the lack of a generic transfer frame format and common supporting services amongst the existing CCSDS link layer protocols. Currently each of the four CCSDS link layer protocols (TM, TC, AOS, and Proximity-1) have unique formats and services which prohibits their reuse across the totality of all space link applications of CCSDS member space agencies. For example, Mars missions. These missions implement their proximity data link layer using the Proximity-1 frame format and the services it supports but is still required to support the direct from Earth (TC) protocols and the Direct To Earth (AOS/TM) protocols. The prime purpose of this paper, is to describe a new general purpose CCSDS Data Link layer protocol, the NGSLP that will provide the required services along with a common transfer frame format for all the CCSDS space links (ground to/from space and space to space links) targeted for emerging missions after a CCSDS agency-wide coordinated date. This paper will also describe related options that can be included for the Coding and Synchronization sub-layer of the Data Link layer to extend the capacities of the link and additionally provide an independence of the transfer frame sub-layer from the coding sublayer. This feature will provide missions the option of running either the currently performed synchronous coding and transfer frame data link or an asynchronous coding/frame data link, in which the transfer frame length is independent of the block size of the code. The benefits from the elimination of this constraint (frame synchronized to the code block) will simplify the interface between the transponder and the data handling equipment and reduce implementation costs and complexities. The benefits include: inclusion of encoders/decoders into transmitters and receivers without regard to data link protocols, providing the ability to insert latency sensitive messages into the link to support launch, landing/docking, telerobotics. and Variable Coded Modulation (VCM). In addition the ability to transfer different sized frames can provide a backup for delivering stored anomaly engineering data simultaneously with real time data, or relaying of frames from various sources onto a trunk line for delivery to Earth.

Kazz, Greg J.↗

New Developments in FPGA Devices: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

Field Programmable Gate Array (FPGA)↗

Functional brain imaging of a complex navigation task following one night of total sleep deprivation

Study Objectives: To assess the cerebral effects associated with sleep deprivation in a simulation of a complex, real-world, high-risk task. Design and Interventions: A two-week, repeated measures, cross-over experimental protocol, with counterbalanced orders of normal sleep (NS) and total sleep deprivation (TSD). Setting: Each subject underwent functional magnetic resonance imaging (fMRI) while performing a dual-joystick, 3D sensorimotor navigation task (simulated orbital docking). Scanning was performed twice per subject, once following a night of normal sleep (NS), and once following a single night of total sleep deprivation (TSD). Five runs (eight 24s docking trials each) were performed during each scanning session. Participants: Six healthy, young, right-handed volunteers (2 women; mean age 20) participated. Measurements and Results: Behavioral performance on multiple measures was comparable in the two sleep conditions. Neuroimaging results within sleep conditions revealed similar locations of peak activity for NS and TSD, including left sensorimotor cortex, left precuneus (BA 7), and right visual areas (BA 18/19). However, cerebral activation following TSD was substantially larger and exhibited higher amplitude modulations from baseline. When directly comparing NS and TSD, most regions exhibited TSD>NS activity, including multiple prefrontal cortical areas (BA 8/9,44/45,47), lateral parieto-occipital areas (BA 19/39, 40), superior temporal cortex (BA 22), and bilateral thalamus and amygdala. Only left parietal cortex (BA 7) demonstrated NS>TSD activity. Conclusions: The large network of cerebral differences between the two conditions, even with comparable behavioral performance, suggests the possibility of detecting TSD-induced stress via functional brain imaging techniques on complex tasks before stress-induced failures.

Strangman, Gary↗