Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Quantum-Well Thermophotovoltaic Cells

Thermophotovoltaic cells containing multiple quantum wells have been invented as improved means of conversion of thermal to electrical energy. The semiconductor bandgaps of the quantum wells can be tailored to be narrower than those of prior thermophotovoltaic cells, thereby enabling the cells to convert energy from longer-wavelength photons that dominate the infrared-rich spectra of typical thermal sources with which these cells would be used. Moreover, in comparison with a conventional single-junction thermophotovoltaic cell, a cell containing multiple narrow-bandgap quantum wells according to the invention can convert energy from a wider range of wavelengths. Hence, the invention increases the achievable thermal-to-electrical energy-conversion efficiency. These thermophotovoltaic cells are expected to be especially useful for extracting electrical energy from combustion, waste-heat, and nuclear sources having temperatures in the approximate range from 1,000 to 1,500 C.

Freudlich, Alex↗

Quantum Hamiltonian for the surface charge density on a ring torus and radiative decay of plasmons

Photon scattering and the ensuing excitation of surface plasmons in single rings, single composite rings, and many-ring systems was recently shown to provide dispersion and field distributions [K. V. Garapati et al., J. Phys. Commun. 2, 015031 (2018)] of potential for specific applications in particle and molecular trapping [R. Alaee et al., Appl. Phys. Lett. 109, 141102 (2016); M. Salhi et al., Phys. Rev. A 92, 033416 (2015)], in addition to metamaterials and sensing. Furthermore, following photon or electron interactions with metallic nanorings, both radiative and nonradiative decay channels are important in the consideration of the nanoparticle as a photon or phonon source, and in related applications. In this work, we quantize the electronic normal modes of the ring torus and obtain the radiative decay of plasmons. Due to a geometry-related complexity, we employ a perturbation approach to obtain analytical expressions for the radiative decay channel for a vacuum bounded single solid nanoring. In quantizing the fields, the frequency spectrum of the charge density normal modes of the nanoring is obtained and shown to agree with the exact quasistatic plasmon dispersion relations. Higher-order corrections beyond the presented zero- and first-order calculations may be obtained following the presented results. The results are of potential interest in quantum sensing such as entangling photons and plasmons, or plasmons and trapped molecules.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Searching for Dark Matter with Superconducting Qubits

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required.In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 x 10-15 in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CH(A, B-X) fluorescence from vacuum ultraviolet excitation of CH3

The fluorescence due to single-photon and two-photon excitation of CH3 produced by the reaction of CH4 with F or Cl in a flow tube is investigated experimentally. The excitation source is an excimer laser operating with pulse duration 6 nsec and repetition rate 20 Hz, and the fluorescence is observed using a 0.25-m spectrometer and a 1024-channel diode array; the results are presented graphically. Emission is detected at 157 nm (with approximate cross section 8 x 10 to the -19th sq cm) and 193 nm, but not at 248 nm. The applicability of these data to studies of hydrocarbon combustion, the methane oxidation cycle in the atmosphere, interstellar molecule formation, and diamond film fabrication is indicated.

Ye, Chao↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗

Single-distance nano-holotomography with coded apertures

High-resolution phase-contrast 3D imaging using nano-holotomography typically requires collecting multiple tomograms at varying sample-to-detector distances, usually 3 to 4. This multi-distance approach limits temporal resolution, making it impractical for operando studies. Moreover, shifting the sample complicates reconstruction, requiring precise alignment, registration, and interpolation to correct for shift-dependent magnification on the detector. In response, we propose and validate through simulations a novel, to the best of our knowledge, single-distance approach that leverages coded apertures to structure beam illumination while the sample rotates. Finally, this approach relies on a joint reconstruction scheme, which integrates phase retrieval with 3D tomography, ensuring data consistency and achieving artifact-free reconstructions from a single distance, unlocking dynamic experiments.

Nikitin, Viktor [Argonne National Laboratory (ANL)↗

An Optics Free Spectrometer for the Extreme Ultraviolet

The optics-free spectrometer is a photon spectrometer. It provides the photon spectrum of a broadband source by converting photons of energy E into electrons of energy E', according to the Einstein relation, E' = E - Ei. E, is the ionization threshold of the gas target of interest (any of the rare gases are suitable) and E is the incoming photon energy. As is evident from the above equation, only a single order spectrum is produced throughout the energy range between the first and second ionization potentials of the rare gas used. Photons with energy above the second ionization potential produce two groups of electrons, but they are readily distinguished from each other. This feature makes this device extremely useful for determining the true spectrum of a continuum source or a many line source. The principle of operation and the laboratory results obtained with a representative configuration of the optics-free spectrometer are presented.

Judge, D. L.↗

Photonuclear cross sections for 197 Au: An update on the gold standard

Cross sections for the 197 Au(γ, n) reaction are broadly used in nuclear physics as a standard for normalizing photonuclear reaction cross-section data at photon beam energies above approximately 8 MeV. In this paper, we report cross-section measurements for the 197 Au(γ, n) 196 Au g+m1 reaction at beam energies from 13 to 31 MeV. Our measurements provide the first cross-section data for this reaction at beam energies above 20 MeV, enabling the use of this reaction as a cross-section standard up to 30 MeV. Also, this work provides first cross-section measurements for the 197 Au(γ, n) 196 Au m2 reaction. In addition, we measured cross-section data for the 197 Au(γ, 3n) 194 Au reaction, which can be used as a cross-section standard above about 25 MeV. These measurements were performed using a new target activation method that is based on the angle-energy correlation of the laser Compton- scattered photon beams at the High Intensity Gamma-ray Source (HIγS). The technique enables measuring photonuclear reaction cross-sections at several discrete beam energies concurrently via a single irradiation on a stack of different targets. Measurements were carried out by irradiating a stack of concentric-ring targets consisting of Au, TiO 2 , Zn, Os, and Au (in order of the γ-ray beam direction). Our data for the 197 Au(γ,n) 196 Au g+m1 reaction in the energy range of 13 to 20 MeV are in good agreement with existing ones measured using monoenergetic γ-ray beams, but differ from data acquired using a bremsstrahlung γ-ray beam. Also, above 18 MeV, our data for the 197 Au(γ,n) 196 Au g+m1 and 197 Au(γ,n) 196 Au m2 reactions differ significantly from the most recent TENDL and JENDL evaluations, suggesting a need to update these data libraries. Furthermore, the TENDL evaluation and existing data are consistent with our data for the 197 Au(γ,3n) reaction, but differ significantly from the JENDL evaluation above 26 MeV.

190 ≤ A ≤ 219↗

Study of the rotational-level and temperature dependence of the quenching rate of OH fluorescence due to collisions with water molecules

The importance of the OH radical as an intermediate in many combustion reactions and in atmospheric photochemistry has led many researchers to use it as a diagnostic tool in these processes. The amount of data that has been acquired over the years for this radical is quite considerable. However, the quenching rate of OH with water molecules as a function of temperature and the rotational level of the excited state is not very well understood. The motivation of the studies undertaken is to bridge the gap between the low temperature measurements and the high temperature ones reported in the literature. The technique generally employed in these diagnostics is laser-induced fluorescence (LIF), through which rotational state selective excitation of the radical is possible. Furthermore, in a combustion medium, water is produced in abundance so that knowledge of the quenching rate of OH due to water molecules plays a crucial role in interpreting the data. In general, the precursor to an understanding of the collisional quenching rates of OH involves a characterization of the mode in which the radical is produced; the resulting rotational and translational distribution, followed by a measurement of the OH temperature; and ultimately obtaining the rate constants from the pressure dependence of the fluorescence signal. The experimental implementation of these measurements therefore involved, as a first step, the production of the OH radicals in a microwave discharge cell using water vapor as the source, wherein a hydrogen atom is abstracted from H2O. The second step involved the absorption of photons from the frequency-doubled output of a pulsed amplified, single-frequency cw ring dye laser. By tuning the laser to the peak of the transition and observing the fluorescence decay after the laser pulse, the lifetime of the OH in a particular rotational electronic state was determined (tau = 1.4 microseconds for Q(sub 1)(3)). Knowledge of this parameter led to a determination of the quenching rate. By varying the water vapor pressure in the cell and measuring the lifetime as a function of pressure a linear plot of the quenching rate as a function of pressure was obtained. Using this plot, the quenching cross section was deduced. It has therefore been possible to measure the local translational temperature and the quenching cross section with one laser system.

Koker, Edmond B.↗

High angular resolution infrared mapping of the compact H II regions W51 and DR 21/W75

Far-infrared maps of W51/G49.5-0.4, W51/G49.4-0.3, and the DR 21 W75 S regions are presented. The simultaneous 50 and 100 micron maps enable a determination of the dust temperature and density structure in these areas. In G49.5-0.4 a luminosity and dust column-density peak at the position of the W51-Main maser is found, suggesting that this is the dominant luminosity source in W51. In G49.4-0.3 three components associated with the three known 2.7 GHz sources are resolved. A comparison of the total far-infrared luminosity with the radio continuum brightness in both G49.5-0.4 and G49.4-0.3 shows that the ratio of Lyman continuum to total luminosity of the exciting stars in not consistent with excitation by a single ZAMS star if most of the Lyman continuum photons are being absorbed bay gas rather than dust. In DR 21 micron far-infrared data and some new 2-20 micron results reveal a region of hot dust associated with the 2 micron H2 emission to the east and west of DR 21. Finally, a new 1.5-100 micron 'protostellar' source 2 deg north of W75 S at the position of a 1 mm continuum peak is reported.

Harvey, P. M.↗

Photofield electron emission from an optical fiber nanotip

In this work, we demonstrate a nanotip electron source based on a graded index multimode silica optical fiber, tapered at one end to a radius of curvature r ~50 nm and coated with a thin film of gold. We report observation of laser-induced electron photoemission at tip bias potentials below the onset of dark field emission. Single-photon photofield emission is identified as the emission mechanism that exhibits fast switching times with an upper limit on the order of 1 μ s. The explored fiber optic nanotips are flexible back-illuminated emitters, which can be operated in continuous wave and pulsed modes using lasers with photon energies in the visible range or higher. The mechanical flexibility of the source can facilitate externally controlled positioning. Multiple, individually addressable, nanotips may be assembled into a bundle for applications such as computational electron ghost imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly efficient visible and near-IR photon pair generation with thin-film lithium niobate

Efficient on-chip entangled photon pair generation at telecom wavelengths is an integral aspect of emerging quantum optical technologies, particularly for quantum communication and computing. However, moving to shorter wavelengths enables the use of more accessible silicon detector technology, and opens up applications in imaging and spectroscopy. Here, we present high brightness ((1.6 ± 0.3) × 10 9 pairs/s/mW/nm) visible–near-IR photon pair generation in a periodically poled lithium niobate nanophotonic waveguide. The degenerate spectrum of the photon pairs is centered at 811 nm with a bandwidth of 117 nm when pumped with a spectrally multimode laser diode. The measured on-chip source efficiency of (2.3 ± 0.5) × 10 11 pairs/s/mW is on par with source efficiencies at telecom wavelengths and is also orders of magnitude higher than the efficiencies of other visible sources implemented in bulk crystal or diffused waveguide-based technologies. Further improvements in the brightness and efficiencies are possible by pumping the device with a single-frequency laser, which would also shrink the pair bandwidth. These results represent the shortest wavelength of photon pairs generated in a nanophotonic waveguide reported to date by nearly an octave.

42 ENGINEERING↗

Investigation of pyruvic acid photolysis at the air-liquid interface as a source of aqueous secondary organic aerosols

Pyruvic acid (PA) is a ubiquitous 2-oxocarboxylic acid in the atmosphere. Its photochemical process at the air-liquid (a-l) interface has been suggested as an important source of aqueous secondary organic aerosols. Here, we investigated the photochemical reaction pathways of PA at the a-l interface using synchrotron-based vacuum ultraviolet single-photon ionization mass spectrometry (VUV SPI-MS) coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI) microreactor. Results from mass spectral analysis and the determination of appearance energies (AEs) indicate that photolysis of PA can generate radicals, then they recombine with carboxylic acids and simple molecular oligomers. Furthermore, the preliminary products could form larger oligomers via radical reaction or esterification in the presence of hydroxyl and carboxyl functional groups. Mass spectral comparison shows that most photochemical reactions would complete within 4 h. The expanded photochemistry-driven reaction flowchart of PA is proposed based on the newly discovered products. Our results reveal that the interfacial PA photochemical reactions have different mechanisms from the bulk liquid due to the interfacial properties, such as molecular density, composition, and ion concentration. Our findings show that in situ mass spectral analysis with bright photon ionization is useful to elucidate the contribution of a-l interfacial reactions leading to aqSOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Simulating dust grain-radiation coupling on a moving mesh

ABSTRACT We present a model for the interaction between dust and radiation fields in the radiation hydrodynamic code arepo-rt, which solves the moment-based radiative transfer equations on an unstructured moving mesh. Dust is directly treated using live simulation particles, each of which represent a population of grains that are coupled to hydrodynamic motion through a drag force. We introduce methods to calculate radiation pressure on and photon absorption by dust grains. By including a direct treatment of dust, we are able to calculate dust opacities and update radiation fields self-consistently based on the local dust distribution. This hybrid scheme coupling dust particles to an unstructured mesh for radiation is validated using several test problems with known analytic solutions, including dust driven via spherically symmetric flux from a constant luminosity source and photon absorption from radiation incident on a thin layer of dust. Our methods are compatible with the multifrequency scheme in arepo-rt, which treats UV, optical photons as single scattered and IR photons as multi scattered. At IR wavelengths, we model heating of and thermal emission from dust. Dust and gas are not assumed to be in local thermodynamic equilibrium but transfer energy through collisional exchange. We estimate dust temperatures by balancing these dust-radiation and dust-gas energy exchange rates. This framework for coupling dust and radiation can be applied in future radiation hydrodynamic simulations of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Scalable multiphoton quantum metrology with neither pre- nor post-selected measurements

The quantum statistical fluctuations of electromagnetic fields establish a limit, known as the shot-noise limit, on the sensitivity of optical measurements performed with classical technologies. However, quantum technologies are not constrained by this shot-noise limit. In this regard, the possibility of using every photon produced by quantum sources of light to estimate small physical parameters, beyond the shot-noise limit, constitutes one of the main goals of quantum optics. Here, we experimentally demonstrate a scalable protocol for quantum-enhanced optical phase estimation across a broad range of phases, with neither pre- nor post-selected measurements. This is achieved through the efficient design of a source of spontaneous parametric downconversion in combination with photon-number-resolving detection. The robustness of two-mode squeezed vacuum states against loss allows us to outperform schemes based on N00N states, in which the loss of a single photon is enough to remove all phase information from a quantum state. In contrast to other schemes that rely on N00N states or conditional measurements, the sensitivity of our technique could be improved through the generation and detection of high-order photon pairs. This unique feature of our protocol makes it scalable. Furthermore, our work is important for quantum technologies that rely on multiphoton interference such as quantum imaging, boson sampling, and quantum networks.

36 MATERIALS SCIENCE↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗