Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software estimation,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Evaluation of the geometric accuracy of surrogate-based gated VMAT using intrafraction kilovoltage x-ray images

Purpose: To evaluate the geometric accuracy of beam targeting in external surrogate-based gated volumetric modulated arc therapy (VMAT) using kilovoltage (kV) x-ray images acquired during dose delivery. Methods: Gated VMAT treatments were delivered using a Varian TrueBeam STx Linac for both physical phantoms and patients. Multiple gold fiducial markers were implanted near the target. The reference position was created for each implanted marker, representing its correct position at the gating threshold. The gating signal was generated from the RPM system. During the treatment, kV images were acquired immediately before MV beam-on at every breathing cycle, using the on-board imaging system. All implanted markers were detected and their 3D positions were estimated using in-house developed software. The positioning error of a marker is defined as the distance of the marker from its reference position for each frame of the images. The overall error of the system is defined as the average over all markers. For the phantom study, both sinusoidal motion (1D and 3D) and real human respiratory motion was simulated for the target and surrogate. In the baseline case, the two motions were synchronized for the first treatment fraction. To assess the effects of surrogate-target correlation on the geometric accuracy, a phase shift of 5% and 10% between the two motions was introduced. For the patient study, intrafraction kV images of five stereotactic body radiotherapy (SBRT) patients were acquired for one or two fractions. Results: For the phantom study, a high geometric accuracy was achieved in the baseline case (average error: 0.8 mm in the superior-inferior or SI direction). However, the treatment delivery is prone to geometric errors if changes in the target-surrogate relation occur during the treatment: the average error was increased to 2.3 and 4.7 mm for the phase shift of 5% and 10%, respectively. Results obtained with real human respiratory curves show a similar trend. For a target with 3D motion, the technique is able to detect geometric errors in the left-right (LR) and anterior-posterior (AP) directions. For the patient study, the average intrafraction positioning errors are 0.8, 0.9, and 1.4 mm and 95th percentile errors are 1.7, 2.1, and 2.7 mm in the LR, AP, and SI directions, respectively. Conclusions: The correlation between external surrogate and internal target motion is crucial to ensure the geometric accuracy of surrogate-based gating. Real-time guidance based on kV x-ray images overcomes the potential issues in surrogate-based gating and can achieve accurate beam targeting in gated VMAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TestSNAP

TestSNAP is a stand-alone prototype of the SNAP force kernel used in the LAMMPS molecular dynamics code. It contains synthetic input data (neighbor atom positions) and reference output data (forces on atoms) for several different SNAP models. The prototype performs the force calculation repeatedly, checking the results against the reference data. At the end it reports the grind time [msec/atomstep] and RMS force error [eV/A]. This allows performance experts to quickly test new hardware and software strategies, obtain a realistic performance estimate and verify that the computation was performed correctly. SAND2019-12243 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Thompson, Aidan↗

Autonomous Intelligent Assembly Systems LDRD 105746 (Final Report)

This report documents a three-year to develop technology that enables mobile robots to perform autonomous assembly tasks in unstructured outdoor environments. This is a multi-tier problem that requires an integration of a large number of different software technologies including: command and control, estimation and localization, distributed communications, object recognition, pose estimation, real-time scanning, and scene interpretation. Although ultimately unsuccessful in achieving a target brick stacking task autonomously, numerous important component technologies were nevertheless developed. Such technologies include: a patent-pending polygon snake algorithm for robust feature tracking, a color grid algorithm for uniquely identification and calibration, a command and control framework for abstracting robot commands, a scanning capability that utilizes a compact robot portable scanner, and more. This report describes this project and these developed technologies.

Anderson, Robert J.↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Gamma Assay System for Characterizing Excavated Soil with High {sup 137}Cs and {sup 90}Sr Contamination - 19460

We report on the recent development of a remote gamma-assay system for the measurement and characterization of high-activity soil excavated as part of an ongoing remediation project. The soil below a hot cell in our customer's facility has been contaminated with high concentrations of radionuclides {sup 137}Cs and {sup 90}Sr over the past several decades. The contaminated soil is to be remotely excavated from beneath the hot cell floor, to a depth of several feet, and placed in steel-walled waste bins for assay and disposition. The project requires measuring the {sup 137}Cs activity to a minimum detectable concentration (MDC) of 1 micro curie per gram. The high dose-rate of the material and the expectation of high Bremsstrahlung background, due to an unknown ratio of {sup 90}Sr admixture with the {sup 137}Cs, present unique measurement challenges. A novel assay system was designed to make measurements through a small access port in a 4-foot thick concrete wall isolating operators from the high-dose excavation area. Waste bins filled with soil are placed by a remotely operated crane onto an automated turntable, and initial dose measurements are taken for all bins. When excavation has proceeded to the point that dose rates below 20 Rad/hr on contact are reached, gamma spectroscopy will be used to characterize the {sup 137}Cs content. Gamma assay is performed with a 1 cm{sup 3} CZT detector in a collimated tungsten shield, which is extended through the access port toward the side of the bin by means of a seven foot long aluminum pipe. Each of the four sides of the bin is assayed in a discrete measurement, and the individual segments and summed result are reported. Canberra's NDA2000 software is used to collect and analyze the spectroscopic data and to control the turntable movement during the assay. The system is expected to meet the required MDC limits within a forty minute assay time under the most adverse conditions anticipated, with total measurement uncertainty of less than 25%. We describe in this paper the design and construction of the assay system, its calibration using the ISOCS software, and the evaluation of performance estimates. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phylogenetic trees in bioinformatics

Genetic data is often used to infer evolutionary relationships among a collection of viruses, bacteria, animal or plant species, or other operational taxonomic units (OTU). A phylogenetic tree depicts such relationships and provides a visual representation of the estimated branching order of the OTUs. Tree estimation is unique for several reasons, including: the types of data used to represent each OTU; the use ofprobabilistic nucleotide substitution models; the inference goals involving both tree topology and branch length, and the huge number of possible trees for a given sample of a very modest number of OTUs, which implies that fmding the best tree(s) to describe the genetic data for each OTU is computationally demanding. Bioinformatics is too large a field to review here. We focus on that aspect of bioinformatics that includes study of similarities in genetic data from multiple OTUs. Although research questions are diverse, a common underlying challenge is to estimate the evolutionary history of the OTUs. Therefore, this paper reviews the role of phylogenetic tree estimation in bioinformatics, available methods and software, and identifies areas for additional research and development.

97 MATHEMATICS AND COMPUTING↗

Analyzing Hardware and Software Common Cause Failures in Digital Instrumentation and Control Systems using Dual Error Propagation Method

This paper develops a methodology for quantifying software common cause failures (CCFs) in digital instrumentation and control (I&C) systems of nuclear power plants. To support the transition of analog I&C systems to digital in nuclear power plants, probabilistic risk assessment (PRA) techniques are used. The hardware components of the I&C systems have reliability databases that can be used in the PRA studies. However, the failure data for redundant software components of the systems is sparse. Failure of components constitutes a CCF, wherein two or more components or systems fail due to a single shared cause and coupling mechanism. This paper proposes a quantification approach that can simultaneously model hardware and software components, incorporate the CCFs of software systems in the models, and bridge the gap between the failure quantification of models and the development of CCF parametric databases. We demonstrate the dual error propagation method (DEPM) by developing I&C systems failure models for a representative digital reactor trip system. The DEPM models are built to simulate the control and data flows within the systems and can accommodate failure states. By expanding DEPM to software CCFs, we generated alpha factor parameter estimates for each of the modeled error propagation mechanisms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On a stochastic approach to a code performance estimation

The main goal of an efficient profiling of software is to minimize the runtime overhead under certain constraints and requirements. The traces built by a profiler during the work, affect the performance of the system itself. One of important aspect of an overhead arises from the randomness of variability in the context in which the application is embedded, e.g., due to possible cache misses, etc. Such uncertainty needs to be taken into account in the design phase. In order to overcome these difficulties we propose to investigate this issue through the analysis of the probability distribution of the difference between profiler’s times for the same code. The approximating model is based on the finite normal mixtures within the framework of the method of moving separation of mixtures. We demonstrate some results for the MATLAB profiler using plotting of 3D surfaces by the function surf. The idea can be used for an estimating of a program efficiency.

97 MATHEMATICS AND COMPUTING↗

Deformation analysis of Aceh April 11{sup th} 2012 earthquake using GPS observation data

This research tries to estimate the co-seismic deformation of intraplate earthquake occurred off northern Sumatra coast which is about 100-200 km southwest of Sumatrasubduction zone. The earthquake mechanism was strike-slip with magnitude 8.6 and triggering aftershock with magnitude 8.2 two hours later. We estimated the co-seismic deformation by using the GPS (Global Positioning System) continuous data along western Sumatra coast. The GPS observation derived from Sumatran GPS Array (SuGAr) and Geospatial Information Agency (BIG). For data processing we used GPS Analyze at Massachusetts Institute of Technology (GAMIT) software and Global Kalman Filter (GLOBK) to estimate the co-seismic deformation. From the GPS daily solution, the result shows that the earthquake caused displacement for the GPS stations in Sumatra. GPS stations in northern Sumatra showed the displacement to the northeast with the average displacement was 15 cm. The biggest displacement was found at station BSIM which is located at Simeuleu Island off north west Sumatra coast. GPS station in middle part of Sumatra, the displacement was northwest. The earthquake also caused subsidence for stations in northern Sumatra, but from the time series there was not sign of subsidence was found at middle part of Sumatra. In addition, the effect of the earthquake was worldwide and affected the other GPS Stations around Hindia oceanic.

58 GEOSCIENCES↗

Modeling of UF{sub 6} enrichment with gas centrifuges for nuclear safeguards activities

The physical modeling of uranium isotopes ({sup 235}U, {sup 238}U) separation process by centrifugation of is a key aspect for predicting the nuclear fuel enrichment plant performances under surveillance by the Nuclear Safeguards Authorities. In this paper are illustrated some aspects of the modeling of fast centrifuges for UF{sub 6} gas enrichment and of a typical cascade enrichment plant with the Theoretical Centrifuge and Cascade Simulator (TCCS). The background theory for reproducing the flow field characteristics of a centrifuge is derived from the work of Cohen where the separation parameters are calculated using the solution of a differential enrichment equation. In our case we chose to solve the hydrodynamic equations for the motion of a compressible fluid in a centrifugal field using the Berman - Olander vertical velocity radial distribution and the solution was obtained using the Matlab software tool. The importance of a correct estimation of the centrifuge separation parameters at different flow regimes, lies in the possibility to estimate in a reliable way the U enrichment plant performances, once the separation external parameters are set (feed flow rate and feed, product and tails assays). Using the separation parameters of a single centrifuge allow to determine the performances of an entire cascade and, for this purpose; the software Simulink was used. The outputs of the calculation are the concentrations (assays) and the flow rates of the enriched (product) and depleted (tails) gas mixture. These models represent a valid additional tool, in order to verify the compliance of the U enrichment plant operator declarations with the 'on site' inspectors' measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metrological characterization of X-ray diffraction methods at different acquisition geometries for determination of crystallite size in nano-scale materials

Crystallite size values were determined by X-ray diffraction methods for 183 powder samples. The tested size range was from a few to about several hundred nanometers. Crystallite size was calculated with direct use of the Scherrer equation, the Williamson–Hall method and the Rietveld procedure via the application of a series of commercial and free software. The results were statistically treated to estimate the significance of the difference in size resulting from these methods. We also estimated effect of acquisition conditions (Bragg–Brentano, parallel-beam geometry, step size, counting time) and data processing on the calculated crystallite size values. On the basis of the obtained results it is possible to conclude that direct use of the Scherrer equation, Williamson–Hall method and the Rietveld refinement employed by a series of software (EVA, PCW and TOPAS respectively) yield very close results for crystallite sizes less than 60 nm for parallel beam geometry and less than 100 nm for Bragg–Brentano geometry. However, we found that despite the fact that the differences between the crystallite sizes, which were calculated by various methods, are small by absolute values, they are statistically significant in some cases. The values of crystallite size determined from XRD were compared with those obtained by imaging in a transmission (TEM) and scanning electron microscopes (SEM). It was found that there was a good correlation in size only for crystallites smaller than 50 – 60 nm. Highlights: • The crystallite sizes for 183 nanopowders were calculated using different XRD methods • Obtained results were subject to statistical treatment • Results obtained with Bragg-Brentano and parallel beam geometries were compared • Influence of conditions of XRD pattern acquisition on results was estimated • Calculated by XRD crystallite sizes were compared with same obtained by TEM and SEM.

36 MATERIALS SCIENCE↗

Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.

60 APPLIED LIFE SCIENCES↗

Machine Learning Based System for Automated Estimation of Crystal Unit Cell Parameters from X-ray Diffraction Powder Patterns (MLCell) v0.1

This software uses machine learning models to perform inference on X-ray diffraction powder patterns, output from a diffractometer, to estimate all 6 unit cell parameters of crystalline lattices. Novel aspects of this software originated from the incorporation of concepts from crystallography to an ML-based approach; The resulting method achieves new performance capabilities without significant loss of accuracy and with less computationally intensive models.

Oklejas, Vanessa↗

Markov Random Field Based Automatic Image Alignment for ElectronTomography

Cryo electron tomography (cryo-ET) is the primary method for obtaining 3D reconstructions of intact bacteria, viruses, and complex molecular machines ([7],[2]). It first flash freezes a specimen in a thin layer of ice, and then rotates the ice sheet in a transmission electron microscope (TEM) recording images of different projections through the sample. The resulting images are aligned and then back projected to form the desired 3-D model. The typical resolution of biological electron microscope is on the order of 1 nm per pixel which means that small imprecision in the microscope's stage or lenses can cause large alignment errors. To enable a high precision alignment, biologists add a small number of spherical gold beads to the sample before it is frozen. These beads generate high contrast dots in the image that can be tracked across projections. Each gold bead can be seen as a marker with a fixed location in 3D, which provides the reference points to bring all the images to a common frame as in the classical structure from motion problem. A high accuracy alignment is critical to obtain a high resolution tomogram (usually on the order of 5-15nm resolution). While some methods try to automate the task of tracking markers and aligning the images ([8],[4]), they require user intervention if the SNR of the image becomes too low. Unfortunately, cryogenic electron tomography (or cryo-ET) often has poor SNR, since the samples are relatively thick (for TEM) and the restricted electron dose usually results in projections with SNR under 0 dB. This paper shows that formulating this problem as a most-likely estimation task yields an approach that is able to automatically align with high precision cryo-ET datasets using inference in graphical models. This approach has been packaged into a publicly available software called RAPTOR-Robust Alignment and Projection estimation for Tomographic Reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

Key Attributes of the SAPHIRE Risk and Reliability Analysis Software for Risk-Informed Probabilistic Applications

The Idaho National Laboratory is a primary developer of probabilistic risk and reliability analysis (PRRA) tools, dating back over 35 years. Evolving from mainframe-based software, the current state-of-the-practice has lead to the creation of the SAPHIRE software. Currently, agencies such as the Nuclear Regulatory Commission, the National Aeronautics and Aerospace Agency, the Department of Energy, and the Department of Defense use version 7 of the SAPHIRE software for many of their risk-informed activities. In order to better understand and appreciate the power of software as part of risk-informed applications, we need to recall that our current analysis methods and solution methods have built upon pioneering work done 30 to 40 years ago. We contrast this work with the current capabilities in the SAPHIRE analysis package. As part of this discussion, we provide information for both the typical features and special analysis capabilities which are available. We also present the application and results typically found with state-of-the-practice PRRA models. By providing both a high-level and detailed look at the SAPHIRE software, we give a snapshot in time for the current use of software tools in a risk-informed decision arena.

99 GENERAL AND MISCELLANEOUS↗

Application of Orthogonal Defect Classification for Software Reliability Analysis

The modernization of existing and new nuclear power plants with digital instrumentation and control systems (DI&C) is a recent and highly trending topic. However, there lacks strong consensus on best-estimate reliability methodologies by both the United States (U.S.) Nuclear Regulatory Commission (NRC) and the industry. This has resulted in hesitation for further modernization projects until a more unified methodology is realized. In this work, we develop an approach called Orthogonal-defect Classification for Assessing Software Reliability (ORCAS) to quantify probabilities of various software failure modes in a DI&C system. The method utilizes accepted industry methodologies for software quality assurance that are also verified by experimental or mathematical formulations. In essence, the approach combines a semantic failure classification model with a reliability growth model to predict (and quantify) the potential failure modes of a DI&C software system. The semantic classification model is used to address the question: How do latent defects in software contribute to different software failure root causes? The use of reliability growth models is then used to address the question: Given the connection between latent defects and software failure root causes, how can we quantify the reliability of the software? A case study was conducted on a representative I&C platform (ChibiOS) running a smart sensor acquisition software developed by Virginia Commonwealth University (VCU). The testing and evidence collection guidance in ORCAS was applied, and defects were uncovered in the software. Qualitative evidence, such as condition coverage, was used to gauge the completeness and trustworthiness of the assessment while quantitative evidence was used to determine the software failure probabilities. The reliability of the software was then estimated and compared to existing operational data of the sensor device. It is demonstrated that by using ORCAS, a semantic reasoning framework can be developed to justify software reliability (or unreliability) while still leveraging the strength of the existing methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HPC Usage Behavior Analysis and Performance Estimation with Machine Learning Techniques

Most researchers with little high performance computing (HPC) experience have difficulties productively using the supercomputing resources. To address this issue, we investigated usage behaviors of the world s fastest academic Kraken supercomputer, and built a knowledge-based recommendation system to improve user productivity. Six clustering techniques, along with three cluster validation measures, were implemented to investigate the underlying patterns of usage behaviors. Besides manually defining a category for very large job submissions, six behavior categories were identified, which cleanly separated the data intensive jobs and computational intensive jobs. Then, job statistics of each behavior category were used to develop a knowledge-based recommendation system that can provide users with instructions about choosing appropriate software packages, setting job parameter values, and estimating job queuing time and runtime. Experiments were conducted to evaluate the performance of the proposed recommendation system, which included 127 job submissions by users from different research fields. Great feedback indicated the usefulness of the provided information. The average runtime estimation accuracy of 64.2%, with 28.9% job termination rate, was achieved in the experiments, which almost doubled the average accuracy in the Kraken dataset.

Zhang, Hao↗

Application of Orthogonal Defect Classification for Software Reliability Analysis

The modernization of existing and new nuclear power plants with digital instrumentation and control systems (DI&C) is a recent and highly trending topic. However, there lacks strong consensus on best-estimate reliability methodologies by both the United States (U.S.) Nuclear Regulatory Commission (NRC) and the industry. This has resulted in hesitation for further modernization projects until a more unified methodology is realized. In this work, we develop an approach called Orthogonal-defect Classification for Assessing Software Reliability (ORCAS) to quantify probabilities of various software failure modes in a DI&C system. The method utilizes accepted industry methodologies for software quality assurance that are also verified by experimental or mathematical formulations. In essence, the approach combines a semantic failure classification model with a reliability growth model to predict (and quantify) the potential failure modes of a DI&C software system. The semantic classification model is used to address the question: How do latent defects in software contribute to different software failure root causes? The use of reliability growth models is then used to address the question: Given the connection between latent defects and software failure root causes, how can we quantify the reliability of the software? A case study was conducted on a representative I&C platform (ChibiOS) running a smart sensor acquisition software developed by Virginia Commonwealth University (VCU). The testing and evidence collection guidance in ORCAS was applied, and defects were uncovered in the software. Qualitative evidence, such as condition coverage, was used to gauge the completeness and trustworthiness of the assessment while quantitative evidence was used to determine the software failure probabilities. The reliability of the software was then estimated and compared to existing operational data of the sensor device. It is demonstrated that by using ORCAS, a semantic reasoning framework can be developed to justify if the software is reliable (or unreliable) while still leveraging the strength of the existing methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗