Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Application of PN and avalanche silicon photodiodes to low-level optical

New approaches to the discovery of other planetary systems require very sensitive and stable detection techniques in order to succeed. Two methods in particular, the astrometric and the photometric methods, require this. To begin understanding the problems and limitations of solid state detectors regarding this application, preliminary experiments were performed at the National Bureau of Standards and a low light level detector characterization facility was built. This facility is briefly described, and the results of tests conducted in it are outlined. A breadboard photometer that was used to obtain stellar brightness ratio precision data is described. The design principles of PN and avalanche silicon photodiodes based on low light level measuring circuits are discussed.

Eppeldauer, G.↗

The abundances of elements and isotopes in the solar wind

Studies of the chemical and isotopic composition of the solar wind are reviewed. Solar wind abundance measurements are discussed and solar wind, coronal, and photospheric abundances for elements between H and Fe are presented. Also, consideration is given to the determination of the solar wind isotopic composition of the noble gases using foil collection techniques and the observation of solar wind heavy ions with the mass per charge spectrometer on ISEE-3. Other topics include solar wind observations with solid state detectors, solar wind abundances in the magnetosheath and the plasma sheet, and high-mass resolution measurements of chemical elements and isotopes in the solar wind.

Gloeckler, George↗

Wide range magnetic electron spectrograph

An electron spectrogrpah is described that covers electron energies from 400 eV to 200 keV with an energy resolution of 10 percent. This overlaps the range of electrostatic deflection devices at low energy and solid state detectors at high energy. The spectrograph uses magnetic deflection of the electrons to achieve energy separation and images the full range of energies on a single plane. The magnetic circuit uses the fringing field of two axially located magnets to attain the large energy range. Six separate electron beams can be dispersed in the field, each entering the circuit from a different angle. This is a particular advantage when measuring plasma electron three-dimensional velocity distributions. The angular response of the instrument is particularly favorable and the stray magnetic field is sufficiently low to meet spacecraft requirements.

Coplan, M. A.↗

Photon counting modules using RCA silicon avalanche photodiodes

Avalanche photodiodes (APD) are excellent small area, solid state detectors for photon counting. Performance possibilities include: photon detection efficiency in excess of 50 percent; wavelength response from 400 to 1000 nm; count rate to 10 (exp 7) counts per sec; afterpulsing at negligible levels; timing resolution better than 1 ns. Unfortunately, these performance levels are not simultaneously available in a single detector amplifier configuration. By considering theoretical performance predictions and previous and new measurements of APD performance, the anticipated performance of a range of proposed APD-based photon counting modules is derived.

Lightstone, Alexander W.↗

Hot plasma and energetic particles in Neptune's magnetosphere

Voyager 2's low energy charged particle instrument employed an array of solid-state detectors in various configurations to measure energetic electrons and ions within the Neptune magnetosphere in several energy channels. Various features of the intensity, spectral, and anisotropic data obtained suggest that the Triton satellite exerts an important controlling influence over the outer regions of the Neptunian magnetosphere. Composition measurements have indicated the presence of H, H2, and He-4 at 1300:1:0.1 relative abundances, respectively, suggesting a Neptunian ionospheric source for the trapped particle population.

Krimigis, S. M.↗

Charged particle activation studies on the surface of LDEF spacecraft

High energy proton induced nuclear reaction products are examined using seven elements, namely: Al, Si, Ni, Co, Zr, Ta, and W. Activities were detected due to Na-22 from Al, Co-56 from Ni, Co-58 from Cu, and Y-88 from Zr targets. No induced activity was observed in Si, Ta, and W, most probably due to the long cooling times. Only Zr sample contained a weak Be-7 peak, although Ta and W were also located at the leading edge of the spacecraft. Gamma rays of individual isotopes were measured using high resolution Ge(Li) solid state detector coupled to 4096 multichannel analyzer. Activities were calculated for Co-56 (846 keV) and Co-57 (122 and 136 keV's) at the time of the entry of the spacecraft and found to be 0.014 + or - c/sec g, 0.018 + or - 0.002 c/sec g, and 0.0024 + or - 0.0007 c/sec g, respectively.

Olmez, Ilhan↗

High mass resolution isochronous time-of-flight spectrograph for three-dimensional space plasma measurements

By combining a toroidal electrostatic analyzer with a novel cylindrically symmetric isochronous time-of-flight mass spectrometer, an instrument was developed that simultaneously determines the three-dimensional distribution function of ions and differentiates species. The ion mass is determined to high resolution (M/Delta-M greater than 50) from the time of flight within a harmonic field configuration defined by hyperboloid equipotential surfaces. A second conventional time-of-flight channel makes use of particles leaving the thin entrance foil as neutrals. An additional solid state detector in which the neutrals are stopped allows the total energy and thereby the ionic charge of the incident ions to be determined as well. Information from the neutral and the ion channels can be combined to determine the total mass of an incident molecular ion and the mass of one atomic fragment.

Moebius, E.↗

Charged particle activation studies on the surface of LDEF spacecraft

High energy proton induced nuclear reaction products are examined using seven elements, namely: aluminum, silicon, nickel, copper, zirconium, tantalum, and tungsten. We detected activities due to Na-22 from Al, Co-56 and Co-57 from Ni, Co-58 from Cu, and Y-88 from Zr targets. No induced activity was observed in Si, Ta, and W, most probably due to the long cooling times. Only the Zr sample contained a weak Be-7 peak, although Ta and W were also located at the leading edge of the spacecraft. Gamma-rays of individual isotopes were measured using a high-resolution Ge(Li) solid state detector coupled to a 4096-multichannel analyzer. Activities were calculated for Co-56 (846 keV) and Co-57 (122 and 136 keV's) at the time of the entry of the spacecraft and found to be 0.014 +/- 0.005 c/s-g, 0.018 +/- 0.002 c/s-g, and 0.0024 +/- 0.0007 c/s-g, respectively.

Olmez, Ilhan↗

Determination of lunar ilmenite abundance from remotely sensed data

Of fundamental importance in the utilization of indigenous resources for a future permanently manned lunar base is the identification and mapping of the abundance distribution of the mineral ilmenite, which is currently considered the most readily identifiable and most easily accessible source of oxygen needed for human consumables and spacecraft propellant. Solid state detector array technology now permits the use of ground based multispectral remote sensing techniques to produce maps with better than one kilometer spatial resolution and uncertainties of about two weight-percent TiO2 abundance. An empirical relationship between the weight-percent abundance of titanium dioxide and the 400/560 nm spectral ratio measured in returned lunar samples was used. Because this abundance correlation is valid only for mature lunar mare regolith, the distribution of immature mafic minerals which were found to be correlated primarily with steep slopes exposing bedrock was qualitatively mapped. The first mapping phase focused on the entire lunar nearside at 5.3 km per pixel, and on experiments with more sensitive spectral ratios. Relative spectrophotometry was employed to aid in identifying wavelengths that provide greater spectral contrast. It was found that the 400/730 nm ratio improved the abundance sensitivity by 37 percent, while the 950/730 nm ratio improved mafic mineral contrast about 100 percent. The second mapping phase utilized a large experimental CCD at 280 m per pixel to map the high titanium regions identified in the phase one mapping. The high resolution maps provide data on the small scale (500 m) variations in abundance and their relationship to morphological units.

Larson, S. M.↗

The APX Spectrometer for Martian Missions

Obtaining the chemical composition of any planetary body should be a prime science objective of each planetary mission. The APX spectrometer has been designed to provide a detailed and complete chemical composition of all major (except H) and minor elements with high accuracy, in situ and remotely. From such complete analyses a first-order mineralogy of analyzed samples can be deduced. Laboratory studies in the past have shown that rock types (e.g., dunites, basalts, Philippinate 300 sample) were a uniquely in blind test analyses. Such identification is more accurate than can be obtained from any other remote spectroscopic technique. The APX technique is based on three modes of nuclear and atomic interactions of alpha particles with matter resulting in three different energy spectra containing the compositional information. The instrument uses 50 to 100 mCi of Cm-242 or Cm-244 transuranium radioisotopes to provide a monoenergetic beam of alpha particles (6.01 MeV and 5.80 MeV respectively) and solid-state detectors for acquiring the energy spectra.

Economou, T.↗

Charged particle activation studies on the surface of LDEF spacecraft

High energy proton induced nuclear reaction products are examined using seven elements, namely, Aluminum, Silicon, Nickel, Copper, Zirconium, Tantalum, and Tungsten. The samples were in the form of plates, 2 x 2 x 1/8 inches. Activities due to Na-22 from Al, Co-56 and Co-57 from Ni, Co-58 from Cu, and Y-88 from Zr targets were detected. No induced activity was observed in Si, Ta, and W, most probably due to the long cooling times. Only the Zr sample contained a weak Be-7 peak, although Ta and W were also located at the leading edge of the spacecraft. Gamma-rays of individual isotopes were measured using high-resolution Ge(Li) solid state detector coupled to 4096-multichannel analyzer. Activities were calculated for Co-56 (846 keV) and Co-57 (122 and 136 keV's) at the time of the entry of the spacecraft and found to be 0.014 plus or minus 0.005 c/sec. g, 0.018 plus or minus 0.002 c/sec. g, and 0.0024 plus or minus 0.0007 c/sec. g, respectively.

Olmez, Ilhan↗

HILT - A heavy ion large area proportional counter telescope for solar and anomalous cosmic rays

The HILT sensor has been designed to measure heavy ion elemental abundances, energy spectra, and direction of incidence in the mass range from He to Fe and in the energy range 4 to 250 MeV/nucleon. With its large geometric factor of 60 sq cm sr the sensor is optimized to provide compositional and spectral measurements for low intensity cosmic rays (i.e. for small solar energetic particle events and for the anomalous component of cosmic rays). The instrument combines a large area ion drift chamber-proportional counter system with two arrays of 16 Li-drift solid state detectors and 16 CsI crystals. The multi dE/dx-E technique provides a low background mass and energy determination. The sensor also measures particle direction. Combining these measurements with the information on the spacecraft position and attitude in the low-altitude polar orbit, it will be possible to infer the ionic charge of the ions from the local cutoff of the Earth's magnetic field. The ionic charge in this energy range is of particular interest because it provides unique clues to the origin of these particles and has not been investigated systematically so far. Together with the other instruments on board SAMPEX (LEICA, MAST, and PET), a comprehensive measurement of the entire solar and anomalous particle population will be achieved.

Klecker, Berndt↗

LEICA - A low energy ion composition analyzer for the study of solar and magnetospheric heavy ions

The SAMPEX LEICA instrument is designed to measure about 0.5-5 MeV/nucleon solar and magnetospheric ions over the range from He to Ni. The instrument is a time-of-flight mass spectrometer which measures particle time-of-flight over an about 0.5 m path, and the residual energy deposited in an array of Si solid state detectors. Large area microchannel plates are used, resulting in a large geometrical factor for the instrument (0.6 sq cm sr) which is essential for accurate compositional measurements in small solar flares, and in studies of precipitating magnetospheric heavy ions.

Mason, Glenn M.↗

Alternative wavelengths for laser ranging

The following are considered to be necessary to accomplish multicolor laser ranging: the nature of the atmospheric dispersion and absorption, the satellite/lunar/ground retro-array characteristics, and ground/satellite ranging machine performance. The energy balance and jitter budget have to be considered as well. It is concluded that the existing satellite/laser retroreflectors seem inadequate for future experiments. The Raman Stokes/Anti-Stokes (0.68/0.43 micron) plus solid state detector appear to be promising instrumentation that satisfy the ground/satellite and satellite/ground ranging machine requirements on the precision, compactness, and data processing.

Hamal, Karel↗

New perspectives for high accuracy SLR with second generation geodesic satellites

This paper reports on the accuracy limitations imposed by geodesic satellite signatures, and on the potential for achieving millimetric performances by means of alternative satellite concepts and an optimized 2-color system tradeoff. Long distance laser ranging, when performed between a ground (emitter/receiver) station and a distant geodesic satellite, is now reputed to enable short arc trajectory determinations to be achieved with an accuracy of 1 to 2 centimeters. This state-of-the-art accuracy is limited principally by the uncertainties inherent to single-color atmospheric path length correction. Motivated by the study of phenomena such as postglacial rebound, and the detailed analysis of small-scale volcanic and strain deformations, the drive towards millimetric accuracies will inevitably be felt. With the advent of short pulse (less than 50 ps) dual wavelength ranging, combined with adequate detection equipment (such as a fast-scanning streak camera or ultra-fast solid-state detectors) the atmospheric uncertainty could potentially be reduced to the level of a few millimeters, thus, exposing other less significant error contributions, of which by far the most significant will then be the morphology of the retroreflector satellites themselves. Existing geodesic satellites are simply dense spheres, several 10's of cm in diameter, encrusted with a large number (426 in the case of LAGEOS) of small cube-corner reflectors. A single incident pulse, thus, results in a significant number of randomly phased, quasi-simultaneous return pulses. These combine coherently at the receiver to produce a convolved interference waveform which cannot, on a shot to shot basis, be accurately and unambiguously correlated to the satellite center of mass. This paper proposes alternative geodesic satellite concepts, based on the use of a very small number of cube-corner retroreflectors, in which the above difficulties are eliminated while ensuring, for a given emitted pulse, the return of a single clean pulse with an adequate cross-section.

Lund, Glenn↗

Laser light scattering instrument advanced technology development

The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.

Wallace, J. F.↗

Energy deposition and middle atmosphere electrodynamic response to a highly relativistic electron precipitation event

Rocket data have been used to evaluate the characteristics of precipitating relativistic electrons and their effects on the electrodynamic structure of the middle atmosphere. These data were obtained at Poker Flat, Alaska, on May 13 and 14, 1990, during a midday, highly relativistic electron (HRE) precipitation event. Solid state detectors were used to measure the electron fluxes and their energy spectra. An X ray scintillator was included on each flight to measure bremsstrahlung X rays produced by energetic electrons impacting on the upper atmosphere. However, these were found the be of negligible importance for this particular event. The energy deposition by the electrons has been determined from the flux measurements and compared with in situ measurements of the atmospheric electrical response. The electrodynamic measurements were obtained by the same rockets and additionally on May 13, with an accompanying rocket. The impact flux was highly irregular, containing short-lived bursts of relativistic electrons, mainly with energies below 0.5 MeV and with fluxes most enhanced between pitch angles of 0 deg - 20 deg. Although the geostationary counterpart of this measured event was considered to be of relatively low intensity and hardness, energy deposition peaked near 75 km with fluxes approaching an ion pair production rate in excess of 100/cu cm s. This exceeds peak fluxes in relativistic electron precipitation (REP) events as observed by us in numerous rocket soundings since 1976. Conductivity measurements from a blunt probe showed that negative electrical conductivities exceeded positive conductivities down to 50 km or lower, consistent with steady ionization by precipitating electrons above 1 MeV. These findings imply that the electrons from the outer radiation zone can modulate the electrical properties of the middle atmosphere to altitudes below 50 km. During the decline and activity minimum of the current solar cycle, we anticipate the occurence of similar events but with fluxes 1-2 orders of magnitude above that reported here, based on studies of earlier solar cycles (e.g., Baker et al., 1993).