Variable positron annihilation radiation from the galactic center region

HEAO 3 Cosmic Gamma-Ray Spectrometer evidence is presented for the existence of a time-varying, unshifted, narrow 511 keV line emission from the vicinity of the galactic center. Although uncertainties exist regarding the spatial extent of the features as well as its centroid, all data are consistent with emission from a single point source located at the galactic center. This interpretation would require a source luminosity of 2 x 10 to the 37th ergs/sec, and a positron annihilation rate of about 10 to the 43rd/sec. It is concluded that a variable source of positrons which could generate such an annihilation figure might be a massive black hole at the galactic center, as has been suggested by IR observations.

Riegler, G. R.↗

Lightning Studies Using VHF Waveform Data

Several atmospheric electricity studies were begun utilizing VHF lightning data obtained with the lightning detection and ranging system (LDAR) at the Kennedy Space Center (KSC). The LDAR system uses differences in the time of arrival of electromagnetic noise generated by the lightning process to seven antennas to calculate very accurate three dimensional locations of lightning. New software was developed to obtain the source location of multiple, simultaneous, and spatially separate lightning signatures. Three studies utilizing these data were begun this summer: (1) VHF observations of simultaneous lightning, (2) ground based VHF observations of transionospheric pulse pairs (TIPPs), and (3) properties of intra-cloud recoil streamers. The principal result of each of these studies are: (1) lightning commonly occurs in well separated (2-50 km) regions simultaneously, (2) large amplitude pairs of VHF pulses are commonly observed on the ground but had not been previously identified due to the large number of signals usually observed in the VHF noise of close lightning, and (3) the VHF Q-noise and pulse signatures associated with K-changes within intra-cloud lightning propagate at velocities of more than 10(exp 8) m/s. The interim results of these three studies are reviewed in this brief report.

Moldwin, Mark↗

The EUVE satellite survey database

The EUVE survey database contains fundamental science data for 9000 potential source locations (pigeonholes) in the sky. The first release of the Bright Source List is now available to the public through an interface with the NASA Astrophysical Data System. We describe the database schema design and the EUVE source categorization algorithm that compares sources to the ROSAT Wide Field Camera source list.

Craig, N.↗

Acquisition of and Access to Research Omics Data

Omics data are essential for understanding the myriad and complex effects of space environments on humans. To assure maximum benefit from these kinds of data, the NASA Human Research Program Data Management Plan stipulates that human omics data should be archived within and accessed through the NASA Life Sciences Portal (NLSP). The NLSP has the capability to acquire and provision access to omics (and other kinds of) research results for individual and ad-hoc groups of subjects at the direction of institutional review boards, or other authorizing bodies or individuals, per institutional, program and investigation-specific policies and procedures. However, because some single-subject omics data, like CT scans and other kinds of large, complex biomedical data, could be used to identify heretofore unknown risks to the subject’s health, or, in certain cases, be used to identify a subject, NASA Policy Directive 7170.1 describes various policies regarding the management of and access to “research genetic testing” data, which includes many kinds of omics data. For example, NPD 7170.1 prohibits access to human research genetic data by NASA personnel who make employment decisions for the subjects from whom the data were obtained. To meet the objective of acquiring research omics data for NLSP in compliance with the policies in NPD 7170.1 and other applicable NASA policies, we designed NOMADS (the NLSP Omics Multimodal Acquisition of Data System), a new component that supports the transfer of large research data files, including research genetic testing data, using one of several different transfer mechanisms. The choice of mechanism is made by the submitter of the data, with guiding information from the system, and is likely to often be determined in large part by the nature and source location of the data. For example, for small files where the source data files are not already stored in a cloud storage system, users are likely to prefer to transfer their data to the NLSP via a web browser. Conversely, for large sets of files already organized and stored in a cloud storage system, users may opt for NOMAD’s cloud-to-cloud transfer method. All omics datasets targeted for the NASA Life Sciences Data Archive must pass a variety of quality checks to ensure data integrity and adherence to the standards defined by the LSDA Data Submission Guidelines (DSG) (see https://nlsp.nasa.gov/explore/lsdahome/datasubmit). These include requirements that data are consistent with open standards established by the omics community. Non-compliant data will not be accepted however archivists are available to advise submitters on how to revise data submissions and re-submit until compliance is achieved. Following compliance with the LSDA DSG, omics data next undergo a variety of additional quality checks to ensure the data meet omics community standards. Domain specific Omics data quality control tools and techniques are continually evolving and linked to the advancements in omics assays utilized and thus, the tools and techniques utilized by the LSDA for data quality control and validation will need to be sustained accordingly. All human omics data will be access controlled according to the policies described above, and requiring IRB approval for any additional access grants once the data are acquired (including access for analysis using the NLSP workspace tools).

Omics↗

Acquisition of and Access to Research Omics Data

Omics data are essential for understanding the myriad and complex effects of space environments on humans. To assure maximum benefit from these kinds of data, the NASA Human Research Program Data Management Plan stipulates that human omics data should be archived within and accessed through the NASA Life Sciences Portal (NLSP). The NLSP has the capability to acquire and provision access to omics (and other kinds of) research results for individual and ad-hoc groups of subjects at the direction of institutional review boards, or other authorizing bodies or individuals, per institutional, program and investigation-specific policies and procedures. However, because some single-subject omics data, like CT scans and other kinds of large, complex biomedical data, could be used to identify heretofore unknown risks to the subject’s health, or, in certain cases, be used to identify a subject, NASA Policy Directive 7170.1 describes various policies regarding the management of and access to “research genetic testing” data, which includes many kinds of omics data. For example, NPD 7170.1 prohibits access to human research genetic data by NASA personnel who make employment decisions for the subjects from whom the data were obtained. To meet the objective of acquiring research omics data for NLSP in compliance with the policies in NPD 7170.1 and other applicable NASA policies, we designed NOMADS (the NLSP Omics Multimodal Acquisition of Data System), a new component that supports the transfer of large research data files, including research genetic testing data, using one of several different transfer mechanisms. The choice of mechanism is made by the submitter of the data, with guiding information from the system, and is likely to often be determined in large part by the nature and source location of the data. For example, for small files where the source data files are not already stored in a cloud storage system, users are likely to prefer to transfer their data to the NLSP via a web browser. Conversely, for large sets of files already organized and stored in a cloud storage system, users may opt for NOMAD’s cloud-to-cloud transfer method. All omics datasets targeted for the NASA Life Sciences Data Archive must pass a variety of quality checks to ensure data integrity and adherence to the standards defined by the LSDA Data Submission Guidelines (DSG) (see https://nlsp.nasa.gov/explore/lsdahome/datasubmit). These include requirements that data are consistent with open standards established by the omics community. Non-compliant data will not be accepted however archivists are available to advise submitters on how to revise data submissions and re-submit until compliance is achieved. Following compliance with the LSDA DSG, omics data next undergo a variety of additional quality checks to ensure the data meet omics community standards. Domain specific Omics data quality control tools and techniques are continually evolving and linked to the advancements in omics assays utilized and thus, the tools and techniques utilized by the LSDA for data quality control and validation will need to be sustained accordingly. All human omics data will be access controlled according to the policies described above, and requiring IRB approval for any additional access grants once the data are acquired (including access for analysis using the NLSP workspace tools).

Omics↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

On a Method For Reconstructing Computed Tomography Datasets from an Unstable Source

As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.

47 OTHER INSTRUMENTATION↗

HEAO-A nominal scanning observation schedule

The HEAO-A observatory, scheduled for launch in late June 1977, will spend most of its orbital lifetime in a scanning mode, spining from 0.03 to 0.1 rpm about an axis aligned with the sun. The dates of availability in the scan band are given for a list of 248 X-ray sources. Celestial maps of source locations and scan planes, and examples of the nighttime elevation of available sources are presented. This document is intended to aid ground-based observers in planning coordinated observations with HEAO-A.

Fishman, G. J.↗

Source polarization effects in an optical fiber fluorosensor

The exact field solution of a step-index profile fiber was used to determine the injection efficiency of a thin-film distribution of polarized sources located in the cladding of an optical fiber. Previous results for random source orientation were confirmed. The behavior of the power efficiency, P(eff), of a polarized distribution of sources was found to be similar to the behavior of a fiber with sources with random orientation. However, for sources polarized in either the x or y direction, P(eff) was found to be more efficient.

Egalon, Claudio O.↗

Moment tensor reconstruction

A seismic monitoring system includes a plurality of seismic monitors and a processing device operatively coupled to the plurality of seismic monitors. The processing device receives recordings of waveforms of motion detected at the plurality of seismic detectors in a geographic area. The processing device applies the respective recordings to corresponding positions of the seismic detectors in a three-dimensional geological model that describes its elastic attributes and tests a plurality of moment tensors at a plurality of locations. Based on the testing, the processing device determines a globally convergent source location and moment tensor in the three-dimensional model based on the testing.

Petrov, Petr↗

Radiation asymmetry during shattered pellet and massive gas injection in DIII-D

Infrared thermography of the first wall in DIII-D is used to show the toroidal peaking of plasma radiation during mitigated disruptions with shattered pellet injection (SPI) and with massive gas injection (MGI). During MGI, the radiation peak location is shown to be due to the n = 1 magnetohydrodynamic (MHD) activity and continuously variable in toroidal phase based on externally applied error fields, consistent with previous experimental results. Furthermore, the measured toroidal peaking factor (TPF) is in agreement with the previous estimates based on radiometry, with a total TPF of 1.07 ± 0.05 when integrated over the entire duration of the disruption, and a value of 1.3 ± 0.1 during the thermal quench (TQ). For SPI, the location of the radiation peak is found to be determined predominantly by the particle source location, and thus can be varied on DIII-D by injecting from either of two toroidally separated injectors. 3D non-linear MHD simulations with the NIMROD code support this picture. The localized SPI particle source leads to higher peaking than for MGI, with a total TPF of 1.3 ± 0.1 over the full disruption and a TQ TPF of 1.9 +0.5/−0.3, a value also consistent with the NIMROD simulations. This TQ value is close to or potentially exceeding the allowable limit for the previously planned Be first wall in ITER, pointing to the importance of radiation asymmetries depending on the choice of first wall material.

Physics - Plasma physics↗

A Frequency-Domain-Based Algorithm for Detecting Microseismicity Using Dense Surface Seismic Arrays

We propose a new frequency-domain-based algorithm for detecting small-magnitude seismic events using dense surface seismic arrays. Our proposed method takes advantage of the high energy carried by S waves, and approximate known source locations, which are used to rotate the horizontal components to obtain the maximum amplitude. By surrounding the known source area with surface geophones, we achieve a favorable geometry for locating the detected seismic events with the backprojection method. To test our new detection method, we used a dense circular array, consisting of 151 5 Hz three-component geophones, over a 5 km aperture that was in operation at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) in southcentral Utah. We apply the new detection method during a small-scale test injection phase at FORGE, and during an aftershock sequence of an Mw 4.1 earthquake located ~30 km north of the geophone array, within the Black Rock volcanic field. We are able to detect and locate microseismic events (Mw<0) during injections, despite the high level of anthropogenic activity, and several aftershocks that are missing from the regional catalog. By comparing our method with known algorithms that operate both in the time and frequency domain, we show that our proposed method performs better in the case of the FORGE injection monitoring, and equally well for the off-array aftershock sequence. Our new method has the potential to improve microseismic event detections even in extremely noisy environments, and the proposed location scheme serves as a direct discriminant between true and false detections.

Geochemistry & Geophysics↗

Gamma Ray Bursts-Afterglows and Counterparts

Several breakthrough discoveries were made last year of x-ray, optical and radio afterglows and counterparts to gamma-ray bursts, and a redshift has been associated with at least one of these. These discoveries were made possible by the fast, accurate gamma-ray burst locations of the BeppoSAX satellite. It is now generally believed that the burst sources are at cosmological distances and that they represent the most powerful explosions in the Universe. These observations also open new possibilities for the study of early star formation, the physics of extreme conditions and perhaps even cosmology. This session will concentrate on recent x-ray, optical and radio afterglow observations of gamma-ray bursts, associated redshift measurements, and counterpart observations. Several review and theory talks will also be presented, along with a summary of the astrophysical implications of the observations. There will be additional poster contributions on observations of gamma-ray burst source locations at wavelengths other than gamma rays. Posters are also solicited that describe new observational capabilities for rapid follow-up observations of gamma-ray bursts.

Fishman, Gerald J↗

A search for embedded young stellar objects in and near the IC 1396 complex

The IRAS data base is used to locate young stellar object candidates in and near the IC 1396 complex located in the Cepheus OB2 association. Co-added survey data are used to identify all sources with a flux density Snu(100) greater than 10 Jy and with Snu(100) greater than Snu(60). The 15 sources located at the positions of globules and dark clouds are further analyzed using the inscan slices to assess the source profiles.

Schwartz, Richard D.↗

Stopping criteria for ending autonomous, single detector radiological source searches

While the localization of radiological sources has traditionally been handled with statistical algorithms, such a task can be augmented with advanced machine learning methodologies. The combination of deep and reinforcement learning has provided learning-based navigation to autonomous, single-detector, mobile systems. However, these approaches lacked the capacity to terminate a surveying/search task without outside influence of an operator or perfect knowledge of source location (defeating the purpose of such a system). Two stopping criteria are investigated in this work for a machine learning navigated system: one based upon Bayesian and maximum likelihood estimation (MLE) strategies commonly used in source localization, and a second providing the navigational machine learning network with a “stop search” action. A convolutional neural network was trained via reinforcement learning in a 10 m × 10 m simulated environment to navigate a randomly placed detector-agent to a randomly placed source of varied strength (stopping with perfect knowledge during training). The network agent could move in one of four directions (up, down, left, right) after taking a 1 s count measurement at the current location. During testing, the stopping criteria for this navigational algorithm was based upon a Bayesian likelihood estimation technique of source presence, updating this likelihood after each step, and terminating once the confidence of the source being in a single location exceeded 0.9. A second network was trained and tested with similar architecture as the previous but which contained a fifth action: for self-stopping. The accuracy and speed of localization with set detector and source initializations were compared over 50 trials of MLE-Bayesian approach and 1000 trials of the CNN with self-stopping. The statistical stopping condition yielded a median localization error of ~1.41 m and median localization speed of 12 steps. The machine learning stopping condition yielded a median localization error of 0 m and median localization speed of 17 steps. This work demonstrated two stopping criteria available to a machine learning guided, source localization system.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗