Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Utah FORGE CoreFlooding Experimental Results

This submission contains associated data from 100C and 200C core-flooding experiments conducted by Lawrence Livermore National Laboratory. The samples used were sourced from 16A(78)-32 well core. The primary objectives of these tests were to determine the change in calculated hydraulic fracture and permeability over time, under constant confining pressure, in predominantly constant flowrate conditions, while monitoring effluent chemistry as a function of time.

15 GEOTHERMAL ENERGY↗

Effect of Extinction on Quasar Luminosity Distances Determined from UV and X-Ray Flux Measurements

Abstract In Khadka et al., a sample of X-ray-detected reverberation-mapped quasars was presented and applied for the comparison of cosmological constraints inferred using two well-established relations in active galactic nuclei—the X-ray/UV luminosity ( L X – L UV ) relation and the broad-line region radius–luminosity ( R – L ) relation. L X – L UV and R – L luminosity distances to the same quasars exhibit a distribution of their differences that is generally asymmetric and positively shifted for the six cosmological models we consider. We demonstrate that this behavior can be interpreted qualitatively as arising as a result of the dust extinction of UV/X-ray quasar emission. We show that the extinction always contributes to the nonzero difference between L X – L UV -based and R – L -based luminosity distances and we derive a linear relationship between the X-ray/UV color index E X −UV and the luminosity-distance difference, which also depends on the value of the L X – L UV relation slope. Taking into account the median and the peak values of the luminosity-distance difference distributions, the average X-ray/UV color index falls in the range of E ¯ X − UV = 0.03 – 0.28 mag for the current sample of 58 sources. This amount of extinction is typical for the majority of quasars and can be attributed to the circumnuclear and interstellar media of host galaxies. After applying the standard hard X-ray and far-UV extinction cuts, heavily extincted sources are removed but overall the shift toward positive values persists. The effect of extinction on luminosity distances is more pronounced for the L X – L UV relation since the extinction of UV and X-ray emissions both contribute.

Astronomy & Astrophysics↗

Flow cell sample generator

A sample generator system includes a fluid source and a flow cell. The sample generator system includes a sampling system in communication with the flow cell to eject a fluid sample through an orifice in the flow cell. The sample generator system includes a gas pressure at the orifice in the flow cell greater than or equal to a fluid pressure at the orifice in the flow cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme synthesis of crystalline aerogel materials from amorphous aerogel precursors

In one embodiment, a composition of matter includes a crystalline porous structure having a density in a range from about 30 to about 50 mg/cm 3 . In another embodiment, a kit includes an amorphous, porous material, an inert pressure medium, a heating source, and a sample chamber configured to withstand an applied pressure of at least about 20 GPa. Other aspects and embodiments of the present invention will become apparent from the following detailed description, which, when taken in conjunction with the drawings, illustrate by way of example the principles of the invention.

Pauzauskie, Peter J.↗

P- and S-Wave velocity and Indirect Tensile Measurements for Alluvium in Support of the Source Physics Experiments

Mechanical properties on alluvium blocks and core samples were determined to support the Source Physics Experiment Dry Alluvium Geology experimental series. Because material was not available directly from the experimental location, the alluvium blocks and core samples are intended to serve as surrogate material . P - and S - wave velocity was measured on cubes cut from the alluvium blocks and core with the intention to study variation from water content and measured direction (material anisotropy). Indirect tensile tests were conducted dry and with moisture ranging from 6 to 9.1%. For the range of water content tested, increasing moisture level resulted in slower P - and S - wave velocities. P - and S - wave variability is less influenced by material heterogeneity than moisture content. P - wave velocity ranges from 629 m/s to 2599 m/s and S - wave velocity ranges from 288 m/s to 1200 m/s. Counter to the velocity measurement findings, material variability on indirect tensile strength has a greater effect than moisture content. Compared to dry strength and at moisture levels from 6 to 9% the block's tensile strength was lowered by at least a factor of 5. Indirect tensile strength for the first block averaged 0.35 MPa and 0.25 MPa for dry and 8.9% moisture respectively. For the second block indirect tensile strength averaged 0.05 MPa for both dry and 6.4% moisture.

36 MATERIALS SCIENCE↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗

A Machine Learning Method for the Forensics Attribution of Separated Plutonium

Plutonium (Pu) source attribution would be a powerful tool to support nuclear nonproliferation efforts. This capability to find the source of a Pu sample would act as a deterrent to smuggling efforts, and also help regulatory agencies verify declared nuclear activities. Work at Texas A&M University yielded a nuclear forensics methodology, which is capable of determining separated Pu’s reactor of origin, fuel burnup, and the time since irradiation (TSI)—three parameters of interest. The methodology used a set of ten intra-element isotopic ratios found in separated Pu, which was compared to a library of isotopic ratio values produced using neutronics simulations for reactors of interest. By calculating the probability that unknown Pu sample’s isotopic ratio set matched a set in the library, the methodology could predict the three parameters of interest of the sample. One shortcoming of this methodology was an inability to correctly attribute spoofed Pu, where Pu sourced from two different reactors or two different fuel burnup levels are mixed. A new methodology to rectify this vulnerability using machine learning (ML) technique is developed, instead of the maximum likelihood calculation previously used and the results are satisfactory. The ML approach leverages the existing simulated data for training the algorithm, but use them efficiently by only using intra-element isotope ratios that contribute to the attribution one of the three parameters at a time. Previously, all isotope ratios were used to attribute all three parameters together. The new methodology attributes the Pu parameters in three steps, one for each parameter, rather than resolving all of the three parameters simultaneously like the previous maximum likelihood approach. First, a support vector machine classifier with a set of seven isotopic ratios finds the reactor of origin and a set of regression models trained using gaussian process predicts the burnup with a different set of seven isotopes. Finally, TSI is calculated analytically using decay equations. Thus far, the new methodology is capable of attributing pure Pu samples and has been validated using experimental data. The next step will to be augment the classifier training data set with spoofed Pu data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Internet of Samples

Abstract Material samples are indispensable data sources in many natural science, social science, and humanity disciplines. More and more researchers recognize that samples collected in one discipline can be of great value for another. This has motivated organizations that manage a large number of samples to make their holdings accessible to the world. Currently, multiple projects are working to connect natural history and other samples managed by individual institutions or individuals into a universe of samples that follow FAIR principles. This poster reports the progress of the US NSF‐funded iSamples project, in the context of other efforts initiated by US DOE, DiSCCo, BCoN, and GBIF. By October 2021, we will also be able to present an iSamples prototype. We encourage individual organizations that hold material samples to get to know these projects and help shape these projects to realize the goal of a global linked sample cloud that connects all material samples and is accessible to all.

Richard, Stephen M.↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Summary of Analytical Services for the Hanford Site Radionuclide NESHAP Program

This document is a summary of the point source analytical requirements used to demonstrate compliance for the Department of Energy (DOE) Hanford Site operations with 40 Code of Federal Regulations (CFR) Part 61, “National Emission Standards for Hazardous Air Pollutants,” (NESHAP) Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities,” and the Washington Administrative Code (WAC) 246-247, “Radiation Protection – Air Emissions.” This reference collects information from multiple source documents and is not intended to create, supersede, replace or over-ride any existing contractual, DOE, federal or state statutes, regulations, compliance agreements, orders, permits, licenses or other requirements. The requirement source document governs where any difference may exist. The Hanford Mission Integration Solutions (HMIS) Environmental organization has been contracted by DOE to manage and report data collected from the sampling and monitoring of radioactive air emissions point sources, colloquially called stacks. The Environmental organization coordinates the analyses and reporting of samples collected at various facilities across the Hanford Site. These facilities operate approximately 52 stacks that require sampling, monitoring or estimating radioactive air emissions. The stacks are operated by Bechtel National, Inc. (BNI), Central Plateau Cleanup Company (CPCCo), Hanford Tank Waste Operations & Closure (H2C), Hanford Laboratory Management and Integration (HLMI), and Pacific Northwest National Laboratory (PNNL). Stack samples from CPCCo, HLMI and H2C facilities are collected by the operating contractor staff, delivered to HMIS, and then shipped to an offsite contracted laboratory for analyses. The field and laboratory sample data uploaded into the Sample Management and Analytical Results Tracking (SMART) database are used to calculate sample volumes and concentrations. Sample concentrations are evaluated for compliance with federal and state regulations, permits, and license requirements. The SMART database also calculates total curies released for sampled point sources and stacks. Point source effluent concentrations and releases are published annually in publicly available reports. The BNI and PNNL operate several DOE-Hanford Field Office (HFO) stacks subject to the requirements of 40 CFR 61, Subpart H and WAC 246-247. The concentrations, curies released and dose modeling evaluation for these stacks are included in the DOE-HFO annual radionuclide NESHAP report. The sample collection, analyses and emissions estimates for these stacks are outside the scope of HMIS contracted responsibilities and not addressed further in this document.

54 ENVIRONMENTAL SCIENCES↗

The rapid transition from star formation to AGN-dominated rest-frame ultraviolet light at z ≃ 4

ABSTRACT With the advent of deep optical-to-near-infrared extragalactic imaging on the degree scale, samples of high-redshift sources are being selected that contain both bright star-forming (SF) galaxies and faint active galactic nuclei (AGN). In this study, we investigate the transition between SF- and AGN-dominated systems at z ≃ 4 in the rest-frame ultraviolet (UV). We find a rapid transition to AGN-dominated sources brightward of MUV ≃ −23.2. The effect is observed in the rest-frame UV morphology and size–luminosity relation, where extended clumpy systems become point-source-dominated, and also in the available spectra for the sample. These results allow us to derive the rest-frame UV luminosity function (LF) for the SF- and AGN-dominated subsamples. We find the SF-dominated LF is best fit with a double power law, with a lensed Schechter function being unable to explain the existence of extremely luminous SF galaxies at MUV ≃ −23.5. If we identify AGN-dominated sources according to a point-source morphology criterion, we recover the relatively flat faint-end slope of the AGN LF determined in previous studies. If we instead separate the LF according to the current spectroscopic AGN fraction, we find a steeper faint-end slope of α = −1.83 ± 0.11. Using a simple model to predict the rest-frame AGN LF from the z = 4 galaxy LF, we find that the increasing impact of host galaxy light on the measured morphology of faint AGN can explain our observations.

Bowler, R. A. A.↗

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Observations of compact sources in galaxy clusters using MUSTANG2

Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev–Zel’dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary – largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper, we present 90 GHz compact source measurements from a sample of 30 clusters observed using the MUSTANG2 instrument on the Green Bank Telescope. We present simulations of how a source’s flux density, spectral index, and angular separation from the cluster’s centre affect the measured tSZE in clusters detected by the Atacama Cosmology Telescope (ACT). By comparing the MUSTANG2 measurements with these simulations we calibrate an empirical relationship between 1.4 GHz flux densities from radio surveys and source contamination in ACT tSZE measurements. We find 3 per cent of the ACT clusters have more than a 20 per cent decrease in Compton-y but another 3 per cent have a 10 per cent increase in the Compton-y due to the matched filters used to find clusters. As sources affect the measured tSZE signal and hence the likelihood that a cluster will be detected, testing the level of source contamination in the tSZE signal using a tSZE-selected catalogue is inherently biased. We confirm this by comparing the ACT tSZE catalogue with optically and X-ray-selected cluster catalogues. Furthermore, there is a strong case for a large, high-resolution survey of clusters to better characterize their source population.

79 ASTRONOMY AND ASTROPHYSICS↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deciphering the source of primary biological aerosol particles: a pollen case study

Primary biological aerosol particles (PBAPs) are microscopic solids suspended in the atmosphere emitted by biological systems and play critical roles in the atmosphere and at the atmosphere-biosphere interface, impacting human health, climate, and the ecosystem function. Understanding the sources of PBAPs is necessary to decipher the mechanistic interactions between aerosols, climate, and distinct ecosystem components. However, the detection of specific PBAPs in complex ambient aerosol samples is challenging. We performed metabolomics analyses of pollen from three pollinating tree species and ambient samples collected during the peak pollination period of each species. Random Forest and sPLS-DA machine learning methods were employed to evaluate whether metabolic signatures of ambient samples can reveal the source of the main pollen particles present in the atmosphere. Our results suggest that atmospheric eco-metabolomics techniques combined with sophisticated statistical methods can decipher the origin of abundant PBAPs from complex ambient samples. Developing complete libraries containing high-resolution metabolomic fingerprints of the major PBAPs present in the atmosphere would significantly advance future research to accurately understand the role of PBAPs in the atmosphere, ecosystems and human health.

Rivas-Ubach, Albert↗

Detecting Long-period Variability in the SDSS Stripe 82 Standards Catalog

We report the results of a search for long-period (100 < P < 600 days) periodic variability in the SDSS Stripe 82 standards catalog. The SDSS coverage of Stripe 82 enables such a search because there are on average 20 observations per band in ugriz bands for about one million sources, collected over about 6 yr, with a faint limit of r ~ 22 mag and precisely calibrated 1%–2% photometry. We calculated the periods of variable source candidates in this sample using the Lomb–Scargle periodogram and considered the three highest periodogram peaks in each of the gri filters as relevant. Only those sources with gri periods consistent within 0.1% were later studied. We use the Kuiper statistic to ensure uniform distribution of data points in phased light curves. We present five sources with the spectra consistent with quasar spectra and plausible periodic variability. This SDSS-based search bodes well for future sensitive large-area surveys, such as the Rubin Observatory Legacy Survey of Space and Time, which, due to its larger sky coverage (about a factor of 60) and improved sensitivity (~2 mag), will be more powerful for finding such sources.

79 ASTRONOMY AND ASTROPHYSICS↗