Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Advanced Characterization Techniques for Overcoming Challenges of Perovskite Solar Cell Materials

Abstract In the last 10 years, organic–inorganic hybrid perovskite solar cells have achieved unprecedented advances, to the point where they now exhibit extremely high efficiency. However, long‐term stability and areal scalability limitations impede the commercial application of perovskite materials, and appropriate diagnosistic tools have become necessary to evaluate perovskite materials. Characterization of perovskite materials is regularly misinterpretated, due to unique intrinsic and extrinsic factors: degradation from the measurement source, ion migration, phase transition, and separation. Herein, studies on perovskites are reviewed that have used advanced characterization tools to overcome characterization challenges. Cryogenic temperature assisted measurements mitigate degradation or phase transitions induced by the measurement source. In situ measurements can track the variation of perovskite materials depending on external stimuli. Spatial material properties are able to be evaluated by the use of multidimensional mapping techniques. An overview of these advanced characterization tools that can overcome the challenges associated with established tools provides the opportunity for further understanding perovskite materials and solving the remaining challenges on the road to commercialization.

Kim, Min‐cheol↗

Monitoring water quality in the lower Kansas River using remote sensing

Abstract We demonstrate how to combine remote sensing data from satellite imagery (Sentinel‐2) with in situ water quality gauging (USGS Super Gages and the Gybe hyperspectral radiometer) to create spatially dense maps of water quality parameters (chlorophyll‐a concentration, turbidity, and nitrate plus nitrite concentration) along the lower Kansas River. The water quality maps are created using locally tuned models of the target water quality parameters, and this study describes the steps used to design, calibrate, and validate the empirical correlations. Water quality parameters such as chlorophyll‐a concentration are correlated with well‐studied absorption and scattering features in the visible spectrum (roughly 400–700 nm). Nutrients (such as nitrate plus nitrite concentration) lack strong absorption features in the visible spectrum, and in those cases we describe a novel surrogate data modeling approach that identifies overlapping water parcels between the in situ gauging and the remote sensing imagery. Measurements from the overlapping water parcels yield excellent correlations () for the target water quality parameters for limited windows of time (or limited sections of river reaches). Examples are provided illustrating how the water quality maps can be used to track river inputs from ungauged sources (such as creeks), or reveal the mixing patterns at the confluences.

Tufillaro, Nicholas↗

Evolution of tensile and shear cracking in crystalline rocks under compression

Here we performed laboratory-scale unconfined compression experiments on Barre granite specimen with a single pre-existing flaw to study the evolution of tensile and shear cracking that occurs during different stress levels. Moment tensor inversion of acoustic emission (AE) events in combination with the nonelastic strain component obtained through the 2D digital image correlation (DIC) technique are used to track the changes in the source mechanisms of the stress-induced cracks. The mode of deformation computed from the image based strain profiles, enables visual comparison of the nucleation, growth and interaction of the tensile and shear cracks with the microseismic source mechanism observed by moment tensor inversion of the AE events. Comparing the results obtained from the two techniques on the same dataset demonstrates a quantitative correlation between the acoustic and visual observations in terms of the cracking mechanisms obtained at different stages of cracking from crack initiation at the flaw tips to the failure of the rock specimen.

58 GEOSCIENCES↗

Dose mapping of the rectal wall during brachytherapy with an array of scintillation dosimeters

Purpose: In pelvic brachytherapy treatments, the rectum is an organ at risk. The authors have developed an array of scintillation dosimeters suitable for in vivo use that enables quality assurance of the treatment delivery and provides an alert to potential radiation accidents. Ultimately, this will provide evidence to direct treatment planning and dose escalation and correlate dose with the rectal response. Methods: An array of 16 scintillation dosimeters in an insertable applicator has been developed. The dosimeters were calibrated simultaneously in a custom designed circular jig before use. Each dosimeter is optically interfaced to a set of pixels on a CCD camera located outside the treatment bunker. A customized software converts pixel values into dose rate and accumulates dose for presentation during treatment delivery. The performance of the array is tested by simulating brachytherapy treatments in a water phantom. The treatment plans were designed to deliver a known dose distribution on the surface of the rectal applicator, assumed to represent the dose to the rectal wall. Results: The measured doses were compared to those predicted by the treatment plan and found to be in agreement to within the uncertainty in measurement, usually within 3%. The array was also used to track the progression of the source as it moved along the catheter. The measured position was found to agree with the position reported by the afterloader to within the measurement uncertainty, usually within 2 mm. Conclusions: This array is capable of measuring the actual dose received by each region of the rectal wall during brachytherapy treatments. It will provide real time monitoring of treatment delivery and raise an alert to a potential radiation accident. Real time dose mapping in the clinical environment will give the clinician additional confidence to carry out dose escalation to the tumor volume while avoiding rectal side effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft, Inc., was characterized by Rivard et al. in 2006. Since then, the source design was modified to include a new insert at the source tip. Current study objectives were to establish an accurate source model for simulation purposes, dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and determine dose differences between the original simulation model and the current model S700 source design. Methods: Design information from measurements of dissected model S700 sources and from vendor-supplied CAD drawings was used to aid establishment of an updated Monte Carlo source model, which included the complex-shaped plastic source-centering insert intended to promote water flow for cooling the source anode. These data were used to create a model for subsequent radiation transport simulations in a water phantom. Compared to the 2006 simulation geometry, the influence of volume averaging close to the source was substantially reduced. A track-length estimator was used to evaluate collision kerma as a function of radial distance and polar angle for determination of TG-43 dosimetry parameters. Results for the 50 kV source were determined every 0.1 cm from 0.3 to 15 cm and every 1° from 0° to 180°. Photon spectra in water with 0.1 keV resolution were also obtained from 0.5 to 15 cm and polar angles from 0° to 165°. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.04% at r = 1 cm and 0.06% at r = 5 cm. Results: The dose-rate distribution ratio for the model S700 source as compared to the 2006 model exceeded unity by more than 5% for roughly one quarter of the solid angle surrounding the source, i.e., θ ≥ 120°. The radial dose function diminished in a similar manner as for an {sup 125}I seed, with values of 1.434, 0.636, 0.283, and 0.0975 at 0.5, 2, 5, and 10 cm, respectively. The radial dose function ratio between the current and the 2006 model had a minimum of 0.980 at 0.4 cm, close to the source sheath and for large distances approached 1.014. 2D anisotropy function ratios were close to unity for 50° ≤ θ ≤ 110°, but exceeded 5% for θ < 40° at close distances to the sheath and exceeded 15% for θ > 140°, even at large distances. Photon energy fluence of the updated model as compared to the 2006 model showed a decrease in output with increasing distance; this effect was pronounced at the lowest energies. A decrease in photon fluence with increase in polar angle was also observed and was attributed to the silver epoxy component. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% in several regions. This discrepancy is greater than the dose calculation acceptance criteria as recommended in the AAPM TG-56 report. The effect of the design change on the TG-43 parameters would likely not result in dose differences outside of patient applicators. Adoption of this new dataset is suggested for accurate depiction of model S700 source dose distributions.

60 APPLIED LIFE SCIENCES↗

Probabilistic Economic Valuation of Safety Margin Management

The goal of this project was to explore a new methodology for evaluation of potential safety margin upgrades to add a new instrument to the Risk Informed Safety Margin Characterization (RISMC) toolkit. To this end, the RAVEN code developed by the Idaho National Laboratory was used to perform a cost-benefit analysis of several potential power plant safety upgrades to compare the material cost of the upgrades with the probabilistic benefit of avoiding accident scenario consequences to find the most cost-effective safety upgrades. By coupling RAVEN to MELCOR to drive Monte-Carlo method stochastic parameter analysis and using data from existing nuclear codes, as well as MELCOR’s radionuclide relocation tracking capabilities, the radionuclide release source term activity in a severe accident scenario can be estimated. Severe Accident Mitigation upgrades were benchmarked against the Hardened Containment Ventilation upgrade mandated by the USNRC for Mk1 BWRs using dollars spent per Curie of release prevented as a metric by which to evaluate the economic efficacy of the upgrades. Additionally, Fault Tree/Event Tree-based analyses were performed to compare older methods of evaluation to the methodology pioneered in this work, and Monthly Operating Report (MORP) outage data was analyzed for insights into power plant outage optimization and reduction.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Drones for Decommissioning

The U.S. Nuclear Regulatory Commission has responsibility for regulating the safe decommissioning of facilities and sites to meet the License Termination Rule in 10 Code of Federal Regulations (CFR) Part 20, Standards for Protection Against Radiation, Subpart E “Radiological Criteria for License Termination.” Decommissioning is performed in accordance with 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, as part of license termination (§50.82) and release of the facility or site for unrestricted use (§50.83). The guidance currently demonstrates the minimum requirements and necessary conditions for conducting radiological surveys by a person carrying a radiation detector(s). The Pacific Northwest National Laboratory (PNNL) evaluated the use of an unoccupied aerial vehicle (UAV) to conduct radiological surveys that could be used in decommissioning to potentially reduce time, cost, and worker safety compared to current survey methods. The objective of this project was to evaluate the performance and limitations of a UAV to support a decommissioning radiological survey and compare it to a radiological survey conducted by a human. The primary research questions of interest evaluated were: 1. Did observed UAV paths differ from human paths and, if so, how much? 2. Did survey path deviation affect survey results and, if so, how? 3. Were radiological measurements from human and UAV surveys significantly different? To answer these research questions, an experimental field was set up at PNNL’s 3440 test track, and it included radiological sources commonly surveyed during decommissioning: cobalt-60 (Co-60), cesium-137 (Cs-137), and americium-241 (Am-241). Nine check sources (three each of Am-241, Cs-137, and Co-60) with activities ranging from 3.54 µCi to 39.34 µCi were set over a path that also included an area for measuring background radiation. An Aurelia X6 UAV coupled with a GPS and lidar unit was used to conduct the radiological surveys. UAV and human surveys were conducted using two different NaI(Tl) scintillation radiation detectors (2 in. × 2 in. Ludlum, Inc. and 2 in. × 0.04 in. Alpha Spectra, Inc.) at a travel velocity of approximately 0.2 m/s at a low (15–40 cm median altitude) or high (87–105 cm median altitude) survey altitude. Since the survey velocity and altitude parameters were atypical for normal UAV operations, testing was done prior to conducting the radiological surveys to establish airworthiness, evaluate the navigation system, and establish flight control. Human and UAV surveys were paired according to the detector type and altitude regime to compare the survey data. The results of this proof-of-concept research determined that the UAV and human surveys followed similar survey paths and detected the radiological sources with no significant statistical difference (in 33 out of 36 surveys). However, further research is needed prior to deploying UAVs for decommissioning surveys.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Yale–Potsdam Stellar Isochrones

We introduce the Yale–Potsdam Stellar Isochrones (YaPSI), a new grid of stellar evolution tracks and isochrones of solar-scaled composition. In an effort to improve the Yonsei–Yale database, special emphasis is placed on the construction of accurate low-mass models (M{sub ∗}<0.6 M{sub ⊙}), and in particular on their mass–luminosity and mass–radius relations, both crucial for characterizing exoplanet-host stars, and, in turn, their planetary systems. The YaPSI models cover the mass range 0.15–5.0 M{sub ⊙} densely enough to permit detailed interpolation in mass, and the metallicity and helium abundance ranges [Fe/H] = −1.5 to +0.3 and Y {sub 0} = 0.25–0.37 are specified independently of each other (i.e., no fixed ΔY/ΔZ relation is assumed). The evolutionary tracks are calculated from the pre-main sequence up to the tip of the red giant branch. The isochrones, with ages between 1 Myr and 20 Gyr, provide UBVRI colors in the Johnson–Cousins system, and JHK colors in the homogenized Bessell and Brett system, derived from two different semi-empirical T{sub eff}–color calibrations from the literature. We also provide utility codes, such as an isochrone interpolator, in age, metallicity, and helium content, and an interface of the tracks with an open-source Monte Carlo Markov-Chain tool for the analysis of individual stars. Finally, we present comparisons of the YaPSI models with the best empirical mass–luminosity and mass–radius relations available to date, as well as isochrone fitting of well-studied stellar clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Photon Source injection related Simulation and Measurement

Injection efficiency is one of the key factors in ensuring successful operation of storage ring light sources. In this paper, injection simulation and measurement studies at the Advanced Photon Source will be presented. The tracking simulations and measurements are compared in terms of the dynamic aperture and injection efficiency. Injection efficiency is also measured on the betatron tunes space and on different stored beam orbits.

Sun, Yipeng↗

Fringe biasing: A variance reduction technique for optically thick meshes

Fringe biasing is a stratified sampling scheme applicable to Monte Carlo thermal radiation transport codes. The thermal emission source in optically thick cells is partitioned into separate contributions from the cell interiors (where the likelihood of the particles escaping the cells is virtually zero) and the 'fringe' regions close to the cell boundaries. Thermal emission in the cell interiors can now be modelled with fewer particles, the remaining particles being concentrated in the fringes so that they are more likely to contribute to the energy exchange between cells. Unlike other techniques for improving the efficiency in optically thick regions (such as random walk and discrete diffusion treatments), fringe biasing has the benefit of simplicity, as the associated changes are restricted to the sourcing routines with the particle tracking routines being unaffected. This paper presents an analysis of the potential for variance reduction achieved from employing the fringe biasing technique. The aim of this analysis is to guide the implementation of this technique in Monte Carlo thermal radiation codes, specifically in order to aid the choice of the fringe width and the proportion of particles allocated to the fringe (which are interrelated) in multi-dimensional simulations, and to confirm that the significant levels of variance reduction achieved in simulations can be understood by studying the behaviour for simple test cases. The variance reduction properties are studied for a single cell in a slab geometry purely absorbing medium, investigating the accuracy of the scalar flux and current tallies on one of the interfaces with the surrounding medium. (authors)

97 MATHEMATICS AND COMPUTING↗

Multi-INT Signature Collection and Exploitation for Security: Improving Discrimination, Analyses, and Passive Tracking Capabilities for Time- and Distance-Varying Signatures in the Seismoacoustic Regime

This project demonstrates the feasibility of a passive tracking capability for ground-based and airborne moving sources using multiple information streams from acoustic and seismic signals. These moving source types are characterized by their variability with time and distance (exemplified but not limited to the familiar doppler shift of a passing vehicle) and the signatures used for detection should have similar characteristics. We have demonstrated that time-varying sensor signatures (TVS) combined with time-stable sensor signatures provide a more complete understanding of moving source behavior. Importantly, we have collected a new, relevant LANL dataset of moving sources (small uncrewed aerial vehicle flights and ground vehicle movement), developed new signatures, and demonstrated the capability to identify, track and forecast the position of these moving sources.

42 ENGINEERING↗

Measurement of the temperature of an ultracold ion source using time-dependent electric fields

We report on a measurement of the characteristic temperature of an ultracold rubidium ion source, in which a cloud of laser-cooled atoms is converted to ions by photo-ionization. Extracted ion pulses are focused on a detector with a pulsed-field technique. The resulting experimental spot sizes are compared to particle-tracking simulations, from which an effective source temperature T = (3 {+-} 2) mK and the corresponding transversal reduced emittance {epsilon}{sub r} = 1.4 x 10{sup -8} m rad {radical}(eV) are determined. Space charge effects that may affect the measurement are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early science with the Korean VLBI network: evaluation of system performance

We report the very long baseline interferometry (VLBI) observing performance of the Korean VLBI Network (KVN). The KVN is the first millimeter-dedicated VLBI network in East Asia. The KVN consists of three 21 m radio telescopes with baseline lengths in a range of 305-476 km. The quasi-optical system equipped on the antennas allows simultaneous observations at 22, 43, 86, and 129 GHz. The first fringes of the KVN were obtained at 22 GHz on 2010 June 8. Test observations at 22 and 43 GHz on 2010 September 30 and 2011 April 4 confirmed that the full cycle of VLBI observations works according to specification: scheduling, antenna control system, data recording, correlation, post-correlation data processing, astrometry, geodesy, and imaging analysis. We found that decorrelation due to instability in the hardware at times up to 600 s is negligible. The atmosphere fluctuations at KVN baseline are partly coherent, which allows us to extend integration time under good winter weather conditions up to 600 s without significant loss of coherence. The post-fit residuals at KVN baselines do not exhibit systematic patterns, and the weighted rms of the residuals is 14.8 ps. The KVN is ready to image compact radio sources both in snapshot and full-track modes with residual noise in calibrated phases of less than 2 deg at 22 and 43 GHz and with dynamic ranges of ∼300 for snapshot mode and ∼1000 for full-track mode. With simultaneous multi-frequency observations, the KVN can be used to make parsec-scale spectral index maps of compact radio sources.

79 ASTRONOMY AND ASTROPHYSICS↗

PyFLEXTRKR: a flexible feature tracking Python software for convective cloud analysis

Abstract. This paper describes the new open-source framework PyFLEXTRKR (Python FLEXible object TRacKeR), a flexible atmospheric feature tracking software package with specific capabilities to track convective clouds from a variety of observations and model simulations. This software can track any atmospheric 2D objects and handle merging and splitting explicitly. The package has a collection of multi-object identification algorithms, scalable parallelization options, and has been optimized for large datasets including global high-resolution data. We demonstrate applications of PyFLEXTRKR on tracking individual deep convective cells and mesoscale convective systems from observations and model simulations ranging from large-eddy resolving (∼100s m) to mesoscale (∼10s km) resolutions. Visualization, post-processing, and statistical analysis tools are included in the package. New Lagrangian analyses of convective clouds produced by PyFLEXTRKR applicable to a wide range of datasets and scales facilitate advanced model evaluation and development efforts as well as scientific discovery.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Pd/D co-deposition and DT neutron generated triple tracks observed in CR-39 detectors

Solid state nuclear track detectors (SSNTDs), such as CR-39, have been used to detect energetic charged particles and neutrons. Of the neutron and charged particle interactions that can occur in CR-39, the one that is the most easily identifiable is the carbon breakup reaction. The observation of a triple track, which appears as three alpha particle tracks breaking away from a center point, is diagnostic of the 12C(n, n')3α carbon breakup reaction. Such triple tracks have been observed in CR-39 detectors that have been used in Pd/D co-deposition experiments. In this communication, triple tracks in CR-39 detectors observed in Pd/D co-deposition experiments are compared with those generated upon exposure to a DT neutron source. It was found that both sets of tracks were indistinguishable. Both symmetric and asymmetric tracks were observed. Using linear energy transfer (LET) curves and track modeling, the energy of the neutron that created the triple track can be estimated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗