Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Use of the High-density UN Fuel in Heat-pipe Microreactors

Heat-pipe microreactors (HPMRs) are very small-scale nuclear reactors that employ heat pipes for heat removal. HPMRs can be easily integrated with other forms of renewable energies, used for emergency responses to disaster relief zones, deployed in remote locations not connected to the grid, and removed from sites and replaced by new ones. HPMRs can also be used for space missions as heat pipes do not rely on gravity for heat transfer. Conventional fuel materials, such as UO 2 and UCO, are currently considered in most existing HPMR designs, but ceramic UN fuel that has high uranium density, high thermal conductivity, and a high melting point may become a better fuel candidate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploration of Heat-Driven Ejector High-Temperature Heat Pumps

Heat-driven ejector heat pumps use a supersonic ejector as a thermo-compressor to replace the mechanical compressor. Supersonic ejectors have many advantages in high-temperature heat pump (HTHP) applications, including high operating temperature tolerance, no need for lubrication, low maintenance, and low cost. The coefficient of performance of ejector HTHPs could be improved by selecting binary fluids with unique thermodynamic properties. Although supersonic ejectors have been widely used in refrigeration systems, their application in spaces and water heating is limited. This study explores the theoretical potential of ejector HTHPs with a sink temperature of 100°C–130°C and a lift temperature of 10°C–30°C. Ejector HTHPs were evaluated with single-fluid ejectors (SFEs) and binary-fluid ejectors (BFEs). A comprehensive, geometry-free theoretical model of BFEs was developed to predict the theoretical maximum entrainment ratios. HFE7500 and R718 (water) were selected as working fluids for SFEs and BFEs. SFEs operating with R718 provided a higher coefficient of performance of ejector HTHPs than SFEs operating with HFE7500 and BFEs. This study preliminarily demonstrates the technical potential of ejector HTHP applications in recovering moderate-temperature heat sources

Wang, Pengtao↗

Urban Forests as Main Regulator of the Evaporative Cooling Effect in Cities

Abstract Higher temperatures in urban areas expose a large fraction of the human population to potentially dangerous heat stress. Green spaces are promoted worldwide as local and city‐scale cooling strategies but the amount, type, and functioning of vegetation in cities lack quantification and their interaction with urban climate in different settings remains a matter of debate. Here we use state‐of‐the‐art remote sensing data from 145 city clusters to disentangle the drivers of surface urban heat islands (SUHI) intensity and quantify urban‐rural differences in vegetation cover, species composition, and evaporative cooling. We show that nighttime SUHIs are affected mostly by abiotic factors, while daytime SUHIs are highly correlated with vegetation characteristics and the wetness of the background climate. Magnitude and seasonality of daytime SUHIs are controlled by urban‐rural differences in plant transpiration and leaf area, which explain the dependence of SUHIs on wetness conditions. Leaf area differences are caused primarily by changes in vegetation type and a loss of in‐city forested areas, highlighting the importance of maintaining “natural reserves” as a sustainable heat mitigation policy.

Paschalis, Athanasios↗

Methane pyrolysis by Joule heating for graphitic carbon and hydrogen production

The global energy transition toward sustainability requires technologies that can decarbonize energy carriers and fuels while producing valuable materials. Methane, a primary component of natural gas, is both a high-energy-density fuel and a significant greenhouse gas. This study reports an approach for methane pyrolysis utilizing Joule heating within the deposition substrate to drive the endothermic reaction. With electric current passing through a resistive porous carbon cloth, heat is generated to break C-H bonds of methane molecules. Here, the decomposition of methane as it flows through the cloth results in hydrogen production and the formation of conformally layered graphite around the carbon fibers. The effects of input power, chamber pressure, feedstock flow rate, and process duration on hydrogen and graphite production are characterized via in situ mass spectrometry and laser absorption spectroscopy, resulting in methane conversion rates up to 88%, with hydrogen and carbon yields of 82% and 72%, respectively. Material characterization verifies uniform high-quality graphite deposition, with a Raman I D /I G ratio of 0.1 and 3.38 Å d-spacing. This Joule heating method for catalyst-free methane pyrolysis offers the potential for advancing hydrogen production technology by simultaneously producing valuable materials such as solid graphite, thus enhancing the economic viability of the fuel decarbonization process.

Energy Resources↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of the EIC hadron storage ring stripline injection kicker with a novel impedance tuning capability

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will be a high luminosity (~10 34 cm –2 s –1 ) nuclear science facility. To facilitate EIC experiments, the existing yellow ring of the Relativistic Heavy Ion Collider (RHIC) will be reconfigured to serve as the Hadron Storage Ring (HSR). Designing a stripline injection kicker for the HSR beams, with high magnetic rigidity (~ 82 Tm), poses some technical challenges due to the required large pulsed voltage with long flattop duration, very fast rise time, expected shorter bunch spacing, and potential heating due to higher peak current. In addition, minimizing impedance mismatch in the transition region between the feedthrough and the stripline electrode is challenging. This paper focuses on the mechanical design and optimization of the HSR injection kicker, highlighting a novel impedance tuning capability achieved through an innovative kicker aperture adjustment mechanism. We comprehensively cover the design, including impedance optimization (both beam coupling and characteristic), beam-induced heating, and thermal analysis, and investigation of the maximum electric field due to high voltage signal excitation to ensure safe and reliable operation.

43 PARTICLE ACCELERATORS↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefit FOA FY2015 - Solid State Magnetocaloric Air Conditioner (Final Report)

The active magnetic refrigeration (AMR) cycle holds great promise to reduce energy consumption of space cooling and heating. It is estimated that it could achieve up to 25% improvement in energy efficiency over conventional vapor compression systems. Prototypes have been built and demonstrated the working principles and energy benefits of the technology. These prototypes however were of low specific cooling power, defined as cooling power obtainable from unit mass of magnetocaloric materials (MCM). Specific cooling power is inversely proportional to the cost of the system. Therefore, for the magnetocaloric technology to be commercially viable, the specific cooling power must be increased. To increase the specific cooling power, for any MCM, the frequency of operation must increase. However, the maximum frequency that an AMR can operate at is limited by the residence time that is required to transfer heat in and out of the regenerator during the cold and got blows. This time length is dependent on the thermal conductivity of the heat transfer medium. The higher the thermal conductivity of the heat transfer medium, the faster heat can be transferred between the medium and the MCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A software package for plasma facing component analysis and design: the Heat flux Engineering Analysis Toolkit (HEAT)

The engineering limits of plasma facing components (PFCs) constrain the allowable operational space of tokamaks. Poorly managed heat fluxes that push the PFCs beyond their limits not only degrade core plasma performance via elevated impurities, but can also result in PFC failure due to thermal stresses or melting. Simple axisymmetric assumptions fail to capture the complex interaction between 3D PFC geometry and 2D or 3D plasmas. This results in fusion systems that must either operate with increased risk or reduce PFC loads, potentially through lower core plasma performance, to maintain a nominal safety factor. High precision 3D heat flux predictions are necessary to accurately ascertain the state of a PFC given the evolution of the magnetic equilibrium. A new code, the Heat flux Engineering Analysis Toolkit (HEAT), has been developed to provide high precision 3D predictions and analysis for PFCs. HEAT couples many otherwise disparate computational tools together into a single open source python package. Magnetic equilibrium, engineering CAD, finite volume solvers, scrape off layer plasma physics, visualization, high performace computing, and more, are connected in a single web-based user interface. Linux users may use HEAT without any software prerequisites via an appImage. This manuscript introduces HEAT, discusses the software architecture, presents first HEAT results, and outlines physics modules in development.

divertor physics↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pedestal formation via different trajectories in the stability space in response to the timing scan of neutral beam heating in DIII-D

The frequency of type-I ELMs decreases as the initiation of the neutral beam injection (NBI) heating is delayed with respect to the time when plasma current (I p ) reaches flat-top in the ITER Baseline Scenario discharges in DIII-D. Henceforth, the time gap between the NBI initiation and I p flat-top will be referred to as “heating delay.” As the heating delay is modified, pedestal formation follows different trajectories in the edge current density–pedestal pressure gradient (j edge -∇p e ped ) space from the L-H transition toward the first ELM event. During the stationary phase after the first ELM, the ELM frequency (f ELM ) decreases by a factor of ~2 as the heating delay is increased. A longer pedestal recovery time in the inter-ELM period is observed for the low f ELM discharges as compared to the high f ELM discharges. Both low and high f ELM discharges show nearly identical profiles of electron density and temperature and have a similar MHD stability just before an ELM crash. However, a marked difference is observed in the magnetic spectrogram of the high and low f ELM discharges in response to the variation in the heating delay. The main difference is in the 200–400 kHz range of the magnetic spectra. A quasi-coherent mode (QCM) at 220 kHz and weaker broadband fluctuations are observed in the high f ELM discharges, while only strong broadband fluctuations are prevalent in the low f ELM discharges. ELM-synchronized analysis shows that the time evolution of these modes is different for the high and low f ELM discharges. The localization of both these modes is confirmed at the maximum gradient region of the pedestal. We hypothesize that these modes cause important pedestal transport and that the difference in the pedestal recovery of the high and low f ELM discharges is a result of the difference in transport driven by these modes, as they change with changes in the heating delay. It is demonstrated experimentally for the first time that discharges with similar pedestal parameters can carry the history of the heating delay into the stationary phase and that changes in turbulent-driven transport are a likely cause of changes in f ELM observed with variations of heating delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature-Dependent Thermal and Mechanical Properties of a Wire Arc Additively Manufactured Low Transformation Temperature Steel

Recent research has studied the use of low transformation temperature (LTT) martensite steel as feedstock for wire arc additive manufacturing (WAAM) and low tensile residual stresses or compressive residual stresses were detected in the printed walls. These residual stress states help to improve printed product properties such as fatigue strength and corrosion resistance. However, the thermal and mechanical properties of WAAM printed LTT martensite steel walls are largely unknown. In this work, a printed LTT martensite steel was characterized for its thermal, metallurgical, and mechanical behavior at room and elevated temperatures. The temperature-dependent specific heat capacity, thermal expansion, atomic lattice spacing, and tensile properties were measured during both heating and cooling and related to observed microstructural features and computational thermodynamics predictions. These results revealed a large hysteresis in the martensitic transformation, with a martensite start temperature of 240 °C and austenite start temperature of 680 °C. Additional thermal cycles and specimen orientation did not affect the printed specimen austenite and martensite transformations. However, it was observed that the printed metal may exhibit tempering embrittlement at about 350 °C but further studies are needed to confirm that. Further, these results suggest that a temperature control of 250 °C to 350 °C during WAAM is needed to maximize the stress reduction potential of the LTT250 martensite steel. Opportunities for future implementation of LTT martensite steels and optimization of additive manufacturing process conditions are identified.

36 MATERIALS SCIENCE↗

Pumped Thermal Energy Storage With Liquid Storage

Pumped Thermal Energy Storage (PTES) uses electricity to power a heat pump; transferring heat from a cold space to a hot space forms a hot and a cold thermal reservoir, thereby storing energy. To discharge, the temperature difference between the two stores is used to drive a heat engine which generates electricity. In this chapter, PTES systems which store energy in liquids will be described. The chapter will concentrate on Joule-Brayton power cycles with molten salt storage. Part-load operation of Joule-Brayton PTES with liquid storage can be managed with "inventory control," and it is demonstrated that this control method leads to relatively good performance over a range of operating points.

Carnot batteries↗

Next-Gen RTG Peltier Cooling Testing [Poster]

The Peltier Cooling Test was developed and performed on a General Purpose Heat Source Radioisotope Thermoelectric Generator (GPHS-RTG) for the first time to support the refurbishment and recertification of a legacy flight unit. The GPHS-RTG flight units generate power for NASA space missions by converting heat from decaying Plutonium-238 into electricity using 572 thermocouples. The Peltier test successfully verified the electrical connections of the thermocouples by visually observing their thermal behavior under an applied current. Knowledge of the thermocouple electrical connections will be critical as the refurbishment and recertification plan moves forward.

42 ENGINEERING↗