Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An extreme ultraviolet spectrometer experiment for the Shuttle Get Away Special Program

An extreme ultraviolet (EUV) spectrometer experiment operated successfully during the STS-7 mission in an experiment to measure the global and diurnal variation of the EUV airglow. The spectrometer is an F 3.5 Wadsworth mount with mechanical collimator, a 75 x 75 mm grating, and a bare microchannel plate detector providing a spectral resolution of 7 X FWHM. Read-out of the signal is through discrete channels or resistive anode techniques. The experiment includes a microcomputer, 20 Mbit tape recorder, and a 28V, 40 Ahr silver-zinc battery. It is the first GAS payload to use an opening door. The spectrometer's 0.1 x 4.2 deg field of view is pointed vertically out of the shuttle bay. During the STS-7 flight data were acquired continuously for a period of 5 hours and 37 minutes, providing spectra of the 570 A to 850 A wavelength region of the airglow. Five diurnal cycles of the 584 A emission of neutral helium and the 834 A emission of ionized atomic oxygen were recorded. The experiment also recorded ion events and pressure pulses associated with thruster firings. The experiment is to fly again on Mission 41-F.

Conway, R. R.↗

Variable line-space gratings - New designs for use in grazing incidence spectrometers

An account is given of a fundamentally different approach to the use of variable line-space gratings for grazing incidence spectrometers. In the new approach, the gratings are flat and they are placed to intercept the converging beam from a collecting mirror rather than the diverging beam from a slit. This results in (1) small aberrations over a wide instantaneous range in wavelength, (2) a modest required variation in line spacing across the ruled width, (3) a simultaneous minimization of both the spectral and image height aberrations, and (4) a completely stigmatic zero order image. The slitless arrangement common to these designs is very compact, having no additional length behind the focal plane of the collecting mirror. In-plane and conical fan designs are considered. One combination design, in the form of an echelle spectrometer, is discussed. The designs are considered to represent ideal candidates for moderate to high resolution spectrometers on such missions as the Far Ultraviolet Spectroscopic Explorer (FUSE, now Columbus) and the Advanced X-ray Astrophysics Facility (AXAF).

Hettrick, M. C.↗

Cooled grating infrared spectrometer for astronomical observations

A liquid helium-cooled infrared spectrometer for the 16 to 50 micron range is described. The instrument has six detectors, three each of Si:Sb and Ge:Ga and two diffraction gratings mounted back-to-back. Cold preoptics are used to match the spectrometer to the telescope. In its nominal configuration the system resolution is 0.03 micron from 16 to 30 microns and 0.07 micron from 28 to 50 microns. A cooled filter wheel is used to change order sorting filters. The gratings are driven by a steel band and gear train operating at 4 K. The detector outputs are amplified by a TIA, employing a matched pair of JFETs operating at 70 K inside the dewar. The external warm electronics include a gain stage for the TIA and dc-coupled gating circuit to remove charged-particle (cosmic-ray secondary)-induced noise spikes. The gating circuit reduces the overall system noise by a factor of two when the spectrometer is used on NASA's Kuiper Airborne Observatory. Sample spectra are presented and the deglitcher performance is illustrated.

Houck, J. R.↗

Mobile spectrometer measures radar backscatter

The present article is concerned with a helicopter-borne spectrometer (Heloscat), which has been developed to permit high-quality scattering measurements from a mobile platform at remote sites. The term 'spectrometer' referes to a class of scatterometers. The term 'scatterometer' is employed to denote a specialized radar for measuring scattering coefficients as a function of angle. A spectrometer, on the other hand, is a scatterometer which can measure backscatter at several frequencies. The Heloscat system is discussed, taking into account two antennas, RF hardware, and an externally mounted pendulum for angle encoding. A dual-antenna configuration is used for cross-polarized measurements, while a single-antenna system is used for like-polarized measurements. Attention is also given to oscillator characteristics, efficient data handling, and aspects of calibration.

Gogineni, S.↗

Instrumental background in balloon-borne gamma-ray spectrometers and techniques for its reduction

Instrumental background in balloon-borne gamma-ray spectrometers is presented. The calculations are based on newly available interaction cross sections and new analytic techniques, and are the most detailed and accurate published to date. Results compare well with measurements made in the 20 keV to 10 MeV energy range by the Goddard Low Energy Gamma-ray Spectrometer (LEGS). The principal components of the continuum background in spectrometers with GE detectors and thick active shields are: (1) elastic neutron scattering of atmospheric neutrons on the Ge nuclei; (2) aperture flux of atmospheric and cosmic gamma rays; (3) beta decays of unstable nuclides produced by nuclear interactions of atmospheric protons and neutrons with Ge nuclei; and (4) shield leakage of atmospheric gamma rays. The improved understanding of these components leads to several recommended techniques for reducing the background.

Gehrels, N.↗

A computer controlled mass spectrometer system for investigating the decomposition of non-metallic materials under atmospheric conditions

A PDP 11/23 quadrupole mass spectrometer system was coupled to a nondiscriminating gas inlet system permitting gases at atmospheric pressure to be admitted into a high vacuum chamber containing the ion source of the mass spectrometer without separation of the gaseous components. The resolution of related software problems has resulted in a convenient computer-mass spectrometer system capable of generating masses, relative intensities and related data on the gaseous products resulting from the atmospheric thermal decomposition of nonmetallic materials.

Thompson, J. M.↗

HgCdTe infrared focal plane arrays for imaging spectrometer applications

It is pointed out that the development of two-dimensional infrared focal plane arrays (FPAs) offers new alternatives in imaging and remote sensing. Attention is given to an imaging spectrometer which represents a new concept exploiting two-dimensional arrays. This instrument is to be used for the remote sensing of the earth on the basis of a utilization of reflected sunlight in both the visible (VIS) and short wavelength infrared (SWIR). The imaging spectrometer concept is to make it possible to obtain contiguous spectral coverage at high resolution without having to use increasingly complex scanners. The concept utilizes a prism spectrometer to disperse the image of the slit across the area arrays in the focal plane. The focal plane consists of silicon CCDs for the VIS and near infrared portions of the spectrum and HgCdTe hybrid arrays for the SWIR.

Rode, J. P.↗

High-performance double-focusing mass spectrometer

Double focusing was first employed when mass spectrometers of a simpler design were not capable any longer to satisfy increasing demands in mass spectroscopy. One of the successful instruments of the 1930's was the mass spectrometer designed by Mattauch and Herzog (1934). The compactness of the Mattauch-Herzog geometry became particularly important in connection with studies involving the employment of rockets, satellites, or space probes. Another advantage of the considered spectrometer is related to the capability of measuring several masses of ions simultaneously. The instrument design was, therefore adopted for some rocket flights to the upper atmosphere, the investigation of the upper atmosphere of Mars, and for studying the upper atmosphere of Venus. Attention is given to laboratory applications involving the instrument in a somewhat enlarged version, and aspects of instrument operation and performance.

Nier, A. O.↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗

A liquid helium cooled Fabry-Perot infrared spectrometer

A liquid-helium-cooled Fabry-Perot infrared spectrometer offering excellent performance in the middle infrared range has been constructed and tested. The spectrometer is based on newly developed superconducting actuators which control the alignment and tuning at 4.2 K with virtually no power dissipation within the instrument. Depending on the availability of high-quality etalons, this type of spectrometer should be useful in a wide range of infrared astronomical spectroscopy applications.

Nishimura, T.↗

AE and DE mass spectrometer observations relevant to the shuttle glow

Recent work suggested that NO2 may be responsible for the observed continuum glow near surfaces of the space shuttle. The observations of atomic nitrogen (N) are reported at shuttle altitudes using mass spectrometers, giving special attention to the surface reactions of N relevant to the production of NO2 on spacecraft surfaces. Data from two semi-open sources mass spectrometers, the OSS instruments on the Atmosphere Explorer-C and -D satellites, and the closed source Neutral Atmospheric Composition Spectrometer (NACS) on the Dynamic Explorer-2 satellite are presented to show the similar behavior of NO in each case and the contrasting behavior of NO2. Although signals of NO and NO2 are highly dependent on surface temperature and surface composition, it appears that direct exposure of ion source surfaces to rammed gas is a necessary condition for the production of large amounts of NO2. Evidence that elevated surface temperatures can significantly reduce the production of NO2, likely by causing more rapid desorption of NO from these surfaces, is presented.

Engebretson, M. J.↗

Iterative and function-continuation Fourier deconvolution methods for enhancing mass spectrometer resolution

Mass spectrometer data in the form of ion current versus mass-to-charge ratio often include overlapping mass peaks, especially in low- and medium-resolution instruments. Numerical deconvolution of such data effectively enhances the resolution by decreasing the overlap of mass peaks. In this paper two approaches to deconvolution are presented: a function-domain iterative technique and a Fourier transform method which uses transform-domain function-continuation. Both techniques include data smoothing to reduce the sensitivity of the deconvolution to noise. The efficacy of these methods is demonstrated through application to representative mass spectrometer data and the deconvolved results are discussed and compared to data obtained from a spectrometer with sufficient resolution to achieve separation of the mass peaks studied. A case for which the deconvolution is seriously affected by Gibbs oscillations is analyzed.

Ioup, J. W.↗

Automated calibration of a flight particle spectrometer

An automatic calibration system was designed for use in the vacuum facility at the Space Science Laboratory of the Marshall Space Flight Center. That system was developed and used in the intervening winter to calibrate the ion spectrometer that eventually flew in May 1986 aboard the NASA project, CRIT 1. During this summer, it is planned to implement the calibration of both an ion and electron spectrometer of a new design whose basic elements were conceived during the winter of 1985 to 1986. This spectrometer was completed in the summer and successfully mounted in the vacuum tank for calibration. However, the source gate valve malfunctioned, and, at the end of the summer, it still needed a replacement. During the inevitable delays in the experimental research, the numerical model of the Critical Velocity effect was completed and these results were presented.

Torbert, Roy B.↗

A geostationary imaging spectrometer TOMS instrument

One design for a geostationary Total Ozone Mapping Spectrometer (TOMS) with many desirable features is an imaging spectrometer. A preliminary study makes use of a 0.25 m Czerny-Turner spectrometer with which the Earth is imaged on a charge-coupled device (CCD) in dispersed light. The wavelength is determined by a movable grating which can be set arbitrarily by ground control. The signal integration time depends on wavelength but this system allows arbitrary timing by command. Special circumstances such as a requirement to track a low-lying sulfur dioxide cloud or a need to discriminate high level ozone from total ozone at midlatitudes could be obtained by adding a particular wavelength to the normally pre-programmed time sequence. The incident solar irradiance is measured by deploying a diffuser plate in the field of view. Individual detector elements correspond to scene elements in which the several wavelengths are serially sampled and the Earth radiance is compared to the incident sunlight. Thus the problem of uncorrelated drift of multiple detectors is removed.

Krueger, Arlin J.↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

The UCB/MPE Cassegrain Submillimeter Heterodyne Spectrometer

The UCB/MPE Submillimeter Heterodyne Spectrometer is a system for astronomical spectroscopy in the high-frequency atmospheric windows from 500 to 1000 GHz. It contains a molecular laser local oscillator, a cooled Schottky open structure mixer, a quasi-optical coupling system, and an acoustooptical spectrometer. The compact receiver mounts at the Cassegrain focus of large infrared astronomical telescopes. The receiver noise temperature on the telescope is approximately 3500 K (DSB) during observations of the CO J = 7-6 line at 806.652 GHz. The spectrometer's frequency resolution and instantaneous bandwidth (less than 2 MHz resolution across 1.1 GHz) are well suited for observations of molecular emission lines from a variety of astronomical sources.

Harris, A. I.↗

Imaging spectrometers for terrestrial and planetary remote sensing - A progress report

Attention is given to two major design approaches, the 'whiskbroom' and the 'pushbroom', in the present consideration of imaging spectroscopy for both planetary and terrestrial missions. A near-IR mapping spectrometer has been developed for the Galileo Jupiter Orbiter Mission; on the basis of this design, and incorporating focal plane array technology improvements, a family of imaging spectrometers exemplified by the Visual and IR Mapping Spectrometer is under development for other planetary missions.

Wellman, John B.↗

Preliminary analysis of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) for mineralogic mapping at sites in Nevada and Colorado

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data for sites in Nevada and Colorado were evaluated to determine their utility for mineralogical mapping in support of geologic investigations. Equal energy normalization is commonly used with imaging spectrometer data to reduce albedo effects. Spectra, profiles, and stacked, color-coded spectra were extracted from the AVIRIS data using an interactive analysis program (QLook) and these derivative data were compared to Airborne Imaging Spectrometer (AIS) results, field and laboratory spectra, and geologic maps. A feature extraction algorithm was used to extract and characterize absorption features from AVIRIS and laboratory spectra, allowing direct comparison of the position and shape of absorption features. Both muscovite and carbonate spectra were identified in the Nevada AVIRIS data by comparison with laboratory and AIS spectra, and an image was made that showed the distribution of these minerals for the entire site. Additional, distinctive spectra were located for an unknown mineral. For the two Colorado sites, the signal-to-noise problem was significantly worse and attempts to extract meaningful spectra were unsuccessful. Problems with the Colorado AVIRIS data were accentuated by the IAR reflectance technique because of moderate vegetation cover. Improved signal-to-noise and alternative calibration procedures will be required to produce satisfactory reflectance spectra from these data. Although the AVIRIS data were useful for mapping strong mineral absorption features and producing mineral maps at the Nevada site, it is clear that significant improvements to the instrument performance are required before AVIRIS will be an operational instrument.

Kruse, Fred A.↗