Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bayesian Model for HOPE Mass Spectrometers on Van Allen Probes

Space instruments rely heavily on modeling to predict and understand the instrument response, enabling a determination of the capabilities and resolution. The Bayesian approach provides a framework to incorporate prior knowledge and propagate uncertainty to predict the instrument response. We present an empirical Bayes model for the end-to-end performance of the Helium, Oxygen, Proton, and Electron mass spectrometers aboard the Van Allen Probes mission. In this model, we use a combination of external modeling, laboratory calibration, and expert opinion to construct the time-of-flight spectra and demonstrate good agreement with on-orbit data. The empirical Bayes model is applied to explore doubly charged ions and carbon, nitrogen, oxygen discrimination during the Van Allen Probes mission.

47 OTHER INSTRUMENTATION↗

Comprehensive Characterization of Water Group Ion Composition and Distributions in Saturn's Magnetosphere With Cassini Plasma Spectrometer Data

Saturn's magnetosphere is continuously supplied with neutrals from the Enceladus plume and the icy rings, which undergo ionization and charge-exchange to form a complex water-group plasma environment. While the Cassini Plasma Spectrometer (CAPS) instrument has provided extensive compositional information, detailed separation of individual water-group ion species in time-of-flight (TOF) data has not previously been achieved. In this study, we perform forward modeling of CAPS-IMS energy-per-charge (E/Q) and TOF spectra obtained between 2004 and 2012 to resolve O + , OH + , H 2 O + , and H 3 O + and to characterize their plasma properties, including number density, temperature, and thermodynamic κ. Our results demonstrate that O + is the dominant thermal ion species throughout Saturn's magnetosphere, comprising up to ∼70% of the total ion population beyond ∼5 Saturn radii (R S ). In contrast, molecular ions such as OH + , H 2 O + , and H 3 O + dominate closer to Enceladus but rapidly dissociate into atomic ions between ∼5 and 10 R S . This radial region is also characterized by the steepest increase in plasma flow speed, which rises from ∼40% to ∼80% of rigid corotation. Simultaneously, ion velocity distributions approach Maxwell–Boltzmann equilibrium, as indicated by high kappa values. These findings provide new constraints on the ion–neutral chemistry that regulates the balance between molecular and atomic ions in Saturn's magnetosphere. They also emphasize the critical role of the 5–10 R S region as a transition zone for both plasma composition and dynamics. Our results refine previous CAPS-based studies and underscore the need to incorporate seasonal variability and ionospheric coupling into future global models of Saturn's plasma environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast and deep phosphoproteome analysis with the Orbitrap Astral mass spectrometer

Owing to its roles in cellular signal transduction, protein phosphorylation plays critical roles in myriad cell processes. That said, detecting and quantifying protein phosphorylation has remained a challenge. We describe the use of a novel mass spectrometer (Orbitrap Astral) coupled with data-independent acquisition (DIA) to achieve rapid and deep analysis of human and mouse phosphoproteomes. With this method, we map approximately 30,000 unique human phosphorylation sites within a half-hour of data collection. The technology is benchmarked to other state-of-the-art MS platforms using both synthetic peptide standards and with EGF-stimulated HeLa cells. We apply this approach to generate a phosphoproteome multi-tissue atlas of the mouse. Altogether, we detect 81,120 unique phosphorylation sites within 12 hours of measurement. With this unique dataset, we examine the sequence, structural, and kinase specificity context of protein phosphorylation. Finally, we highlight the discovery potential of this resource with multiple examples of phosphorylation events relevant to mitochondrial and brain biology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of the time-of-flight neutron scattering cross-section data for light water measured at the SEQUOIA spectrometer, Spallation Neutron Source (SNS)

Thermal neutron scattering cross-section data for light water available in the major nuclear data libraries observes significant differences especially at reactor operating temperatures. During the past few years there has been a renewed interest in reviewing the existing thermal scattering models and generating more accurate and reliable thermal scattering cross sections using existing experimental data and in some cases based on Molecular Dynamics (MD) simulations. There is a need for performing new time-of-flight experiments at high temperatures and pressures, to have a better understanding of the physics involved in the scattering process that could help improve the existing TSL data.Lack of experimental thermal scattering data for light water at high temperatures led to a new measurement campaign within the INSIDER project at the Institut de radioprotection et de sûreté nucléaire (IRSN). Double differential scattering cross section for light water have been measured at the SEQUOIA spectrometer based at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, United States. Several measurements have been carried out at different temperatures and pressures corresponding to liquid light water. Measurements at five different incident neutron energies Ei (8, 60, 160, 280 and 800 meV) have been carried out to help exploring different regions of the frequency spectrum. This paper presents the analysis of the dynamic structure factor and the derived frequency spectrum of light water. The analysis of the experimental data would provide one with better confidence, the behavior of thermal scattering cross sections for light water at high temperatures, knowledge of which is very important for the design of novel reactors as well as existing pressurized water reactors.

Jaiswal, V↗

Thermal scattering law for ice based on neutron time-of-flight experiments carried out at the SEQUOIA spectrometer at the Oak Ridge National Laboratory

Precise estimation of neutron thermalization in moderators relies on high-fidelity thermal scattering cross-section data governed by the thermal scattering law (TSL). The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) has been working on the development of improved TSL for light water ice. Many polymorphic phases of light water ice exist depending on the thermodynamic conditions. The most common type of ice at standard pressure and temperature below water freezing point (273.15 K) is ice-Ih. It is essential to have high-resolution experimental double differential data for developing and/or validating TSL for moderator materials.Existing experimental double-differential scattering data for ice-Ih are extremely sparse and of limited quality. New high-quality double-differential measurements for ice-Ih over multiple temperatures and incident neutron energies would directly support the validation and improvement of ice-Ih TSL models for criticality safety applications.Series of time-of-flight (TOF) inelastic neutron scattering experiments on ice-Ih at temperatures starting at 271 K and down to 6 K, have been carried out at the SEQUOIA spectrometer at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), United States. The experiments have been performed for incident neutron energies, Ei= 11, 55, 160, 250, and 600 meV, to explore different excitation energies in the vibrational phonon spectrum. This paper presents the thermodynamic conditions and the details of the TOF measurements on ice-Ih and the derived phonon spectrum from the experimentally measured double differential data. A study of the variation of the phonon spectrum of ice-Ih as a function of temperature is highlighted, and a preliminary TSL evaluation is developed based on the experimental phonon spectrum.

Jaiswal, V↗

A genetic algorithm approach for reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. Here, we present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources—where the exact details of spectral content were not thought to be crucial—we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

47 OTHER INSTRUMENTATION↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

Development of a deep learning based automated data analysis for step-filter x-ray spectrometers in support of high-repetition rate short-pulse laser-driven acceleration experiments

We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. Furthermore, this framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral characterization of flash and high flux x-ray radiographic sources with a magnetic Compton spectrometer

In this article, we present a new analysis method applied to revitalize permanent magnet Compton spectrometers used to measure photon energy spectra in the MeV range. The inversion of the measured electron distribution to determine the original photon distribution is achieved via a method of consistent coupled radiation transport and magnetic field mapping of the input photon spectra to the measured electron distribution. The method of linear least squares was used to perform the unfolding of the electron distribution to the initial photon spectra, without any assumptions made regarding the electron distribution. We present an application of this method to data from a nominal 19.4 MeV flash radiographic source (the first axis of the Dual Axis Radiographic Hydro-Test Facility) capable of generating 500 R @ 1 m in ~60 ns and a medical therapy source (a Scanditronix M22, Microtron) capable of variable energies with nominal endpoints of 6, 10, 15, and 20 MeV and an output of ~1000–2000 R/min @ 1 m. The results provide agreement between the modeled and unfolded experimentally measured photon spectra as quantified by statistical tests, from 1.5 to 20 MeV. Experimental results are presented as well as a discussion of the novel MCNP6-based simulations and methods for reconstruction of the spectra.

47 OTHER INSTRUMENTATION↗

Extension of charged-particle spectrometer capabilities for diagnosing implosions on OMEGA, Z, and the NIF

New designs and a new analysis technique have been developed for an existing compact charged-particle spectrometer on the NIF and OMEGA. The new analysis technique extends the capabilities of this diagnostic to measure arbitrarily shaped ion spectra down to 1 MeV with yields as low as 10 6 . Three different designs are provided optimized for the measurement of DD protons, T 3 He deuterons, and 3 He 3 He protons. The designs are highly customizable, and a generalized framework is provided for optimizing the design for alternative applications. Additionally, the understanding of the detector’s response and uncertainties is greatly expanded upon. A new calibration procedure is also developed to increase the precision of the measurements.

47 OTHER INSTRUMENTATION↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

X-ray-imaging spectrometer (XRIS) for studies of residual kinetic energy and low-mode asymmetries in inertial confinement fusion implosions at OMEGA (invited)

A system of x-ray imaging spectrometer (XRIS) has been implemented at the OMEGA Laser Facility and is capable of spatially and spectrally resolving x-ray self-emission from 5 to 40 keV. The system consists of three independent imagers with nearly orthogonal lines of sight for 3D reconstructions of the x-ray emission region. The distinct advantage of the XRIS system is its large dynamic range, which is enabled by the use of tantalum apertures with radii ranging from 50 μm to 1 mm, magnifications of 4 to 35×, and image plates with any filtration level. In addition, XRIS is capable of recording 1–100’s images along a single line of sight, facilitating advanced statistical inference on the detailed structure of the x-ray emitting regions. Properties such as P0 and P2 of an implosion are measured to 1% and 10% precision, respectively. Furthermore, T e can be determined with 5% accuracy.

Adrian, P. J.↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗