Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopy, Fourier Transform Infrared”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Polarized Light Microscopy

Polarized light microscopy (PLM) is a technique which employs the use of polarizing filters to obtain substantial optical property information about the material which is being observed. This information can be combined with other microscopy techniques to confirm or elucidate the identity of an unknown material, determine whether a particular contaminant is present (as with asbestos analysis), or to provide important information that can be used to refine a manufacturing or chemical process. PLM was the major microscopy technique in use for identification of materials for nearly a century since its introduction in 1834 by William Fox Talbot, as other techniques such as SEM (Scanning Electron Microscopy), FTIR (Fourier Transform Infrared spectroscopy), XPD (X-ray Powder Diffraction), and TEM (Transmission Electron Microscopy) had not yet been developed. Today, it is still the only technique approved by the Environmental Protection Agency (EPA) for asbestos analysis, and is often the technique first applied for identification of unknown materials. PLM uses different configurations in order to determine different material properties. With each configuration additional clues can be gathered, leading to a conclusion of material identity. With no polarizing filter, the microscope can be used just as a stereo optical microscope, and view qualities such as morphology, size, and number of phases. With a single polarizing filter (single polars), additional properties can be established, such as pleochroism, individual refractive indices, and dispersion staining. With two polarizing filters (crossed polars), even more can be deduced: isotropy vs. anisotropy, extinction angle, birefringence/degree of birefringence, sign of elongation, and anomalous polarization colors, among others. With the use of PLM many of these properties can be determined in a matter of seconds, even for those who are not highly trained. McCrone, a leader in the field of polarized light microscopy, often advised, If you cant determine a specific optical property of a particle after two minutes, move onto another configuration. Since optical properties can be seen so very quickly and easily under polarized light, it is only necessary to spend a maximum of two minutes on a technique to determine a particular property, though often only a few seconds are required.

Engineering↗

Boron Nitride Nanoribbons from Exfoliation of Boron Nitride Nanotubes

Two types of boron nitride nanotubes (BNNTs) were exfoliated into boron nitride nanoribbons (BNNR), which were identified using transmission electron microscopy: (1) commercial BNNTs with thin tube walls and small diameters. Tube unzipping was indicated by a large decrease of the sample's surface area and volume for pores less than 2 nm in diameter. (2) BNNTs with large diameters and thick walls synthesized at NASA Glenn Research Center. Here, tube unraveling was indicated by a large increase in external surface area and pore volume. For both, the exfoliation process was similar to the previous reported method to exfoliate commercial hexagonal boron nitride (hBN): Mixtures of BNNT, FeCl3, and NaF (or KF) were sequentially treated in 250 to 350 C nitrogen for intercalation, 500 to 750 C air for exfoliation, and finally HCl for purification. Property changes of the nanosized boron nitride throughout this process were also similar to the previously observed changes of commercial hBN during the exfoliation process: Both crystal structure (x-ray diffraction data) and chemical properties (Fourier-transform infrared spectroscopy data) of the original reactant changed after intercalation and exfoliation, but most (not all) of these changes revert back to those of the reactant once the final, purified products are obtained.

boron nitride nanotube↗

Air Contamination Quantification by FTIR with Gas Cell

Air quality is of utmost importance in environmental studies and has many industrial applications such as aviators grade breathing oxygen (ABO) for pilots and breathing air for fire fighters. Contamination is a major concern for these industries as identified in MIL-PRF-27210, CGA G-4.3, CGA G-7.1, and NFPA 1989. Fourier Transform Infrared Spectroscopy (FTIR) is a powerful tool that when combined with a gas cell has tremendous potential for gas contamination analysis. Current procedures focus mostly on GC-MS for contamination quantification. Introduction of this topic will be done through a comparison of the currently used deterministic methods for gas contamination with those of FTIR gas analysis. Certification of the mentioned standards through the ISOIEC 17065 certifying body A2LA will be addressed followed by an evaluation of quality information such as the determinations of linearity and the limits of detection and quantitation. Major interferences and issues arising from the use of the FTIR for accredited work with ABO and breathing air will be covered.

Freischlag, Jason↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Microgravity Experiments of Solid Waste Conversion into Useful Commodities

This Summer I participated in two projects at Kennedy Space Center in Cape Canaveral, Florida. The projects focus on the NASA's Deep Space Gateway applications for future Mars travel. All of these projects use recycling technology to use resources found on Earth and on other planets for fuel and other environmental applications. The first project I took the lead on is “Plasma Arc Gasification.” Plasma is a high temperature and very efficient way to process waste to create usable byproducts. The plasma chamber in temperature is comparable to that of the sun and this energy will help create an environment in which the waste can be recycled properly for not only plant support, but also for possible fuel application as well. I preformed the tests in a quartz tube, which is used to hold the waste (cotton, plastics, nylon, paper and a human waste simulant) and the waste is then combusted using O2 (present in air) into gases such as H2, H2O, CH4 and CO2. I determined which gases are present using a Fourier-transform infrared spectroscopy (FTIR) machine, which analyzes the peaks of the gases using liquid nitrogen. Problems arose in the beginning from the reactor emitting electromagnetic waves (EMI) that interfered with the technology of the experiment, specifically the thermocouples. This was solved through multiple tests with the positioning of the thermocouple power supply further away from the plasma reactor. I worked with another intern, Daniel Santander, who developed a space plant chamber which uses CO2 and H2O (harvested from the plasma reactor) to grow plants in space. The chamber possess a CO2 monitor, which controls the amount of gas that enters the chamber, along with a water integration system to supply the amount of water needed for proper plan growth. This technology will then be used for plant growth in space for the Astronauts on future space flights and possibly on the International Space Station (ISS). The second project I worked on is the “Orbital Syngas / Commodity Augmentation Reactor (OSCAR)” which focuses on the issues experienced in long-duration space flight regarding waste disposal. In previous space flight missions, waste was stored on board and returned to Earth for disposal. This technique is not applicable to long space flight missions to Mars due to the rocket being months away from Earth. OSCAR is using microgravity waste disposal techniques to produce fuels from the recycled waste. The waste is converted to syngas through a thermal degradation process. This process helps create an environmentally friendly way to dispose and reuse trash on board the space craft. Currently waste is being tested in the form of cotton and plastics. OSCAR is designed as a microgravity reactor that is currently being tested in a drop tower rig at Glenn Research Center. I helped design the 3D model for the insulation that will line the reactor. The first few trials, I dissolved the plastic of the mold in acetone. This method worked, but was very costly. I then received a silicone material to construct the mold from Swamp Works here at Kennedy. Through multiple trials with the silicone, this method worked best for developing the end pieces of the insulation for the chamber.

Plasma↗

Robust Bonding Through Process Control

Process control has been proven to be the most reliable means of safeguarding the quality of adhesive bonds according to Federal Aviation Administration (FAA). A method for implementing process control for reduction in risk in a bonded joint fabrication process is demonstrated in this study using a selected bonding system. The stepwise method included risk analysis to identify defects with the highest impact and likelihood to occur, evaluation of various pre-bond surface analysis tools to monitor for the selected defects, and demonstration of the benefits of in-process monitoring utilizing threshold limits determined from bond performance tests. The bonded system selected for investigation was an aerospace carbon fiber epoxy composite substrate surface prepared with random orbital sanding using 180 grit aluminum oxide sand paper. A series of portable, pre-bond surface analysis tools were investigated for their ability to be used for in-line bond process control. Results and threshold limits are presented from roughness, ballistic water contact angle (WCA), color, gloss, and Fourier transform infrared spectroscopy (FTIR) surface analysis tools. Results demonstrated how in-process inspection methods can be used to ensure quality of a surface preparation for a selected bonding system. A framework is provided for implementation of bond process control for robust bonding.

Kutscha, Eileen O.↗

Quantifying the Influence of Redox Conditions on the Seismic Properties of Olivine

A series of eight olivine specimens were fabricated by hot-pressing at 1200 degrees Celsius and 300 megapascals (MPa). Each hot-pressed specimen was then wrapped in Pt, Ni or NiFe foil to vary oxygen fugacity (fO2), and interrogated via forced torsional oscillation. Mechanical testing was conducted at 10 oscillation periods between 1 and 1000 seconds, at a confining pressure of 200 MPa, during a slow staged-cooling from a maximum temperature of 1200 degrees Celsius to room temperature. After mechanical testing, each specimen was axially sectioned and EBSD (Electron BackScatter Diffraction) was used for the determination of the representative grain size, and grain size distribution of each sample. In addition, each longitudinal section was mapped via FTIR (Fourier Transform InfraRed spectroscopy) to determine the spatial distribution and concentrations of chemically bound and molecular water. Amongst these specimens, chemically bound ‘water’ contents were observed to vary between 0 and 1150 atom ppm (parts per million) H/Si, and molecular water concentrations varied between 0 and 245 atom ppm H/Si. Our forced-oscillation results demonstrate that the measured magnitude of anelastic relaxation within the experimental ‘window’ of oscillation periods is unrelated to the water content. Rather, a relationship was observed between the magnitude of anelastic relaxation and the prevailing redox conditions, which is influenced by the choice of metal sleeving used during the mechanical test. Further, regardless of water content or metal sleeving, each specimen exhibits coupled variations in shear modulus and dissipation within the observational window, indicative of ‘high-temperature background’ behavior, that can be described by a Burgers-type model. During initial fitting of the Burgers models, the unrelaxed shear modulus at a reference temperature of 900 degrees Celsius (G (sub UR)) and the temperature derivative of the unrelaxed shear modulus (dG (sub U)/dT), were treated as adjustable parameters. For all Fe-bearing olivine samples (but not a hydrous and oxidized Fe-free sample) we observe deficits of G (sub UR), and increased values of dG (sub U)/dT, relative to the expected elastic (anharmonic) behavior of Fo90 olivine. This behavior is indicative of anelastic relaxation occurring at shorter periods than observable within the ‘window’ of oscillation periods used in the mechanical test. Moving towards a comprehensive seismologically applicable Burgers model, which includes this newly observed effect of redox conditions on anelastic relaxation, we will present our progress in reconciling truly anharmonic and elastic behavior of Fo (sub 90) olivine with our observed forced-oscillation data.

Cline, Christopher, II↗

The Influence of Redox Conditions on the Seismic Properties of Polycrystalline Olivine

Eight olivine specimens were fabricated by use of a solgel method and hot-pressing at 1200 degrees Centigrade and 300 megapascals (MPa) inside of welded Pt capsules. Each hot-pressed specimen was then recovered, precision ground, and wrapped in Pt, Ni or NiFe foil to vary oxygen fugacity (fO2) during the subsequent forced torsional oscillation measurements. Mechanical testing was conducted at 10 oscillation periods between 1 and 1000 seconds, at a confining pressure of 200 MPa, during a slow staged-cooling from a maximum temperature of 1200 degrees Centigrade down to room temperature. After mechanical testing, each specimen was axially sectioned and EBSD (Electron BackScatter Diffraction) was used for the determination of the representative grain size, and grain size distribution of each sample. In addition, each longitudinal section was mapped via FTIR (Fourier Transform Infrared Spectroscopy) to determine the spatial distribution and concentrations of chemically bound and molecular water. Amongst these eight specimens, chemically bound ‘water’ contents were observed to vary between 0 and 1150 atom parts per million (ppm) H/Si, and molecular water concentrations varied between 0 and 245 atom ppm H/Si. Our forced-oscillation results demonstrate that the measured magnitude of anelastic relaxation within the experimental ‘window’ of oscillation periods is unrelated to the water content. Rather, a relationship was observed between the magnitude of anelastic relaxation and the prevailing redox conditions, which is influenced by the choice of metal sleeving used during the mechanical test. Further, regardless of water content or metal sleeving, each specimen exhibits coupled variations in shear modulus and dissipation within the observational window, indicative of ‘high-temperature background’ behavior, that can be described by a Burgers-type model. During initial fitting of the Burgers models, the unrelaxed shear modulus at a reference temperature of 900°C (elastic unloading/reloading shear modulus G (sub UR)) and the temperature derivative of the unrelaxed shear modulus (dGU/dT), were treated as adjustable parameters. For all Fe-bearing olivine samples we observe deficits of G (sub UR) and increased values of dGU/dT, relative to the expected elastic (anharmonic) behavior for Fo (Forsterite content percentage) (sub 90) olivine. This behavior is indicative of anelastic relaxation occurring at shorter periods than observable within the ‘window’ of oscillation periods used in the mechanical test. Moving towards a comprehensive and seismologically applicable Burgers model, which includes this newly observed effect of redox conditions on anelastic relaxation, we will present our progress on reconciling truly anharmonic and elastic behavior of Fo (sub 90) olivine with our observed forced-oscillation data.

Cline, C. J., II↗

Characterization of Thermal Protection Systems: An Analysis of Optical & Thermal Properties

Thermal Protection System Materials & thermal control coatings were characterized by a variety of methodologies including heat flow meter method (HFM), dynamic scanning calorimetry (DSC), fourier transform infrared spectroscopy (FTIR), and Ultra-Violet & Visible light spectroscopy (UV-VIS). Physical properties were measured to aid in the construction of thermal response models for a number a projects including MEDLI and MEDLI2. Comparing pre-flight predictions with actual flight data can allow for a reduction of margins and improve designs. The models enable design of TPS for flight missions and analysis of flight data to understand aerothermal environments experienced on the mission. This presentation reveals critical information: heat capacity (cp vs T), thermal conductivity ( vs T), and emissivity (E vs T) for Super Lightweight Ablative (SLA), Phenolic Impregnated Carbon Ablative (PICA-D), & Heatshield for Extreme Entry Environment Technology (HEEET). These properties were also measured for various thermal control coatings manufactured by AZ Technology. A portion of this work is incomplete and highlights questions to investigate in the future.

Cole, Brian↗

Ammonia Stability in a Simulated Trace Contaminant Rich Cabin Environment

The off-gassing of ammonia from hardware and metabolic sources presents a unique challenge to trace contaminant control system design, driving process flowrates to meet crewed air quality requirements. Accurately simulating representative trace contaminant cabin loads during ground testing is necessary to validate component design as well as understand potential contaminant propagation across life-support system process interface boundaries. This effort is complicated by the observed temporal concentration instability of gaseous ammonia in ground test chambers. To this end, ammonia concentration decay rates were characterized under controlled environmental conditions to better understand underlying phenomena and quantify incidental mass losses. The suspected chemical interaction between ammonia and trace acetaldehyde was investigated and its effect on species quantification was examined by both gas chromatography-mass spectrometry and Fourier-transform infrared spectroscopy. Recommendations for ground test procedures were made in order to best compensate for undesirable ammonia mass losses and mitigate test artifacts.

Kayatin, Matthew J.↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Optically Enhanced Bonding Workstation for Robust Bonding

Process control is one of the methods recommended by the FAA to reduce risk in fabrication of structurally bonded composite joints for aircraft structure based on guidance provided in circular AC-107B for certification of structurally bonded joints. An Optically Enhanced Bonding Workstation is presented here that reduces the risk in bonded joint fabrication. Results will be presented demonstrating the benefits of process monitoring and its ability to reduce risk in performing pre-bond composite surface preparation steps. This supports reduction in the timeline to certification of bonded composite structures through development of a robust bonding process upstream of any part certification steps. Sanding surface preparation has been identified as a high risk process step that is known to impact bond performance. Control of sanding during surface preparation can be performed using portable surface analysis tools previously identified including included gloss, color, Fourier Transform Infrared spectroscopy (FTIR) and optically stimulated electron emissions (OSEE). Threshold limits for the surface analysis tool measurements were determined based on an example objective bonding system utilizing a common EA9394 paste adhesive measured using standard double cantilever beam fracture toughness testing. The patented Optically Enhanced Bonding Workstation (OEBW), was tailored to monitor and control the epoxy composite surface preparation step. Surface analysis tool threshold limits were incorporated into the OEBW to demonstrate improved composite bond performance through process control. The surface analysis tools investigated here can easily be incorporated into an automated system due to their applicability to rapidly quantify the composite sanded surface treatment and their portability.

Kutscha, Eileen O.↗

Effectiveness of Surface Treatment Techniques for Composite Bonding with Different Contamination Levels

Various surface treatment techniques have been developed to promote adhesive bond performance for composite structural components in aerospace applications. The condition of the pre-bond surface is critical to achieving desirable bond quality. Contamination on bonding surfaces is well recognized as a major threat to ultimate bond performance. Variation in contamination level has brought additional challenges into manufacturing process control. High fidelity surface treatment techniques are required for effective removal of contaminants over a wide range of contamination levels. In this study, a common contaminant, i.e. silicone mold release, was introduced to pre-bond composite surfaces with different concentrations. Plasma and laser surface treatment techniques were performed and their effectiveness in restoring and enhancing desirable bond quality was investigated. Surface characterization techniques, including water contact angle goniometry, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy, were conducted to assess the condition of contaminated surfaces and the improvement induced by plasma and laser surface treatments. Failure modes from a customized double cantilever beam test were investigated before and after surface treatments. Fundamental mechanisms of plasma and laser surface treatments on the composite bonding surfaces were also investigated.

Fang, Xiaomei↗

TPSAS-NF1676L-34417-DND

A boron nitride nanotube (BNNT), an electrically-insulating counterpart of a carbon nanotube (CNT), is a great nanofiller candidate for ferroelectric polymeric nanocomposites due to BNNT?s exceptional properties in piezoelectricity, thermal stability, mechanical strength, and radiation shielding capability. Fast and high-yield polar crystallization of polyvinylidene fluoride (PVDF) was accomplished by incorporating BNNTs as a nucleating agent. As-fabricated BNNT-PVDF nanocomposites were characterized by Fourier-transform infrared spectroscopy (FTIR), wide-angle X-ray diffraction (XRD), and differential scanning calorimetry (DSC) to identify and quantify chain conformations. Besides, piezoelectric constants, d33 of BNNT-PVDF nanocomposites were measured and compared with that of a mechanically drawn beta phase polar PVDF. The polar transformation due to BNNT incorporation has a great advantage over conventional beta or gamma transformation methods that require (1) mechanical drawing often resulting in defects or (2) high-temperature annealing for an extended time. In addition to the fast polar crystallization, BNNTs had a role of reinforcement of the polymer matrix. The improved Young?s modulus and electromechanical coupling coefficient of BNNT-PVDF nanocomposites indicated potential applications in energy harvesting under harsh environments such as large deformation, wide temperature cycles, and high radiation.

Dongwon Lee↗

Polycyclic Aromatic Hydrocarbons and Dust Particle Surface Interactions: Catalytic Hydrogenation of Polycyclic Aromatic Hydrocarbon Molecules under Vacuum Conditions

This work reports experiments on the catalytic interaction occurring between polycyclic aromatic hydrocarbon (PAH) molecules and TiO2 dust grain surfaces under vacuum conditions. The investigation sheds light on the potential catalytic pathways that TiO2 dust surfaces provide in the hydrogenation of PAH molecules and the chemistry that can be driven by PAH-dust interactions under vacuum conditions. Naphthalene, anthracene, and coronene were chosen as the PAH molecules, while titanium dioxide was selected as the dust analog. PAH samples and dust analog mixtures were studied under vacuum for 24 h while monitored via diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). The acquired spectra show that PAH molecules are hydrogenated when in contact with TiO2 dust particles without the need for external energy or hydrogen sources. Our results suggest that linear PAHs undergo a similar hydrogenation process where the dominant species are fully hydrogenated PAHs. For larger condensed PAHs, the hydrogenation process yields partially hydrogenated molecules. Fully hydrogenated species can be identified by a band around 2960 per cm, while partially hydrogenated species produce a band around 2825 per cm. In the case of the production of hydrogenated species, our results suggest that the smaller the PAH, the faster the hydrogenation rate.

polycyclic aromatic hydrocarbons↗

Preliminary Examination of Returned Samples From Bennu Using Quantitative Particle Analysis in the Scanning Electron Microscope

The sample of regolith collected from asteroid Bennu by NASA’s OSIRIS-REx spacecraft will land in Utah on September 24, 2023. A 100-mg aliquot of fine Bennu dust adhering to the internal surfaces of the sample return capsule and associated hardware will be collected by curation staff during disassembly and analyzed immediately by members of the sample analysis team in a “Quick-Look” (Q-L) procedure. The Q-L objectives are (1) to provide images for release to the public to inform on the nature of the returned sample, and (2) to perform a reconnaissance investigation of the mineralogic characteristics of the returned material for science purposes. We will determine the minerals that occur in the dust, assess their diversity, and determine relative abundances at the >5% level using a combination of optical microscopy, Fourier-transform infrared spectroscopy, X-ray powder diffraction, and field-emission scanning electron microscopy (SEM). Here we describe the procedures and techniques developed for the Q-L analyses using analog samples analyzed by SEM equipped with energy dispersive X-ray spectroscopy (EDX). To test these techniques, we have applied them to several samples, including powders of the Murchison (Fig. 1) and Orgueil meteorites, as well as simulant samples prepared by the mission.

OSIRIS-REx↗

Increasing Flexibility of Polymers in the Application of Complex Space Craft Heat Shield Geometries

Highly crosslinked polymers, commonly utilized in spacecraft component fabrication, especially for heatshields, have historically encountered challenges due to their inherent brittleness. To overcome this issue, researchers have explored the incorporation of additives into the polymer backbone to enhance flexibility and durability. This study aims to improve the flexibility and durability of highly crosslinked polymers by introducing long-chain aliphatic silicon-based additives with varying molecular weights into the polymer backbone. By increasing the flexibility of these brittle polymers, they can be effectively employed in constructing intricate curvatures for heatshields, eliminating the need for gap fillers. In this study, we investigated six different additives, comparing them to a highly crosslinked high-temperature polymer used as a baseline. Various characterization techniques, including thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), dilatometry, dynamic mechanical analysis (DMA), nuclear magnetic resonance (NMR), and Fourier transform infrared spectroscopy (FTIR), were employed to assess the properties of the materials. The FTIR and NMR results indicated the successful incorporation of the silicon-based additives into the polymer backbone. Furthermore, thermal characterization results demonstrated that certain additives exhibited superior flexibility and lower densities compared to the baseline polymer.

Tane Boghozian↗