Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopy experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Website for the Astrochemistry Laboratory, Astrophysics Branch, Space Sciences Division

The Astrochemistry Laboratory in the Astrophysics Branch (SSA) of the Space Sciences Division at NASA's Ames Research Center specializes in the study of extraterrestrial materials and their analogs. The staff has pioneered laboratory studies of space environments including interstellar, cometary, and planetary ices, simulations of the so-called 'Unidentified' Infrared Emission Bands and Diffuse Interstellar Bands using PAHs (Polycyclic Aromatic Hydrocarbons) and PAH-related materials, and has extensive experience with low-temperature spectroscopy and astronomical observation. Important discoveries made by the Astrochemistry Group include: (1) The recognition that polycyclic aromatic hydrocarbons and their ions are common in space; (2) The identification of a major fraction of the known molecular species frozen in interstellar/pre-cometary ices; (3) The recognition that a significant fraction of the carbon in the interstellar medium is carried by both microdiamonds and organic materials; (4) The expansion of the types of molecules expected to be synthesized in interstellar/pre-cometary ices. These could be delivered to the early Earth (or other body) and influence the origin or early evolution of life.

Sandford, Scott↗

Lunar and Planetary Science XXXV: Undergraduate Education and Research Programs, Facilities, and Information Access

The titles in this section include: 1) GRIDVIEW: Recent Improvements in Research and Education Software for Exploring Mars Topography; 2) Software and Hardware Upgrades for the University of North Dakota Asteroid and Comet Internet Telescope (ACIT); 3) Web-based Program for Calculating Effects of an Earth Impact; 4) On-Line Education, Web- and Virtual-Classes in an Urban University: A Preliminary Overview; 5) Modelling Planetary Material's Structures: From Quasicrystalline Microstructure to Crystallographic Materials by Use of Mathematica; 6) How We Used NASA Lunar Set in Planetary and Material Science Studies: Textural and Cooling Sequences in Sections of Lava Column from a Thin and a Thick Lava-Flow, from the Moon and Mars with Terrestrial Analogue and Chondrule Textural Comparisons; 7) Classroom Teaching of Space Technology and Simulations by the Husar Rover Model; 8) New Experiments (In Meteorology, Aerosols, Soil Moisture and Ice) on the New Hunveyor Educational Planetary Landers of Universities and Colleges in Hungary; 9) Teaching Planetary GIS by Constructing Its Model for the Test Terrain of the Hunveyor and Husar; 10) Undergraduate Students: An Untapped Resource for Planetary Researchers; 11) Analog Sites in Field Work of Petrology: Rock Assembly Delivered to a Plain by Floods on Earth and Mars; 12) RELAB (Reflectance Experiment Laboratory): A NASA Multiuser Spectroscopy Facility; 13) Full Text Searching and Customization in the NASA ADS Abstract Service.

Source record↗

Electron Impact Excitation of Autoionizing Levels of Kr and Xe Between the (sup 2)P(sub 3/2) and (sup 2)P(sub 1/2) Ionic Limits

We have observed electrons ejected from autoionizing levels which lie between the (sup 2)P(sub 3/2) and (sup 2)P(sub 1/2) ionic limits for Kr and Xe. Kinetic energy spectra of the ejected electrons were obtained following electron impact excitation of the target gases by using time-of-flight spectroscopy in a crossed beam experiment. Spectral features which correspond to electrons ejected from both odd and even parity autoionizing levels have been identified.

autoionizing ejected electrons↗

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Using Simulated Micrometeoroid Impacts to Understand the Progressive Space Weathering of the Surface of Mercury

The surfaces of airless bodies such as Mercury are continually modified by space weathering, which is driven by micrometeoroid impacts and solar wind irradiation. Space weathering alters the chemical composition, microstructure, and spectral properties of surface regolith. In lunar and ordinarychondritic style space weathering, these processes affect the reflectance properties by darkening (lowering of reflectance), reddening (increasing reflectance with increasing wavelength), and attenuation of characteristic absorption features. These optical changes are driven by the production of nanophase Febearing particles (npFe). While our understanding of these alteration processes has largely been based on data from the Moon and near-Earth S-type asteroids, the space weathering environment at Mercury is much more extreme. The surface of Mercury experiences a more intense solar wind flux and higher velocity micrometeoroid impacts than its planetary counterparts at 1 AU. Additionally, the composition of Mercury’s surface varies significantly from that of the Moon. Most notably, a very low albedo unit has been identified on Mercury’s surface, known as the low reflectance material (LRM). This unit is enriched with up to 4 wt.% carbon, likely in the form of graphite, over the local mean. In addition, the surface concentration of Fe across Mercury’s surface is low (<2 wt.%) compared to the Moon. Our understanding of how these low-Fe and carbon phases are altered as a result of space weathering processes is limited. Since Fe plays a critical role in the development of space weathering features on other airless surfaces (e.g., npFe), its limited availability on Mercury may strongly affect the space weathering features in surface materials. In order to understand how space weathering affects the chemical, microstructural, and optical properties of the surface of Mercury, we can simulate these processes in the laboratory [7]. Here we used pulsed laser irradiation to simulate the short duration, high temperature events associated with micrometeoroid impacts. We used forsteritic olivine, likely present on the Mercurian surface, with varying FeO contents, each mixed with graphite, in our experiments. We then performed reflectance spectroscopy and electron microscopy to investigate the spectral, chemical, and microstructural changes in these samples.

Thompson, Michelle S.↗

N2/O2/H2 Dual-Pump Cars: Validation Experiments

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.

OByrne, S.↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out an intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R = 512 and employing kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through measurement of atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R=512 and employing microwave kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through measurement of atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R=512 and employing microwave kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

Observations of the X-ray Nova GRO J0422+32. 1: Outburst and the decay to quiescence

We present optical photometry and spectroscopy and Burst and Transient Source Experiment (BATSE) observations of the X-ray nova GRO J0422+32, obtained during outburst and its subsequent decay to quiescence. Although the X-ray and optical properties of GRO J0422+32 are broadly similar to those of other X-ray novae, it is unique in several respects. The unusually protracted decay to quiescence of the optical light curve has been punctuated by at least two minioutbursts of approximately 4 mag. The BATSE and optical outbursts are each separated by approximately 120 days. We find that the optical luminosity of GRO J0422+32 during the primary outburst is dominated by reprocessing of E greater than 10 keV X-rays. In contrast, the optical minioutbursts are most likely generated by an intrinsically bright disk rather than X-ray reprocessing: they do not appear to have any X-ray counterparts. Extremely broad (up to 6000 km/s FWZI) absorption lines have also been observed during both primary outbursts and minioutbursts. During the second minioutburst, H-alpha and H-beta emission was observed superposed on redshifted absorption features. We find that the interoutburst light curve of GRO J0422+32 may be inconsistent with an accretion disk instability as the origin of the minioutbursts. Finally, a transient 5.1/10.2 hr modulation, which may be related to the orbital period, has been observed during roughly half of our observations. However, confirmation of the orbital period must await observations in quiescence.

Callanan, Paul J.↗

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound↗

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound↗

Broad band X-ray astronomical spectroscopy

The Broad Band X-Ray Telescope (BBXRT) experiment has been designed for high sensitivity, moderate resolution spectrophotometry of cosmic sources in the range 0.5 to 12 keV. Principal elements are two co-aligned imaging telescopes with cooled Si(Li) detectors at each focus. The mirror design uses an approximate geometry of tightly nested, conical, foil reflectors that allow a large filling factor (high throughput) at small grazing angles (high energy response). Each detector consists of a cluster of five elements defined with grooves on a single crystal. This arrangement affords some spatial resolution as well as a means of substantial background reduction. Shuttle borne measurements will typically be of 2000 s duration for sources with a flux of 10 to the -12 erg/sq cm-s.

Serlemitsos, P. J.↗

The LAMAR telescope module for high throughput imaging and spectroscopy

Kirkpatrick-Baez mirror assemblies for the LAMAR experiment of the Space Shuttle are described. The aperture is 20 cm x 30 cm and the distance from the front of the mirror to the focal plane is 3.4 m. The reflectors are made from 1.8 mm gold coated float glass. A prototype brassboard mirror was constructed with only one-third of the plates. Its angular resolution is 35 arcsec (HPW) in visible light. X-ray tests over small areas indicate very little scattering. The fabrication technique is applicable to larger mirror systems such as those of XMM. The use of flatter material for the reflectors results in better angular resolution.

Gorenstein, P.↗