Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

magnetoARPES: Angle Resolved Photoemission Spectroscopy with magnetic field control

Angle-Resolved Photoemission Spectroscopy (ARPES) is a premier technique for understanding the electronic excitations in conductive, crystalline matter, in which the induced photocurrent is collected and dispersed in energy and angle of emission to reveal the energy- and momentum-dependent single particle spectral function A (k,ω). So far, ARPES in a magnetic field has been precluded due to the need to preserve the electron paths between the sample and detector. Here, in this paper we report progress towards “magnetoARPES”, a variant of ARPES that can be conducted in a magnetic field. It is achieved by applying a microscopic probe beam (≲10 μm) to a thinned sample mounted upon a special sample holder that generates magnetic field confined to a thin layer near the sample surface. In this geometry we could produce ARPES in magnetic fields up to around ±100 mT. The magnetic fields can be varied from purely in-plane to nearly purely out-of-plane, by scanning the probe beam across different parts of the device. We present experimental and simulated data for graphene to explore the aberrations induced by the magnetic field. These results demonstrate the viability of the magnetoARPES technique for exploring symmetry breaking effects in weak magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strategies for preparing and analyzing thin passive films with atom probe tomography

Atom probe tomography provides a unique, three-dimensional map of elemental and isotopic distributions over a wide range of materials with near-atomic scale resolution and is particularly strong at analyzing buried interfaces within materials. However, it is much more difficult to apply atom probe to the analysis of nanoscale surface films, such as those formed during alloy passivation, where unique challenges persist for sample preparation and data collection. Here, we present sample preparation strategies involving the deposition of a < 100 nm capping layer that enables reliable characterization of thin passive films approximately 2–5 nm thick formed on binary and multi-principal element alloys via atom probe tomography. Several capping layer materials (Pt, Ti, Ni/Cr bi-layer) and deposition methods are contrasted. Our results indicate a sputtered Ni/Cr bi-layer enables the characterization of the entire passive film and concentration profiles that can easily be interpreted to clearly distinguish base alloy/passive film/capping layer interfaces. Lastly, we highlight ongoing challenges and opportunities for this experimental approach.

Kautz, Elizabeth J. [University of Florida]↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Saltstone Oxidation Study: Leaching Method

Cementitious waste forms can be designed to chemically stabilize selected contaminants, such as Tc{sup +7} and Cr{sup +6}, by chemically reduction to lower valance states, Tc{sup +4} and Cr{sup +3}, respectively, and precipitation of these species in alkaline media as low solubility solid phases. Data for oxidation of this type of cementitious waste form cured under field conditions as a function of time is required for predicting the performance of the waste form and disposal facility. The rate of oxidation (oxidation front advancement) is an important parameter for predicting performance because the solubilities of some radionuclide contaminants, e.g., technetium, are a function of the oxidation state. A non-radioactive experiment was designed for quantifying the oxidation front advancement using chromium, as an approximate redox-sensitive surrogate (Cr{sup +6} / Cr{sup +3}) for technetium (Tc{sup +7} / Tc{sup +4}). Nonradioactive cementitious waste forms were prepared in the laboratory and cured under both laboratory and ?field conditions.? Laboratory conditions were ambient temperature and sealed sample containers. Field conditions were approximated by curing samples in open containers which were placed inside a plastic container stored outdoors at SRS. The container had a lid and was instrumented with temperature and humidity probes. Subsamples as thin as 0.2 mm were taken as a function of distance from the exposed surface of the as-cast sample. The subsamples were leached and the leachates were analyzed for chromium, nitrate, nitrite and sodium. Nitrate, nitrite, and sodium concentrations were used to provide baseline data because these species are not chemically retained in the waste form matrix to any significant extent and are not redox sensitive. ?Effective? oxidation fronts for Cr were measured for samples containing 1000, 500 and 20 mg/kg Cr added as soluble sodium chromate, Na{sub 2}CrO{sub 4}. For a sample cured for 129 days under field conditions, leachable Cr (assumed to be the oxidized form, i.e., Cr{sup +6} was detected in the top 15 to 20 mm of the sample spiked with 1000 mg/kg Cr. Below about 20 mm, the Cr concentrations in leachates were below the detection limit (< 0.010 mg/L) which indicates that the oxidation as the result of exposure to air was limited to the top 20 mm of the sample after exposure for 129 days and that the bulk of the waste form was not affected, i.e., the Cr was stabilized and insoluble. For samples cured in the laboratory, leachable Cr was detected in the top 8 mm of the Cr 1000 sample cured in the laboratory for 37 days. Between 8 and 14 mm, the concentration Cr in the leachate dropped by a factor of about 20 to just above the detection limit. These depth of penetration results indicate that the rate of advancement of the oxidation front for samples spiked with 1000 mg/kg Cr cured under ?field conditions? for 129 days is less than that for the sample cured in the laboratory for 37 days, i.e., 0.156 and 0.216 mm/day, respectively. Additional data are presented for samples spiked with 500 and 20 mg/kg Cr. In summary, cementitious waste forms are porous solids with a network of interconnected pores ranging in diameter from 10E-10 m to greater than a few mm. The oxidation process is assumed to occur as the result of oxygen transport through the interconnected porosity which may be filled with air, aqueous salt solution, or both. Upon oxidation, the Cr becomes soluble and can be transported in solution through aqueous pore fluid or leachate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pump-probe X-ray Diffraction Technique for Irreversible Phase Change Materials

We have developed a pump-probe X-ray diffraction measurement system for a sample with irreversible reaction at BL40XU in the SPring-8. The system mainly consists of a time-resolved measurement system, a sample disk rotation system, and an X-ray microbeam system. The time-resolved measurement system gives time resolution of 50 ps in laser-pump and X-ray probe method. A sample disk rotation system for repetitive measurements was made to give a virgin sample for every measurement. The number of repetitions for one sample disk was increased by using the X-ray microbeam technique. To keep the overlap of the X-ray microbeam and the laser beam on the sample surface during the disk rotation, the sample disk rotation system was constructed by a low-eccentric spindle motor. By using this system, the pump-probe X-ray diffraction measurement was demonstrated for a crystallization process of a DVD material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity enhancement of surface thermal lens technique with a short-wavelength probe beam: Experiment

Surface thermal lens is a highly sensitive photothermal technique to measure low absorption losses of various solid materials. In such applications, the sensitivity of surface thermal lens is a key parameter for measuring extremely low absorption. In this paper, we experimentally investigated the influence of probe beam wavelength on the sensitivity of surface thermal lens for measuring the low absorptance of optical laser components. Three probe lasers with wavelength 375 nm, 633 nm, and 1570 nm were used, respectively, to detect the surface thermal lens amplitude of a highly reflective coating sample excited by a cw modulated Gaussian beam at 1064 nm. The experimental results showed that the maximum amplitude of surface thermal lens signal obtained at corresponding optimized detection distance was inversely proportional to the wavelength of the probe beam, as predicted by previous theoretical model. The sensitivity of surface thermal lens could, therefore, be improved by detecting surface thermal lens signal with a short-wavelength probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction Between Liquid Silver and Graphene-Coated SiC Substrate

Wettability between liquid Ag and graphene-coated SiC single crystal has been investigated by dispensed drop method at T = 970 °C under vacuum accompanied with subsecond recording of the drop/substrate images (100 frames per second) by high-speed high-resolution CCD camera. Non-contact heating method coupled with capillary purification of the Ag drop procedure has been applied. Scanning electron microscopy combined with EDS analysis and scanning probe microscopy combined with Raman spectroscopy techniques has been utilized for microstructure and surface characterization of samples before and after high-temperature wetting tests. Immediately after its detachment from the capillary, the Ag drop showed non-wetting behavior (θ > 90°) forming a high contact angle of θ = 114°. Surface characterization of the drop surface after wettability tests evidenced the presence of graphene and Si transferred from the substrate to the top of Ag drop. These findings suggest chemical interaction phenomena occurring at the interface. Locally, an intimate contact between liquid Ag and SiC substrate was allowed by the appearance of discontinuities in the graphene layer basically produced by thermomechanical stress. Local dissolution of carbon into liquid Ag and its reorganization (by segregation, nucleation and growth) as secondary graphene layer at the Ag surface was also observed.

36 MATERIALS SCIENCE↗

Spatially correlated incommensurate lattice modulations in an atomically thin high-temperature Bi 2.1 Sr 1.9 CaCu 2.0 O 8+y superconductor

Strong variations in superconducting critical temperatures in different families of the cuprate perovskites, even with similar hole doping in their copper-oxygen planes, suggest the importance of lattice modulation effects. The one-dimensional incommensurate lattice modulation (ILM) of Bi 2 Sr 2 CaCu 2 O 8+y , with the average atomic positions perturbed beyond the unit cell6, offer s an ideal test ground for studying the interplay between superconductivity and the long-range incommensurate lattice fluctuations. Here we report Scanning nano X-ray Diffraction (SnXRD) imaging of incommensurate lattice modulations in Bi 2 Sr 2 CaCu 2 O 8+y Van der Waals heterostructures of thicknesses down to two-unit cells. Using SnXRD, we probe that the long-range and short-range incommensurate lattice modulations in bulk sample surface with spatial resolution below 100 nm. We find that puddle-like domains of ILM of size uniformly evolving with dimensionality. In the 2-unit cell thin sample, it is observed that the wavevectors of the long- and short-range orders become anticorrelated with emerging spatial patterns having a directional gradient. The emerging patterns, originated by tiny tuning of lattice strain, induce static mesoscopic charge density waves. Finally, our findings thus demonstrate that the strain can be used to tune and control the electromagnetic properties of two-dimensional high-temperature superconductors.

36 MATERIALS SCIENCE↗

Probing three-dimensional surface force fields with atomic resolution: Measurement strategies, limitations, and artifact reduction

Noncontact atomic force microscopy (NC-AFM) is being increasingly used to measure the interaction force between an atomically sharp probe tip and surfaces of interest, as a function of the three spatial dimensions, with picometer and piconewton accuracy. Since the results of such measurements may be affected by piezo nonlinearities, thermal and electronic drift, tip asymmetries, and elastic deformation of the tip apex, these effects need to be considered during image interpretation. In this paper, we analyze their impact on the acquired data, compare different methods to record atomic-resolution surface force fields, and determine the approaches that suffer the least from the associated artifacts. The related discussion underscores the idea that since force fields recorded by using NC-AFM always reflect the properties of both the sample and the probe tip, efforts to reduce unwanted effects of the tip on recorded data are indispensable for the extraction of detailed information about the atomic-scale properties of the surface.

36 MATERIALS SCIENCE↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

SURFACE CHARACTERIZATION OF NIOBIUM SAMPLES ELECTRO-POLISHED TOGETHER WITH REAL CAVITIES

We report the results of surface characterizations of niobium samples electropolished together with single cell cavities. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive x-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulphur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulphur.

36 MATERIALS SCIENCE↗

Surface characterization of Nb samples electropolished together with real superconducting rf accelerator cavities

Here, we report the results of surface characterizations of niobium (Nb) samples electropolished together with a single cell superconducting radio-frequency accelerator cavity. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive X-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.

43 PARTICLE ACCELERATORS↗

Is light-induced degradation of a-Si:H/c-Si interfaces reversible?

Thin hydrogenated amorphous silicon (a-Si:H) films deposited on crystalline silicon (c-Si) surfaces are sensitive probes for the bulk electronic properties of a-Si:H. Here, we use such samples during repeated low-temperature annealing and visible-light soaking to investigate the long-term stability of a-Si:H films. We observe that during annealing the electronic improvement of the interfaces follows stretched exponentials as long as hydrogen evolution in the films can be detected. Once such evolution is no longer observed, the electronic improvement occurs much faster. Based on these findings, we discuss how the reversibility of light-induced defects depends on (the lack of observable) hydrogen evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FAINT TIDAL FEATURES IN GALAXIES WITHIN THE CANADA-FRANCE-HAWAII TELESCOPE LEGACY SURVEY WIDE FIELDS

We present an analysis of the detectability of faint tidal features in galaxies from the wide-field component of the Canada-France-Hawaii Telescope Legacy Survey. Our sample consists of 1781 luminous (M{sub r{sup '}}<-19.3 mag) galaxies in the magnitude range 15.5 mag < r' < 17 mag and in the redshift range 0.04 < z < 0.2. Although we have classified tidal features according to their morphology (e.g., streams, shells, and tails), we do not attempt to interpret them in terms of their physical origin (e.g., major versus minor merger debris). Instead, we provide a catalog that is intended to provide raw material for future investigations which will probe the nature of low surface brightness substructure around galaxies. We find that around 12% of the galaxies in our sample show clear tidal features at the highest confidence level. This fraction rises to about 18% if we include systems with convincing, albeit weaker tidal features, and to 26% if we include systems with more marginal features that may or may not be tidal in origin. These proportions are a strong function of rest-frame color and of stellar mass. Linear features, shells, and fans are much more likely to occur in massive galaxies with stellar masses >10{sup 10.5} M {sub Sun }, and red galaxies are twice as likely to show tidal features than are blue galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface characterization of niobium samples electropolished together with real cavities

We report the results of surface characterization of niobium samples electropolished together with single-cell niobium cavities. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe respectively. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive x-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.

Zhao, Xin↗

Josephson scanning tunneling microscopy -- a local and direct probe of the superconducting order parameter

Direct measurements of the superconducting superfluid on the surface of vacuum-cleaved Bi2Sr2CaCu2O8+delta (BSCCO) samples are reported. These measurements are accomplished via Josephson tunneling into the sample using a novel scanning tunneling microscope (STM) equipped with a superconducting tip. The spatial resolution of the STM of lateral distances less than the superconducting coherence length allows it to reveal local inhomogeneities in the pair wavefunction of the BSCCO. Instrument performance is demonstrated first with Josephson measurements of Pb films followed by the layered superconductor NbSe2. The relevant measurement parameter, the Josephson ICRN product, is discussed within the context of both BCS superconductors and the high transition temperature superconductors. The local relationship between the ICRN product and the quasiparticle density of states (DOS) gap are presented within the context of phase diagrams for BSCCO. Excessive current densities can be produced with these measurements and have been found to alter the local DOS in the BSCCO. Systematic studies of this effect were performed to determine the practical measurement limits for these experiments. Alternative methods for preparation of the BSCCO surface are also discussed.

36 MATERIALS SCIENCE↗

Scanning photoelectron microscopy using a pointed capillary probe

The possibilities of a new type of scanning probe microscopy (SPM) for two different samples are experimentally demonstrated. The method is based on the use of a pointed capillary, which can simultaneously act as a ‘classical’ SPM probe and also as a controlled thin channel for transporting charged particles emitted by the surface to the detector. In the experiment, photoelectrons pass through a dielectric hollow cone probe with an aperture radius of 1 μm and detected by microchannel plates at different points of the investigated conducting surface irradiated by the second harmonic of a femtosecond Ti : sapphire laser. As a result, the sample’s surface profile is visualised with a subwavelength spatial resolution. This method makes it possible to control spatially localised beams of electrons, ions, neutral atoms (molecules) and soft X-ray radiation, as well as opens a possibility for research in the field of nanoscale photodesorption of molecular ions. (electron microscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a surface conductivity measurement system for ultrahigh vacuum transmission electron microscope

The surface conductivity measurement system using a micro-four-point probe (M4PP) had been developed for the ultrahigh vacuum transmission electron microscope (UHV-TEM). Since the current distribution in the sample crystals during the current voltage measurement by the M4PP is localized within the depth of several micrometers from the surface, the system is sensitive to the surface conductivity, which is related with the surface superstructure. It was installed in the main chamber of the TEM and the surface conductivity can be measured in situ. The surface structures were observed by reflection electron microscopy and diffraction (REM-RHEED). REM-RHEED enables us to observe the surface superstructures and their structure defects such as surface atomic steps and domain boundaries of the surface superstructure. Thus the effects of the defects on the surface conductivity can be investigated. In the present paper we present the surface conductivity measurement system and its application to the Si(111)-{radical}(3)x{radical}(3)-Ag surface prepared on the Si(111) vicinal surfaces. The result clearly showed that the surface conductivity was affected by step configuration.

36 MATERIALS SCIENCE↗