Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Polysilicon Gate Enhancement of the Random Dopant Induced Threshold Voltage Fluctuations in Sub-100 nm MOSFET's with Ultrathin Gate Oxide

In this paper, we investigate various aspects of the polysilicon gate influence on the random dopant induced threshold voltage fluctuations in sub-100 nm MOSFET's with ultrathin gate oxides. The study is done by using an efficient statistical three-dimensional (3-D) "atomistic" simulation technique described else-where. MOSFET's with uniform channel doping and with low doped epitaxial channels have been investigated. The simulations reveal that even in devices with a single crystal gate the gate depletion and the random dopants in it are responsible for a substantial fraction of the threshold voltage fluctuations when the gate oxide is scaled-in the range of 1-2 nm. Simulation experiments have been used in order to separate the enhancement in the threshold voltage fluctuations due to an effective increase in the oxide thickness associated with the gate depletion from the direct influence of the random dopants in the gate depletion layer. The results of the experiments show that the both factors contribute to the enhancement of the threshold voltage fluctuations, but the effective increase in the oxide-thickness has a dominant effect in the investigated range of devices. Simulations illustrating the effect or the polysilicon grain boundaries on the threshold voltage variation are also presented.

Asenov, Asen↗

Near-Threshold Rovibrational Excitation of HF by Electron Impact

The pronounced threshold peaks found in cross sections for electron-impact excitation of the vibrational levels of HF have been studied using an R-matrix method, in which electron exchange, correlation effects and polarization are included. Vibration is modelled inside the R-matrix sphere using the energy-modified adiabatic phase matrix method (EMAP). Rotation of the target molecule is treated outside the R-matrix sphere, using the frame transformation method. The external rovibronic close-coupling equations are solved by analytic methods. Analysis of the multichannel threshold structures indicates that the peaks found for rovibrational excitation of nu = 1 can be interpreted as virtual states while those for nu = 2 correspond to nuclear-excited Feshbach resonances. These two different results correspond simply to a change of sign of a small parameter that is determined by the threshold analysis. Whereas the overall shapes of the excitation peaks agree with earlier theoretical results, we have found detailed rotational fine structures for scattering energies on the order of the rotational constant above and below the opening of the vibrational channels. The partial and total cross sections for rovibrational state-to-state transitions in the energy region of the peaks are analysed. Characteristic cusp structures and excitation peaks are found at the rovibrational thresholds for transitions with small angular momentum transfer (Delta)j =0, 1 and 2. Differential cross sections are similar to recent measurements. These experimental data do not show the relatively sharp rise at the vibrational thresholds indicated by theory. Theory and experiment are in good agreement for the shape and magnitude of the angular dependence of cross sections for rovibrational state-to-state transitions, especially at larger energies.

Thummel, Helmar T.↗

Three Dimensional Constraint Effects on the Estimated (Delta)CTOD during the Numerical Simulation of Different Fatigue Threshold Testing Techniques

Variation in constraint through the thickness of a specimen effects the cyclic crack-tip-opening displacement (DELTA CTOD). DELTA CTOD is a valuable measure of crack growth behavior, indicating closure development, constraint variations and load history effects. Fatigue loading with a continual load reduction was used to simulate the load history associated with fatigue crack growth threshold measurements. The constraint effect on the estimated DELTA CTOD is studied by carrying out three-dimensional elastic-plastic finite element simulations. The analysis involves numerical simulation of different standard fatigue threshold test schemes to determine how each test scheme affects DELTA CTOD. The American Society for Testing and Materials (ASTM) prescribes standard load reduction procedures for threshold testing using either the constant stress ratio (R) or constant maximum stress intensity (K(sub max)) methods. Different specimen types defined in the standard, namely the compact tension, C(T), and middle cracked tension, M(T), specimens were used in this simulation. The threshold simulations were conducted with different initial K(sub max) values to study its effect on estimated DELTA CTOD. During each simulation, the DELTA CTOD was estimated at every load increment during the load reduction procedure. Previous numerical simulation results indicate that the constant R load reduction method generates a plastic wake resulting in remote crack closure during unloading. Upon reloading, this remote contact location was observed to remain in contact well after the crack tip was fully open. The final region to open is located at the point at which the load reduction was initiated and at the free surface of the specimen. However, simulations carried out using the constant Kmax load reduction procedure did not indicate remote crack closure. Previous analysis results using various starting K(sub max) values and different load reduction rates have indicated DELTA CTOD is independent of specimen size. A study of the effect of specimen thickness and geometry on the measured DELTA CTOD for various load reduction procedures and its implication in the estimation of fatigue crack growth threshold values is discussed.

Seshadri, Banavara R.↗

Optimal Dynamic Sub-Threshold Technique for Extreme Low Power Consumption for VLSI

For miniaturization of electronics systems, power consumption plays a key role in the realm of constraints. Considering the very large scale integration (VLSI) design aspect, as transistor feature size is decreased to 50 nm and below, there is sizable increase in the number of transistors as more functional building blocks are embedded in the same chip. However, the consequent increase in power consumption (dynamic and leakage) will serve as a key constraint to inhibit the advantages of transistor feature size reduction. Power consumption can be reduced by minimizing the voltage supply (for dynamic power consumption) and/or increasing threshold voltage (V(sub th), for reducing leakage power). When the feature size of the transistor is reduced, supply voltage (V(sub dd)) and threshold voltage (V(sub th)) are also reduced accordingly; then, the leakage current becomes a bigger factor of the total power consumption. To maintain low power consumption, operation of electronics at sub-threshold levels can be a potentially strong contender; however, there are two obstacles to be faced: more leakage current per transistor will cause more leakage power consumption, and slow response time when the transistor is operated in weak inversion region. To enable low power consumption and yet obtain high performance, the CMOS (complementary metal oxide semiconductor) transistor as a basic element is viewed and controlled as a four-terminal device: source, drain, gate, and body, as differentiated from the traditional approach with three terminals: i.e., source and body, drain, and gate. This technique features multiple voltage sources to supply the dynamic control, and uses dynamic control to enable low-threshold voltage when the channel (N or P) is active, for speed response enhancement and high threshold voltage, and when the transistor channel (N or P) is inactive, to reduce the leakage current for low-leakage power consumption.

Duong, Tuan A.↗

Uncertainties in the Modelled CO2 Threshold for Antarctic Glaciation

frequently cited atmospheric CO2 threshold for the onset of Antarctic glaciation of approximately780 parts per million by volume is based on the study of DeConto and Pollard (2003) using an ice sheet model and the GENESIS climate model. Proxy records suggest that atmospheric CO2 concentrations passed through this threshold across the Eocene-Oligocene transition approximately 34 million years. However, atmospheric CO2 concentrations may have been close to this threshold earlier than this transition, which is used by some to suggest the possibility of Antarctic ice sheets during the Eocene. Here we investigate the climate model dependency of the threshold for Antarctic glaciation by performing offline ice sheet model simulations using the climate from 7 different climate models with Eocene boundary conditions (HadCM3L, CCSM3, CESM1.0, GENESIS, FAMOUS, ECHAM5 and GISS_ER). These climate simulations are sourced from a number of independent studies, and as such the boundary conditions, which are poorly constrained during the Eocene, are not identical between simulations. The results of this study suggest that the atmospheric CO2 threshold for Antarctic glaciation is highly dependent on the climate model used and the climate model configuration. A large discrepancy between the climate model and ice sheet model grids for some simulations leads to a strong sensitivity to the lapse rate parameter.

simulation↗

A New Load Residual Threshold Definition for the Evaluation of Wind Tunnel Strain-Gage Balance Data

A new definition of a threshold for the detection of load residual outliers of wind tunnel strain-gage balance data was developed. The new threshold is defined as the product between the inverse of the absolute value of the primary gage sensitivity and an empirical limit of the electrical outputs of a strain{gage. The empirical limit of the outputs is either 2.5 microV/V for balance calibration or check load residuals. A reduced limit of 0.5 microV/V is recommended for the evaluation of differences between repeat load points because, by design, the calculation of these differences removes errors in the residuals that are associated with the regression analysis of the data itself. The definition of the new threshold and different methods for the determination of the primary gage sensitivity are discussed. In addition, calibration data of a six-component force balance and a five-component semi-span balance are used to illustrate the application of the proposed new threshold definition to different types of strain{gage balances. During the discussion of the force balance example it is also explained how the estimated maximum expected output of a balance gage can be used to better understand results of the application of the new threshold definition.

load residuals↗

Experimental and Finite Element Modeling of Near-Threshold Fatigue Crack Growth for the K-Decreasing Test Method

The experimental methods to determine near-threshold fatigue crack growth rate data are prescribed in ASTM standard E647. To produce near-threshold data at a constant stress ratio (R), the applied stress-intensity factor (K) is decreased as the crack grows based on a specified K-gradient. Consequently, as the fatigue crack growth rate threshold is approached and the crack tip opening displacement decreases, remote crack wake contact may occur due to the plastically deformed crack wake surfaces and shield the growing crack tip resulting in a reduced crack tip driving force and non-representative crack growth rate data. If such data are used to life a component, the evaluation could yield highly non-conservative predictions. Although this anomalous behavior has been shown to be affected by K-gradient, starting K level, residual stresses, environmental assisted cracking, specimen geometry, and material type, the specifications within the standard to avoid this effect are limited to a maximum fatigue crack growth rate and a suggestion for the K-gradient value. This paper provides parallel experimental and computational simulations for the K-decreasing method for two materials (an aluminum alloy, AA 2024-T3 and a titanium alloy, Ti 6-2-2-2-2) to aid in establishing clear understanding of appropriate testing requirements. These simulations investigate the effect of K-gradient, the maximum value of stress-intensity factor applied, and material type. A material independent term is developed to guide in the selection of appropriate test conditions for most engineering alloys. With the use of such a term, near-threshold fatigue crack growth rate tests can be performed at accelerated rates, near-threshold data can be acquired in days instead of weeks without having to establish testing criteria through trial and error, and these data can be acquired for most engineering materials, even those that are produced in relatively small product forms.

Smith, Stephen W.↗

Characterizing the Effects of a Vertical Time Threshold for a Class of Well-Clear Definitions

A fundamental requirement for the integration of unmanned aircraft into civil airspace is the capability of aircraft to remain well clear of each other and avoid collisions. This requirement has led to a broad recognition of the need for an unambiguous, formal definition of well clear. It is further recognized that any such definition must be interoperable with existing airborne collision avoidance systems (ACAS). A particular class of well-clear definitions uses logic checks of independent distance thresholds as well as independent time thresholds in the vertical and horizontal dimensions to determine if a well-clear violation is predicted to occur within a given time interval. Existing ACAS systems also use independent distance thresholds, however a common time threshold is used for the vertical and horizontal logic checks. The main contribution of this paper is the characterization of the effects of the decoupled vertical time threshold on a well-clear definition in terms of (1) time to well-clear violation, and (2) interoperability with existing ACAS. The paper provides governing equations for both metrics and includes simulation results to illustrate the relationships. In this paper, interoperability implies that the time of well-clear violation is strictly less than the time a resolution advisory is issued by ACAS. The encounter geometries under consideration in this paper are initially well clear and consist of constant-velocity trajectories resulting in near-mid-air collisions.

Upchurch, Jason M.↗

An Abrupt Transition to an Intergranular Failure Mode in the Near-Threshold FCG Regime in Ni-Based Superalloys

Cyclic near-threshold FCG behavior of two disk superalloys was evaluated, and was shown to exhibit an unexpected sudden failure mode transition from a mostly transgranular failure mode at higher stress intensities to an almost completely intergranular failure mode in the threshold regime. The change in failure modes was associated with a crossover effect in which the conditions that produced higher FCG rates in the Paris regime resulted in lower FCG rates and increased ΔKth values in the threshold region. High resolution scanning and transmission electron microscopy was used to carefully characterize the crack tips at these near-threshold conditions. Formation of stable Al-oxide followed by Cr and Ti oxides was found to occur at the crack tip prior to formation of unstable oxides. To contrast with the threshold failure mode regime, a quantitative assessment of the role that the intergranular failure mode has on cyclic FCG behavior in the Paris regime was also performed. It was demonstrated that the even a very limited intergranular failure content dominates the FCG response under mixed mode failure conditions.

fatigue crack growth↗

An Abrupt Transition to an Intergranular Failure Mode in the Near-Threshold Fatigue Crack Growth Regime in Ni-Based Superalloys

Cyclic near-threshold fatigue crack growth (FCG) behavior of two disk superalloys was evaluated and was shown to exhibit an unexpected sudden failure mode transition from a mostly transgranular failure mode at higher stress intensity factor ranges to an almost completely intergranular failure mode in the threshold regime. The change in failure modes was associated with a crossover of FCG resistance curves in which the conditions that produced higher FCG rates in the Paris regime resulted in lower FCG rates and increased Kth values in the threshold region. High-resolution scanning and transmission electron microscopy were used to carefully characterize the crack tips at these near-threshold conditions. Formation of stable Al-oxide followed by Cr-oxide and Ti-oxides was found to occur at the crack tip prior to formation of unstable oxides. To contrast with the threshold failure mode regime, a quantitative assessment of the role that the intergranular failure mode has on cyclic FCG behavior in the Paris regime was also performed. It was demonstrated that even a very limited intergranular failure content dominates the FCG response under mixed mode failure conditions.

Telesman, J.↗

Measurement and interpretation of threshold stress intensity factors for steels in high-pressure hydrogen gas.

Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} is the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.

08 HYDROGEN↗

Methods for automatic trigger threshold adjustment

Methods are presented for adjusting trigger threshold values to compensate for drift in the quiescent level of a signal monitored for initiating a data recording event, thereby avoiding false triggering conditions. Initial threshold values are periodically adjusted by re-measuring the quiescent signal level, and adjusting the threshold values by an offset computation based upon the measured quiescent signal level drift. Re-computation of the trigger threshold values can be implemented on time based or counter based criteria. Additionally, a qualification width counter can be utilized to implement a requirement that a trigger threshold criterion be met a given number of times prior to initiating a data recording event, further reducing the possibility of a false triggering situation.

47 OTHER INSTRUMENTATION↗

Frequency threshold determination for frequency-responsive load controllers

Systems, methods, and computer media for managing frequency response in a power grid are provided herein. Individual grid-connected electrical devices can be turned on and/or off by corresponding frequency-responsive load controllers when frequency deviations beyond a threshold are detected. Each controller selects, for the corresponding electrical device, a frequency threshold from available frequencies in a frequency range. If the selected frequency falls within a deadband frequency range, then the controller sets the frequency threshold to a frequency outside of the deadband (e.g., to a closest available frequency outside of the deadband). On a system-wide level, this approximates a uniform distribution of frequency thresholds over the entire frequency range, including the deadband, and achieves the proper power-to-frequency relationship for grid stability. A supervisory coordinator can determine the frequency range from which a frequency threshold is selected based on aggregated power information for devices and controllers throughout the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PET CT Thresholds for Radiotherapy Target Definition in Non-Small-Cell Lung Cancer: How Close are we to the Pathologic Findings?

Purpose: Optimal target delineation threshold values for positron emission tomography (PET) and computed tomography (CT) radiotherapy planning is controversial. In this present study, different PET CT threshold values were used for target delineation and then compared pathologically. Methods and Materials: A total of 31 non-small-cell lung cancer patients underwent PET CT before surgery. The maximal diameter (MD) of the pathologic primary tumor was obtained. The CT-based gross tumor volumes (GTV{sub CT}) were delineated for CT window-level thresholds at 1,600 and -300 Hounsfield units (HU) (GTV{sub CT1}); 1,600 and -400 (GTV{sub CT2}); 1,600 and -450 HU (GTV{sub CT3}); 1,600 and -600 HU (GTV{sub CT4}); 1,200 and -700 HU (GTV{sub CT5}); 900 and -450 HU (GTV{sub CT6}); and 700 and -450 HU (GTV{sub CT7}). The PET-based GTVs (GTV{sub PET}) were autocontoured at 20% (GTV{sub 20}), 30% (GTV{sub 30}), 40% (GTV{sub 40}), 45% (GTV{sub 45}), 50% (GTV{sub 50}), and 55% (GTV{sub 55}) of the maximal intensity level. The MD of each image-based GTV in three-dimensional orientation was determined. The MD of the GTV{sub PET} and GTV{sub CT} were compared with the pathologically determined MD. Results: The median MD of the GTV{sub CT} changed from 2.89 (GTV{sub CT2}) to 4.46 (GTV{sub CT7}) as the CT thresholds were varied. The correlation coefficient of the GTV{sub CT} compared with the pathologically determined MD ranged from 0.76 to 0.87. The correlation coefficient of the GTV{sub CT1} was the best (r = 0.87). The median MD of GTV{sub PET} changed from 5.72cm to 2.67cm as the PET thresholds increased. The correlation coefficient of the GTV{sub PET} compared with the pathologic finding ranged from 0.51 to 0.77. The correlation coefficient of GTV{sub 50} was the best (r = 0.77). Conclusion: Compared with the MD of GTV{sub PET}, the MD of GTV{sub CT} had better correlation with the pathologic MD. The GTV{sub CT1} and GTV{sub 50} had the best correlation with the pathologic results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strong-Drive Limits in Josephson Circuits: From Chaos to an Unbound-Resonance Threshold

Strong microwave drives enable fast measurement and parametric control in superconducting circuits but can induce transitions out of the intended low-energy manifold. We develop a unified description of strong-drive limits in flux- and charge-driven Josephson circuits across drive frequency and dc flux bias. Using classical phase-space analysis and Floquet--Markov simulations, we identify distinct low- and high-frequency mechanisms. At low frequency, we characterize bound-state resonances and separatrix chaos and find that the flux-drive chaos threshold depends strongly on dc flux bias. At high frequency, these mechanisms are suppressed, and the dissipative steady state transfers from the central bound-state sector to outer resonances formed by above-barrier running trajectories. The resulting unbound-resonance threshold is nearly independent of drive frequency and circuit parameters over the regime studied and is controlled primarily by dc flux bias. Coherent simulations show that parametric operation persists beyond this threshold, but at a reduced rate, setting an effective upper bound on the achievable operation speed. We derive analytical criteria for both thresholds, validate them numerically, and experimentally confirm the predicted dc-bias dependence of the low-frequency threshold in a flux-driven SQUID. We also determine the timescales for transfer into the unbound-resonance regime and relaxation back to the bound-state manifold after the drive is removed. Finally, we relate the stability limits to a complementary picture based on the junction critical current and extend the framework to multitone drives and inductively shunted circuits. Together, these results identify the mechanisms limiting strong driving and suggest routes to extend the stable operating range of Josephson circuits.

You, Xinyuan [Fermilab] (ORCID:0000000291789419)↗

A temperature threshold to identify the driving climate forces of the respiratory process in terrestrial ecosystems

Terrestrial ecosystem respiration (R e ) is the second largest carbon flux between the biosphere and atmosphere. Therefore, climate-driven changes of Re greatly impact on future atmospheric CO 2 concentration. The aim of this study was to derive an air temperature threshold to identify the driving climate forces of the respiratory process in terrestrial ecosystems within different temperature zones. A global dataset of 647 site-years of ecosystem flux data and related variables were collected at 152 sites. The quantile regression was applied to evaluate relationships between the maximum realizable Re rates and mean annual air temperature (MAT) as well as other micrometeorological factors (i.e., atmospheric CO 2 concentration, atmospheric water content, soil heat flux, sensible heat flux, latent heat flux, precipitation, relative humidity, and soil water content). Our analysis revealed an ecosystem threshold of MAT of 11 ± 2.3 °C. In ecosystems with MATs lower than the threshold, the maximum R e rates were primarily dependent on temperature and respiration was mainly a temperature-driven process. In ecosystems with MATs higher than the threshold, besides MAT, other factors, such as water availability and surface heat flux, became significant driving forces of the maximum Re rates and respiration was a multi-factor-driven process. Temperature played the key role in generation of the maximum R e rates in the terrestrial ecosystems, while other driving forces reduce the maximum R e rates and the temperature sensitivity of the respiratory process. According to a regression tree analysis, MAT was also the most influencing factor of mean R e rates among the climate forces. The information from this study should be useful to predict the respiratory process in terrestrial ecosystems with different temperatures under the climate change.

54 ENVIRONMENTAL SCIENCES↗

Evaluating methods to reduce duration of near-threshold fatigue crack growth rate measurements for low-alloy steels in hydrogen gas

Measurement of the near-threshold fatigue crack growth rate (da/dN) vs. stress-intensity factor range (∆K) relationship in hydrogen gas is essential for maximizing the calculated design fatigue life of high-pressure hydrogen storage vessels. However, such measurements are rarely performed, since the low cyclic loading frequencies applied in standard practice lead to prohibitively protracted test durations. The objective of this study was to demonstrate two means for reducing test durations when measuring near-threshold da/dN vs. ΔK relationships under decreasing ΔK for low-alloy pressure vessel steels in hydrogen gas: 1) imposing steeper K-gradients relative to the recommended limits in standards such as ASTM E647, and 2) increasing cyclic loading frequency relative to typical values applied during fatigue crack growth testing of low-alloy steels in hydrogen gas. Recognizing that steeper K-gradients could amplify loading-history effects, test methods employing this approach were designed to mitigate such effects by either maintaining constant K max or gradually increasing the K-gradient as the threshold was approached. Although the varying K-gradient method was vulnerable to loading-history effects in the form of plasticity-induced crack closure, particularly at lower stress ratio (R) and higher starting K max values, these effects could be compensated by applying the adjusted compliance ratio (ACR) method. Here, it was demonstrated that steeper K-gradients in concert with increased cyclic loading frequency reduced the duration of near-threshold fatigue crack growth tests in hydrogen gas by more than 99% relative to standard practices.

Fatigue threshold↗

Quantitative Observation of Threshold Defect Behavior in Memristive Devices with Operando X-ray Microscopy

Memristive devices are an emerging technology that enables both rich interdisciplinary science and novel device functionalities, such as nonvolatile memories and nanoionics-based synaptic electronics. Recent work has shown that the reproducibility and variability of the devices depend sensitively on the defect structures created during electroforming as well as their continued evolution under dynamic electric fields. However, a fundamental principle guiding the material design of defect structures is still lacking due to the difficulty in understanding dynamic defect behavior under different resistance states. Here, we unravel the existence of threshold behavior by studying model, single-crystal devices: resistive switching requires that the pristine oxygen vacancy concentration reside near a critical value. Theoretical calculations show that the threshold oxygen vacancy concentration lies at the boundary for both electronic and atomic phase transitions. Through operando , multimodal X-ray imaging, we show that field tuning of the local oxygen vacancy concentration below or above the threshold value is responsible for switching between different electrical states. Lastly, these results provide a general strategy for designing functional defect structures around threshold concentrations to create dynamic, field-controlled phases for memristive devices.

36 MATERIALS SCIENCE↗