Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Ultrafast Adsorbate Excitation Probed with Subpicosecond-Resolution X-Ray Absorption Spectroscopy

We use a pump-probe scheme to measure the time evolution of the C K-edge x-ray absorption spectrum from CO/Ru(0001) after excitation by an ultrashort high-intensity optical laser pulse. Because of the short duration of the x-ray probe pulse and precise control of the pulse delay, the excitation-induced dynamics during the first picosecond after the pump can be resolved with unprecedented time resolution. By comparing with density functional theory spectrum calculations, we find high excitation of the internal stretch and frustrated rotation modes occurring within 200 fs of laser excitation, as well as thermalization of the system in the picosecond regime. The ~100 fs initial excitation of these CO vibrational modes is not readily rationalized by traditional theories of nonadiabatic coupling of adsorbates to metal surfaces, e.g., electronic frictions based on first order electron-phonon coupling or transient population of adsorbate resonances. Finally, we suggest that coupling of the adsorbate to nonthermalized electron-hole pairs is responsible for the ultrafast initial excitation of the modes.

47 OTHER INSTRUMENTATION↗

In-Situ Laser Diagnostics to Understand Plasma-Surface Interactions in Titanium Thin Film Deposition

During the current project period the following tasks were completed: (1) We demonstrated the feasibility of a new way of measuring CH3 radicals in a plasma environment using a single, femtosecond (fs) pulsed laser for the first time, in a CH4 + Ar flow. A single fs pulsed Ti:Sa laser was split into two beams and with beam conversion using crystals we generatedtwo beams of 275 nm and 205 nm. The 275 nm was used to predissociate the CH3 radicals to CH2+H, followed by 205 nm Two Photon Laser Induced Fluorescence (TALIF) detection of H atoms, with a 11 ns delay from 275 nm predissociation pulse. (2) We demonstrated preliminary CH3 concentration measurements with spatial (< 100 µm) and time resolution (< 10 ns) by image processing of H and Kr TALIF signal images. (3) The methodology to quantify CH3 concentrations was developed. (4) Preliminary measurements of laser dissociation cross sections for CH4 and CH3 to (CH3+H), and (CH2+H), respectively, were conducted. (5) 275 nm laser dissociation of CH4 is a multiphoton process, and the CH4 dissociation cross section is a more sensitive function of the laser pulse energy than CH4 concentration. In the coming months, we will make more precise measurements of the dissociation cross sections, 𝑘275, 𝐶𝐻4 and 𝑘275, 𝐶𝐻3, by varying the laser energy while keeping the flow composition and conditions constant. This will enable more precise quantification of CH3 radical concentrations. More detailed measurements of CH3 radicals will be conducted in the following months of 2025 (Sept-Dec) in a Titanium Isopropoxide (TIP) + H2 + Ar flow meant for pure phase Ti thin film deposition by Chemical Vapor Deposition (CVD). More precise measurements of 275 nm laser dissociation cross sections for CH4 (to CH3 + H) and CH3 (to CH2 + H) will be conducted in the future. Detailed 275 nm laser predissociation cross sections for CH4 and CH3 dissociation to (CH3+H), and (CH2+H), respectively, as a function of gas heating, plasma power, and laser pulse energy will be evaluated. This will enable quantification of CH3 concentrations in the precursor flow over a substrate with time and spatial resolution. Comparison of the concentrations with 2D numerical simulations can lead to understanding of plasma surface interactions during pure metallic Ti thin film deposition using environmentally safer non-halogen TIP precursor. Flow conditions for pure Ti thin film deposition using non-halogen precursor (TIP) will be identified in the following months.

Uddi, Mruthunjaya [Advanced Cooling Technologies, ↗

Single-photoelectron collection efficiency in 4D ultrafast electron microscopy

In femtosecond (fs) 4D ultrafast electron microscopy (UEM), a tradeoff is made between photoelectrons per packet and time resolution. One consequence of this can be longer-than-desirable acquisition times for low-density packets, and particularly for low repetition rates when complete photothermal dissipation is required. Thus, gaining an understanding of photoelectron trajectories in the gun region is important for identifying factors that limit collection efficiency (CE; fraction of photoelectrons that enter the illumination system). Here, we continue our work on the systematic study of photoelectron trajectories in the gun region of a Thermo Fisher/FEI Tecnai Femto UEM, focusing specifically on CE in the single-electron regime. Using General Particle Tracer, calculated field maps, and the exact architecture of the Tecnai Femto UEM, we simulated the effects of fs laser parameters and key gun elements on CE. The results indicate CE strongly depends upon the laser spot size on the source, the (unbiased) Wehnelt aperture diameter, and the incident photon energy. The CE dispersion with laser spot size is found to be strongly dependent on aperture diameter, being nearly dispersionless for the largest apertures. A gun crossover is also observed, with the beam-waist position being dependent on the aperture diameter, further illustrating that the Wehnelt aperture acts as a simple, fixed electrostatic lens in UEM mode. This work provides further insights into the operational aspects of fs 4D UEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ambient Aerosol Is Physically Larger on Cloudy Days in Bondville, Illinois

Particle chemical composition affects aerosol optical and physical properties in ways important for the fate, transport, and impact of atmospheric particulate matter. For example, hygroscopic constituents take up water to increase the physical size of a particle, which can alter the extinction properties and atmospheric lifetime. At the collocated AERosol RObotic NETwork (AERONET) and Interagency Monitoring of PROtected Visual Environments (IMPROVE) network monitoring stations in rural Bondville, Illinois, we employ a novel cloudiness determination method to compare measured aerosol physicochemical properties on predominantly cloudy and clear sky days from 2010 to 2019. On cloudy days, aerosol optical depth (AOD) is significantly higher than on clear sky days in all seasons. Measured angstrom ngstro''m exponents are significantly smaller on cloudy days, indicating physically larger average particle size for the sampled populations in all seasons except winter. Mass concentrations of fine particulate matter that include estimates of aerosol liquid water (ALW) are higher on cloudy days in all seasons but winter. More ALW on cloudy days is consistent with larger particle sizes inferred from angstrom ngstro''m exponent measurements. Aerosol chemical composition that affects hygroscopicity plays a determining impact on cloudy versus clear sky differences in AOD, angstrom ngstro''m exponents, and ALW. This work highlights the need for simultaneous collocated, high-time-resolution measurements of both aerosol chemical and physical properties, in particular at cloudy times when quantitative understanding of tropospheric composition is most uncertain.

54 ENVIRONMENTAL SCIENCES↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Hard x-ray imaging and characterization of staged z-pinch plasmas in order to exclude ion beams as cause of fusion

Prior to the start of the INFUSE project, a 1-D x-ray device had been developed to detect > 5 keV x-rays and, by using the device as a pinhole camera, determine the location of the source of these x-rays. The system was also used in a non-camera mode to measure the energy of the X-rays by having different thicknesses of attenuating material on different pixels. This dual-purpose had been used in three plasma experiments: the laboratory magnetized plasma jet at Caltech, the laboratory solar nanoflare at Caltech, and at the 500 kA staged Z-pinch (CESZAR) at UCSD. Preliminary measurements at the UCSD facility indicated that hard x-rays with energies ranging from ~27 to over 100 keV were created and that these x-rays likely originated at the Z-pinch’s anode. These preliminary data also indicated that the x-rays’ origin was coincident with the moment of peak compression. The major goal of the INFUSE proposal was to confirm these preliminary results. This confirmation was to be made by improving the imaging capability to two dimensions, increasing the time resolution of the camera, and using the x-ray diagnostic alongside time-resolved neutron detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗

Lambda baryon production in neutrino-nucleus interactions and light signals reconstruction in the Short-Baseline Near Detector

The field of neutrino physics is nowadays entering the era of precision measurements, with new detectors capable of capturing neutrino interactions with unprecedented detail and high intensity neutrino beams. Liquid Argon Time Projection Chambers (LArTPCs) have become one of the main neutrino detection technologies, providing excellent imaging capabilities and particle identification. The Short-Baseline Near Detector (SBND) at Fermilab is a LArTPC experiment designed to capture neutrinos from the Booster Neutrino Beam (BNB). Its proximity to the beam target (110\,m) and large size (112\,ton) enable the recording of millions of neutrino interactions annually. SBND provides the highest statistics worldwide for neutrino-argon cross-section measurements, facilitating the study of rare channels like Cabibbo-suppressed quasielastic hyperon production. Specifically, this thesis focuses on neutral $\Lambda$ baryon production for which only tens of events have been observed up to date. Our work introduces a novel selection strategy leveraging LArTPC imaging capabilities to identify the distinctive decay signatures of $\Lambda$ baryons, enhancing sensitivity to this channel. Besides being a very mature technology, LArTPCs are an evolving technology. Part of the focus of the new developments lies in harnessing the potential of scintillation light signals. The Photon Detection System (PDS) in SBND has been designed to provide an efficient detection of the scintillation light, representing a major R\&D opportunity in the LArTPC community. Its design provides a high and more uniform light yield, an excellent timing resolution and an independent 3D reconstruction of the events, including the drift coordinate, using exclusively the light signals. This work presents the first comprehensive study of the SBND PDS capabilities. The new developments in the simulation and reconstruction of the light signals in SBND are presented. The whole chain is applied to accurately tag neutrino events through timing information, with a predicted resolution $\mathcal{O}$(2\,ns), and ultimately retrieve the pulse structure of the BNB.

43 PARTICLE ACCELERATORS↗

Measurement of Stark-split beam and carbon charge exchange emissions for simultaneous B-field and temperature/rotation analysis at DIII-D

A set of two newly designed, single-channel Czerny–Turner spectrometers has been deployed at the DIII-D tokamak for measurements of the motional Stark effect (MSE) split beam emission and the C6+ (CVI) carbon charge exchange recombination (CER) emission at high spectral (δλ = 0.13 nm) and temporal (1–5 kHz) resolution. High throughput optics (f/# = 2.8) allow for good signal-to-noise at high time resolution using fast EMCCD detectors. The MSE emission allows for spectral fitting of the magnitude and direction of the local B-field, while the carbon emission yields local ion temperature and toroidal rotation information. To reduce so-called Doppler broadening of the MSE emission, a new channel-specific variable lens-masking approach has been developed. Experimental data collected from the 2023 DIII-D experimental campaign demonstrate the signal quality and instrument fidelity for both diagnostic measurements. Moreover, initial CER data analysis shows a clear evolution of the toroidal rotation during edge localized modes. Initial progress on the advanced MSE model, including a new validated ray-trace model of the DIII-D collection optics, is shown via sensitivity analysis.

Instruments & Instrumentation↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Investigation of cosmic ray impact on transmon qubits with different materials through fast decay detection at Fermilab’s SQMS laboratory

Noise sources affecting superconducting qubits, such as cosmic rays and ambient gamma radiation, have garnered attention for their potential impact. These radiations deposit energy in the qubit's substrate, generating high-energy phonons that break Cooper pairs, leading to the formation of quasi-particles. When these quasi-particles tunnel across Josephson junctions, they induce qubit de-excitation, causing relaxation errors. In this study, we employ a fast feedback mechanism for performing qubit reset to detect decay events with high time resolution. This capability along with frequency multiplexed readout allows us to explore error correlations across time and space. Transmon qubits, manufactured within the Superconducting Quantum Materials and Systems (SQMS) center [1], are investigated at the above-ground lab. We study the impact of cosmic rays on qubits with different encapsulations, geometries, and locations on the same or different chips. We present preliminary findings and discuss the implications for the performance of contemporary quantum hardware.

Roy, Tanay↗

In-situ observation of trapped carriers in organic metal halide perovskite films with ultra-fast temporal and ultra-high energetic resolutions

Abstract We in-situ observe the ultrafast dynamics of trapped carriers in organic methyl ammonium lead halide perovskite thin films by ultrafast photocurrent spectroscopy with a sub-25 picosecond time resolution. Upon ultrafast laser excitation, trapped carriers follow a phonon assisted tunneling mechanism and a hopping transport mechanism along ultra-shallow to shallow trap states ranging from 1.72–11.51 millielectronvolts and is demonstrated by time-dependent and independent activation energies. Using temperature as an energetic ruler, we map trap states with ultra-high energy resolution down to < 0.01 millielectronvolt. In addition to carrier mobility of ~4 cm 2 V −1 s −1 and lifetime of ~1 nanosecond, we validate the above transport mechanisms by highlighting trap state dynamics, including trapping rates, de-trapping rates and trap properties, such as trap density, trap levels, and capture-cross sections. In this work we establish a foundation for trap dynamics in high defect-tolerant perovskites with ultra-fast temporal and ultra-high energetic resolution.

36 MATERIALS SCIENCE↗

Multifrequency-resolved Hanbury Brown–Twiss effect

The Hanbury Brown–Twiss (HBT) effect holds a pivotal place in intensity interferometry and gave a seminal contribution to the development of quantum optics. To observe such an effect, both good spectral and timing resolutions are necessary. Most often, the HBT effect is observed for a single frequency at a time due to its limitations in dealing with multifrequencies simultaneously, halting and limiting some applications. Here, we report a fast and data-driven spectrometer built with a one-dimensional array of single-photon-sensitive avalanche diodes. We report observing the HBT effect for multiple frequencies at the same time. In particular, we observe the HBT effect for up to five lines of the Ne spectrum, but this can be improved upon to include more lines. Our work represents a major step in making spectral binning and multifrequency HBT more widely available. The technology we present can benefit both classical and quantum applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrafast formation of domain walls of a charge density wave in SmTe 3

We study ultrafast x-ray diffraction on the charge density wave (CDW) of SmTe 3 using an x-ray free-electron laser. The high momentum and time resolution afforded by the x-ray laser enabled capturing fine wave-vector and time-dependent features of the CDW that originate from fast (in time) and sharp (in real space) variations of the CDW lattice distortion, which we attribute to an inversion of the order parameter. These domain inversions occur near the surface and are caused by the short penetration depth of the near-infrared pump with the wavelength centered at 800 nm, resulting in CDW domain walls perpendicular to the sample surface. These domain walls break the CDW long-range order on the scale of the x-ray probe depth, controlled experimentally by the x-ray incidence angle and suppress the diffraction intensity of the CDW for times much longer than the ~1–ps recovery of the electronic gap observed in time and angle-resolved photoemission spectroscopy. We model the spatial and temporal dependences of the order parameter using a simple Ginzburg-Landau model with all the parameters obtained from the published literature. We find reasonable agreement between the calculated and the measured diffraction across the momentum, time, fluence, and incidence angle dependence without adjusting any parameters. In conclusion, we reconstruct the spatial and temporal dependences of the lattice order parameter and find that at long times, depending on the pump fluence, multiple domain walls remain at distances of a few nanometers from the surface.

36 MATERIALS SCIENCE↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗