Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOUGH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Effect of Thin-Film Adhesives on Mode I Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

A single sheet of NiTi shape memory alloy (SMA) was introduced within a unidirectional HexPly® 8552/IM7 (Hexcel®) polymer matrix composite (PMC) panel in conjunction with multiple thin-film adhesives to promote the interfacial bond strength between the SMA and PMC. A double cantilever beam (DCB) test was performed in accordance with the ASTM D5528 method for evaluation of Mode I interlaminar fracture toughness of unidirectional fiber-reinforced PMCs. The modal acoustic emissions (MAEs) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels were subjected to a C-scan before testing and examined using optical and scanning electron microscopy (SEM) techniques after part failure. The data were used in conjunction with modified beam theory (MBT), the compliance calibration (CC) method, and the modified compliance calibration (MCC) method. The Mode I interlaminar toughness (G(sub IC)) values for control specimens were higher than previously reported and are attributed to extensive fiber bridging during testing. The presence of adhesives with SMA inserts stabilized crack propagation during DCB testing. The results reveal a new phenomenon of SMA bridging, whereby crack propagation would switch from one side of the SMA insert to the other, thus increasing the load and G(sub IC) values of specimens containing SMA.

shape memory alloys↗

The Effect of Thin Film Adhesives on Mode I Interlaminar Fracture Toughness in Carbon Fiber Composites with Shape Memory Alloy Inserts

Shape Memory Alloy (SMA) was placed within Polymer Matrix Composite (PMC) panels alongside film adhesives to examine bonding. Double cantilever beam (DCB) testing was performed using ASTM D5528. C-scanning was performed before testing, modal acoustic emissions (MAE) were monitored during testing, and microscopy performed post-test. Data was analyzed using modified beam theory (MBT), compliance calibration (CC) and modified compliance calibration (MCC) methods. Fracture toughness for control specimens was higher than previously reported due to fiber-bridging. Specimens with SMAs and adhesives stabilized crack propagation. Results revealed SMA-bridging; a phenomenon mimicking fiber-bridging which increased the load and fracture toughness of SMA specimens.

Derek J Quade↗

Reexamination of the Edge Crack Torsion Test for Determining the Mode III Delamination Toughness of Laminated Composites

The edge crack torsion (ECT) test is reexamined to address two primary concerns with this method. The first of these relates to inconsistencies in the data reduction procedure that was originally proposed and is most commonly used to compute the mode III interlaminar fracture toughness, G(sub IIIc), from the experimental data. The second relates to the observation that plies neighboring the preimplanted insert in the standard ECT layup are unable to contain initiation and growth of intralaminar cracks, and that growth of these cracks contributes to errors in the apparent values of G(sub IIIc). To address these issues, an alternative data reduction technique, which uses a polynomial expression to represent the ECT specimen’s compliance versus crack length relation, is proposed. The accuracy and potential drawbacks of this expression are investigated using FE simulations. Next, seven groups of ECT specimens are fabricated and tested. Each of these groups contains specimens with preimplanted inserts that are bounded by plies at different +q and -q orientations. The seven groups consist of values of q that vary from 0° to 90° in 15° increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except those for which q equals 15° or 30°. However, values of G(sub IIIc) measured using specimens with these two ply orientations were not equal and, for q = 30°, the values of G(sub IIIc) that were obtained were not completely independent of initial starter crack length. Potential issues accounting for these observations and other challenges associated with measuring G(sub IIIc) using the ECT test are discussed.

Polymer matrix composites↗

Survey of fracture toughness test methods

Comprehensive survey presents current methods of fracture toughness testing that are based on linear elastic fracture mechanics. General principles of the basic two dimensional crack stress field model are discussed in relation to real three dimensional specimens. Methods of test instrumentation and procedure are described.

Brown, W. F., Jr.↗