Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSMISSION LINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Longitudinal variations of very-low-frequency chorus activity in the magnetosphere - Evidence of excitation by electrical power transmission lines

The distribution of VLF chorus in the high-altitude magnetosphere as detected by the Ogo 3 satellite was investigated. Chorus occurrence frequency over 4,668 samples of 5 min of broadband data was computed for Northern Hemisphere bins of 10 deg by 10 deg in dipole invariant latitude and longitude. Peaks in activity were noted over Alaska, the eastern U.S. and Canada, western Europe, and western Siberia, and were shown not to be the result of biased sampling. It is suggested that power line radiation of only about 1 W or less at a given harmonic frequency may be sufficient to stimulate the observed chorus activity and that such power levels can be expected in industrial areas or from large distribution networks. Preliminary results show that chorus starting frequencies are highly correlated with 60 Hz harmonics in the American sector and with 50 Hz harmonics in the European sector.

Luette, J. P.↗

Transmission line model of the interaction of a long metal wire with the ionosphere

An equivalent electric circuit model is used to study the electrodynamic interactions of long orbiting metallic tethers with the ionospheric plasma and, in particular, to derive current and potential profiles along bare metallic tethers. In contrast with other models, this approach is dynamic, enabling both the transient behavior of the wire and its final equilibrium state to be derived. A comparison with the results of other models indicates the advantage of the present approach, especially in those cases where the internal resistance of the tether plays a major role in determining the current and potential distributions.

Arnold, D. A.↗

Tether as a dynamic transmission line

The effect of longitudinal impulses on a satellite when a continuum tether from the Shuttle or Space Station is included is investigated. It is demonstrated that, taking the continuum nature of the tether into account, the sharp onset of a forcing impulse at the Shuttle end is perceived on board the satellite. The magnitude of the satellite response is diminished from that of the forcing impulse, and the response exhibits a broadened exponential tailoff. These are due primarily to the coupling between the tether and the satellite and its influence on an impinging impulsive wave, and not on the whole system as in the spring-mass model. The full impulse response function can be quite complex, showing repeated impulses as the tether wave bounces back and forth between the satellite and Shuttle, and having a different shape at each impingement on the satellite.

Gullahorn, Gordon E.↗

Rigorous analysis of a circular patch antenna excited by a microstrip transmission line

Boundary conditions are enforced on a portion of the microstrip feed line as well as the patch antenna. The integral equation for the unknown currents on the antenna and feed is solved by applying the Galerkin method of moments in the Fourier transform domain. The validity of the solution is tested by comparison of computed results with experimental data. The theoretical treatment proves to be applicable to the most common feeding arrangements, namely, the direct edge-feed and proximity coupling excitation. In the latter case, two-layer substrates having distinct dielectric constants are studied. The purpose of the study is to deduce, for a given overall substrate thickness, the smallest line-ground plane separation for which a match of the radiator to the feed line is still possible. The advantages of such a configuration are discussed.

Davidovitz, Marat↗

Microwave conductivity of laser ablated YBaCuO superconducting films and its relation to microstrip transmission line

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response was studied of laser ablated YBa2Cu3O(7-x)/LaAlO3 thin films as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

Equations For Designing Superconducting Transmission Lines

Characteristics of microwave circuits predicted accurately. Equations for propagation of quasitransverse electric and magnetic (TEM) waves along thin films of high-critical-temperature superconductors constitute basis of mathematical model useful in design of coplanar-waveguide, microstrip, and stripline microwave circuits. Model incorporated into older commercial software for computer-aided design of microwave circuit.

Antsos, Dimitrios↗

Microwave conductivity of laser ablated YBa2Cu3O(7-delta) superconducting films and its relation to microstrip transmission line performance

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response of laser ablated YBa2Cu3O(7-delta)/LaAlO3 thin films was studied as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

Microwave Conductivity of Laser Ablated YBa2Cu3O7-delta Superconducting Films and Its Relation to Microstrip Transmission Line Performance

We report on the values of the microwave conductivity in the normal (sigma(subN)) and superconducting (sigma*=sigma(sub1)-j sigma(sub2)) states of two laser ablated YBa2CU3O7(sigma) thin films at 35 GHz, in the temperature range from 20 to 300 K. The films 0.7 and 0.4 micrometers) were deposited on LaA10(sub3) by laser ablation. The conductivity was obtained from the microwave power transmitted through the films and assuming a two-fluid model. Values of sigma(subN) approximately 2.3 X 10(exp5) S/m at room temperature for both films, and of sigma(sub1) approximately 6.3 X 10(exp5) and 4.6 X 10(exp5) S/m at temperatures around 80 K were obtained for the 0.7 and 0.4 micrometer films respectively. For sigma(sub2) values of 4.9 X 10(exp6) and 5.4 X 10(exp6) S/m were obtained for the 0.7 and 0.4 micrometer films at 80 K. The expected conductor losses and Q-factor of a superconducting ring resonator were calculated using these conductivity values. The theoretical values were then compared with the experimental results obtained for a resonator fabricated from one of these films.

Bhasin, K. B.↗

Two-Frequency RF Fields Induced Multipactor in Coaxial Transmission Line

This work investigates multipactor discharge in coaxial geometry with two-frequency rf electric field Vrf [sin(𝜔𝑡+𝜃)+𝛽 sin(n(𝜔𝑡+𝜃)+𝛾)], where Vrf is the peak voltage, 𝛽 is the field strength of the second car-rier mode relative to fundamental mode, n is the ratio of two carrier fre-quencies and 𝛾 is the relative phase of second carrier mode.

43 PARTICLE ACCELERATORS↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

Multi-Gigawatt Electric Highway

Ultra-Compact Electrical Transmission Lines are a new transmission line technology that uses large, hollow, aluminum beams to carry current instead of thin wires. Capacity is 4.5 times higher, power losses are 3 times lower, and cost per mile is a little lower than conventional lines. Resilience and reliability are higher. The beams are enclosed within concrete walls and out of the weather, protected from high winds, ice storms, fires, and lightning. The 230 kV version is 9 feet high x 11 feet wide and can use existing rights of way next to existing transmission lines or highways. With a little landscaping, these transmission lines are not an eyesore and will be much easier to permit on existing rights of way.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An exact derivation of contact resistance to planar devices

A mixed boundary-value problem is formulated for an imperfect rectangular contact to a semiconducting sheet (layer). An exact model for derivation of contact resistance is developed and its solution by conformal mapping and eigenfunction expansion is presented. The expression for contact resistance is similar to that for a perfect (lossless) contact but includes an additional term containing the lowest-order coefficient in the infinite series expansion of the complex potential function. The calculated contact resistances are compared with those obtained from three approximate models: lossless contact, transmission line, and extended transmission line models. The extended transmission line model appears to be a very satisfactory approximation provided the ratio of contact length to sheet thickness is no less than 0.5.

Schuldt, S. B.↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Series tee splitter for impedance measurements

A series tee splitter comprises a primary electromagnetic transmission line and a secondary electromagnetic transmission line that is placed in a series path with the primary electromagnetic transmission line, wherein a load is attached to the end of the secondary electromagnetic transmission line and a network analyzer is connected to opposite ends of the primary electromagnetic transmission line to measure a load impedance. This configuration increases the high impedance measurement limit of the network analyzer normally seen for reflection measurements. The series tee splitter can be electrically small to provide broadband impedance information.

Halligan, Matthew↗

Feasibility and Prospects of the High Resolution Rapid Refresh Model For Dynamic Line Rating

The ampacity of transmission lines is defined as the maximum amount of current the conductor can safely carry. It is necessary for transmission line operators to apply ampacity limits due to the thermal properties of the conductor. Dynamic Line Rating (DLR) is a technology and technique that uses the environmental conditions or a set of the conditions to calculate the ampacity of the conductor. The way the DLR is calculated has depended upon some amount of physical technology to implement the solution. The High Resolution Rapid Refresh (HRRR) Model is an atmospheric model that may provide enough resolution to perform dynamic line rating without any hardware at all. The objective is to use this model to perform Dynamic Line Rating. This will solve two of the most pervasive problems in Dynamic Line Rating, how to instrument a transmission line hundreds of miles long and then how to predict near future ampacity sufficient for transmission operators to effectively use, This technique will use the Idaho National Laboratory site as the test location for analysis. The High Resolution Rapid Refresh model is a reliable, freely available, and well-maintained weather forecasting model for the entire United States of America. The model provides enough special resolution that additional local weather monitoring devices at location are not necessary to conduct dynamic line rating. The HRRR ratings are lower on average than the locally measured ratings which allows for an additional margin of safety. The adoption of using purely digital methods for dynamic line rating could allow for wide scale adoption of the technology with very little overhead expenditure of implementation.

17 WIND ENERGY↗

Sensor And Method For Detecting A Superstrate

Method and apparatus are provided for determining a superstrate on or near a sensor, e.g., for detecting the presence of an ice superstrate on an airplane wing or a road. In one preferred embodiment, multiple measurement cells are disposed along a transmission line. While the present invention is operable with different types of transmission lines, construction details for a presently preferred coplanar waveguide and a microstrip waveguide are disclosed. A computer simulation is provided as part of the invention for predicting results of a simulated superstrate detector system. The measurement cells may be physically partitioned, nonphysically partitioned with software or firmware, or include a combination of different types of partitions. In one embodiment, a plurality of transmission lines are utilized wherein each transmission line includes a plurality of measurement cells. The plurality of transmission lines may be multiplexed with the signal from each transmission line being applied to the same phase detector. In one embodiment, an inverse problem method is applied to determine the superstrate dielectric for a transmission line with multiple measurement cells.

Arndt, G. Dickey↗