Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of New Additions to OLI Software in Predicting Mercuric and Mercurous Species in Liquid Waste Operations

Speciation of mercury during the pretreatment steps of tank waste processing is critical to successful mercury removal prior to vitrification during Liquid Waste Operations (LWO) at SRS. OLI software has been used to predict mercury speciation and activity throughout LWO. The OLI software operates based on a thermodynamic framework called the Mixed Solvent Electrolyte (MSE) framework. The MSE framework allows prediction in theoretically infinitely dilute to concentrated mixtures (e.g., purely solute solutions). Before modification to the MSE framework databanks, certain critical mercury species were missing in the MSE databank, and some thermodynamic data needed to be updated for the OLI software to accurately predict mercury chemical species in SRS waste tanks. To better reflect streams across LWO, new mercury species were integrated into the MSE database. To evaluate the changes to the OLI MSE framework per the Technical Task Request (TTR) and the Task Technical and Quality Assurance Plan (TTQAP), waste stream compositions from Tanks 38, 43, and Tank 50 decontaminated salt solution (DSS) were used as model inputs. Models were developed and executed using both the old and new databases. Compositional analyses from caustic Tank 50 DSS and caustic Tanks 38 and 43 were used as the input streams. These streams represent the most comprehensive chemical data sets where both mercury and tank constituents were measured together. Results for Tank 50 DSS predict HgO as the predominant species in both databases. Both methyl and dimethyl Hg species are present when the new database is ‘on’ and are not predicted with the new database turned ‘off’. The new database predicts a greater amount of HgO and a greater fraction of it in the solid phase. Pourbaix diagrams (potential vs. pH) generated for each Tank 50 DSS were identical regardless of which database was used. Elemental Hg and HgO were predicted in the water stable region under basic conditions. Tanks 38 and 43 follow similar trends as the Tank 50 DSS models. Unlike Tanks 38 and 50 DSS, the Tank 43 Pourbaix plot shows a region of stability for an aqueous HgOHCO3 - species between approximately pH 7-11. In all streams, when MeHg+ is included in the inputs, the new database predicts aqueous MeHgOH as the dominant species. If elemental or dimethyl mercury is in the waste stream, the new database model predicts they are unchanged and remain in those states and quantities. Additionally, the total mercury values are reported for both the measured input data and the OLI output data for all considered tanks. The summary indicates that the percentage error between the measured and calculated values is less than 1% in all cases The reconciliations and generation of the Pourbaix diagrams for Tank 50 DSS took approximately ten times longer with the new database ‘on’. In addition, over the course of that time, models with the new database ‘on’ were more likely to crash or display an error. Some modest performance improvements were noted when modeling with an i7 processor versus an i5. An example error is found in Appendix A. Furthermore, Appendix B provides V&V for two chemical systems analyzed with the OLI software, results were satisfactory. It is recommended to utilize the new databases (i.e., HCO.ddb and SR-Hg.ddb) in future Savannah River Mission Completion applications of OLI to represent pseudo steady-state. Furthermore, the integration and utilization of the new databases (i.e., HCO.ddb and SR-Hg.ddb) in modeling applications (e.g., Aspen) is also recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 14H Annulus Samples Analyses

Savannah River Mission Completion (SRMC) Waste Removal and Tank Closure has requested that Savannah River National Laboratory (SRNL) perform characterization analyses of Tank 14H annulus samples in support of closure activities specifically annulus cleaning. SRMC requested assistance due to encountering relatively insoluble solids while washing the annulus with water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 14H Preliminary Cease Waste Removal Sample Analyses

Savannah River Mission Completion Waste Removal and Tank Closure requested that Savannah River National Laboratory perform characterization analyses of Tank 14H in support of closure activities, specifically preliminary cease waste removal. This report provides important characterization of the prepared filtrate and air-dried solids in the January 2026 Tank 14H sample, HTF-14-26-1,2,3,4,5,6, for I-129, Tc-99, Cs-137, and Sr-90. The results reported here were utilized by SRMC to declare preliminary cease waste removal for Tank 14H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis: Comparison of One- and Three-Dimensional Simulation of Vadose Zone Transport and Transfer to Groundwater for Selected Waste Sites

The purpose of this document is to compare 1D and 3D technetium-99 (Tc-99) VZ transport and transfer rates to groundwater for five selected waste sites (two tanks, two cribs, and one trench) to demonstrate the need to consider 3D flow and transport mechanisms and commingling of contaminant plumes originating from adjacent waste sites. The waste sites selected for the comparison evaluation are the 241-A-105 Tank in the A Farms Area model, the 216-B-18 Crib and the 216-B-25 Trench in the BC Cribs and Trenches model, the 216-B-49 Crib in the B Complex model, and the 241-SX-115 Tank in the S Farms Area model. The selected waste sites all represent different disposal or leak conditions, with and without potential impacts due to release-fluid commingling, occurring at the Hanford Site Central Plateau.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AX Farm and A Farm Third Retrieval Technology Chemical Dissolution Options Evaluation

In response to DOE-ORP direction to prepare a Practicability Evaluation for Waste Tank AX-102, and to address the Washington State Department of Ecology recommendation to evaluate the use of acid reagents for chemical dissolution, an Integrated Project Team (IPT) consisting of retrieval, process chemistry, corrosion, closure and laboratory subject matter experts was assembled to evaluate chemical dissolution options. This document provides a summary of these efforts and is intended to aid in the evaluation and third retrieval technology decision process not only for AX-102, but for all the AX and A Farm tanks, since the tanks contain similar waste and are flat-bottomed with uneven bottom plates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifying Critical Infrastructure in Imagery Data Using Explainable Convolutional Neural Networks

To date, no method utilizing satellite imagery exists for detailing the locations and functions of critical infrastructure across the United States, making response to natural disasters and other events challenging due to complex infrastructural interdependencies. This paper presents a repeatable, transferable, and explainable method for critical infrastructure analysis and implementation of a robust model for critical infrastructure detection in satellite imagery. This model consists of a DenseNet-161 convolutional neural network, pretrained with the ImageNet database. The model was provided additional training with a custom dataset, containing nine infrastructure classes. The resultant analysis achieved an overall accuracy of 90%, with the highest accuracy for airports (97%), hydroelectric dams (96%), solar farms (94%), substations (91%), potable water tanks (93%), and hospitals (93%). Critical infrastructure types with relatively low accuracy are likely influenced by data commonality between similar infrastructure components for petroleum terminals (86%), water treatment plants (78%), and natural gas generation (78%). Local interpretable model-agnostic explanations (LIME) was integrated into the overall modeling pipeline to establish trust for users in critical infrastructure applications. The results demonstrate the effectiveness of a convolutional neural network approach for critical infrastructure identification, with higher than 90% accuracy in identifying six of the critical infrastructure facility types.

97 MATHEMATICS AND COMPUTING↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Validated Finite Element Modeling Tool for Hydrodynamic Loading and Structural Analysis of Ocean Deployed Macroalgae Farms

The objective of this project was to develop and validate a fine-tuned, 3D computational modeling tool for high-fidelity simulations of macroalgae cultivation and harvest systems. To develop this tool, a full understanding of the geometric, material and hydrodynamic properties associated with farming kelp in exposed environments was necessary. Experiments and numerical modeling were done at increasing scales from 1) tank tests with a 1 m model, 2) to field tests with a 61 m culture line at a sheltered site, 3) to field tests with a 122 m culture line at an exposed site and to 4) a 5- line array at the exposed site with 186 m of culture length. The results of the experimental tank tests yielded a set of hydrodynamic drag-area coefficients for a 1 m aggregate based on densely grown kelp at 16 kg/m with a length up to 3 m as described in Fredriksson et al. This work provided the basis to model kelp as a 1 m aggregate based on in-situ geometric and material properties to include measurements of kelp blade length and width, number of blades, yield per m, material mass density and cantilever tests to obtain modulus of elasticity.

54 ENVIRONMENTAL SCIENCES↗

Testing of an AP-105 Precipitation Simulant

A tank AP-105 chemical simulant was developed and diluted with Washington River Protection Solutions (WRPS)-supplied raw water to evaluate the stability of AP Farm wastes with respect to precipitation under Direct Feed Low-Activity Waste (DFLAW)-typical waste feed staging operations. The current report provides a high-level summary of the basis for simulant selection, the recommended (and prepared) simulant chemistry, and observed stability with respect to solids formation upon simulant preparation and subsequent dilution with raw water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design, Optimization, and Control of Floating Offshore Wind Farms for Optimal Energy Production (Final report)

The uncertainty and irregularity of ocean waves and the ocean environment is a major factor in the development of commercial scale floating wind turbines as the operation of floating structures in such an environment can lead to irregular and unpredictable loading, fatigue, and ultimately a reduction in the operational life of the turbine system which affects energy production over the lifetime of the turbine. Control solutions that can limit float motions and mitigate stressful events on the structure become essential for extending lifetime and limiting the operational uncertainty of a floating wind turbine. Digital twins are computational replicas of physical systems that operate in parallel with the operation of the physical system. Given advanced knowledge of a systems input, digital twins have the ability to predict the behavior of a system in advance, which can be valuable in the control of that system. In this project, we developed and assessed potential digital twin models developed in house and openly available (OpenFast) for use in the real time control of the six degree of freedom response motions of a floating wind turbine in ocean waves. Coupling these models with near-field real time irregular sea surface (wve) measurement/sensings and prediction models, we used the digital twin to predict how the floating turbine will respond to the incoming waves. Applying this information to a motion control system of the float, one can limit and control float motions to prevent undesirable loading events/large angular motions, thus increasing system life and ultimately contributing to optimizing energy production. Due to the computational intensity of operating a digital twin in real time, we investigated the use of artificial intelligence techniques to speed-up the processes of the digital twin, as well as the wave reconstruction/prediction models. Model tank testing at the University of Rhode Island and University of Maine both validated and demonstrated the developed techniques on simple float geometries and a scale model of the NREL 15 MW reference turbine.

17 WIND ENERGY↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗