OECD MCCI Project: Category 4 Integral Test to Validate Severe Accident Codes: Core-Concrete Interaction Test Six (CCI-6) Test Plan (Rev. 6)
Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence and data for various cooling mechanisms through separate effect tests for severe accident model development, and ii) provide long-term 2-D core-concrete interaction data for code assessment and improvement. The PRG recommends that the OA design a 70 cm x 70 cm test, with two concrete side walls, using CEA siliceous concrete, 6 wt% concrete composition, early top flooding initiated when ablation is established and melt temperature has stabilized. The melt depth shall be 30 cm. The test will be designed for two specific phases. The first phase will provide for 30 cm for radial ablation and 25 cm for vertical ablation. In the event that the melt is not cooled down by top flooding during the first phase, a second and separate test phase will begin involving bottom flooding. This second phase will be initiated when axial ablation depth reaches 25 cm. The design should be mindful of the curing time of the concrete. The instrumentation should be refined to provide data on the water injection characteristics and melt temperature near the lateral walls. In response to this recommendation, the objective of this document is to provide a summary test plan for this sixth Core-Concrete Interaction (CCI-6) experiment for PRG review. Test specifications that were developed as part of the design work are provided.