Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Development of the tangent linear and adjoint models of the global online chemical transport model MPAS-CO 2 v7.3

We describe the development of the tangent linear (TL) and adjoint models of the Model for Prediction Across Scales (MPAS)-CO 2 transport model, which is a global online chemical transport model developed upon the non-hydrostatic Model for Prediction Across Scales – Atmosphere (MPAS-A). The primary goal is to make the model system a valuable research tool for investigating atmospheric carbon transport and inverse modeling. First, we develop the TL code, encompassing all CO 2 transport processes within the MPAS-CO 2 forward model. Then, we construct the adjoint model using a combined strategy involving re-calculation and storage of the essential meteorological variables needed for CO 2 transport. This strategy allows the adjoint model to undertake a long-period integration with moderate memory demands. To ensure accuracy, the TL and adjoint models undergo vigorous verifications through a series of standard tests. The adjoint model, through backward-in-time integration, calculates the sensitivity of atmospheric CO 2 observations to surface CO 2 fluxes and the initial atmospheric CO 2 mixing ratio. To demonstrate the utility of the newly developed adjoint model, we conduct simulations for two types of atmospheric CO 2 observations, namely the tower-based in situ CO 2 mixing ratio and satellite-derived column-averaged CO 2 mixing ratio (X CO 2 ). A comparison between the sensitivity to surface flux calculated by the MPAS-CO 2 adjoint model with its counterpart from CarbonTracker–Lagrange (CT-L) reveals a spatial agreement but notable magnitude differences. These differences, particularly evident for X CO 2 , might be attributed to the two model systems' differences in the simulation configuration, spatial resolution, and treatment of vertical mixing processes. Moreover, this comparison highlights the substantial loss of information in the atmospheric CO 2 observations due to CT-L's spatial domain limitation. Furthermore, the adjoint sensitivity analysis demonstrates that the sensitivities to both surface flux and initial CO 2 conditions spread out throughout the entire Northern Hemisphere within a month. MPAS-CO 2 forward, TL, and adjoint models stand out for their calculation efficiency and variable-resolution capability, making them competitive in computational cost. In conclusion, the successful development of the MPAS-CO 2 TL and adjoint models, and their integration into the MPAS-CO 2 system, establish the possibility of using MPAS's unique features in atmospheric CO 2 transport sensitivity studies and in inverse modeling with advanced methods such as variational data assimilation.

54 ENVIRONMENTAL SCIENCES↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Using Meteorological Data to Evaluate Worldwide PV Degradation Rates

Here we automate the process to enable the creation of world maps for specific PV durability metrics. The end goal is to create a tool for the creation of world maps predicting the sensitivity of modules to degradation to inform the development and utilization of module testing standards and to provide information to module designers. TMY (Typical Meteorological Year) Data was aggregated from sites around the world to render insight into factors contributing to the degradation of solar modules. The focus of aggregating data was to create a single dataset to work with utilizing Solar Irradiance values combined with Ambient Temperature, Relative Humidity, Wind Speed and Dew-Point Temperature.

14 SOLAR ENERGY↗

Baseline Graphite Characterization

Select necessary material properties Apply sampling plan Perform standardized testing Evaluate/compare properties Build NQA-1 qualified database Apply the “system” and database to the evaluation and qualification of future grades of graphite

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control: Preprint

This paper validates the effectiveness of an Artificial Intelligence (AI)-driven PV plant control and optimization approach, namely, the Automated Learner for Intermittency Control by Extrapolation (ALICE), in empowering PV plant as a dependable grid reliability service provider. The validation is performed in a realistic laboratory controller-hardware-in-the-loop (CHIL) environment, leveraging accurate PV plant modeling and standard industrial communication protocol. Simulation results, considering both varying weather conditions and active control scenarios, demonstrate the superior performance of ALICE in improving the grid service delivery precision and reducing the over-curtailment compared to a state-of-the-art approach, i.e., reference-control grouping based approach. Such a work could help mitigate risks and provide practical guidance during the field deployment of ALICE, while establishing a standardized testing framework for evaluating various PV active control strategies.

hardware-in-the-loop↗

Transient Stability Enhancement via a Scalable RL Method with VSG Parameter Tuning

This paper presents a reinforcement learning (RL)-driven strategy to improve the transient stability of power systems via tuning parameters of multiple virtual synchronous generators (VSGs). We proposed a scalable method to support RL training convergence probability and speed, even when a large number of contingencies are considered. The proposed scalable RL framework first decomposes the large number of contingencies into multiple groups and then conducts parallel training for each group, decreasing the state space and complexity of each training. Additionally, we propose a contingency grouping algorithm to streamline the RL action space and facilitate the training. The proposed method is validated across various standard test systems.

Huang, Xiaoge↗

Dynamically Learning Incentives for Load Control

As electrical generation becomes more distributed and volatile, and loads become more uncertain, controllability of distributed energy resources (DERs), regardless of their ownership status, will be necessary for grid reliability. Grid operators lack direct control over end-users' grid interactions, such as energy usage, but incentives can influence behavior -- for example, an end-user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. A key challenge in studying such incentives is the lack of data about human behavior, which usually motivates strong assumptions, such as distributional assumptions on compliance or rational utility-maximization. In this paper, we propose a general incentive mechanism in the form of a constrained optimization problem -- our approach is distinguished from prior work by modeling human behavior (e.g., reactions to an incentive) as an arbitrary unknown function. We propose feedback-based optimization algorithms to solve this problem that each leverage different amounts of information and/or measurements. We show that each converges to an asymptotically stable incentive with (near)-optimality guarantees given mild assumptions on the problem. Finally, we evaluate our proposed techniques in voltage regulation simulations on standard test beds. We test a variety of settings, including those that break assumptions required for theoretical convergence (e.g., convexity, smoothness) to capture realistic settings. In this evaluation, our proposed algorithms are able to find near-optimal incentives even when the reaction to an incentive is modeled by a theoretically difficult (yet realistic) function.

demand response↗

A test of the standard cosmological model with geometry and growth

We perform a general test of the ΛCDM and wCDM cosmological models by comparing constraints on the geometry of the expansion history to those on the growth of structure. Specifically, we split the total matter energy density, Ω M , and (for wCDM) dark energy equation of state, w, into two parameters each: one that captures the geometry, and another that captures the growth. We constrain our split models using current cosmological data, including type Ia supernovae, baryon acoustic oscillations, redshift space distortions, gravitational lensing, and cosmic microwave background (CMB) anisotropies. We focus on two tasks: (i) constraining deviations from the standard model, captured by the parameters ΔΩ M ≡ Ω M grow -Ω M geom and Δw ≡ w grow -w geom , and (ii) investigating whether the S 8 tension between the CMB and weak lensing can be translated into a tension between geometry and growth, i.e. ΔΩ M ≠ 0, Δw ≠ 0. In both the split ΛCDM and wCDM cases, our results from combining all data are consistent with ΔΩ M = 0 and Δ w = 0. If we omit BAO/RSD data and constrain the split wCDM cosmology, we find the data prefers Δw < 0 at 3.6σ significance and ΔΩ M > 0 at 4.2σ evidence. We also find that for both CMB and weak lensing, ΔΩ M and S 8 are correlated, with CMB showing a slightly stronger correlation. Furthermore, the general broadening of the contours in our extended model does alleviate the S 8 tension, but the allowed nonzero values of ΔΩ M do not encompass the S 8 values that would point toward a mismatch between geometry and growth as the origin of the tension.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward Standardized Microscale Tensile Testing for Two‐Photon Polymerization‐Fabricated Materials in Liquid

Two-photon polymerization (TPP) enables the fabrication of intricate 3D microstructures with submicron precision, offering significant potential in biomedical applications like tissue engineering. In such applications, to print materials and structures with defined mechanics, it is crucial to understand how TPP printing parameters impact the material properties in a physiologically relevant liquid environment. Herein, an experimental approach utilizing microscale tensile testing (μTT) for the systematic measurement of TPP-fabricated microfibers submerged in liquid as a function of printing parameters is introduced. Using a diurethane dimethacrylate-based resin, the influence of printing parameters on microfiber geometry is first explored, demonstrating cross-sectional areas ranging from 1 to 36 μm 2 . Tensile testing reveals Young's moduli between 0.5 and 1.5 GPa and yield strengths from 10 to 60 MPa. The experimental data show an excellent fit with the Ogden hyperelastic polymer model, which enables a detailed analysis of how variations in writing speed, laser power, and printing path influence the mechanical properties of TPP microfibers. The μTT method is also showcased for evaluating multiple commercial resins and for performing cyclic loading experiments. Collectively, this study builds a foundation toward a standardized microscale tensile testing framework to characterize the mechanical properties of TPP printed structures.

mechanical characterization↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultrasonic Testing (UT) Reference Standard for Additive Manufacturing Quality Control

Many additive manufacturing (AM) reference standards for build quality verification concentrate primarily on external features. In contrast, EPRI proposes a pair of AM reference blocks that feature only internal and embedded forms. This report presents, collates, and discusses quantitative nondestructive evaluation (NDE) results from various techniques, including visual testing (VT), radiographic testing (RT), conventional ultrasonic testing (UT), and full matrix capture/total focusing method (FMC/TFM) scanning. The blocks are intended, as part of a larger series of blocks, to evaluate build quality and the relative performance of different NDE techniques in detecting various features. The limits of detectability and the closeness of the as-built shape to the intended form for certain features are quantified, facilitating direct comparison. Upon analysis of the results of this testing, it was found that FMC/TFM was consistently superior in detection, followed by conventional UT, then VT, and lastly RT.

36 MATERIALS SCIENCE↗

Graphite Licensing (ASME) and Testing (ASTM) Technical Assistance

DOE ART Graphite R&D program is currently involved in developing the structural code for licensing the new High Temperature Reactor (HTR) designs through the ASME Boiler Pressure Vessel Code (BPVC). The basic structural design code for graphite core components has been written, approved, and within the BPVC since 2012. However, several areas within the graphite code remain to be improved, specifically the addition of material property changes resulting from environmental degradation (neutron flux and oxidation). The incorporation of this data, which can significantly affect the graphite components and alter the structural integrity of the core during operation, is proving to be an important activity. How this data will be incorporated within the code and how it will be used for license applications will be critical to a number of HTR applicants in the future. These modifications to the code must take into account the unique irradiation and oxidation response of the wide spectrum of available nuclear graphite grades currently under consideration for HTR applications. Additionally, the ASME BPVC requires material property testing within the expected operational conditions of the HTR core including neutron radiation flux, elevated temperatures, and after chronic/acute oxidation of the graphite components. Currently, no standardized graphite testing methods are approved for these environmental conditions. New American Society for Testing and Materials (ASTM) standardized tests for elevated temperature testing, small sample testing, and testing after oxidation must be developed to support the requirements within the ASME code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Superallowed Nuclear Beta Decays and Precision Tests of the Standard Model

For many decades, the main source of information on the top-left corner element of the Cabibbo–Kobayashi–Maskawa quark mixing matrix, V ud , was superallowed nuclear β decays with an impressive 0.01% precision. This precision, apart from experimental data, relies on theoretical calculations in which nuclear structure–dependent effects and uncertainties play a prime role. This review is dedicated to a thorough reassessment of all ingredients that enter the extraction of the value of V ud from experimental data. We try to keep balance between historical retrospect and new developments, many of which occurred in just the past 5 years. They have not yet been reviewed in a complete manner, not least because new results are forthcoming. This review aims to fill this gap and offers an in-depth yet accessible summary of all recent developments.

ab initio methods↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Capacity Performance of a Stirling-Cycle Water-to-Water Heat Pump

The performance of a 10 kW (2.8 ton) heat pump has been modeled in preparation for evaluation in a controlled-atmosphere psychrometric facility. The heat pump uses an electrically driven Stirling engine with nitrogen as a working fluid. The appropriate standards for testing are ANSI/AHRI/ASHRAE ISO Standard 13256-2:1998 (RA 2012), Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps. The heating and cooling efficiency and capacity of the device has been modeled at different hot and cold sink temperatures spanning a wide range of possible operating conditions. The heat pump was designed for a seasonal efficiency energy ratio (SEER) of 22. The high efficiency of this product coupled with the use of nitrogen as a working fluid makes it an important tool for the decarbonization of residential, commercial, and industrial HVAC&R applications.

Kowalski, Steve↗

PMK 1000 cone-socket ventilator fittings force testing to ISO 5356-1:2015 Standard

This memo summarizes the results of verification tests on a cone-socket fitting to the ISO 5356-1:2015 standard, annexes B and F. The components were found to meet requirements holding 50N tensile force and more than 35 N-cm of torque for 10 seconds without separating at 35°C with a fresh socket. Humidity control was unavailable; consequently, humidity was significantly lower than the values in the ISO standard. Several repeat tests of the fitting with force, torque, and time excursions give us confidence that the fittings perform suitably to the ISO standard. Force overload tests suggest that the samples will disengage under tension at around 69 N, while torque overload tests under a force of 50 N will fail at 79 N-cm of torque. If repeated tests are performed on the same component, the socket can deform and lead to the connection failing the standard requirements. However, such failures only occur with repeated testing, and the gripping of such units can be modified so that they pass the standard. This observation demonstrates that socket gripping is responsible for those failures and would not be a problem in application.

42 ENGINEERING↗

Effects of knock intensity measurement technique and fuel chemical composition on the research octane number (RON) of FACE gasolines: Part 1 – Lambda and knock characterization

The Research and Motor Octane Number (RON and MON) rate the knock propensity of gasoline in the Cooperative Fuel Research (CFR) engine by comparing the knock intensity of sample fuels relative to that of primary reference fuels (PRF), a binary blend of iso-octane and n-heptane. Important differences exist between standard octane testing and automotive spark ignition (SI) engine knock testing including speed, load, air-to-fuel equivalence ratio (lambda), and knock characterization, which lead to a discrepancy between a fuel’s RON rating and its knock resistance characterized on an automotive SI engine based on knock-limited spark advance. This publication is the first of a set of three publications which modify operating parameters of the RON test method (ASTM D2699) to investigate the effects of these differences with automotive SI engine knock-limited spark advance testing. A fuel’s standard RON is evaluated at the lambda of the highest knock intensity, whereas automotive SI engines typically operate at stoichiometry. Here, we analyze the effects of a stoichiometric RON rating methodology. Additionally, the knock intensity response from the standard CFR knockmeter system is compared to a cylinder pressure oscillation-based knock intensity at several lambda settings. All experiments were performed with a set of seven Coordinating Research Council (CRC) Fuels for Advanced Combustion Engines (FACE) gasolines with approximately 95 RON. The fuel chemical composition impacted the lambda of the highest knock intensity, which resulted in fuel-specific offsets between the standard and stoichiometric RON ratings. The knock system comparison showed significant offsets between cylinder pressure-based and knockmeter-based knock intensity levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗