Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

(abstract) Atmospheric Transmission Model Through Autonomous Visibility Measurement

Performance of deep space optical communications is impacted by atmospheric outages. By monitoring known stellar objects with calibrated telescopes, atmospheric attenuation statistics can be recorded. This paper describes a program to develop an atmospheric transmission model for optical communications by making automous visibility measurements of known stellar objects from three locations in the southwestern US. The data will be correlated and infused with weather data to establish the atmospheric transmission model. This model will be sent in link margin analysis for optical communications channels. The statistics will be updated on a quarterly basis and calibrated using data taken over a long period of time. This calibration is expected to allow extrapolation to other ground-based locations through use of global weather databases.

attenuation model↗

ADVANCES IN CALIBRATION OF BUILDING ENERGY MODELS TO TIME SERIES DATA

Advanced building analytics and control applications, such as fault detection and diagnostics and model predictive control, benefit from building energy models calibrated to time series data. This paper recommends best practices for aligning EnergyPlus™ model time series output with measured building performance. These include the use of subcalibration procedures to fine-tune envelope, heat transfer, and mechanical system parameters; initialization of zone temperatures to match observed conditions at the beginning of each calibration period; and calculation of calibration metrics across multiple run periods using a new OpenStudio reporting measure.

Goldwasser, David↗

Advances in Calibration of Building Energy Models to Time Series Data: Preprint

Advanced building analytics and control applications such as fault detection and diagnostics and model predictive control benefit from building energy models calibrated to time series data. In this paper, we present best practices for aligning EnergyPlus (TM) model time series output with measured building performance. These include the use of subcalibration procedures to fine-tune envelope, heat transfer, and mechanical system parameters; initialization of zone temperatures to match observed conditions at the beginning of each calibration period; and calculation of calibration metrics across multiple run periods using a new OpenStudio reporting measure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration of the Rossi X-ray Timing Explorer Proportional Counter Array

We present the calibration and background model for the Proportional Counter Array (PCA) aboard the Rossi X-ray Timing Explorer (RXTE). The energy calibration is systematics limited below 10 keV with deviations from a power law fit to the Crab nebula plus pulsar loss than 1%. Unmodelled variations in the instrument background amount to less than 2% of the observed background below 10 keV and less than 1% between 10 and 20 keV. Individual photon arrival times are accurate to 4.4 microseconds at all times during the mission and to 2.5 microseconds after 29 April 1997. The peak pointing direction of the five collimators is known at few arcsecond precision.

Jahoda, Keith↗

Osmium coated diffraction grating in the Space Shuttle environment - Performance

Samples coated with osmium were flown on the early Shuttle test flights, and on the return of these samples, the osmium coating was found to have disappeared, evidently due to the oxidation of the material in the atomic oxygen atmosphere. An instrument flown on the Spacelab 1 mission comprised an array of five spectrometers covering the extreme ultraviolet (EUV) to near-IR wavelengths. The EUV spectrometer contained an osmium-coated reflective grating located fairly deep within the instruments. Here, results of an assessment of the reflectivity and stability of the osmium surface over the course of the ten-day mission are reported. It is concluded that the osmium reflective coating remained stable relative to the spectrometer coated with MgF2 over the course of the mission. In addition, the ratio of sensitivity of these two spectrometers did not change in any major way from the time of the laboratory calibration until the time of flight two years later. Any changes are within the 50-percent calibration uncertainty.

Torr, M. R.↗

New Strategies for Time Delay Estimation during System Calibration for UAV-Based GNSS/INS-Assisted Imaging Systems

The need for accurate 3D spatial information is growing rapidly in many of today’s key industries, such as precision agriculture, emergency management, infrastructure monitoring, and defense. Unmanned aerial vehicles (UAVs) equipped with global navigation satellite systems/inertial navigation systems (GNSS/INS) and consumer-grade digital imaging sensors are capable of providing accurate 3D spatial information at a relatively low cost. However, with the use of consumer-grade sensors, system calibration is critical for accurate 3D reconstruction. In this study, ‘consumer-grade’ refers to cameras that require system calibration by the user instead of by the manufacturer or other high-end laboratory settings, as well as relatively low-cost GNSS/INS units. In addition to classical spatial system calibration, many consumer-grade sensors also need temporal calibration for accurate 3D reconstruction. This study examines the accuracy impact of time delay in the synchronization between the GNSS/INS unit and cameras on-board UAV-based mapping systems. After reviewing existing strategies, this study presents two approaches (direct and indirect) to correct for time delay between GNSS/INS recorded event markers and actual time of image exposure. Our results show that both approaches are capable of handling and correcting this time delay, with the direct approach being more rigorous. When a time delay exists and the direct or indirect approach is applied, horizontal accuracy of 1–3 times the ground sampling distance (GSD) can be achieved without either the use of any ground control points (GCPs) or adjusting the original GNSS/INS trajectory information.

47 OTHER INSTRUMENTATION↗

A description of the lunar ranging station at McDonald Observatory.

The equipment of this station which has been in operation since the deployment of the first corner reflector by the Apollo 11 astronauts. The McDonald 2.7-m telescope is used for both transmission and reception of pulsed ruby laser light during three 45-minute daily laser runs about three weeks in a month. The present laser pulse width, timing system, calibration procedures, and signal levels are designed to achieve ranging with an accuracy to 1 nanosecond. The data rates obtained since September, 1970, are consistent with the scientific commitments of the lunar ranging program. Most of the over 200 acquisitions obtained have an accuracy to better than plus or minus 30 cm. Details of the telescope matching optics, guiding and timing equipment, and calibration procedures are discussed. Representative lunar range data are included.

Silverberg, E. C.↗

SU-E-I-22: Dependence On Calibration Phantom and Field Area of the Conversion Factor Used to Calculate Skin Dose During Neuro-Interventional Fluoroscopic Procedures

Purpose: To determine the appropriate calibration factor to use when calculating skin dose with our real-time dose-tracking system (DTS) during neuro-interventional fluoroscopic procedures by evaluating the difference in backscatter from different phantoms and as a function of entrance-skin field area. Methods: We developed a dose-tracking system to calculate and graphically display the cumulative skin-dose distribution in real time. To calibrate the DTS for neuro-interventional procedures, a phantom is needed that closely approximates the scattering properties of the head. We compared the x-ray backscatter from eight phantoms: 20-cm-thick solid water, 16-cm diameter water-filled container, 16-cm CTDI phantom, modified-ANSI head phantom, 20-cm-thick PMMA, Kyoto-Kagaku PBU- 50 head, Phantom-Labs SK-150 head, and RSD RS-240T head. The phantoms were placed on the patient table with the entrance surface at 15 cm tube-side from the isocenter of a Toshiba Infinix C-arm, and the entrance-skin exposure was measured with a calibrated 6-cc PTW ionization chamber. The measurement included primary radiation, backscatter from the phantom and forward scatter from the table and pad. The variation in entrance-skin exposure was also measured as a function of the skin-entrance area for a 30x30 cm by 20-cm-thick PMMA phantom and the SK-150 head phantom using four different added beam filters. Results: The entranceskin exposure values measured for eight different phantoms differed by up to 12%, while the ratio of entrance exposure of all phantoms relative to solid water showed less than 3% variation with kVp. The change in entrance-skin exposure with entrance-skin area was found to differ for the SK-150 head compared to the 20-cm PMMA phantom and the variation with field area was dependent on the added beam filtration. Conclusion: To accurately calculate skin dose for neuro-interventional procedures with the DTS, the phantom for calibration should be carefully chosen since different phantoms can contribute different backscatter for identical exposure parameters. Research supported in part by Toshiba Medical Systems and NIH Grants R43FD0158401, R44FD0158402 and R01EB002873.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pulsar Movement Animation and its Corresponding Signal Visualization for Timing Source

The global positioning system, widely used for synchronization in energy systems, faces vulnerabilities, while Pulsars—natural cosmic clocks—offer long-term stability as potential backup timing sources. Existing research lacks sufficient exploration of Pulsar signal animation under astrophysical factors, limiting practical applications. This study establishes a mathematical model based on the rotation dynamics of dual-beam Pulsars and implements dynamic signal visualization through MATLAB. The model dynamically illustrates the relative motion between Pulsar beams and observers via timeline calculations, beam intensity modeling, and rotation matrix derivation. A case study on the millisecond Pulsar J1939+2134 reveals that observer angles influence signal peak timing, while beam widths determine signal duration, highlighting the critical role of parameter calibration for timing accuracy. Open-source code and animation results are publicly shared, providing tools for interdisciplinary research. This study validates the feasibility of Pulsar-based timing in energy systems, offering new insights to enhance synchronization robustness.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

The Demonstration of a Light Extinction Tomography System at the NASA Glenn Research Center's Icing Research Tunnel

A prototype light extinction tomography system has been developed for acquiring real-time in-situ icing cloud uniformity and density measurements in the NASA Glenn Research Center's Icing Research Tunnel (IRT). These measurements are currently obtained through periodic manual calibrations of the IRT. These calibrations are time consuming and assume that cloud uniformity and density does not greatly vary between the periodic calibrations. It is envisioned that the new light extinction tomography system will provide the means to make these measurements in-situ in real-time and minimize the need for these manual calibrations. This new system uses the principle of light extinction tomography to measure the spray density and distribution in the test section. The prototype system was installed and successfully demonstrated in the Icing Research Tunnel in early 2018. Data sets were acquired for several standard spray and simulated fault conditions to assess system capability and sensitivity. This paper will describe the prototype light extinction system, the theory behind it, and the results of the demonstration test that was conducted in the IRT.

Test Facility↗

The Demonstration of a Light Extinction Tomography System at the NASA Glenn Research Center's Icing Research Tunnel

A prototype light extinction tomography system has been developed for acquiring real-time in-situ icing cloud uniformity and density measurements in the NASA Glenn Research Center's Icing Research Tunnel (IRT). These measurements are currently obtained through periodic manual calibrations of the IRT. These calibrations are time consuming and assume that cloud uniformity and density does not greatly vary between the periodic calibrations. It is envisioned that the new light extinction tomography system will provide the means to make these measurements in-situ in real-time and minimize the need for these manual calibrations. This new system uses the principle of light extinction tomography to measure the spray density and distribution in the test section. The prototype system was installed and successfully demonstrated in the Icing Research Tunnel in early 2018. Data sets were acquired for several standard spray and simulated fault conditions to assess system capability and sensitivity. This paper will describe the prototype light extinction system, the theory behind it, and the results of the demonstration test that was conducted in the IRT.

Tomography↗

SU-E-T-575: Novel Quality Assurance Procedure for the Small Animal Radiation Research Platform Using Commercial OSLDs

Purpose: To support radiobiological research with the Xstrahl small animal radiation research platform (SARRP) by developing a simple and effective method using commercially available optically stimulated luminescent dosimeters (OSLDs) that ensures dose output consistency. Methods: The SARRP output is calibrated according to the vendor standards and TG-61 protocol utilizing an ADCL calibrated ion chamber and electrometer at 2 cm depth of solid water. A cross calibration is performed by replacing the ion chamber with five OSLDs at the 2 cm depth. The OSLDs are irradiated to 500 cGy with 220 keV at 13 mA (78s delivery time) with a copper filter for an uncollimated 17×17 cm{sup 2} aperture. Instead of the absolute dose, the total amount of raw counts are collected from the OSLD reader and used for analysis. This constancy procedure was performed two more times over the course of three weeks with two OLSDs for validity. Results: The average reading for all OSLDs is 494939 with a 1-sigma standard deviation of the 5.8%. With an acceptable dose output range of ±10%, the OSLD readings have a counts range of [445445, 544433]. Conclusion: This method of using nanoDot™ OSLDs to perform output constancy checks for the SARRP ensures the output of the device is within 10% from the time of calibration and is convenient as well as time efficient. Because this, the frequency of output checks can be increased, which can improve the output stability for research with this device. The output trend of the SARRP will continue to be monitored in the future to establish a timeline for constancy checks and recalibration.

60 APPLIED LIFE SCIENCES↗

Microradiometers Reveal Ocean Health, Climate Change

When NASA researcher Stanford Hooker is in the field, he pays close attention to color. For Hooker, being in the field means being at sea. On one such research trip to the frigid waters of the Arctic, with a Coast Guard icebreaker looming nearby and the snow-crusted ice shelf a few feet away, Hooker leaned over the edge of his small boat and lowered a tethered device into the bright turquoise water, a new product devised by a NASA partner and enabled by a promising technology for oceanographers and atmospheric scientists alike. Color is a function of light. Pure water is clear, but the variation in color observed during a visit to the beach or a flight along a coastline depends on the water s depth and the constituents in it, how far down the light penetrates and how it is absorbed and scattered by dissolved and suspended material. Hooker cares about ocean color because of what it can reveal about the health of the ocean, and in turn, the health of our planet. "The main thing we are interested in is the productivity of the water," Hooker says. The seawater contains phytoplankton, microscopic plants, which are the food base for the ocean s ecosystems. Changes in the water s properties, whether due to natural seasonal effects or human influence, can lead to problems for delicate ecosystems such as coral reefs. Ocean color can inform researchers about the quantities and distribution of phytoplankton and other materials, providing clues as to how the world ocean is changing. NASA s Coastal Zone Color Scanner, launched in 1978, was the first ocean color instrument flown on a spacecraft. Since then, the Agency s ocean color research capabilities have become increasingly sophisticated with the launch of the SeaWiFS instrument in 1997 and the twin MODIS instruments carried into orbit on NASA s Terra (1999) and Aqua (2002) satellites. The technology provides sweeping, global information on ocean color on a scale unattainable by any other means. One issue that arises from satellite observation, however, is that the instruments must be continuously calibrated over time to maintain the quality of the data they gather from orbit. To validate and calibrate the satellites, researchers must also gather data at sea level.

Source record↗

Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Digital Calibration of TR Modules for Real-time Digital Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures such as that of the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). These new instrument concepts require new methods for calibrating the multiple channels, which must be combined on-board, in real-time. The calibration of current state-of-the-art Electronically Steered Arrays typically involves pre-flight TR (Transmit/Receive) module characterization over temperature, and in-flight correction based on temperature, which ignores the effects of element aging and drifts unrelated to temperature. We are developing new methods for digitally calibrating digital beamforming arrays to reduce development time, risk and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop Digital Calibration, thus tracking systematic changes regardless of temperature. The benefit of this effort is that it would enable a new class of lightweight radar architecture, Digital Beamforming with SweepSAR, providing significantly larger swath coverage than conventional SAR architectures for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined on-board, in real-time.

Real-time digital beamforming↗

Convective heating measurement by means of an infrared camera

The development of rapid and accurate wind tunnel techniques to measure convective heating distributions in complex reentry configurations is discussed. Major emphasis was put on the infrared camera technique. Its essence is the measurement of infrared emission from the surface of a wind tunnel model as a function of time. Prior calibration of the infrared camera relates the emission to the surface temperature of the model. The time history of the surface temperature can then be related to the heating rate by standard techniques. The output of the camera is an electrical signal that is tape-recorded in analog form, then digitized and processed by computer, so that automated and relatively rapid data reduction can be accomplished. In addition, the camera produces real-time visual displays of the infrared emission as pictures on an oscilloscope screen. These pictures give immediate indications of hot and cool spots on the model.

Compton, D. L.↗

Calibration of the Visible and Near-Infrared Channels of the Advanced Very High Resolution Radiometer (AVHRR) After Launch

The relative degradation in time of the visible(channel 1: approx.0.58-0.6 microns) and near-infrared(channel 2: approx. O.72-1.1 microns) channels of the Advanced Very High Resolution Radiometer(AVHRR), onboard the NOAA Polar-orbiting Operational Environmental Satellites(POES), has been determined, using the southeastern Libyan desert(21-23 deg N latitude; 28- 29 deg E longitude) as a time-invariant calibration target. A statistical procedure was used on the reflectance data for the two channels from the B3 data of the International Satellite Cloud Climatology Project(ISCCP) to obtain the degradation rates for the AVERRs on NOAA-7, -9, and -11 spacecraft. The degradation rates per year for channels 1 and 2 are respectively: 3.6% and 4.3%(NOAA-7); 5.9% and 3.5%(NOAA-9); and 1.2% and 2.0%(NOAA-11). The use of the degradation rates thus determined, in conjunction with 'absolute' calibrations obtained from congruent aircraft and satellite measurements, in the development of correction algorithms is illustrated with the AVHRR on the NOAA-9 spacecraft.

Rao, C. R. Nagaraja↗