Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Projection Chambers (TPC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Using Neural Networks for Low Energy Reconstruction and Neutron Identification in the MicroBooNE LArTPC

Identifying and reconstructing final-state neutrons from neutrino interactions in Liquid Argon Time Projection Chambers (LArTPCs) will enhance future oscillation measurements by recovering missing energy and improving neutrino interaction channel identification. However, neutrons are challenging to reconstruct as the majority leave only small, isolated charge signatures known as blips. Here we present initial efforts to identify neutrons in the MicroBooNE LArTPC with low energy protons from neutron-argon inelastic interactions that present as blips below the traditional tracking threshold in the TPC. Unlike for tracks, there is no algorithmic method to determine direction for blips since they span only a few wires. Therefore, we developed and trained a Recurrent Neural Network (RNN) to reconstruct the directionality of proton-induced blips, allowing us to separate signal from background by selecting blips that point back to the neutrino vertex. The model achieves a preliminary average angular resolution of 17 degrees when tested on a simulated sample of protons over 6 MeV in kinetic energy. This novel tool will enhance neutron detection in LArTPCs and expand a broad range of other low-energy physics searches such as for solar and supernova neutrinos.

Silva, Liani Isabel [Unlisted, US]↗

Study and improvement of the trigger system in ICARUS

In recent years, intriguing experimental neutrino anomalies have emerged. If confirmed, they could hint at the presence of additional sterile neutrino states playing in neutrino mixing. The Short-Baseline Neutrino project at Fermilab aims to delve into these anomalies, utilizing three Liquid Argon Time Projection Chamber detectors along the Booster Neutrino Beam. The SBND detector serves as nearby instruments, while MicroBooNE and ICARUS function as far detectors and also explore the NuMI beam off-axis. A relevant aspect in the functioning of all SBN detectors is the trigger system, that determines which interactions are recorded. In particular, in ICARUS, it relies on the synchronization of prompt signals from scintillation light within the LAr-TPC, detected by a system of Photo-Multiplier Tubes, with the proton beam’s spill extraction. The existing majority-based logic of the trigger system could potentially be enhanced through adder boards that sum analog signals from PMTs in groups of 15. This sum-based triggering might aid in identifying events near TPC walls, where light is abundant but captured by only a few PMTs, potentially bypassing the majority condition. Comprehensive tests have been performed to characterize these adder boards.

43 PARTICLE ACCELERATORS↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing CRT and Pandora Tagged Tracks in ICARUS

The ICARUS Liquid Argon Time Projection Chamber (LArTPC) is used to investigate short-baseline neutrino oscillations and the possible existence of sterile neutrinos. To aid in identifying and rejecting cosmic ray backgrounds, the system is outfitted with external Cosmic Ray Taggers (CRTs). The CRT is able to measure more tracks and at a wider range of angles, useful in further detailing future calibrations. This project compared the most probable values (MPVs) of charge deposition between CRT tagged and TPC tagged tracks. The Y-Z maps of charge scale for both datasets show a strong correlation, not just in their overall structure, but also in how they reflect known detector effects. Both reconstruction paths showed similar structures in their charge distribution, such as less effective wire section or mechanical support, confirming that CRT-tagged tracks, despite being external, respond to the same calibration landscape as Pandora tracks, validating previous Pandora reconstructions and values. Overall, the analysis supports the idea that the CRT tags are a useful addition to ICARUS calibration efforts. Their broad angular range and independence from Pandora reconstruction make them a helpful secondary tool and a potential asset in extending calibration across the detector volume.

Thayer, Abigail [Colorado State U.] (ORCID:0009000↗

Comparing CRT and Pandora Tagged Tracks in ICARUS

The ICARUS Liquid Argon Time Projection Chamber (LArTPC) is used to investigate short-baseline neutrino oscillations and the possible existence of sterile neutrinos. To aid in identifying and rejecting cosmic ray backgrounds, the system is outfitted with external Cosmic Ray Taggers (CRTs). The CRT is able to measure more tracks and at a wider range of angles, useful in further detailing future calibrations. This project compared the most probable values (MPVs) of charge deposition between CRT tagged and TPC tagged tracks. The Y-Z maps of charge scale for both datasets show a strong correlation, not just in their overall structure, but also in how they reflect known detector effects. Both reconstruction paths showed similar structures in their charge distribution, such as less effective wire section or mechanical support, confirming that CRT-tagged tracks, despite being external, respond to the same calibration landscape as Pandora tracks, validating previous Pandora reconstructions and values. Overall, the analysis supports the idea that the CRT tags are a useful addition to ICARUS calibration efforts. Their broad angular range and independence from Pandora reconstruction make them a helpful secondary tool and a potential asset in extending calibration across the detector volume.

Thayer, Abbie [Fermilab; Colorado State U.]↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

New MeV-Scale Capabilities in Large Neutrino LArTPCs Using Ambient Radiogenic and Cosmogenic Activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing and interpreting MeV-scale energy depositions present in their data. We use data from MicroBooNE, an 85 tonnes LArTPC exposed to Fermilab neutrino beams from 2015 until 2021, to demonstrate new calorimetric and particle discrimination capabilities for isolated $\sim \mathrm{O}(1 \mathrm{MeV})$ energy depositions referred to as blips. We observe a concentration of low energy ( $<3$ MeV ) blips around fiberglass mechanical support struts along the TPC edges with energy spectrum features consistent with the Compton edge of 2.614 MeV Tl-208 decay gamma rays. These features are used to verify proper calibration of electron energy scales in MicroBooNE's data to few percent precision and to measure the specific activity of Tl-208 in the fiberglass composing these struts. Cosmogenicallyproduced blips above 3 MeV in reconstructed energy are used to showcase the ability of large LArTPCs to distinguish between low-energy proton and electron energy depositions.

Andrade Aldana, Diego Armando↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Liquid Argon Time Projection Chamber Trigger Development with MicroBooNE

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) neutrino detector at Fermilab that has been operating since 2015. It aims to perform v-Ar cross-section measurements, explore the low-energy excess reported by the MiniBooNE experiment and perform a combined search for sterile neutrino oscillations as part of three LArTPCs that make up the Short Baseline Neutrino (SBN) Program at Fermilab. Since MicroBooNE is currently in an R&D phase, it offers a unique opportunity for the implementation and testing of TPC-based triggers as R&D towards the Deep Underground Neutrino Experiment (DUNE). One of the technical challenges of DUNE that we aim to address with this study is that of efficient self-triggering of a LArTPC utilizing TPC signal information. This capability will enable searches for rare processes in DUNE, such as neutrino interactions from a potential galactic supernova burst. This talk will describe the MicroBooNE TPC readout system and ongoing R&D efforts to develop and demonstrate TPC-based triggering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid andgas time projection chambers (TPCs) is the delivery and distributionof high voltages into and around the detector. Such experimentsrequire of order tens of kilovolts to enable electron drift overmeter-scale distances. This paper describes the design andoperation of the cathode feedthrough and high voltage distributionthrough the field cage of the NEXT-100 experiment, an undergroundTPC that will search for neutrinoless double beta decay0νββ. The feedthrough has been demonstrated to holdpressures up to 20 bar and sustain voltages as high as -65 kV.The TPC is operating stably at its design high voltages. The systemhas been realized within the constraints of a stringent radiopuritybudget and is now being used to execute a suite of sensitive doublebeta decay analyses.

Adams, C. [Argonne]↗

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are essential for detecting muons and neutrinos by capturing electrons released during particle collisions, which drift toward wire planes under an electric field and induce currents measured to reconstruct particle paths. However, LArTPCs face challenges from effects such as electron-ion recombination, electron diffusion, and electron attenuation, complicating data simulation. The Short Baseline Neutrino (SNB) detector aims to measure neutrinos before oscillation occurs. To bridge the gap between simulation and actual data, we propose modifying the amplitude and width of signals on the TPC wires, addressing uncertainties by adjusting signal characteristics to better match observed data. A Gaussian fit to current waveforms produces hits with associated charge and width, and by comparing data and simulated values, discrepancies highlight areas where the model fails. Initial results indicate the current modification algorithm may increase divergence between simulation and data, necessitating further refinement. A discovered bug in the WireModMakeHist_plug.cpp file, which incorrectly computed simulation and data ratios, underscores the need for precise algorithm adjustments. Future work involves correcting code errors, fine-tuning the model, and conducting multiple simulation runs to enhance statistical confidence and reduce uncertainties, ultimately aiming for accurate LArTPC operation and reliable neutrino detection.

Mkrtchyan, Ka'ren↗

Method of creating structure for particle detection in time projection chambers and photodetectors

Time projection chambers are useful for high energy particle physics, nuclear physics, and astronomy. To enhance the particle detection efficiency and performance of the projection chambers functional bilayer thin film coatings based on the atomic layer deposition method are utilized. Coating material selection is based on Auger neutralization process ion induced electron emission from metallic surfaces (e.g., Mo or W) combined with a high secondary electron emission coefficient. Application of high secondary electron emission materials (e.g., MgO and CaF2) enhances the multiplication of these emitted electrons from ion induction processes. Therefore, using suitable bilayer coatings the overall TPC signal detection efficiency can be increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Almost medium-free measurement of the Hoyle state direct-decay component with a TPC

The structure of the Hoyle state, a highly α -clustered state at 7.65 MeV in 12 C, has long been the subject of debate. Understanding if the system comprises of three weakly interacting α particles in the 0s orbital, known as an α-condensate state, is possible by studying the decay branches of the Hoyle state. The direct decay of the Hoyle state into three α particles, rather than through the 8 Be ground state, can be identified by studying the energy partition of the three α particles arising from the decay. This paper provides details on the breakup mechanism of the Hoyle stating using a new experimental technique. Method: By using β-delayed charged-particle spectroscopy of 12 N using the Texas active target time-projection chamber, a high-sensitivity measurement of the direct 3α decay ratio can be performed without contributions from pileup events. A Bayesian approach to understanding the contribution of the direct components via a likelihood function shows that the direct component is <0.043% at the 95% confidence level. This value is in agreement with several other studies, and, here, we can demonstrate that a small nonsequential component with a decay fraction of about 10 –4 is most likely. Here, the measurement of the non-sequential component of the Hoyle state decay is performed in an almost medium-free reaction for the first time. The derived upper limit is in agreement with previous studies and demonstrates sensitivity to the absolute branching ratio. Further experimental studies would need to be combined with robust microscopic theoretical understanding of the decay dynamics to provide additional insight into the idea of the Hoyle state as an α condensate.

6 ≤ A ≤ 19↗

Signatures of clustering accessible with a Time Projection Chamber: TexAT

Many experimental observables in clustering require high-sensitivity, almost background-free measurements. The use of Time Projection Chambers (TPCs) over the past 15 years have demonstrated their capability as a step change in the accessibility of many of these observables, as well as the possibility to study clustering via new techniques. A summary of the difficulties and pitfalls of determining the type of clustering from observables is briefly discussed, with a focus on α-condensation and the possibility of an additional (Efimov) 0 + state in 12 C, below the Hoyle state. The expansion of the technique used to tackle this challenge to study 3α + p clustering in 13 N is also discussed, highlighting the exciting opportunities TPCs provide to study clustering inaccessible by conventional means. Finally, an overview of the recent and upcoming advances in TPC technology is given as well as listing additional future challenges that are needed to be overcome, in the context of discussing the next-generation upgrade to the existing TexAT TPC, known as TeBAT (TExas Birmingham Active Target).

Bishop, Jack↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A pion-argon cross section measurement in the ProtoDUNE-SP experiment with cosmogenic muon

Neutrinos are tiny mysterious fundamental particles with small cross sections. Through neutrino physics, scientists across the world are trying to answer many intriguing questions about nature such as the dominance of matter over antimatter, CP violation in the lepton sector, number of supernovas in the early universe, etc. Detection of neutrinos requires massive particle detectors and intense neutrino beam owing to their small cross section. Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment that is planned to start taking data beginning in 2026. DUNE will consist of 4 massive detectors, the first of which will be using single-phase liquid argon time projection chamber (LArTPC) technology. The ProtoDUNE-SP experiment is a prototype of the DUNE built at the CERN neutrino platform and uses the same detector technology that will be used in DUNE first module. The ProtoDUNE-SP experiment collected months of test beam and cosmic ray data beginning in September 2018. It was built to provide a testbed for the installation of detector parts for DUNE, showing long-term stability of the detector, understanding detector response for different test beam particles (including protons, pions, electrons, kaons, muons), and measurement of hadron-argon cross sections. When a particle passes through LArTPC electron-ion pairs are produced. To reconstruct the position and energy of a particle passing through the medium knowledge of ionization electron drift velocity is essential. The electron drift velocity is distorted by an excess positive charge built up in the detector, known as space charge. This study discusses a novel technique for measuring the ionization electron drift velocity using cosmic-ray muons. The technique uses tracks that travel the entire drift distance of the TPC for drift velocity determination. Secondly, the study discusses a method for converting the charge deposited into energy. The method is carried out in two step s. In th e first step detector response for energetic cosmic ray muons crossing the entire the TPC is used to make the charge deposition uniform throughout the TPC, and in the second step stopping cosmic-ray muons are used for determining the energy scale. Finally, the study discusses a pion-argon cross section measurement based on reweighting of Monte Carlo simulations using J. Calcutt's Geant4Reweight framework. Neutrinos cannot be directly detected; they are identified based on the interaction products. Pions are a common interaction product in a neutrino interaction. For precise modeling of neutrino event generators, it is essential to understand the pion-argon interaction. Pion-argon cross section measurement serves as an important input for neutrino interaction models. The results of the pion-argon total reaction cross section using the Geant4 reweighting technique are found to be in good agreement with Geant4 predictions. The many studies carried out in the ProtoDUNE-SP experi ment wil l be useful for current and future neutrino experiments using LArTPC technology including ICARUS, MicroBooNE, DUNE

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗