Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time of Flight (ToF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

How nitrogen and oxygen shape SRF cavity performance

Nitrogen and oxygen-based surface treatments have revolutionized the performance of superconducting radiofrequency (SRF) cavities, enabling them to reach higher gradients and lower losses. However, the exact mechanisms by which these treatments improve cavity performance remain largely unknown. This work provides new insights into the role of nitrogen and oxygen in SRF cavity performance by using time-of-flight secondary ion mass spectrometry (TOF-SIMS) to precisely quantify the concentrations and depth profiles of these impurities within niobium cutouts. We correlate these impurity profiles with detailed cavity performance measurements, including surface resistance and quality factor, and compare our findings with predictions from BCS theory. The results demonstrate that while both nitrogen and oxygen enhance performance, ten times more oxygen is required to achieve the same reduction in BCS resistance as interstitial nitrogen. We present a potential model in which the observed variation arises from nitrogen's greater effectiveness in trapping hydrogen, thus reducing the formation of niobium hydrides and enhancing superconducting gap.

Hu, Hannah [Chicago U.]↗

Molecular imaging of plant-microbe interactions on the Brachypodium seed surface

Plant growth-promoting rhizobacteria (PGPR) play a crucial role in biological control and pathogenic defense on and with-in plant tissues, however the mechanism(s) by which plants associate with PGPR to elicit such beneficial effects needs further study. Here, we present high mass resolution time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of Brachypodium distachyon (Brachypodium) seeds with and without exposure to two model PGPR, i.e., Gram-negative Pseudomonas fluorescens SBW25::GFP (P.) and Gram-positive Arthrobacter chlorophenolicus A6::GFP (A.). Delayed image extraction was used to image PGPB-treated seed sections to reveal morphological changes. ToF-SIMS spectral compari-son, principal component analysis (PCA), and two-dimensional (2D) imaging show that the selected PGPR have different effects on the host seed surface, resulting in changes in chemical composition and morphology. Metabolite prod-ucts and biomarkers, such as flavonoids, phenolic com-pounds, fatty acids, and indole-3-acetic acid (IAA), were ob-served on the PGPR-treated seed surfaces. These compounds had different distributions on the Brachypodium seed surface for the two PGPR, indicating that the different bacteria elicited distinct responses from the host. Our results illustrate that ToF-SIMS is an effective tool to study plant-microbe interac-tions and to provide insightful information with submicrome-ter lateral resolution of the chemical distributions associated with morphological features, potentially offering a new way to study the mechanisms underlying beneficial roles of PGPR.

PGPR, Brachypodium distachyon, ToF-SIMS, metabolit↗

Liquid ToF-SIMS revealing the oil, water, and surfactant interface evolution

Bilge water from ships is regarded as a major pollutant in the marine environment. Bilge water exists in a stable oil-in-water (O/W) emulsion form. However, little is known about the O/W liquid–liquid (l–l) interface. Traditional bulk characterization approaches are not capable of capturing the chemical changes at the O/W l–l interface. Although surfactants are deemed essential in droplet formation, their roles in bilge water stabilization have not been fully revealed. We have utilized novel in situ chemical imaging tools including in situ scanning electron microscopy (SEM) and in situ time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the evolving O/W interface using a NAVY bilge model for the first time. The droplet size distribution (DSD) does not change significantly without the addition of X-100 surfactants under static or rocking conditions. Both the oil components and the water clusters are shown to evolve over time at the O/W droplet interface by in situ liquid SIMS imaging. Of particular interest to droplet stabilization, the contribution of surfactants to the aged bilge droplets becomes more significant as the droplet size increases. The higher mass surfactant component does not appear on the droplet surface immediately while many lower mass surfactants are solvated inside the droplet. We have provided the first three-dimensional images of the evolving O/W interface and demonstrated that in situ surface chemical mapping is powerful enough to reveal the complex and dynamic l–l interface in the liquid state. Our observational insights suggest that surfactants are important in mediating droplet growth and facilitating effective separation of bilge water emulsion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic Heterogeneity Imaged in a Uranium Fuel Pellet with Extreme Ultraviolet Laser Ablation and Ionization Time-of-Flight Mass Spectrometry

We use extreme ultraviolet laser ablation and ionization time-of-flight mass spectrometry (EUV TOF) to map uranium isotopic heterogeneity at the nanoscale (=100 nm). Using low-enriched uranium fuel pellets that were made by blending two isotopically distinct feedstocks, we show that EUV TOF can map the 235U/238U content in 100 nm-sized pixels. The two-dimensional (2D) isotope maps reveal U ratio variations in sub-microscale to =1 µm areas of the pellet that had not been fully exposed by microscale or bulk mass spectrometry analyses. Compared to the ratio distribution measured in a homogeneous U reference material, the ratios in the enriched pellet follow a ~3× wider distribution. These results indicate U heterogeneity in the fuel pellet from incomplete blending of the different source materials. EUV TOF results agree well with those obtained on the same enriched pellets by nanoscale secondary ionization mass spectrometry (NanoSIMS), which reveals a comparable U isotope ratio distribution at the same spatial scale. EUV TOF’s ability to assess and map isotopic heterogeneity at the nanoscale makes it a promising tool in fields such as nuclear forensics, geochemistry, and biology that could benefit from uncovering sub-microscale sources of chemical modifications.

Rush, Lydia A.↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OASIS: Organics Analyzer for Sampling Icy Surfaces

Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.

Getty, S. A.↗

Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and modeling results to describe the performance of a field emission electron gun as employed in the Volatile Analysis by Pyrolysis of Regolith (VAPoR) TOF-MS prototype.

Southard, Adrian E.↗

Characterization of a Carbon Nanotube Field Emission Electron Gun for the VAPoR Miniaturized Pyrolysis-Time-of-Flight Mass Spectrometer

We are developing the VAPoR (Volatile Analysis by Pyrolysis of Regolith) instrument towards studying soil composition, volatiles, and trapped noble gases in the polar regions of the Moon. VAPOR will ingest a soil sample and conduct analysis by pyrolysis and time-of-flight mass spectrometry (ToF-MS). Here, we describe miniaturization efforts within this development, including a carbon nanotube (CNT) field emission electron gun that is under consideration for use as the electron impact ionization source for the ToF-MS.

Getty, Stephanie↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma–time of flight–mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the 107 Ag/ 109 Ag particles (n = 132,630) over the course of the measurements was determined to be 1.0788 ± 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector–ICP-MS determination.

36 MATERIALS SCIENCE↗

ToF-SIMS Analysis of Chemical Composition of Atmospheric Aerosols in Beijing

Atmospheric aerosols collected from each season in urban Beijing have been studied using time-of-flight secondary ion mass spectrometry (ToF-SIMS). The chemical composition of atmospheric aerosol particles during various atmospheric pollution levels were analyzed and distinguished by principal component analysis (PCA). The differences and sources of the components of the aerosol particles were explored. The results showed that the fine particulate matter from heavily polluted days mainly consists of inorganic salts and organic compounds, such as hydrocarbons, nitrogen- or sulfur-containing hydrocarbons, and their oxides. Samples collected from clean days in the four seasons were also analyzed. Only the samples collected in spring showed a significant difference from the other three seasons. We concluded that the main source of pollution in the Beijing urban area was fossil fuel combustion from motor vehicles.

ToF-SIMS, principal component analysis↗

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Role of SnO2 Processing on Ionic Distribution in Double-Cation-Double Halide Perovskites

Moving toward a future of efficient, accessible, and less carbon-reliant energy devices has been at the forefront of energy research innovations for the past 30 years. Metal-halide perovskite (MHP) thin films have gained significant attention due to their flexibility of device applications and tunable capabilities for improving power conversion efficiency. Serving as a gateway to optimize device performance, consideration must be given to chemical synthesis processing techniques. Therefore, how does common substrate processing techniques influence the behavior of MHP phenomena such as ion migration and strain? Here, we demonstrate how a hybrid approach of chemical bath deposition (CBD) and nanoparticle SnO2 substrate processing significantly improves the performance of (FAPbI3)0.97(MAPbBr3)0.03 by reducing micro-strain in the SnO2 lattice, allowing distribution of K+ from K-Cl treatment of substrates to passivate defects formed at the interface and produce higher current in light and dark environments. X-ray diffraction reveals differences in lattice strain behavior with respect to SnO2 substrate processing methods. Through use of conductive atomic force microscopy (c-AFM), conductivity is measured spatially with MHP morphology, showing higher generation of current in both light and dark conditions for films with hybrid processing. Additionally, time-of-flight secondary ionization mass spectrometry (ToF-SIMS) observed the distribution of K+ at the perovskite/SnO2 interface, indicating K+ passivation of defects to improve the power conversion efficiency (PCE) and device stability. We show how understanding the role of ion distribution at the SnO2 and perovskite interface can help reduce the creating of defects and promote a more efficient MHP device.

conductive atomic force microscopy↗

Atmospheric Ion Composition, SGP, April-May 2023

These files contain select ion count rates measured by an atmospheric pressure interface time-of-flight mass spectrometer (APi-ToF) at the Atmospheric Radiation Measurement Southern Great Plains site from April 28, 2023 to May 31, 2023. Files are in ICARTT format. The APi-ToF measures the chemical composition of naturally charged ions using mass spectrometry. Due to the nature of the measurements, time-series data are non-quantitative. This dataset contains time-series information for the ions that are typically the most intense ions observed.

54 ENVIRONMENTAL SCIENCES↗

Correlative Surface Imaging Reveals Chemical Signatures for Bacterial Hotspots on Plant Roots

The rhizosphere is arguably the most complex microbial habitat on earth, comprising an integrated network of plant roots, soil and a highly diverse microbial community (the rhizosphere microbiome)1. Understanding, predicting and controlling plant-microbe interactions in the rhizosphere will allow us to harness the plant microbiome as a means to increase or restore plant ecosystem productivity, improve plant responses to a wide range of environmental perturbations, and mitigate effects of climate change by designing ecosystems for long-term soil carbon storage1. To this end, it is imperative to develop new molecular approaches with high spatial resolution to capture interactions at the plant-microbe, microbe-microbe, and plant-plant interfaces. In this work, we designed an imaging sample holder that allows integrated surface imaging tools to map the same locations of a plant root-microbe interface with submicron lateral resolutions, providing novel in vivo analysis of root-microbe interactions. Specifically, confocal fluorescence microscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), and scanning electron microscope (SEM) were used for the first time for correlative imaging of the Brachypodium distachyon root and its interaction with Pseudomonas SW25, a typical plant growth-promoting soil bacterium. Imaging data suggest that the root surface is inhomogeneous and that the interaction between Pseudomonas and Brachypodium roots was confined to only few spots along the sampled root segments and that the bacterial attachment spots were enriched in Na- and S-related and high-mass organic species. We conclude that attachment of the Pseudomonas cells to the root surface is outcompeted by strong root-soil mineral interactions but facilitated by formation of extracellular polymeric substances (EPS).

Plant root, Plant growth-promoting bacteria, soil,↗

CO 2 in Ionene–Ionic Liquid Composite Membranes

Abstract Ionene – ionic liquid (IL) composites are promising materials for CO 2 separation, yet a molecular‐level understanding of their structure and its impact on CO 2 speciation, solubility, rotation, and diffusivity remains unclear. Herein, using multimodal nuclear magnetic resonance (NMR), time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS), atomic force microscopy (AFM), and molecular dynamics (MD) simulations, we reveal that the composites contain IL‐rich domains extending across hundreds of nanometres within the ionene matrix, and these bicontinuous domains span the entire membrane depth. CO 2 also absorbs into the ionene matrix, with the distribution between two CO 2 species varying with temperature and time. The rotational correlation times of these two species are on the timescale of 0.1 and 1 ns, respectively. As IL content increases, the ionic domains expand, resulting in higher CO 2 solubility due to enhanced molecular dynamics and increased free volume in both ionene backbones and IL‐rich regions. Although CO 2 diffusion in the membranes is an order of magnitude slower than in bulk IL, the activation energy for CO 2 diffusion remains comparable. Ionene‐IL composites represent a promising platform for designing CO 2 separation membranes, offering enhanced CO 2 diffusion and selectivity through IL‐rich domains, and increased CO 2 solubility and mechanical integrity from the ionene matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Congruence of Clusters Defined By Whole Genome Sequencing and MALDI-TOF for Bacteria Isolated From Cleanrooms

Introduction: Oligotrophic conditions can render cleanrooms inhospitable to microbes. Despite these constraints, fungi and bacteria are frequently isolated from surfaces in astromaterials cleanrooms at the Johnson Space Center. Bacillus species are of particular concern because endospores belonging to this genus are resilient and can affect astromaterials. Current monitoring programs rely on 16S rRNA sequencing and the VITEK2 Compact system. These methods have limited power to resolve Bacillus species. Matrix-assisted laser desorption - time of flight mass spectrometry (MALDI-TOF MS), provides a rapid, low cost, method of identifying bacterial isolates and has a higher resolution than 16S rRNA sequencing, particularly for Bacillus species; however, few studies have compared this method to the industry gold standard, whole genome sequencing (WGS). Methods: Based on 16S rRNA classification, we selected 14 isolates for analysis with MALDI-TOF and WGS. Mass spectra were generated with MALDI-TOF MS and processed with custom scripts to identify clusters of closely related isolates and calculate a matrix of pairwise cosine similarity scores. Hybrid Illumina and Nanopore sequencing were used to generate draft genomes. Pairwise similarity scores were calculated from these genomes based on the average amino acid identity (AAI) predicted from single copy core genes. Congruence of clustering between these methods, was assessed by calculating adjusted Rand and Wallace coefficients. Results: Clusters of species generated from MALDI-TOF MS showed good agreement of phylotypes generated with WGS. Pairs of strains that were > 94% similar to each other in terms of predicted amino acid sequences consistently showed cosine similarities of mass spectra > 0.65 and, of the 9 clusters identified with WGS, 8 were identical with MALDI-TOF. This corresponds to an adjusted Rand index of 0.95 and a 95% confidence interval of 0.80 – 1.00 for adjusted Wallace coefficients. The only discordance was for a pair of isolates that were classified as Paenibacillus species. This pair showed relatively high similarity (0.84) in terms of MALDI-TOF MS but only 85% similarity in terms of AAI. Conclusion: This study shows that MALDI-TOF and WGS exhibit a similar ability to delineate Bacillus species isolated from cleanrooms and taxonomic units described by these two methods are consistent with one another. Since MALDI-TOF MS is low in cost and high in throughput, this approach appears to be an ideal option for routine microbial monitoring and identifying Bacillus species.

Farnaz Mazhari↗