Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total variance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Magnetic field directional discontinuities. I - Minimum variance errors

The paper deals with a statistical analysis of the errors associated with a minimum variance analysis of directional discontinuities by use of an idealized model of these discontinuities and various simulations, and also by an examination of actual Mariner 10 interplanetary magnetic field data. An empirical expression is derived for the magnitude of the error in an estimated discontinuity normal component, relative to the total field across the directional discontinuity. The analysis was performed primarily to aid in differentiating between interplanetary tangential and rotational discontinuities observed by Mariner 10.

Lepping, R. P.↗

Mapping biomass for a northern forest ecosystem using multi-frequency SAR data

Image processing methods for mapping standing biomass for a forest in Maine, using NASA/JPL airborne synthetic aperture radar (AIRSAR) polarimeter data, are presented. By examining the dependence of backscattering on standing biomass, it is determined that the ratio of HV backscattering from a longer wavelength (P- or L-band) to a shorter wavelength (C) is a good combination for mapping total biomass. This ratio enhances the correlation of the image signature to the standing biomass and compensates for a major part of the variations in backscattering attributed to radar incidence angle. The image processing methods used include image calibration, ratioing, filtering, and segmentation. The image segmentation algorithm uses both means and variances of the image, and it is combined with the image filtering process. Preliminary assessment of the resultant biomass maps suggests that this is a promising method.

Ranson, K. J.↗

Position and shape of the Venus bow shock - Pioneer Venus Orbiter observations

Magnetometer data from the Pioneer Venus Orbiter is used to examine the position and shape of this planet's bow shock. Utilizing crossings identified on 86 occasions during the first 65 orbits a mean shock surface is defined for sun-Venus-satellite angles of 60-110 deg. Both the shock shape and variance in location are found to be very similar to the terrestrial case for the range in SVS angle considered. However, while the spread in shock positions at the earth is due predominantly to the magnetopause location varying in response to solar wind dynamic pressure, ionopause altitude variations can have little effect on total obstacle radius. Thus, the Cytherean shock is sometimes observed much closer to or farther from the planet than previously predicted by gasdynamic theory applied to the deflection of flow about a blunt body which acts neither as source nor sink for any portion of the flow.

Slavin, J. A.↗

New Observations of Subarcsecond Photospheric Bright Points

We have used an interference filter centered at 4305 A within the bandhead of the CH radical (the 'G band') and real-time image selection at the Swedish Vacuum Solar Telescope on La Palma to produce very high contrast images of subarcsecond photospheric bright points at all locations on the solar disk. During the 6 day period of 15-20 Sept. 1993 we observed active region NOAA 7581 from its appearance on the East limb to a near-disk-center position on 20 Sept. A total of 1804 bright points were selected for analysis from the disk center image using feature extraction image processing techniques. The measured FWHM distribution of the bright points in the image is lognormal with a modal value of 220 km (0.30 sec) and an average value of 250 km (0.35 sec). The smallest measured bright point diameter is 120 km (0.17 sec) and the largest is 600 km (O.69 sec). Approximately 60% of the measured bright points are circular (eccentricity approx. 1.0), the average eccentricity is 1.5, and the maximum eccentricity corresponding to filigree in the image is 6.5. The peak contrast of the measured bright points is normally distributed. The contrast distribution variance is much greater than the measurement accuracy, indicating a large spread in intrinsic bright-point contrast. When referenced to an averaged 'quiet-Sun' area in the image, the modal contrast is 29% and the maximum value is 75%; when referenced to an average intergranular lane brightness in the image, the distribution has a modal value of 61% and a maximum of 119%. The bin-averaged contrast of G-band bright points is constant across the entire measured size range. The measured area of the bright points, corrected for pixelation and selection effects, covers about 1.8% of the total image area. Large pores and micropores occupy an additional 2% of the image area, implying a total area fraction of magnetic proxy features in the image of 3.8%. We discuss the implications of this area fraction measurement in the context of previously published measurements which show that typical active region plage has a magnetic filling factor on the order of 10% or greater. The results suggest that in the active region analyzed here, less than 50% of the small-scale magnetic flux tubes are demarcated by visible proxies such as bright points or pores.

Berger, T. E.↗

Retrievals of Cloud Droplet Size from the RSP Data: Validation Using in Situ Measurements

We present comparisons of cloud droplet size distributions retrieved from the Research Scanning Polarimeter (RSP) data with correlative in situ measurements made during the North Atlantic Aerosols and Marine Ecosystems Study (NAAMES). This field experiment was based at St. Johns airport, Newfoundland, Canada with the latest deployment in May - June 2016. RSP was onboard the NASA C-130 aircraft together with an array of in situ and other remote sensing instrumentation. The RSP is an along-track scanner measuring polarized and total reflectances in9 spectral channels. Its unique high angular resolution allows for characterization of liquid water droplet size using the rainbow structure observed in the polarized reflectances in the scattering angle range between 135 and 165 degrees. A parametric fitting algorithm applied to the polarized reflectances provides retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, Rainbow Fourier Transform (RFT), which allows us to retrieve the droplet size distribution (DSD) itself. The latter is important in the case of clouds with complex structure, which results in multi-modal DSDs. During NAAMES the aircraft performed a number of flight patterns specifically designed for comparison of remote sensing retrievals and in situ measurements. These patterns consisted of two flight segments above the same straight ground track. One of these segments was flown above clouds allowing for remote sensing measurements, while the other was at the cloud top where cloud droplets were sampled. We compare the DSDs retrieved from the RSP data with in situ measurements made by the Cloud Droplet Probe (CDP). The comparisons show generally good agreement with deviations explainable by the position of the aircraft within cloud and by presence of additional cloud layers in RSP view that do not contribute to the in situ DSDs. In the latter case the distributions retrieved from the RSP data were consistent with the multi-layer cloud structures observed in the correlative High Spectral Resolution Lidar (HSRL) profiles. The comparison results provide a rare validation of polarimetric droplet size retrieval techniques, which can be used for analysis of satellite data on global scale.

cloud droplets↗

Spatial analysis of storm depths from an Arizona raingage network

Eight years of summer rainstorm observations are analyzed by a dense network of 93 raingages operated by the U.S. Department of Agriculture, Agricultural Research Service, in the 150 km Walnut Gulch experimental catchment near Tucson, Arizona. Storms are defined by the total depths collected at each raingage during the noon-to-noon period for which there was depth recorded at any of the gages. For each of the resulting 428 storm days, the gage depths are interpolated onto a dense grid and the resulting random field analyzed to obtain moments, isohyetal plots, spatial correlation function, variance function, and the spatial distribution of storm depth.

Fennessey, N. M.↗

New Observations of Subarcsecond Photospheric Bright Points

We have used an interference filter centered at 4305 A within the bandhead of the CH radical (the 'G band') and real-time image selection at the Swedish Vacuum Solar Telescope on La Palma to produce very high contrast images of subarcsecond photospheric bright points at all locations on the solar disk. During the 6 day period of 1993 September 15-20 we observed active region NOAA 7581 from its appearance on the East limb to a near-disk-center position on September 20. A total of 1804 bright points were selected for analysis from the disk center image using feature extraction image processing techniques. The measured Full Width at Half Maximum (FWHM) distribution of the bright points in the image is lognormal with a modal value of 220 km (0 sec .30) and an average value of 250 km (0 sec .35). The smallest measured bright point diameter is 120 km (0 sec .17) and the largest is 600 km (O sec .69). Approximately 60% of the measured bright points are circular (eccentricity approx. 1.0), the average eccentricity is 1.5, and the maximum eccentricity corresponding to filigree in the image is 6.5. The peak contrast of the measured bright points is normally distributed. The contrast distribution variance is much greater than the measurement accuracy, indicating a large spread in intrinsic bright-point contrast. When referenced to an averaged 'quiet-Sun' area in the image, the modal contrast is 29% and the maximum value is 75%; when referenced to an average intergranular lane brightness in the image, the distribution has a modal value of 61% and a maximum of 119%. The bin-averaged contrast of G-band bright points is constant across the entire measured size range. The measured area of the bright points, corrected for pixelation and selection effects, covers about 1.8% of the total image area. Large pores and micropores occupy an additional 2% of the image area, implying a total area fraction of magnetic proxy features in the image of 3.8%. We discuss the implications of this area fraction measurement in the context of previously published measurements which show that typical active region plage has a magnetic filling factor on the order of 10% or greater. The results suggest that in the active region analyzed here, less than 50% of the small-scale magnetic flux tubes are demarcated by visible proxies such as bright points or pores.

Berger, T. E.↗

The experimental determination of atmospheric absorption from aircraft acoustic flight tests

A method for determining atmospheric absorption coefficients from acoustic flight test data is presented. Measurements from five series of acoustic flight tests were included in the study. The number of individual flights totaled 24: six Boeing 707 flights performed in May 1969 in connection with the turbofan nacelle modification program, eight flights from Boeing tests conducted during the same period, and 10 flights of the Boeing 747 airplane. The effects of errors in acoustic, meteorological, and aircraft performance and position measurements are discussed. Tabular data of the estimated sample variance of the data for each test are given for source directivity angles from 75 deg to 120 deg and each 1/3-octave frequency band. Graphic comparisons are made of absorption coefficients derived from ARP 866, using atmospheric profile data, with absorption coefficients determined by the experimental method described in the report.

Miller, R. L.↗

Effects of Hypergravity and Adrenalectomy on Total Body Bone Mineral Content in Male Rats

The effects of 14 days of increased gravitational load, and the absence of adrenal stress hormones on total body bone mineral content (BMC) were examined in male Sprague-Dawley rats. Centrifugation at 2 Gs (2G) was used to increase the gravitational load, and bilateral adrenalectomy (ADX) was used to eliminate the production of adrenal stress hormones. Stationary groups at 1 G (1G) and sham operated (SHAM) animals served as controls. Thirty rats (n=6 or 8) made up the four experimental groups (1G SHAM, 1G ADX, 2G SHAM and 2G ADX). BMC was assessed by dual energy X-ray absorptiometry (DXA) and activity was determined through biotelemetry. Body mass and food intake were also measured. Multi-factorial analysis of variance (MANCOVA) and Newman Keuls post hoc tests were used to analyze significant effects (p less than 0.05) for the primary variables. Results indicated that BMC decreased significantly with increased G for both the SHAM and ADX groups. The BMC for the 1 G ADX group was also significantly lower than the 1G SHAM group, however the 2G SHAM and ADX groups were not significantly different. There was a significant decrease in body mass with increased G and there was no ADX effect on body mass. When BMC was normalized for body mass changes, there were no significant group differences. Activity level decreased with body mass, and food intake data showed there was significant hypophagia during the first few days of centrifugation. These results suggest that the decrease in total body BMC seen with hypergravity may be based to a large extent on the differences in body mass induced by the 2 G load.

Girten, Beverly↗

Analysis of the lettuce data from the variable pressure growth chamber at NASA Johnson Space Center: A three-stage nested design model

A model of three-stage nested experimental design was applied to analyze the lettuce data obtained from the variable pressure growth chamber test bed at NASA-Johnson Space Center. From the results of an application of the analysis of variance and covariance on the data set, it was noted that all of the (uncontrollable) factors, Side, Zone, Height and (controllable) PAR (photosynthetically active radiation), had nonhomogeneous effects on the dry weight of the edible biomass of lettuce per pot. Incidentally, the variations accountable to the (uncontrollable) factorial heterogeneities are merely 9 percent and 17 percent of the total variation for both the first and second crop test, respectively. After adjusting for the PAR as a covariate in the no-intercept model, the accountable variations to all the four factors are 94 percent and 92 percent for the first and the second crop test, respectively. With the use of a no-intercept simple linear regression model, the accountable variations to the factor PAR are 92 percent and 90 percent for the first and the second crop test, respectively. Evidently, the (controllable) factor PAR is the dominating one.

Lee, Tze-San↗

Nonlinear probabilistic finite element models of laminated composite shells

A probabilistic finite element analysis procedure for laminated composite shells has been developed. A total Lagrangian finite element formulation, employing a degenerated 3-D laminated composite shell with the full Green-Lagrange strains and first-order shear deformable kinematics, forms the modeling foundation. The first-order second-moment technique for probabilistic finite element analysis of random fields is employed and results are presented in the form of mean and variance of the structural response. The effects of material nonlinearity are included through the use of a rate-independent anisotropic plasticity formulation with the macroscopic point of view. Both ply-level and micromechanics-level random variables can be selected, the latter by means of the Aboudi micromechanics model. A number of sample problems are solved to verify the accuracy of the procedures developed and to quantify the variability of certain material type/structure combinations. Experimental data is compared in many cases, and the Monte Carlo simulation method is used to check the probabilistic results. In general, the procedure is quite effective in modeling the mean and variance response of the linear and nonlinear behavior of laminated composite shells.

Engelstad, S. P.↗

Probabilistic nonlinear finite element analysis of composite structures

A probabilistic finite element analysis procedure for laminated composite shells is developed. A total Lagrangian finite element formulation, employing a degenerated three-dimensional laminated composite shell element with the full Green-Lagrange strains and first-order shear deformable kinematics, is used. The first-order second-moment technique for probabilistic finite element analysis of random fields is employed, and results are presented in the form of mean and variance of the structural response. Reliability calculations are made by using the first-order reliability method combined with sensitivity derivatives from the finite element analysis. Both ply-level and micromechanics-level random variables are incorporated, the latter by means of the Aboudi micromechanics model. Two sample problems are solved to verify the accuracy of the procedures developed and to quantify the variability of certain material type/structure combinations. In general, the procedure is quite effective in determining the response statistics and reliability for linear and geometric nonlinear behavior of laminated composite shells.

Engelstad, S. P.↗

Tropical Rainfall Variability on Interannual-to-Interdecadal/Longer-Time Scales Derived from the GPCP Monthly Product

Global and large regional rainfall variations and possible long-term changes are examined using the 26-year (1979-2004) GPCP monthly dataset (Adler et al., 2003). Our emphasis is to discriminate among variations due to ENSO, volcanic events, and possible long-term climate changes in the tropics. Although the global linear change of precipitation in the data set is near zero during the time period, an increase in tropical rainfall is noted, with a weaker decrease over northern hemisphere middle latitudes. Focusing on the tropics (25degS-25degN), the data set indicates an upward trend (0.06 mm/day/decade) and a downward trend (-0.02 mm/day/decade) over tropical ocean and land, respectively. This corresponds to an about 4.9% increase (ocean) and 1.6% decrease (land) during the entire 26-year time period. Techniques are applied to isolate and quantify variations due to ENSO and two major volcanic eruptions (El Chichon, March 1982; Pinatubo, June 1991) in order to examine longer time-scale changes. The ENSO events generally do not impact the tropical total rainfall, but, of course, induce significant anomalies with opposite signs over tropical land and ocean. The impact of the two volcanic eruptions is estimated to be about a 5% reduction in tropical rainfall over both land and ocean. A modified data set (with ENSO and volcano effects removed) retains the same approximate linear change slopes, but with reduced variance, thereby increasing the confidence levels associated with the long-term rainfall changes in the tropics 2

Gu, Guojun↗

Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise

This design constitutes a self-resetting (gain quenching), room-temperature operational semiconductor single-photon-sensitive detector that is sensitive to telecommunications optical wavelengths and is scalable to large areas (millimeter diameter) with high bandwidth and efficiencies. The device can detect single photons at a 1,550-nm wavelength at a gain of 1 x 10(exp 6). Unlike conventional single photon avalanche detectors (SPADs), where gain is an extremely sensitive function to the bias voltage, the multiplication gain of this device is stable at 1 x 10(exp 6) over a wide range of bias from 30.2 to 30.9 V. Here, the multiplication gain is defined as the total number of charge carriers contained in one output pulse that is triggered by the absorption of a single photon. The statistics of magnitude of output signals also shows that the device has a very narrow pulse height distribution, which demonstrates a greatly suppressed gain fluctuation. From the histograms of both pulse height and pulse charge, the equivalent gain variance (excess noise) is between 1.001 and 1.007 at a gain of 1 x 10(exp 6). With these advantages, the device holds promise to function as a PMT-like photon counter at a 1,550- nm wavelength. The epitaxial layer structure of the device allows photons to be absorbed in the InGaAs layer, generating electron/hole (e-h) pairs. Driven by an electrical field in InGaAs, electrons are collected at the anode while holes reach the multiplication region (InAlAs p-i-n structure) and trigger the avalanche process. As a result, a large number of e-h pairs are created, and the holes move toward the cathode. Holes created by the avalanche process gain large kinetic energy through the electric field, and are considered hot. These hot holes are cooled as they travel across a p -InAlAs low field region, and are eventually blocked by energy barriers formed by the InGaAsP/ InAlAs heterojunctions. The composition of the InGaAsP alloy was chosen to have an 80 meV valance band offset with InAlAs, which is high enough to hinder the transport of the already cooled holes. Being stopped by the energy barrier, holes are accumulated at the junctions to shield the electric field, resulting in a decrease of the electric field in the multiplication region. Because the impact ionization rate is extremely sensitive to the magnitude of the electric field, the field-screening effect drastically reduces the impact ionization rate and quenches the output signals. After the avalanche pulse signal is self-quenched, the accumulated holes at the InGaAsP/ InAlAs interface escape the energy barrier through thermal excitation and tunneling and finally leave the device. The device is thus reset and ready for subsequent photon detection. This recovery time is controlled by the height of the energy barrier and the hole-cooling rate.

Zhao, Kai↗

120 MB/S and 240 MB/S bit synchronizer-signal conditioners for NASA high data rate applications

Two bit synchronizer-signal conditioners (BSSC) developed for NASA high data rate applications such as earth resources monitoring are described. One BSSC is centered at 120 MB/s and the other at 240 Mb/s. These subsystems are featured out of the total hardware developed because the BSSC is such a key subsystem in determining overall system statistical performance. These units represent an evolution of high data rate BSSC's available at low data rates. Numerous inputs/outputs, control functions, indicators, plus the ability to minimize the effects of various signal perturbations are provided. Examples of allowed perturbations are input level variations, bit rate variance static and dynamic, baseline, transition density, bandlimiting, etc., as well as noise. Emphasis in the past has been primarily concerned only with noise.

Gray, J. S.↗

Effects of Cage Type and NASA Rodent Food Bar in Male Sprague-Dawley Rats

Early prototype caging for the rodent Advanced Animal Habitat (P-AAH) for the International Space Station (ISS) is currently being tested. In this five week study, effects of the wire-bottom P-AAH cages and specialized NASA rodent food bars (FB) were compared to standard vivarium cages (VIV) with corn-cob, litter-filled bottoms, and standard Purina rat chow (CH). Ninety-six male Sprague-Dawley rats were divided into four treatment groups (24 rats/treatment): Group 1) VIV+CH, Group 2) P-AAH+CH, Group 3) VIV+FB, and Group 4) P-AAH+FB. Each VIV and P-AAH cage housed three and six rats, respectively. After five weeks of treatment rats were weighed, euthanized, and blood samples were collected. Weights of liver (LIV), kidney (KID), brain (BRN), epididymal fat (EPI), and perirenal fat (PERI) were also measured. Statistical analysis to compare differences between groups was performed by standard analysis of variance procedures (ANOVA) with a significance level of pLO.05. Results indicated P-AAH housed rats had significantly lower body weights (BW), LIV weights, and LIV/BW than VIV housed rats. FB fed rats had significantly lower blood urea nitrogen (BUN) levels and LIV/BW than CH fed rats. In addition, FB fed rats had significantly higher cholesterol (CHOL) levels, EPI/BW, PERI/BW, and total fat (EPI+PERI)/BW than CH fed rats. The P-AAH+FB group had significantly lower EPI, BRN, and total fat than VIV+FB rats. VIV+FB rats had significantly higher BRN, EPI, PERI, and total fat than VIV+CH rats. Triglycerides (TG), KID, KID/BW, and BRN/BW were not significantly different among treatment groups. These findings provide valuable information regarding cage design and food bar suitability for long-term use on the ISS.

Lau, Angela↗

Evaluation of portable air samplers for monitoring airborne culturable bacteria

Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

NASA Center JSC↗

Use of the VAS for analysis of a prethunderstorm environment

The information content of the VAS radiances can be converted to meteorological parameters useful for analyzing a severe weather environment. The method by which the VAS variances are converted to vertical profiles of temperature, dewpoints, and equivalent potential temperature involves a basic regression technique using the most local radiosonde data available for establishing a correlation matrix. The results indicate that mesoscale features apparent within images of the radiances can be converted to usable temperature and moisture fields using regression when surface temperature and dewpoint observations are included within the total data base. In addition, results indicate that surface data are very important for better defining lower tropospheric structure that the VAS radiances alone cannot properly resolve. Analyses of these retrievals distinctly show mesoscale structure in the temperature and moisture fields derived with VAS radiances collected every 3 hours, and 0000 GMT. The retrievals capture the moisture structure. More important, convective instability is clearly detected immediately before the onset of convection. The results indicate that the VAS is capable of providing valuable mesoscale information suitable for analyzing a preconvective environment that is generally clear.

Uccellini, L. W.↗