At least 199 records · Page 11

A study of the local pressure field in turbulent shear flow and its relation to aerodynamic noise generation

Work during the period of this report has been in three areas: (1) pressure transducer error analysis, (2) fluctuating velocity and pressure measurements in the NASA Lewis 6-inch diameter quiet jet facility, and (3) measurement analysis. A theory was developed and experimentally verified to quantify the pressure transducer velocity interference error. The theory and supporting experimental evidence show that the errors are a function of the velocity field's turbulent structure. It is shown that near the mixing layer center the errors are negligible. Turbulent velocity and pressure measurements were made in the NASA Lewis quiet jet facility. Some preliminary results are included.

Jones, B. G.↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Electronically-Scanned Pressure Sensors

Sensors not pneumatically switched. Electronic pressure-transducer scanning system constructed in modular form. Pressure transducer modules and analog to digital converter module small enough to fit within cavities of average-sized wind-tunnel models. All switching done electronically. Temperature controlled environment maintained within sensor modules so accuracy maintained while ambient temperature varies.

Coe, C. F.↗

Fluctuating pressure measurements on the fan blades of a turbofan engine during ground and flight tests

As part of a program to investigate fan noise generated by a turbofan engine, miniature pressure transducers were used to measure the fluctuating pressures on the surface of a fan blade on the JT15D engine. Tests were conducted on the ground, with tunnel and in flight. Using narrowband spectra analysis and signal enhancement techniques, comparisons for these various test conditions are presented. Results on the blade pressures are also presented from a flight test in which 41 rods were placed in front of the fan face to excite a known spinning mode in the duct. Results showed that with care, ground tests can be conducted in which the pressure loading on the blades are similar to those in flight. Comparison of pressure transducers on the blade surface also showed that a single transducer would provide much of the information available from this type of measurement.

Schoenster, J. A.↗

High frequency dynamic pressure calibration technique

A high frequency dynamic calibration technique for pressure transducers has been developed using a siren pressure generator (SPG). The SPG is an inlet-area-modulated device generating oscillating waveforms with dynamic pressure amplitudes up to 58.6 kPa (8.5 psi) in a frequency range of 1 to 10 kHz. A description of the generator, its operating characteristics and instrumentation used for pressure amplitude and frequency measurements is given. Waveform oscillographs and spectral analysis of the pressure transducers' output signals are presented.

Davis, P. A.↗

Measuring Absolute Oxygen Pressure

Sensor determines absolute pressure of oxygen without reference pressure source. Absolute oxygen pressure transducer with control circuit enables measurement without reference pressure. Transducer, two part device, combines solid electrolyte membranes sensor with diffusional orifice. Device adapted for direct control of oxygen pressure in combustion mixtures.

Richter, R.↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 4 - Raw Data

Sequence 4: Static Pressure Calibration (P) This test sequence used a downwind, teetered turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 30° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. A static pitot probe was installed on a boom 2.3 m upwind of the nacelle at hub height and connected to the reference side of the Mensor digital differential pressure transducer through the pneumatic rotary coupling. This provided the reference pressure for all blade-mounted pressure transducers, as opposed to the NASA atmospheric pressure reference that was used for all other test sequences. This simulates the pressure system connections used in field measurements where the static pressure was unknown.

17 WIND ENERGY↗

Groundwater and surface water head from 2019 to 2022 at the Tims Branch in Savannah River Site (SRS), South Carolina.

This dataset contains groundwater and surface water head measurements for investigating hydro-biogeochemical processes in Tims Branch at the Savannah River Site, SC. Water levels were monitored using pressure transducers installed in surface water gauges and piezometers across three subsites in Tims Branch, identified as Wfloc, Snon (Snon1 and Snon2), and Sfloc. A barometric pressure logger was deployed in piezometers to correct pressure transducers from atmospheric pressure. Manual water level measurements were taken to calibrate transducer data. The dataset consists of at least paired groundwater and surface water head time series for each subsite, provided as individual CSV files. These data support analyses of surface-groundwater interactions, hydrologic controls on redox processes, and broader synthesis of wetland hydrology at the Savannah River Site.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere-hour nickel-cadmium spacecraft cells for the tracking data relay satellite system

Five cells provided by NASA's Goddard Space Flight Center were evaluated at room temperature and pressure (25 C plus or minus 2 C) with discharges at the 2 hour rate. Measurements of the cell containers following test, indicated an average increase of .006 inches at the plate thickness. Average end of charge voltages and pressures, and capacity output in ampere hours were determined. Three cells exceeded the voltage requirements of 1.52 volts during both c/10 charges at 20 C. All cells exceeded the voltage requirement of 1.52 volts during the 0 C overcharge test, although their end charges were below 1.50 volts. The pressure requirement of 65 psia was exceeded by both pressure transducer cells during c/10 charges at 25 C and 20 C and also during the 0 C overcharge test. The cells with pressure transducers reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test, and exhibited a pressure decay of 2 psia during the last 30 minutes of the 1 hour open circuit stand. Average capacity was 51.3 ampere hours.

Harkness, J. D.↗

Low Differential Pressure Generator

A method and apparatus for evaluating low differential pressure transducers includes a pressure generator in the form of a piston-cylinder assembly having a piston that may be manually positioned precisely within the cylinder to change the volume and thus the pressure at respective sides of the piston. At one side of the piston the cylinder communicates with a first chamber and at the other side of the piston the cylinder communicates with a second chamber, the first and second chambers being formed within a common tank by a partition wall. The chambers each communicate with the transducer to be evaluated and a standard pre-calibrated transducer the transducers being connected fluidly in parallel so that a pressure differential between air in the two chambers resulting from movement of the piston within the cylinder is communicated to both the transducer to be evaluated and the standard transducer, and the outputs of the transducers is observed and recorded.

Stout, Stephen J.↗

The influence of sweep on the aerodynamic loading of an oscillating NACA 0012 airfoil. Volume 1: Technical report

Aerodynamic experiments were performed on an oscillating NACA 0012 airfoil utilizing a tunnel-spanning wing in both unswept and 30 degree swept configurations. The airfoil was tested in steady state and in oscillatory pitch about the quarter chord. The unsteady aerodynamic loading was measured using pressure transducers along the chord. Numerical integrations of the unsteady pressure transducer responses were used to compute the normal force, chord force, and moment components of the induced loading. The effects of sweep on the induced aerodynamic load response was examined. For the range of parameters tested, it was found that sweeping the airfoil tends to delay the onset of dynamic stall. Sweeping was also found to reduce the magnitude of the unsteady load variation about the mean response. It was determined that at mean incidence angles greater than 9 degrees, sweep tends to reduce the stability margin of the NACA 0012 airfoil; however, for all cases tested, the airfoil was found to be stable in pure pitch. Turbulent eddies were found to convect downstream above the upper surface and generate forward-moving acoustic waves at the trailing edge which move upstream along the lower surface.

St.hilaire, A. O.↗

SUMS experiment flight results on STS-35

Calibrated pressure measurements for species with mass to charge ratios up to 50 amu/e(-) were obtained from the Shuttle Upper Atmosphere Mass Spectrometer (SUMS) experiment during reentry on the STS-35 mission. Data were collected from 180 km, when the signal rose above the background, to about 87 km, when the SUMS system automatically closed the gas inlet value. However, data above 115 km was contaminated from a source of gas emanating from pressure transducers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data is compared with the mass spectrometer total pressure with excellent agreement. The free-stream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. standard atmosphere model, exhibits the wave-like nature seen on previous flights using accelerometry. In addition, selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump. An analysis of the spectra data from this event is presented to show that no significant permanent changes occurred which affected the data interpretation at lower altitudes. Further, the localized chemistry from the individual species during the onset of aerodynamic heating is examined to the extent possible for a closed source system, such as SUMS. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions with the carbon panels of the Orbiter and absorbed oxygen on the system tubing.

Blanchard, Robert C.↗

Experimental Investigation of Vapor Formation in Liquid CO2 Flow Through a Converging-Diverging Nozzle

Carbon dioxide is an attractive working fluid for many cycles, including for pumped thermal energy storage (PTES). A challenge with some proposed sCO2 PTES cycles is the operation of sCO2 machinery outside the typical bounds of experience, with local phase change from the liquid state being particularly unknown. Presently, there is insufficient data in the literature regarding multiphase CO2 to adequately design a multiphase-tolerant turbine, so generation of foundational data is required. This experimental study investigates the flow characteristics of sub-sonic liquid CO2 undergoing expansion and phase change in a converging-diverging nozzle. The nozzle is instrumented to measure static pressure, unsteady pressure, temperature, and density. The static pressure transducers are located at 27 axial locations to accurately characterize the pressure profile in the nozzle. High-accuracy RTDs are located at the entrance and exit of the nozzle, and three dynamic pressure transducers are strategically located to capture any unsteady phenomena. During testing, values of mass flow and nozzle inlet pressure are swept to vary the pressure drop and fluid properties. The measured total pressure drop in the nozzle is compared to a homogenous model and the Lockhart-Martinelli correlation method, with the latter predicting loss quite closely. The resulting data set is valuable for validating multiphase numerical models in a simple geometry before implementation of these models in turbomachinery design.

25 ENERGY STORAGE↗

The Entry Descent and Landing Instrumentation (MEDLI2) Suite for the Mars 2020 Mission

This presentation will discuss the current state of each of the main measurements systems for MEDLI2. The first system is a network of pressure transducers, the Mars Entry Atmospheric Data System (MEADS). Improving upon MEDLI, separate MEDLI2 pressure transducers span the measurement range suitable for both hypersonic and supersonic flows. The MEADS will also measure pressure on the backshell of the vehicle to better characterize the contribution of backshell pressure on the overall forces and moments on the entry probe. The second system is the thermal instrumentation, or Mars Instrumented Sensor Plugs. This system includes a network of high-temperature thermocouples embedded in the thermal protection system across the heatshield and backshell. The MISP also includes two types of sensors for directly measuring incident heatflux on the backshell of the vehicle. In addition, a radiometer is included on the backshell to measure radiative heating. The presentation will also cover the current state of the MEDLI2 hardware, expected environments that will be measured, and data analysis techniques being developed to infer vehicle entry performance from both the MISP and MEADS sensor systems.

White, Todd↗

Investigation of space shuttle vehicle 140C configuration orbiter (model 16-0) wheel well pressure loads in the Rockwell International 7.75 x 11 foot wind tunnel (OA143)

Experimental aerodynamic investigations were conducted on a sting mounted .0405-scale representation of the 140C outer mold line space shuttle orbiter configuration in the Rockwell International 7.75 x 11.00 foot low speed wind tunnel. The primary test objectives were to define the orbiter wheel well pressure loading and its effects on landing gear thermal insulation and to investigate the pressure environment experienced by both the horizontal flight nose probe and air vent door probes. Steady state and dynamic pressure values were recorded in the orbiter nose gear well, left main landing gear well, horizontal flight nose probe, and both left and right air vent door probe. All steady state pressure levels were measured by Statham differential pressure transducers while dynamic pressure levels were recorded by Kulite high frequency response pressure sensors.

Mennell, R. C.↗