Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two phase flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

"Hypothetical" Heavy Particles Dynamics in LES of Turbulent Dispersed Two-Phase Channel Flow

The extensive experimental study of dispersed two-phase turbulent flow in a vertical channel has been performed in Eaton's research group in the Mechanical Engineering Department at Stanford University. In Wang & Squires (1996), this study motivated the validation of LES approach with Lagrangian tracking of round particles governed by drag forces. While the computed velocity of the flow have been predicted relatively well, the computed particle velocity differed strongly from the measured one. Using Monte Carlo simulation of inter-particle collisions, the computation of Yamamoto et al. (2001) was specifically performed to model Eaton's experiment. The results of Yamamoto et al. (2001) improved the particle velocity distribution. At the same time, Vance & Squires (2002) mentioned that the stochastic simualtion of inter-particle collisions is too expensive, requiring significantly more CPU resources than one needs for the gas flow computation. Therefore, the need comes to account for the inter-particle collisions in a simpler and still effective way. To present such a model in the framework of LES/Lagrangian particle approach, and to compare the calculated results with Eaton's measurement and modeling of Yamamoto is the main objective of the present paper.

Gorokhovski, M.↗

Metastable sound speed in gas-liquid mixtures

A new method of calculating speed of sound for two-phase flow is presented. The new equation assumes no phase change during the propagation of an acoustic disturbance and assumes that only the total entropy of the mixture remains constant during the process. The new equation predicts single-phase values for the speed of sound in the limit of all gas or all liquid and agrees with available two-phase, air-water sound speed data. Other expressions used in the two-phase flow literature for calculating two-phase, metastable sound speed are reviewed and discussed. Comparisons are made between the new expression and several of the previous expressions -- most notably a triply isentropic equation as used, a triply isentropic equation as used, among others, by Karplus and by Wallis. Appropriate differences are pointed out and a thermodynamic criterion is derived which must be satisfied in order for the triply isentropic expression to be thermodynamically consistent. This criterion is not satisfied for the cases examined, which included two-phase nitrogen, air-water, two-phase parahydrogen, and steam-water. Consequently, the new equation derived is found to be superior to the other equations reviewed.

Bursik, J. W.↗

Microgravity Fluid Separation Physics: Experimental and Analytical Results

Effective, low power, two-phase separation systems are vital for the cost-effective study and utilization of two-phase flow systems and flow physics of two-phase flows. The study of microgravity flows have the potential to reveal significant insight into the controlling mechanisms for the behavior of flows in both normal and reduced gravity environments. The microgravity environment results in a reduction in gravity induced buoyancy forces acting on the discrete phases. Thus, surface tension, viscous, and inertial forces exert an increased influence on the behavior of the flow as demonstrated by the axisymmetric flow patterns. Several space technology and operations groups have studied the flow behavior in reduced gravity since gas-liquid flows are encountered in several systems such as cabin humidity control, wastewater treatment, thermal management, and Rankine power systems.

Shoemaker, J. Michael↗

Microgravity two-phase fluid flow pattern modeling

When gas and liquid mixtures flow in a pipe, the distribution of the two phases may take many forms. A flow pattern, or flow regime, is the characteristic spatial distribution of the phases of flow in a pipe. Because heat transfer and pressure drop are dependent on the characteristic distribution of phases, it is necessary to describe flow patterns in an appropriate manner so that a hydrodynamic or heat transfer theory applicable to that can be chosen. A theoretical two phase flow regime transition map under a microgravity environment was developed on physical concepts. These transitions use four basic flow patterns: dispersed flow, slug flow, stratified flow, and annular flow. The forces considered are body force, surface tension force, inertial force, friction, and the force from eddy turbulent fluctuation. Three dimensionless parameters were developed. Because these transition boundaries were developed based on physical concepts, they should be applicable to flow regimes occurring in various design conditions. Because the flow pattern data from KC-135 experiments are insufficient to verify these theoretical transition lines completely, an adiabatic experiment for flow regime analysis is recommended.

Lee, Doojeong↗

Numerical Modeling Of Two-Phase, Reactive Flows

Capabilities of several computational schemes combined and enhanced. Advanced Rocket Injector-Combustor Code is computer program for numerical simulation of two-phase flows of chemically reacting or nonreacting components. Applied to sprays of fuel in injectors and combustors, flows in heat exchangers, evaporators, and mass-diffusion systems; and two-dimensional or axisymmetric flows containing liquid or solid suspensions. Used in research for development and verification of various physical models.

Liang, Pak-Yan↗

Cryogenic and Simulated Fuel Jet Breakup in Argon, Helium and Nitrogen Gas Flows

Two-phase flow atomization of liquid nitrogen jets was experimentally investigated. They were co-axially injected into high-velocity gas flows of helium, nitrogen and argon, respectively, and atomized internally inside a two-fluid fuel nozzle. Cryogenic sprays with relatively high specific surface areas were produced, i.e., ratios of surface area to volume were fairly high. This was indicated by values of reciprocal Sauter mean diameters, RSMD's, as measured with a scattered- light scanning instrument developed at NASA Lewis Research Center. Correlating expressions were derived for the three atomizing gases over a gas temperature range of 111 to 422 K. Also, the correlation was extended to include waterjet breakup data that had been previously obtained in simulating fuel jet breakup in sonic velocity gas flow. The final correlating expression included a new dimensionless molecular-scale acceleration group. It was needed to correlate RSMD data, for LN2 and H2O sprays, with the fluid properties of the liquid jets and atomizing gases used in this investigation.

Ingebo, Robert D.↗

Two phase choke flow in tubes with very large L/D

Data were obtained for two phase and gaseous choked flow nitrogen in a long constant area duct of 16200 L/D with a diverging diffuser attached to the exit. Flow rate data were taken along five isotherms (reduced temperature of 0.81, 0.96, 1.06, 1.12, and 2.34) for reduced pressures to 3. The flow rate data were mapped in the usual manner using stagnation conditions at the inlet mixing chamber upstream of the entrance length. The results are predictable by a two phase homogeneous equilibrium choking flow model which includes wall friction. A simplified theory which in essence decouples the long tube region from the high acceleration choking region also appears to predict the data resonably well, but about 15 percent low.

Hendricks, R. C.↗

Two-phase choked flow of cryogenic fluids in converging-diverging nozzles

Data are presented for the two phase choked flow of three cryogenic fluids - nitrogen, methane, and hydrogen - in four converging-diverging nozzles. The data cover a range of inlet stagnation conditions, all single phase, from well below to well above the thermodynamic critical conditions. In almost all cases the nozzle throat conditions were two phase. The results indicate that the choked flow rates were not very sensitive to nozzle geometry. However, the axial pressure profiles, especially the throat pressure and the point of vaporization, were very sensitive to both nozzle geometry and operating conditions. A modified Henry-Fauske model correlated all the choked flow rate data to within + or - 10 percent. Neither the equilibrium model nor the Henry-Fauske model predicted throat pressures well over the whole range of data. Above the thermodynamic critical temperature the homogeneous equilibrium model was preferred for both flow rate and pressure ratio. The data of the three fluids could be normalized by the principle of corresponding states.

Simoneau, R. J.↗

Metal cooldown, flow instability, and heat transfer in two-phase hydrogen flow

Studies of the properties of five metals with varying tube-wall thickness, with or without and internal coating of trifluorochloroethylene polymer, show that wall characteristics influence flow stability, affect heat transfer coefficients, and influence the transition point from dry- to wet-wall flow.

Manson, L.↗

Bubble Formation and Detachment in Liquid Flow Under Normal and Reduced Gravity

Two-phase flows are present in a wide variety of applications for spacecraft thermal control systems design. Bubble formation and detachment is an integral part of the two-phase flow science. The authors objective is to experimentally investigate the effects of liquid cross velocity, gas velocity, and nozzle diameter on the bubble diameter at detachment under reduced and normal gravity and under relatively low gas flow rates. Results from ground (1 g) and reduced gravity experiments will be presented in this paper. For the 1 g experiment, a flow loop was designed and built to accommodate a range of liquid and gas flow rates. The reduced gravity experiment was conducted on the NASA DC-9 reduced gravity platform using the two-phase flow loop qualified for operation on the low-gravity platform. Flow visualization is accomplished using a high speed 500 frames/s camera. The results suggest that the existence of buoyancy force contributes to the faster detachment of bubbles. Buoyancy helps the detachment process which results in smaller bubbles being formed. In reduced gravity, although drag force is present, the virtual non-existence of buoyant force results in larger bubbles and longer times for detachment. Theoretical predictions are also presented in this paper and seem to agree with the experimental results.

Nahra, Henry K.↗

Application of the principle of corresponding states to two-phase choked flow.

If the possibility of applying the principle is valid, designers, using data from other fluids to support them, could apply the theory of their choice to fluids where there is little or no data, such as oxygen. Two-phase critical flow and critical flow pressure ratio of simple fluids through a nozzle are shown to nearly obey the principle of corresponding states. The normalization of corresponding states presented is supported by nitrogen and methane two-phase choked flow data. Since the reduced curves for nitrogen, oxygen, and methane are so close, it is felt that oxygen two-phase choked flow can be predicted using corresponding states reduction and relying on nitrogen and methane data to establish the appropriate theory to use.

Hendricks, R. C.↗

Bubble Formation from Wall Orifice in Liquid Cross-Flow Under Low Gravity

Two-phase flows present a wide variety of applications for spacecraft thermal control systems design. Bubble formation and detachment is an integral part of the two phase flow science. The objective of the present work is to experimentally investigate the effects of liquid cross-flow velocity, gas flow rate, and orifice diameter on bubble formation in a wall-bubble injection configuration. Data were taken mainly under reduced gravity conditions but some data were taken in normal gravity for comparison. The reduced gravity experiment was conducted aboard the NASA DC-9 Reduced Gravity Aircraft. The results show that the process of bubble formation and detachment depends on gravity, the orifice diameter, the gas flow rate, and the liquid cross-flow velocity. The data are analyzed based on a force balance, and two different detachment mechanisms are identified. When the gas momentum is large, the bubble detaches from the injection orifice as the gas momentum overcomes the attaching effects of liquid drag and inertia. The surface tension force is much reduced because a large part of the bubble pinning edge at the orifice is lost as the bubble axis is tilted by the liquid flow. When the gas momentum is small, the force balance in the liquid flow direction is important, and the bubble detaches when the bubble axis inclination exceeds a certain angle.

Nahra, Henry K.↗

Development of Flow Boiling and Condensation Experiment on the International Space Station- Normal and Low Gravity Flow Boiling Experiment Development and Test Results

Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and Critical Heat Flux (CHF) phenomena.

microgravity↗

Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomas devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1 - X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

Papell, S. Stephen↗

Liquid hydrogen mass flow through a multiple orifice Joule-Thomson device

Liquid hydrogen mass flow rate, pressure drop, and temperature drop data were obtained for a number of multiple orifice Joule-Thomson devices known as visco jets. The present investigation continues a study to develop an equation for predicting two phase flow of cryogens through these devices. The test apparatus design allowed isenthalpic expansion of the cryogen through the visco jets. The data covered a range of inlet and outlet operating conditions. The mass flow rate range single phase or two phase was 0.015 to 0.98 lbm/hr. The manufacturer's equation was found to overpredict the single phase hydrogen data by 10 percent and the two phase data by as much as 27 percent. Two modifications of the equation resulted in a data correlation that predicts both the single and two phase flow across the visco jet. The first modification was of a theoretical nature, and the second strictly empirical. The former reduced the spread in the two phase data. It was a multiplication factor of 1-X applied to the manufacturer's equation. The parameter X is the flow quality downstream of the visco jet based on isenthalpic expansion across the device. The latter modification was a 10 percent correction term that correlated 90 percent of the single and two phase data to within +/- 10 percent scatter band.

Papell, S. S.↗

Studies of Two-Phase Gas-Liquid Flow in Microgravity

Two-phase gas-liquid flows are expected to occur in many future space operations. Due to a lack of buoyancy in the microgravity environment, two-phase flows are known to behave differently than those in earth gravity. Despite these concerns, little research has been conducted on microgravity two-phase flow and the current understanding is poor. This dissertation describes an experimental and modeling study of the characteristics of two-phase flows in microgravity. An experiment was operated onboard NASA aircraft capable of producing short periods of microgravity. In addition to high speed photographs of the flows, electronic measurements of void fraction, liquid film thickness, bubble and wave velocity, pressure drop and wall shear stress were made for a wide range of liquid and gas flow rates. The effects of liquid viscosity, surface tension and tube diameter on the behavior of these flows were also assessed. From the data collected, maps showing the occurrence of various flow patterns as a function of gas and liquid flow rates were constructed. Earth gravity two-phase flow models were compared to the results of the microgravity experiments and in some cases modified. Models were developed to predict the transitions on the flow pattern maps. Three flow patterns, bubble, slug and annular flow, were observed in microgravity. These patterns were found to occur in distinct regions of the gas-liquid flow rate parameter space. The effect of liquid viscosity, surface tension and tube diameter on the location of the boundaries of these regions was small. Void fraction and Weber number transition criteria both produced reasonable transition models. Void fraction and bubble velocity for bubble and slug flows were found to be well described by the Drift-Flux model used to describe such flows in earth gravity. Pressure drop modeling by the homogeneous flow model was inconclusive for bubble and slug flows. Annular flows were found to be complex systems of ring-like waves and a substrate film. Pressure drop was best fitted with the Lockhart- Martinelli model. Force balances suggest that droplet entrainment may be a large component of the total pressure drop.

Bousman, William Scott↗

Flow Boiling and Condensation Experiment: Flow Boiling in a Rectangular Channel with Subcooled Inlet Conditions in Microgravity

Two-phase thermal management subsystems that take advantage of both the sensible and latent heat of a working fluid can potentially yield significant enhancements in overall performance by adopting heat transfer processes that are based on phase transition like boiling and condensation. Performance of terrestrial two-phase flow systems may be predictable because the hydrodynamic and body forces are understood, however, in microgravity, which is predominant during planetary space travel, forces that are masked by the strong body force on Earth (gravitational or buoyancy force) reappear with different magnitude and influence. The need arose for a facility that provides for two-phase flow with phase transition testing in microgravity. The Flow Boiling and Condensation Experiment (FBCE) is a facility that was launched to the International Space Station in August of 2021 and is in operation since February of 2022. This facility enables investigators to perform two-phase flow and phase transition research in flow boiling and condensation. Along with the test module that is experiment specific, the FBCE system consists of the fluid, avionics, and software subsystems. Currently two test modules, namely, the Flow Boiling Module (FBM) and the Condensation Module for Heat Transfer (CM-HT) are available. A third module, the Transfer Line test Module (TL) is being developed. The fluid subsystem conditions and delivers the fluid at the desired thermodynamic state to the test module. It consists of two fluid modules and a heater module that are connected by flex hoses for fluid circulation and by data and electrical cables for control and data acquisition. Two avionics modules acquire pressure and temperature data from various sensors in the flow loop. For FBM, a high-speed camera is available to acquire images of the boiling process. Experiments are operated autonomously by software and are based on an Experiment Parameters Master Table (EPMT) that is uploaded to ISS and is executed by the FBCE flight software. This presentation briefly introduces the objectives of FBCE and provides a system description of the experiment onboard of the ISS/Fluid Integrated Rack (FIR). Results of the test campaign carried out using the FBM are presented. Specifically, microgravity flow boiling of n-perfluorohexane (test fluid) is discussed with subcooled inlet conditions in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m2s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Image sequences acquired via high-speed-video are shown to elucidate the interfacial flow physics. The effects of various parameters on flow boiling heat transfer in microgravity, from the onset of boiling to the critical heat flux are discussed. Heat transfer results are presented in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient, and the critical heat flux.

Two-phase flow and phase transition↗

Structural and preliminary thermal performance testing of a pressure activated contact heat exchanger

A contact heat exchanger concept is being developed for use onboard Space Station as an interface device between external thermal bus and pressurized modules. The concept relies on mechanical contact activated by the fluid pressure inside thin-walled tubes. Structural testings were carried out to confirm the technology feasibility of using such thin-walled tubes. The test results also verified the linear elastic stress analysis which was used to predict the tube mechanical behaviors. A preliminary thermal testing was also performed with liquid Freon-11 flowing inside tubes and heat being supplied by electrical heating from the bottom of the contact heat exchanger baseplate. The test results showed excellent agreement of test data with analytical prediction for all thermal resistances except for the two-phase flow characteristics. Testing with two-phase flow inside tubes will, however, be performed on the NASA-JSC test bed.

Lee, C. Y.↗