Search NASA⌕ Search

SEARCH · Search NASA

Results for “Uncertainty Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

INTEGRATION OF SYSTEM COMPONENTS AND UNCERTAINTY ANALYSIS - HANFORD EXAMPLES

{sm_bullet} Deterministic 'One Off' analyses as basis for evaluating sensitivity and uncertainty relative to reference case {sm_bullet} Spatial coverage identical to reference case {sm_bullet} Two types of analysis assumptions - Minimax parameter values around reference case conditions - 'What If' cases that change reference case condition and associated parameter values {sm_bullet} No conclusions about likelihood of estimated result other than' qualitative expectation that actual outcome should tend toward reference case estimate

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adjoint-Based Implicit Uncertainty Analysis for Figures of Merit in a Laser Inertial Fusion Engine

A primary purpose of computational models is to inform design decisions and, in order to make those decisions reliably, the confidence in the results of such models must be estimated. Monte Carlo neutron transport models are common tools for reactor designers. These types of models contain several sources of uncertainty that propagate onto the model predictions. Two uncertainties worthy of note are (1) experimental and evaluation uncertainties of nuclear data that inform all neutron transport models and (2) statistical counting precision, which all results of a Monte Carlo codes contain. Adjoint-based implicit uncertainty analyses allow for the consideration of any number of uncertain input quantities and their effects upon the confidence of figures of merit with only a handful of forward and adjoint transport calculations. When considering a rich set of uncertain inputs, adjoint-based methods remain hundreds of times more computationally efficient than Direct Monte-Carlo methods. The LIFE (Laser Inertial Fusion Energy) engine is a concept being developed at Lawrence Livermore National Laboratory. Various options exist for the LIFE blanket, depending on the mission of the design. The depleted uranium hybrid LIFE blanket design strives to close the fission fuel cycle without enrichment or reprocessing, while simultaneously achieving high discharge burnups with reduced proliferation concerns. Neutron transport results that are central to the operation of the design are tritium production for fusion fuel, fission of fissile isotopes for energy multiplication, and production of fissile isotopes for sustained power. In previous work, explicit cross-sectional uncertainty analyses were performed for reaction rates related to the figures of merit for the depleted uranium hybrid LIFE blanket. Counting precision was also quantified for both the figures of merit themselves and the cross-sectional uncertainty estimates to gauge the validity of the analysis. All cross-sectional uncertainties were small (0.1-0.8%), bounded counting uncertainties, and were precise with regard to counting precision. Adjoint/importance distributions were generated for the same reaction rates. The current work leverages those adjoint distributions to transition from explicit sensitivities, in which the neutron flux is constrained, to implicit sensitivities, in which the neutron flux responds to input perturbations. This treatment vastly expands the set of data that contribute to uncertainties to produce larger, more physically accurate uncertainty estimates.

42 ENGINEERING↗

Improving Experimental Design through Uncertainty Analysis

In this paper, the development of a fission-gas collecting and physical-analysis-enabling instrument was proposed for small-volume determination. Analysis specifications require a design capable of accurately and repeatably determining volumes in the range of 0.07–2.5 mL. This system relies on a series of gas expansions originating from a cylinder with known internal volume. The combined gas law is used to derive the unknown volumes from these expansions. Initial system designs included one of two known volumes, 11.85 ± 0.34 mL and 5.807 ± 0.078 mL, with a manifold volume of 32 mL. Results obtained from modeling this system’s operation showed that 0.07 mL can be determined with a relative expanded uncertainty greater than 300% (k = 2) for a single replicate, which was unacceptable for the proposed experimental design. Initial modeling showed that the volume connecting the known volume and rodlet, i.e., the manifold volume, and the sensitivity of the pressure sensor were key contributors to the expanded uncertainty of the measured rodlet volume. The system’s design limited the available options for pressure sensors, so emphasis was placed on the design of the manifold volume. The final system design reduced the manifold volume to 17 mL. These changes in design, combined with replicate analysis, were able to reduce the relative expanded uncertainty by ±12% (k = 2) for the 0.07 mL volume.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy

Purpose: To estimate the total dosimetric uncertainty at the tumor apex for ocular brachytherapy treatments delivered using 16 mm Collaborative Ocular Melanoma Study (COMS) and Super9 plaques loaded with {sup 125}I seeds in order to determine the size of the apex margin that would be required to ensure adequate dosimetric coverage of the tumor. Methods: The total dosimetric uncertainty was assessed for three reference tumor heights: 3, 5, and 10 mm, using the Guide to the expression of Uncertainty in Measurement/National Institute of Standards and Technology approach. Uncertainties pertaining to seed construction, source strength, plaque assembly, treatment planning calculations, tumor height measurement, plaque placement, and plaque tilt for a simple dome-shaped tumor were investigated and quantified to estimate the total dosimetric uncertainty at the tumor apex. Uncertainties in seed construction were determined using EBT3 Gafchromic film measurements around single seeds, plaque assembly uncertainties were determined using high resolution microCT scanning of loaded plaques to measure seed positions in the plaques, and all other uncertainties were determined from the previously published studies and recommended values. All dose calculations were performed using PLAQUESIMULATOR v5.7.6 ophthalmic treatment planning system with the inclusion of plaque heterogeneity corrections. Results: The total dosimetric uncertainties at 3, 5, and 10 mm tumor heights for the 16 mm COMS plaque were 17.3%, 16.1%, and 14.2%, respectively, and for the Super9 plaque were 18.2%, 14.4%, and 13.1%, respectively (all values with coverage factor k = 2). The apex margins at 3, 5, and 10 mm tumor heights required to adequately account for these uncertainties were 1.3, 1.3, and 1.4 mm, respectively, for the 16 mm COMS plaque, and 1.8, 1.4, and 1.2 mm, respectively, for the Super9 plaque. These uncertainties and associated margins are dependent on the dose gradient at the given prescription depth, thus resulting in the changing uncertainties and margins with depth. Conclusions: The margins determined in this work can be used as a guide for determining an appropriate apex margin for a given treatment, which can be chosen based on the tumor height. The required margin may need to be increased for more complex scenarios (mushroom shaped tumors, tumors close to the optic nerve, oblique muscle related tilt, etc.) than the simple dome-shaped tumor examined and should be chosen on a case-by-case basis. The sources of uncertainty contributing most significantly to the total dosimetric uncertainty are seed placement within the plaques, treatment planning calculations, tumor height measurement, and plaque tilt. This work presents an uncertainty-based, rational approach to estimating an appropriate apex margin.

60 APPLIED LIFE SCIENCES↗

A Stochastic Collocation Algorithm for Uncertainty Analysis

This report describes a stochastic collocation method to adequately handle a physically intrinsic uncertainty in the variables of a numerical simulation. For instance, while the standard Galerkin approach to Polynomial Chaos requires multi-dimensional summations over the stochastic basis functions, the stochastic collocation method enables to collapse those summations to a one-dimensional summation only. This report furnishes the essential algorithmic details of the new stochastic collocation method and provides as a numerical example the solution of the Riemann problem with the stochastic collocation method used for the discretization of the stochastic parameters.

Mathelin, Lionel↗

Post-Calibration Uncertainty Analysis for Travel Times at a Naval Weapons Industrial Reserve Plant

The Naval Weapons Industrial Reserve Plant (NWIRP) in McGregor, Texas began manufacturing explosives in 1980 and several hazardous chemicals were discovered in lakes and streams surrounding the site in 1998. Contaminants traveled to local lakes and streams much faster than initially predicted. This research estimated contaminant travel times and identified locations where monitoring wells should be installed to yield the greatest reductions in uncertainties in travel-time predictions. To this end, groundwater and particle-tracking models for NWIRP site were built to predict hydraulic heads and contaminant travel times. Next, parameter (hydraulic conductivities) uncertainties, parameter identifiabilities, observation (hydraulic heads) worth, and predictive (contaminant travel times) uncertainties were quantified. Parameter uncertainties were reduced by up to 92%; a total of 19 of 158 parameters were at least moderately identifiable; travel-time uncertainties were reduced up to 92%. Additionally, travel-time predictions and post-calibration parameter distributions were generated using the null-space Monte Carlo (NSMC) technique. NSMC predicted that conservative tracers exited the flow system within a year, which matches with field data. Finally, an observations-worth analysis found that additional 11 more measurements would reduce travel-time uncertainties by factors from 1.04 to 4.3 over existing data if monitoring wells were installed at the suggested locations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Robust two-colour pyrometry uncertainty analysis to acquire spatially-resolved measurements

Two-colour pyrometry (2CP) has been used over several decades to study engine-relevant combustion processes, but results are generally regarded as qualitative or semi-quantitative. In many current 2CP systems, large measurement errors are introduced by parallax because the two measured wavelengths are not from the same line of sight. Here this work presents a spatially-resolved 2CP system with the objective of quantifying and reducing measurement uncertainty. An optical setup that eliminates parallax in 2CP is used together with pixel-by-pixel calibration of the camera sensor to increase measurement accuracy. Primary uncertainty terms are identified, and an error propagation analysis is performed to compute uncertainties in the final results of soot temperature, soot concentration parameter, KL, and soot mass. These methodologies are applied to investigate an auto-igniting fuel spray in a constant pressure flow rig at diesel-like conditions of high ambient pressure and temperature. Results show bias uncertainty of around 200 K (≈10%) for temperature and about 40%–60% for KL. High uncertainty was found to occur on the diffusion flame front where both optical thickness and soot concentrations are small. However, these uncertain measurement zones with relatively low soot concentrations contribute minimally to the total soot mass present in the reacting jet during the temporal evolution of the flame.

42 ENGINEERING↗

A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO

This report addresses uncertainties pertaining to brachytherapy single-source dosimetry preceding clinical use. The International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (GUM) and the National Institute of Standards and Technology (NIST) Technical Note 1297 are taken as reference standards for uncertainty formalism. Uncertainties in using detectors to measure or utilizing Monte Carlo methods to estimate brachytherapy dose distributions are provided with discussion of the components intrinsic to the overall dosimetric assessment. Uncertainties provided are based on published observations and cited when available. The uncertainty propagation from the primary calibration standard through transfer to the clinic for air-kerma strength is covered first. Uncertainties in each of the brachytherapy dosimetry parameters of the TG-43 formalism are then explored, ending with transfer to the clinic and recommended approaches. Dosimetric uncertainties during treatment delivery are considered briefly but are not included in the detailed analysis. For low- and high-energy brachytherapy sources of low dose rate and high dose rate, a combined dosimetric uncertainty <5% (k=1) is estimated, which is consistent with prior literature estimates. Recommendations are provided for clinical medical physicists, dosimetry investigators, and source and treatment planning system manufacturers. These recommendations include the use of the GUM and NIST reports, a requirement of constancy of manufacturer source design, dosimetry investigator guidelines, provision of the lowest uncertainty for patient treatment dosimetry, and the establishment of an action level based on dosimetric uncertainty. These recommendations reflect the guidance of the American Association of Physicists in Medicine (AAPM) and the Groupe Europeen de Curietherapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) for their members and may also be used as guidance to manufacturers and regulatory agencies in developing good manufacturing practices for sources used in routine clinical treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainty Analysis on the Design of Thermal Conductivity Measurement by a Guarded Cut-Bar Technique

A technique adapted from the guarded-comparative-longitudinal heat flow method was selected for the measurement of the thermal conductivity of a nuclear fuel compact over a temperature range characteristic of its usage. This technique fulfills the requirement for non-destructive measurement of the composite compact. Although numerous measurement systems have been created based on the guarded comparative method, comprehensive systematic (bias) and measurement (precision) uncertainty associated with this technique have not been fully analyzed. In addition to the geometric effect in the bias error, which has been analyzed previously, this paper studies the working condition which is another potential error source. Using finite element analysis, this study showed the effect of these two types of error sources in the thermal conductivity measurement process and the limitations in the design selection of various parameters by considering their effect on the precision error. The results and conclusions provide valuable reference for designing and operating an experimental measurement system using this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strain Gauge Balance Uncertainty Analysis at NASA Langley: A Technical Review

This paper describes a method to determine the uncertainties of measured forces and moments from multi-component force balances used in wind tunnel tests. A multivariate regression technique is first employed to estimate the uncertainties of the six balance sensitivities and 156 interaction coefficients derived from established balance calibration procedures. These uncertainties are then employed to calculate the uncertainties of force-moment values computed from observed balance output readings obtained during tests. Confidence and prediction intervals are obtained for each computed force and moment as functions of the actual measurands. Techniques are discussed for separate estimation of balance bias and precision uncertainties.

John S Tripp↗

Initial Uncertainty Analysis of Carbon Tetrachloride Contamination and Remediation in the Ringold A and Lower Mud Units at the Central Plateau

The long-term effectiveness of groundwater cleanup at the Hanford Site Central Plateau depends on predictive models that can capture key uncertainties in contaminant fate and transport. Carbon tetrachloride (CCl 4 ), a persistent and toxic compound, presents particular challenges due to variability in degradation rates, uncertainty in initial plume distribution, and subsurface heterogeneity. These uncertainties directly influence plume persistence, migration pathways, and remedy performance, and thus must be systematically evaluated to support long-term remediation planning. To address these gaps, a large-scale Monte Carlo analysis was conducted using the Plateau to River (P2R) model framework. The modeling approach parameterized three primary uncertainty factors: (1) degradation rate, (2) initial plume distribution, and (3) hydraulic conductivity. Degradation was represented as a first-order process, with half-lives ranging from 70 to 700 years. Initial plume distributions were created using a geostatistical simulation method (sgsim), which generates many equally plausible versions of how contaminants might be distributed underground. From this, 100 different scenarios were mapped onto the P2R grid. Variability in hydraulic conductivity was represented in a similar way, with 100 scenarios each for the Ringold Lower Mud and Ringold A units (layers 6 and 7), based on fitted exponential variograms and conditioned to well data. In total, more than 1000 realizations were simulated to assess plume behavior under uncertainty. Results demonstrate that degradation kinetics exert the strongest control over plume persistence: Shorter half-lives produced rapid mass reduction, while longer half-lives yielded persistent plumes with limited attenuation. A nonlinear response was observed, with steep mass reductions at half-lives greater than 200 years and near-linear declines beyond this threshold, reflecting interactions between degradation and pumping. The initial plume distribution strongly influenced early transport patterns, with broader sources generating larger plume footprints, although pump-and-treat operations constrained plume migration to managed areas. By comparison, hydraulic conductivity variability in the Ringold units had only a secondary influence, modifying spreading behavior without altering the dominant migration pathways governed by source configuration and hydraulic controls. Overall, the analysis highlights that uncertainty in degradation rate and initial plume configuration are the primary drivers of variability in plume predictions, while conductivity heterogeneity plays a limited role. These findings underscore the need for improved site-specific data on degradation processes and source characterization to enhance the reliability of long-term performance assessments and to better inform remedial decision-making at the Central Plateau.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Statistical Sampling Method for Uncertainty Analysis with SCALE

A new statistical sampling sequence called Sampler has been developed for the SCALE code system. Random values for the input multigroup cross sections are determined by using the XSUSA program to sample uncertainty data provided in the SCALE covariance library. Using these samples, Sampler computes perturbed self-shielded cross sections and propagates the perturbed nuclear data through any specified SCALE analysis sequence, including those for criticality safety, lattice physics with depletion, and shielding calculations. Statistical analysis of the output distributions provides uncertainties and correlations in the desired responses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a statistical sampling method for uncertainty analysis with SCALE

A new statistical sampling sequence called Sampler has been developed for the SCALE code system. Random values for the input multigroup cross sections are determined by using the XSUSA program to sample uncertainty data provided in the SCALE covariance library. Using these samples, Sampler computes perturbed self-shielded cross sections and propagates the perturbed nuclear data through any specified SCALE analysis sequence, including those for criticality safety, lattice physics with depletion, and shielding calculations. Statistical analysis of the output distributions provides uncertainties and correlations in the desired responses. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainty analysis of densities and isotopics: Handling correlations

This paper discusses two cases of correlated parameters in uncertainty analyses: (1) the case of measured mass, density, and volume or spatial dimension correlations; and (2) the case of measured material isotopics, where increasing one atom fraction must cause the others to decrease. In the first case, an equation is derived that has a term due to uncertain density, a term due to uncertain dimensions, and a term due to the correlation between density and dimensions. In a numerical test problem, this equation gives the same result as the standard equation that treats mass and dimensions independently. In the case of isotopics, an equation is derived relating the uncertainty due to uncertain isotopic fractions to the sensitivities to isotopic densities, which are easier to calculate. The equation is verified in a test problem. (authors)

97 MATHEMATICS AND COMPUTING↗

Uncertainty Analysis in Critical Experiments of SORA Mockup

A series of static critical experiments were completed from September 1965 to August 1966 at the Oak Ridge National Laboratory Critical Experiments Facility (ORCEF) in support of the design of the Sorgente Rapida Reactor (SORA) under a cooperative agreement between EURATOM and the U.S. Atomic Energy Commission. The SORA which had been proposed by EURATOM and was described by Raievski and Larrimore was designed to be composed of rods of highly enriched uranium alloy latticed, as a fast, reflected, repetitively pulsed reactor to serve as a high-intensity source of neutrons for time-of-flight measurements. More information about the SORA design can be obtained in some references. The critical experiments, not including pulse testing, were performed with a mockup of the SORA reactor differing from the reactor principally in the use of iron in place of the coolant, of iron as reflector, and of uranium metal fuel in place of the alloy. A summary of the experiments for the mockup was compiled in report ORNL- 4263, in June, 1968, then published as a paper in 1969. Based on the available data from papers, reports mentioned above and the logbook, the typical 15 critical experiments were evaluated for experimental uncertainties for further benchmark analysis and inclusion in the ICSBEP Handbook. Through a series of rigorous procedures in analysis of the original experimental measurement data, the dimensions and displacement of individual components, and the isotopic contents, mass, and impurities of the individual components, the experimental uncertainties for the 15 configurations have been evaluated to be 0.00219 ∼0.00229 Δk{sub eff} for 11 configurations in type of the Reference Assembly, 0.00179 ∼0.00189 Δk{sub eff} for 4 configurations in type of the All-Iron Assembly. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity and Uncertainty Analysis of Generator Failures under Extreme Temperature Scenarios in Power Systems

This report summarizes work done under the Verification, Validation, and Uncertainty Quantification (VVUQ) thrust area of the North American Energy Resilience Model (NAERM) Program. The specific task of interest described in this report is focused on sensitivity analysis of scenarios involving failures of both wind turbines and thermal generators under extreme cold-weather temperature conditions as would be observed in a Polar Vortex event.

17 WIND ENERGY↗

Uncertainty analysis of signal deconvolution using a measured instrument response function

A common analysis procedure minimizes the ln-likelihood that a set of experimental observables matches a parameterized model of the observation. The model includes a description of the underlying physical process as well as the instrument response function (IRF). Here, we investigate the National Ignition Facility (NIF) neutron time-of-flight (nTOF) spectrometers, the IRF is constructed from measurements and models. IRF measurements have a finite precision that can make significant contributions to the uncertainty estimate of the physical model’s parameters. Finally, we apply a Bayesian analysis to properly account for IRF uncertainties in calculating the ln-likelihood function used to find the optimum physical parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗