At least 199 records · Page 11

Development, verification, and validation of comprehensive acoustic fluid-structure interaction capabilities in an open-source computational platform

The acoustic fluid-structure interaction (FSI) formulation is a practical numerical approach for the seismic analysis of fluid-filled tanks. However, there are no verification and validation studies reported in the literature that demonstrate the ability of an acoustic FSI numerical model to predict responses important to structural and mechanical design for intense translational and rotational earthquake inputs. Herein, an acoustic FSI formulation is implemented in the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE), and is formally verified and validated using analytical solutions and code-to-code verification, and experimental data, respectively. The analytical solutions are for small amplitude, unidirectional seismic inputs. The code-to-code verification utilizes a previously verified and validated Arbitrary Lagrangian-Eulerian (ALE) numerical model in the commercial finite element code LS-DYNA. The validation studies utilize a comprehensive data set assembled from results of 3D earthquake-simulator tests of a fluid-filled vessel. The acoustic numerical model in MOOSE is verified and validated for hydrodynamic pressures and support reactions except for cases that involve significant convective response. For small amplitude inputs, numerically predicted wave heights match those of the analytical solutions. The numerical model is not verified and validated for wave height calculations under intense 3D seismic inputs. The run times for the acoustic FSI simulations in MOOSE are an order of magnitude, or more, shorter than for the corresponding ALE simulations in LS-DYNA. The utility of the MOOSE acoustic FSI implementation is demonstrated by seismic analysis of a building equipped with a fluid-filled, advanced nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New Whole-House Solutions Case Study: Testing Ductless Heat Pumps in High-Performance Affordable Housing, the Woods at Golden Given - Tacoma, Washington

The Woods is a 30-home, high- performance, energy efficient sustainable community built by Habitat for Humanity (HFH). With Support from Tacoma Public Utilities, Washington State University (part of the Building America Partnership for Improved Residential Construction) is researching the energy performance of these homes and the ductless heat pumps (DHP) they employ. This project provides Building America with an opportunity to: field test HVAC equipment, ventilation system air flows, building envelope tightness, lighting, appliance, and other input data that are required for preliminary Building Energy Optimization (BEopt™) modeling and ENERGY STAR® field verification; analyze cost data from HFH and other sources related to building-efficiency measures that focus on the DHP/hybrid heating system and heat recovery ventilation system; evaluate the thermal performance and cost benefit of DHP/hybrid heating systems in these homes from the perspective of homeowners; compare the space heating energy consumption of a DHP/electric resistance (ER) hybrid heating system to that of a traditional zonal ER heating system; conduct weekly "flip-flop tests" to compare space heating, temperature, and relative humidity in ER zonal heating mode to DHP/ER mode.

Appliance↗

Validation and Verification of MCNP6 Against High-Energy Experimental Data and Calculations by Other Codes. III. The MPI Testing Primer

This primer presents a set of Validation and Verification (V&V) MCNP6 results calculated in parallel, with MPI, obtained mostly using its event generators at intermediate and high-energies, but also several examples of results using data libraries at energies below 150 MeV, against various recent experimental data. It is the third part of a set of MCNP6 Testing Primers, after its first, LA-UR-11-05129, and second, LA-UR-11-05627, publications. The MCNP6 test-problems discussed here are presented in the /VALIDATION CEM/, /VALIDATION LAQGSM/, and /DELAYED PARTICLES/ subdirectories in the MCNP6 /Testing/ directory. README files that contain short descriptions of every input file, the experiment, the quantity of interest that the experiment measures and its description in the MCNP6 output files, and the publication reference of that experiment are presented for every test-problem. Templates for plotting the corresponding results with xmgrace as well as pdf files with figures representing the final results of our V&V efforts are presented. Several technical “bugs” in MCNP6 while running it in parallel with MPI using its event generators were discovered during our current V&V of MCNP6 and were fixed mostly by Dr. Jeffrey S. Bull. Our results show that MCNP6 using its CEM03.03, LAQGSM03.03, Bertini, INCL+ABLA, and ISABEL event generators describes, as a rule, reasonably well different intermediate- and high-energy measured data and agrees very well with calculations by other codes. Just as expected, the MCNP6 results obtained with MPI are practically the same as the ones calculated with MCNP6 in a sequential mode. This primer isn’t meant to be read from cover to cover. Readers may skip some sections and go directly to a test-problem they are interested in.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-year assessment of the impact of ship-borne radiosonde observations on polar WRF forecasts in the Arctic

Abstract To compensate for the lack of conventional observations over the Arctic Ocean, ship-borne radiosonde observations have been regularly carried out during summer Arctic expeditions and the observed data have been broadcast via the global telecommunication system since 2017. With these data obtained over the data-sparse Arctic Ocean, observing system experiments were carried out using a polar-optimized version of the Weather Research and Forecasting (WRF) model and the WRF Data Assimilation (WRFDA) system to investigate their effects on analyses and forecasts over the Arctic. The results of verification against reanalysis data reveal: (1) DA effects on analyses and forecasts; (2) the reason for the year-to-year variability of DA effects; and (3) the possible role of upper-level potential vorticity in delayed DA effects. The overall assimilation effects of the extra data on the analyses and forecasts over the Arctic are positive. Initially, the DA effects are the most apparent in the temperature variables in the middle/lower troposphere, which spread to the wind variables in the upper troposphere. The effects decrease with time but reappear after approximately 120 h, even in the 240-h forecasts. The effects on forecasts vary depending on the proximity of the radiosonde observation locations to the high synoptic variability. The upper-level potential vorticity is known to play an important role in the development of Arctic cyclones, and it is suggested as a possible explanation for the delayed DA effects after about 120 h.

Geology↗

Information Filters for Safeguards Applications: A Scoping Study

A core concern of the Department of Energy is protecting sensitive information in the face of verification agreements that may make use of increasingly sophisticated and intrusive sensors. The conflict between intrusiveness and information protection is evident in existing treaties, such as the Chemical Weapons Convention (CWC) and the Additional Protocol (AP), where Congress has seen a need to step in and enact implementing legislation to protect, for example, sensitive information such as certain unique chemical signatures, but in so doing has introduced complexities into U.S. treaty compliance policy. Information barriers or filters (IFs) – broadly defined as physical and/or encryption mechanisms that preclude acquisition of sensitive, quantitative information while allowing the acquisition of treaty-relevant qualitative information by an inspectorate – could play a useful role in avoiding this type of conflict. In order to stimulate new thinking on ways to meet existing and future safeguard challenges, this scoping study investigates how IFs – a technique borrowed from the realm of arms control verification - might contribute to international safeguards activities. Information filters (IFs) have long been recognized as an important tool for the protection of sensitive signals and other data in the verification of bilateral and multilateral arms control treaties. The implementation of NPT safeguards, while differing somewhat in context from arms control verification, involves similar sensitivity concerns. This report examines whether or not IFs can be useful in the world of international safeguards, and provides a survey of methods of barring or filtering information that could be applied. The study finds that while many safeguards activities involve non sensitive data, there are also a number of areas where IFs are already in use and others where IFs could make a useful contribution. Examples include verification of enrichment plants, complementary access inspections, and the Additional Protocol (AP) to Comprehensive Safeguards Agreements (CSAs) under the Nuclear Non-proliferation Treaty (NPT).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Potosi Reservoir Model 2013

As a part of a larger project co-funded by the United States Department of Energy (US DOE) to evaluate the potential of formations within the Cambro-Ordovician strata above the Mt. Simon as potential targets for carbon sequestration in the Illinois and Michigan Basins, the Illinois Clean Coal Institute (ICCI) requested Schlumberger to evaluate the potential injectivity and carbon dioxide (CO2) plume size of the Cambrian Potosi Formation. The evaluation of this formation was accomplished using wireline data, core data, pressure data, and seismic data from the US DOE-funded Illinois Basin–Decatur Project (IBDP) being conducted by the Midwest Geological Sequestration Consortium in Macon County, Illinois. In 2010, technical performance evaluations on the Cambrian Potosi Formation were performed through reservoir modeling. The data included formation tops from mud logs, well logs from the VW1 and the CCS1 wells, structural and stratigraphic formation from three dimensional (3D) seismic data, and field data from several waste water injection wells for Potosi Formation. Intention was for two million tons per annum (MTPA) of CO2 to be injected for 20 years. In the preceding, the 2010 Potosi heterogeneous model (referred to as the "Potosi Dynamic Model 2010" in this topical report) was re-run using a new injection scenario; 3.2 MTPA for 30 years. The extent of the Potosi Dynamic Model 2010, however, appeared too small for the new injection target. It was not sufficiently large enough to accommodate the evolution of the plume. The new model, Potosi Dynamic Model 2013a, was built by extending the Potosi Dynamic Model 2010 grid to 30 miles x 30 miles (48.3km x48.3km), while preserving all property modeling workflows and layering. This model was retained as the base case of Potosi Dynamic Model 2013a. The Potosi reservoir model was updated to take into account the new data from the verification well VW2 which was drilled in 2012. The new porosity and permeability modeling was performed to take into account the log data from the new well. Revisions of the 2010 modeling assumptions were also done on relative permeability, capillary pressures, formation water salinity, and the maximum allowable well bottomhole pressure. Dynamic simulations were run using the injection target of 3.2 MTPA for 30 years. This new dynamic model was named Potosi Dynamic Model 2013b. Due to the major uncertainties on the vugs permeability, two models were built; the Pessimistic and Optimistic Cases. The Optimistic Case assumes vugs permeability of 9,000 mD, which is analog to the vugs permeability identified in the pressure fall off test of a waste water injector in the Tuscola site, approx. 40 miles (64.4km) away from the IBDP area. The Pessimistic Case assumes that the vugs permeability is equal to the log data, which does not take into account the permeability from secondary porosity. The probability of such case is deemed low and could be treated as the worst case scenario, since the contribution of secondary porosity to the permeability is neglected and the loss circulation events might correspond to a much higher permeability. It is considered important, however, to identify the range of possible reservoir performance since there are no rigorous data available for the vugs permeability. The Optimistic Case gives an average CO2 injection rate of 0.8 MTPA and cumulative injection of 26 MT in 30 years, which corresponds to 27% of the injection target. The injection rate is approx. 3.2 MTPA in the first year as the well is injecting into the surrounding vugs, and declines rapidly to 0.8 MTPA in year 4 once the surrounding vugs are full and the CO2 start to reach the matrix. This implies that according to this preliminary model, a minimum of four (4) wells could be required to achieve the injection target. This result is lower than the injectivity estimated in the Potosi Dynamic Model 2013a (43 MT in 30 years), since the permeability model applied in the Potosi Dynamic Model 2013b is more conservative. This revision was deemed necessary to treat the uncertainty in a more appropriate manner. As the CO2 follows the paths where vugs interconnection exists, a reasonably large and irregular plume extent was created. For the Optimistic Case, the plume extends 17 miles (27.4km) in E-W and 14 miles (22.5km) in N-S directions after 30 years. After injection is completed, the plume continues to migrate laterally, mainly driven by the remaining pressure gradient. After 100 years post injection, the plume extends 20 miles (32.2km) in E-W and 15.5 miles (24.9km) in N-S directions. Should the targeted cumulative injection of 96 MT be achieved; a much larger plume extent could be expected. For the Optimistic Case, the increase of reservoir pressure at the end of injection is approximately 1200 psia (8,274 kPa) around the injector and gradually decreases away from the well. The reservoir pressure increase is less than 30 psia (206.8 kPa) beyond 14 miles (22.5km) away from injector. Should the targeted cumulative injection of 96 MT be achieved; a much larger areal pressure increase could be expected. The initial reservoir pressure is nearly restored after approximately 100 years post injection. The presence of matrix slows down the pressure dissipations. The Pessimistic Case gives an average CO2 injection rate of 0.2 MTPA and cumulative injection of 7 MT in 30 years, which corresponds to 7% of the injection target. This implies that in the worst case scenario, a minimum of sixteen (16) wells could be required to achieve the injection target. The present evaluation is mainly associated with uncertainty on the vugs permeability, distribution, and interconnectivity. The different results indicated by the Optimistic and Pessimistic Cases signify the importance of vugs permeability characterization. Therefore, injection test and pressure interference test among the wells could be considered to evaluate the local vugs permeability, extent, and interconnectivity. Porosity mapping derived from the seismic inversion could also be used in the succeeding task to characterize the lateral porosity distribution within the reservoir. With or without seismic inversion porosity mapping, it is worth exploring whether increased lateral heterogeneity plays a significant role in Potosi injectivity. Investigations on vugular, dolomitic outcrops suggest that there may be significantly greater lateral heterogeneity than what has been modeled here. Facies modeling within the Potosi has yet to be thoroughly addressed. The carbonates during the time of deposition are believed to be regionally extensive. However, it may be worth delineating the reservoir with other regional wells or modern day analogues to understand the extent of the Potosi. More specifically, the model could incorporate lateral changes or trends if deemed necessary to represent facies transition. Data acquisitions to characterize the fracture pressure gradient, the formation water properties, the relative permeability, and the capillary pressure could also be considered in order to allow a more rigorous evaluation of the Potosi storage performance. A simulation using several injectors could also be considered to determine the required number of wells to achieve the injection target while taking into account the pressure interference.

Adushita, Yasmin↗

Varied farm-level carbon intensities of corn feedstock help reduce corn ethanol greenhouse gas emissions

Abstract A reduction in the overall carbon intensity (CI) of a crop-based biofuel can be achieved by cutting down the CI of the biofuel’s feedstock, which in turn correlates significantly to agricultural management practices. Proposals are being made to incentivize low-carbon biofuel feedstocks under U.S. fuel regulatory programs to promote sustainable farming practices by individual farms. For such an incentive scheme to function properly, robust data collection and verification are needed at the farm level. This study presents our collaboration with U.S. private sector companies to collect and verify the corn production data necessary for feedstock-specific CI calculation at the farm level, through a carefully designed questionnaire, to demonstrate the practicality and feasibility of data collection at scale. We surveyed 71 farms that produced 0.2 million metric tons of corn grain in 2018 in a Midwestern U.S. state to obtain information on key parameters affecting corn ethanol feedstock CI, such as grain yields, fertilizer/chemical application rates, and agronomic practices. Feedstock-specific CI was calculated in the unit of grams (g) CO 2 equivalent (CO 2 e) of greenhouse gases per kilogram (kg) of corn produced. Results showed large CI variations—from 119 to 407 g CO 2 e kg −1 of corn—due to the farm-level inventory, while the production-weighted average CI for all surveyed farms was 210 g CO 2 e kg −1 , comparable to the national average CI of 204 g CO 2 e kg −1 . The nitrogen fertilizer type applied and rate were identified as key factors contributing most to CI variations at the farm level. The estimated N 2 O emissions from fertilizer and biomass nitrogen inputs to soil accounted for 51% of the overall farm-level CI and therefore need to be better monitored at farm level with high resolution. We concluded that this feedstock-specific, farm-level CI evaluation has the potential to be used to incentivize low-carbon feedstock for biofuel production.

54 ENVIRONMENTAL SCIENCES↗

Model verification: synthetic single pattern simulations using seismic reflection data

During Phase 1 of the Weyburn Project (2000-2004), 4D reflection seismic data were used to map CO2 migration within the Midale reservoir, while an extensive fluid sampling program documented the geochemical evolution triggered by CO2-brine-oilmineral interactions. The aim of this task (3b.11) is to exploit these existing seismic and geochemical data sets, augmented by CO2/H2O injection and HC/H2O production data toward optimizing the reservoir model and thereby improving site characterization and dependent predictions of long-term CO2 storage in the Weyburn-Midale reservoir. Our current project activities have concentrated on completing and testing a stochastic inversion method that will identify reservoir models that optimize agreement between the observed and predicted seismic response. This report describes the results of a validation test that uses synthetic seismic data to identify optimal porosity/permeability distributions within the reservoir. The report partially fulfills deliverable D3: “Model verification: synthetic single pattern simulations” in the project’s statement of work. A future deliverable will describe verification activities related to the geochemical inversion algorithm.

58 GEOSCIENCES↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

This report, Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities , explores ways to automatically identify residential homes with enclosure retrofit opportunities; estimate prospective savings; and perform evaluation, measurement, and verification using interval data from communicating thermostats.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Authentication Protocol for ICS without Encryption

Industrial control systems (ICS) describes the different types of control systems and associated instrumentation, which includes the devices, systems, networks, and controls used to operate and/or automate industrial processes. Depending on the industry, each ICS functions differently and are built to electronically manage tasks efficiently. Historically, industrial plants have included networking, and changes have been made over time without consideration for security. Many ICS devices currently have inadequate security features. Adding encryption in ICS is undesirable because many of the new detection method involves deep packet inspection. Therefore, we propose to develop a method of providing authentication between devices without encrypting the data. This testbed design will allow rapid development and experimentation with Cyber Physical Systems. Modbus connects to a supervisory computer with a Remote Terminal Unit (RTU) in Supervisory Control and Data Acquisition (SCADA) systems. Our project seeks to enhance security in the ICS environment by adding device authentication to the lower levels of the plant floor. This approach was selected as it allows verification of the sender of data from level 1/level 0 devices up to supervisory systems. This addition is desirable as it adds enhanced verification to the integrity of system data without obscuring (via encryption) the data being transmitted across the network. This is important because many ICS systems are real time critical (decryption adds to latency) and many other good security options require deep packet inspection (which encryption completely defeats). To accomplish this, a proof of concept of adding an authentication scheme was designed and will be tested with a common ICS protocol. The setup includes a single serial cable connecting the serial ports on two devices, a Master and a Minion. Authentication will occur in the following methods: - Data layer involving Transport Layer Security/Secure Socket Layer (TLS/SSL); - TCP/IP route implementation; - Key exchange algorithm; - Raspberry Pi programming for authentication. A portion of the setup includes adding Raspberry Pi into the system as the device is handling the authentication for the network traffic. Modbus is the chosen ICS protocol. It is used to transmit signals from instrumentation and control devices back to a main controller or data gathering system. Typically, the device identity is assumed but not verified. For verifying device identity, we constructed a digital signature architecture with TLS. A novel adaptation of this is to use only the digital signature that is provided and not the encryption capability. This allows ICS traffic to flow unobscured while still providing verification for the integrity of the data. Verification of this process will involve adding additional I/O level network devices with spoofed IP addresses and detecting the authenticated versus unauthenticated traffic. Our TLS implementation will have encryption disabled but should still allow for digital signing of data. This will enable our system to distinguish between real end devices and spoofed end devices. This experiment is presently building the test setup. It is focusing on a small setting to identify authenticated and unauthenticated devices on the network. This should allow for scaling to a larger network size after the initial proof of concept. One concern with this scheme is a certificate deployment has a large scale key management. Network size will thus increase the key management task for security. In addition, we believe that further research should be done on exploring the use of this method to defeat man-in-the-middle attacks.

42 ENGINEERING↗

Physical and Flow Properties of Glass Forming Chemicals (V2O5, SnO, SnO2, Cr2O3, FeCr2O4, and ZrSiO4) and Mixtures

For a sustainable nuclear waste vitrification process at the Hanford Tank Waste Treatment and Immobilization Plant (WTP), proper selection and consistent supply of glass-forming chemicals (GFCs) are crucial. Establishing rigorous acceptance criteria for the characterization of GFCs will be required to operate the vitrification facility and to mitigate any processing issues or failures. Low-activity wastes (LAW) are blended with GFCs to form slurry melter feeds and vitrified in a melter. To enhance properties of waste glasses, new chemicals are being introduced to the current GFC mixture (Vienna et al. 2016; Muller et al. 2017, 2019). In this study, three new GFCs were evaluated for enhanced LAW glass formulations: chromium oxide (Cr 2 O 3 ), vanadium oxide (V 2 O 5 ), and stannic oxide (SnO 2 ). These three oxide components are included in enhanced waste glass (EWG) formulations and GFCs with the appropriate physical and flow properties are needed. As a starting point, single metal oxide GFCs: Cr 2 O 3 , V 2 O 5 , and SnO 2 were sourced and tested. To characterize these new individual GFCs and mixtures of GFCs, the industrial bulk characterization consultant, Jenike and Johanson, was employed to measure physical and flow properties of individual GFCs and their mixtures. Pacific Northwest National Laboratory (PNNL) also measured several selected physical properties for data evaluation as a quality assurance step. In addition, PNNL measured physical and rheological properties of slurry melter feeds containing those GFCs. Subsequent data analyses and verification were conducted. The purpose of this report is to assess the applicability of these GFCs for LAW vitrification based on their properties. This report will help understand measured data and evaluate new GFCs for use. Moreover, this report may give useful insights to help troubleshoot any GFC and melter feed transport and mixing issues that arise during processing, leading to a successful cleanup mission at WTP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. In this paper, we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na + sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na + concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.

47 OTHER INSTRUMENTATION↗

DATA RECOVERY EFFORTS AT IDAHO NATIONAL LABORATORY, OAK RIDGE NATIONAL LABORATORY, AND SAVANNAH RIVER NATIONAL LABORATORY

Abstract was already submitted. Could not find the previous number. Would be fine with attaching/update of old number. Abstract Below: Modern nuclear facilities will have significant process monitoring capability for their operators. These systems will also be used for domestic safeguards applications, which has led to research over new diversion-detection algorithms. Curiously missing from these efforts are verification and validation data sets. A tri-laboratory project to locate the existing data sets and recover their data has yielded three major potential sources of data. The first is recovery of the process monitoring data of the Idaho Chemical Processing Plant, which now has a distributable package for algorithm developers. The second data set is extensive sampling and process data from Savannah River National Laboratory’s F- and H-canyon sites. Finally, high fidelity data from the start-up tests at the Barnwell Reprocessing Facility is in recovery. This paper details the data sets and compares their relative attributes.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Novel Physiologically Based Model of Creatinine Renal Disposition to Integrate Current Knowledge of Systems Parameters and Clinical Observations

Creatinine is the most common clinical biomarker of renal function. As a substrate for renal transporters, its secretion is susceptible to inhibition by drugs, resulting in transient increase in serum creatinine and false impression of damage to kidney. Novel physiologically based models for creatinine were developed here and (dis)qualified in a stepwise manner until consistency with clinical data. Data from a matrix of studies were integrated, including systems data (common to all models), proteomics‐informed in vitro – in vivo extrapolation of all relevant transporter clearances, exogenous administration of creatinine (to estimate endogenous synthesis rate), and inhibition of different renal transporters (11 perpetrator drugs considered for qualification during creatinine model development and verification on independent data sets). The proteomics‐informed bottom‐up approach resulted in the underprediction of creatinine renal secretion. Subsequently, creatinine‐trimethoprim clinical data were used to inform key model parameters in a reverse translation manner, highlighting best practices and challenges for middle‐out optimization of mechanistic models.

Scotcher, Daniel↗

A secure measurement unit for an inspection system used in nuclear arms-control verification

Verification of arms control treaties may require information barriers to protect sensitive data acquired during the verification process. These information barriers are commonly implemented in software, but must store and operate on data that are vulnerable to attack and tampering. Here, we present a new Secure Measurement Unit based on a modified pipeline SAR ADC architecture. The idea is to move the information barrier back into the digitization process so that prohibited data is never created. A prototype 65nm CMOS Secure Measurement Unit (SMU) was tested using U-235, U-238, Co-60, Cs-137 and Am-241 sources. Here, the prototype accurately digitized allowable signals while being immune to side-channel attacks on signals within preset forbidden regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of numerical models were developed in parallel to the experimental work. RELAP5-3D models were developed for the salt-cooled PB-AHTR, and for the simulat fluid CIET natural circulation experimental loop. These models are to be validated by the data collected from CIET. COMSOL finite element models were used to predict the temperature and fluid flow distribution in the annular pebble bed core; they were instrumental for design of SETs, and they can be used for code-to-code comparisons with RELAP5-3D. A number of other small SETs, and numerical models were constructed, as needed, in support of this work. The experiments were designed, constructed and performed to meet CAES quality assurance requirements for test planning, implementation, and documentation; equipment calibration and documentation, procurement document control; training and personnel qualification; analysis/modeling software verification and validation; data acquisition/collection and analysis; and peer review.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of critical infrastructure protection using network functions for programmable and decoupled ICS policy enforcement over WAN

Industrial control systems (ICS) represent a major component of our critical infrastructure. With the increasing need for more control and monitoring of such systems, ICS have seen an increase in connectivity to wide area networks (WAN) exposing aging equipment to rapidly evolving cybersecurity threats. Furthermore, the ICS data requires a reliability measure from the networks for critical functions for infrastructure monitoring and control. Especially when remote plant sites are involved such as pipelines, energy distribution networks, and transportation, WAN transport impairments most often provide a best effort delivery with no strict reliability guarantees. Network functions can provide a vendor agnostic, programmable critical infrastructure protection with a single maintenance, policy determination, and reliability assurance surface. A network function (NF) can be utilized for policy enforcement over the communication between remote entities and the main control office. This paper presents the research on transparent integration with existing ICS without disrupting communications, resulting in minimal downtime while decoupling the fast paced evolution of defensive security measures from the upgrade cycle of expensive long term hardware. We report our measurements on the resource requirements and overhead in the network for successful NF insertion under a wide variety of network impairments (network packet delay, reordering, and loss). Our paired NF implementation provides a policy enforcement platform extensible to cover myriad cybersecurity-related communication goals, including packet signing for verification, encryption for data privacy, packet filtering and data diode operation (i.e. protecting against eavesdropping, packet injection, and denial-of-service). Furthermore, bundling communication specifications into packet flows allows for tunability in applying policies as coarse- or fine-grained as the needs of the operator. We report on network function resource requirements in the form of required queue depth and network utilization overhead to inform the decision making against hardware cost constraints.

42 ENGINEERING↗