Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-J-34: Setup Accuracy in Spine SBRT Using CBCT 6D Image Guidance in Comparison with 6D ExacTrac

Purpose Volumetric information of the spine captured on CBCT can potentially improve the accuracy in spine SBRT setup that has been commonly performed through 2D radiographs. This work evaluates the setup accuracy in spine SBRT using 6D CBCT image guidance that recently became available on Varian systems. Methods ExacTrac radiographs have been commonly used for Spine SBRT setup. The setup process involves first positioning patients with lasers followed by localization imaging, registration, and repositioning. Verification images are then taken providing the residual errors (ExacTracRE) before beam on. CBCT verification is also acquired in our institute. The availability of both ExacTrac and CBCT verifications allows a comparison study. 41 verification CBCT of 16 patients were retrospectively registered with the planning CT enabling 6D corrections, giving CBCT residual errors (CBCTRE) which were compared with ExacTracRE. Results The RMS discrepancies between CBCTRE and ExacTracRE are 1.70mm, 1.66mm, 1.56mm in vertical, longitudinal and lateral directions and 0.27°, 0.49°, 0.35° in yaw, roll and pitch respectively. The corresponding mean discrepancies (and standard deviation) are 0.62mm (1.60mm), 0.00mm (1.68mm), −0.80mm (1.36mm) and 0.05° (0.58°), 0.11° (0.48°), −0.16° (0.32°). Of the 41 CBCT, 17 had high-Z surgical implants. No significant difference in ExacTrac-to-CBCT discrepancy was observed between patients with and without the implants. Conclusion Multiple factors can contribute to the discrepancies between CBCT and ExacTrac: 1) the imaging iso-centers of the two systems, while calibrated to coincide, can be different; 2) the ROI used for registration can be different especially if ribs were included in ExacTrac images; 3) small patient motion can occur between the two verification image acquisitions; 4) the algorithms can be different between CBCT (volumetric) and ExacTrac (radiographic) registrations.

60 APPLIED LIFE SCIENCES↗

Passive Tomography for Spent Fuel Verification: Analysis Framework and Instrument Design Study

The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly is being assessed through a collaboration of Support Programs to the International Atomic Energy Agency (IAEA). In the first phase of this study, two safeguards verification objectives have been identified. The first is the independent determination of the number of active pins that are present in the assembly, in the absence of a priori information. The second objective is to provide quantitative measures of pin-by-pin properties, e.g. activity of key isotopes or pin attributes such as cooling time and relative burnup, for the detection of anomalies and/or verification of operator-declared data. The efficacy of GET to meet these two verification objectives will be evaluated across a range of fuel types, burnups, and cooling times, and with a target interrogation time of less than 60 minutes. The evaluation of GET viability for safeguards applications is founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types are used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. Instrument response data are processed by a variety of tomographic-reconstruction and image-processing methods, and scoring metrics specific to each of the verification objectives are defined and used to evaluate the performance of the methods. This paper will provide a description of the analysis framework and evaluation metrics, example performance-prediction results, and describe the design of a “universal” GET instrument intended to support the full range of verification scenarios envisioned by the IAEA.

spent nuclear fuel assemblies, partial defect veri↗

Study of techniques for redundancy verification without disrupting systems, phases 1-3

The problem of verifying the operational integrity of redundant equipment and the impact of a requirement for verification on such equipment are considered. Redundant circuits are examined and the characteristics which determine adaptability to verification are identified. Mutually exclusive and exhaustive categories for verification approaches are established. The range of applicability of these techniques is defined in terms of signal characteristics and redundancy features. Verification approaches are discussed and a methodology for the design of redundancy verification is developed. A case study is presented which involves the design of a verification system for a hypothetical communications system. Design criteria for redundant equipment are presented. Recommendations for the development of technological areas pertinent to the goal of increased verification capabilities are given.

Source record↗

SU-E-T-50: A Multi-Institutional Study of Independent Dose Verification Software Program for Lung SBRT

Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity-region. The tolerance level (TL) of the secondary check using the independent dose verification may be variable in lung SBRT plans. We conducted a multi-institutional study to evaluate the tolerance level of lung SBRT plans shown in the AAPM TG114. Methods: Five institutes in Japan participated in this study. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. Analytical Anisotropic Algorithm (AAA), Pencil Beam Convolution with modified Batho-method (PBC-B) and Adaptive Convolve (AC) were used for lung SBRT planning. A measurement using an ion-chamber was performed in a heterogeneous phantom to compare doses from the three different algorithms and the SMU to the measured dose. In addition to it, a retrospective analysis using clinical lung SBRT plans (547 beams from 77 patients) was conducted to evaluate the confidence limit (CL, Average±2SD) in dose between the three algorithms and the SMU. Results: Compared to the measurement, the AAA showed the larger systematic dose error of 2.9±3.2% than PBC-B and AC. The Clarkson-based SMU showed larger error of 5.8±3.8%. The CLs for clinical plans were 7.7±6.0 % (AAA), 5.3±3.3 % (AC), 5.7±3.4 % (PBC -B), respectively. Conclusion: The TLs from the CLs were evaluated. A Clarkson-based system shows a large systematic variation because of inhomogeneous correction. The AAA showed a significant variation. Thus, we must consider the difference of inhomogeneous correction as well as the dependence of dose calculation engine.

60 APPLIED LIFE SCIENCES↗

SU-F-T-268: A Feasibility Study of Independent Dose Verification for Vero4DRT

Purpose: Vero4DRT (Mitsubishi Heavy Industries Ltd.) has been released for a few years. The treatment planning system (TPS) of Vero4DRT is dedicated, so the measurement is the only method of dose verification. There have been no reports of independent dose verification using Clarksonbased algorithm for Vero4DRT. An independent dose verification software program of the general-purpose linac using a modified Clarkson-based algorithm was modified for Vero4DRT. In this study, we evaluated the accuracy of independent dose verification program and the feasibility of the secondary check for Vero4DRT. Methods: iPlan (Brainlab AG) was used as the TPS. PencilBeam Convolution was used for dose calculation algorithm of IMRT and X-ray Voxel Monte Carlo was used for the others. Simple MU Analysis (SMU, Triangle Products, Japan) was used as the independent dose verification software program in which CT-based dose calculation was performed using a modified Clarkson-based algorithm. In this study, 120 patients’ treatment plans were collected in our institute. The treatments were performed using the conventional irradiation for lung and prostate, SBRT for lung and Step and shoot IMRT for prostate. Comparison in dose between the TPS and the SMU was done and confidence limits (CLs, Mean ± 2SD %) were compared to those from the general-purpose linac. Results: As the results of the CLs, the conventional irradiation (lung, prostate), SBRT (lung) and IMRT (prostate) show 2.2 ± 3.5% (CL of the general-purpose linac: 2.4 ± 5.3%), 1.1 ± 1.7% (−0.3 ± 2.0%), 4.8 ± 3.7% (5.4 ± 5.3%) and −0.5 ± 2.5% (−0.1 ± 3.6%), respectively. The CLs for Vero4DRT show similar results to that for the general-purpose linac. Conclusion: The independent dose verification for the new linac is clinically available as a secondary check and we performed the check with the similar tolerance level of the general-purpose linac. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

Open-source MFIX-DEM software for gas-solids flows: Part II — Validation studies

With rapid advancements in computer hardware and numerical algorithms, computational fluid dynamics (CFD) has been increasingly employed as a useful tool for investigating the complex hydrodynamics inherent in multiphase flows. An important step during the development of a CFD model and prior to its application is conducting careful and comprehensive verification and validation studies. Accordingly, efforts to verify and validate the open-source MFIX-DEM software, which can be used for simulating the gas–solids flow using an Eulerian reference frame for the continuum fluid and a Lagrangian discrete framework (Discrete Element Method) for the particles, have been made at the National Energy Technology Laboratory (NETL). In part I of this paper, extensive verification studies were presented and in this part, detailed validation studies of MFIX-DEM are presented. A series of test cases covering a range of gas–solids flow applications were conducted. In particular the numerical results for the random packing of a binary particle mixture, the repose angle of a sandpile formed during a side charge process, velocity, granular temperature, and voidage profiles from a bounded granular shear flow, lateral voidage and velocity profiles from a monodisperse bubbling fluidized bed, lateral velocity profiles from a spouted bed, and the dynamics of segregation of a binary mixture in a bubbling bed were compared with available experimental data, and in some instances with empirical correlations. In addition, sensitivity studies were conducted for various parameters to quantify the error in the numerical simulation.

42 ENGINEERING↗

Three-dimensional continuum point cloud method for large deformation and its verification

This study presents a strong form based meshfree collocation method, which is named Continuum Point Cloud Method, to solve nonlinear field equations derived from classical mechanics for deformed bodies in three-dimensional Euclidean space. The method and its implementation are benchmarked against a nonlinear vector field using manufactured solutions. The analysis of mechanical fields firstly focuses on the study of St. Venant Kirchhoff and compressible neo-Hookean materials. Results for various initial boundary value problems are presented, including benchmark cases involving unidirectional tension and simple shear. Subsequently, the study concludes with an analysis of a displacement-controlled simulation of a compressible neo-Hookean material, specifically a bar that is pulled to 50% of its original length and rotated 90°. The pure tension case yields a 1.5% error in displacement between computed and expected values and a combined tension and torsion loading case provides further insight into material behavior under complex loading conditions. The resulting normal axial and transverse stress-strain curves are also presented. Lastly, the consistency and robustness of the proposed nonlinear numerical schemes are successfully demonstrated through various numerical experiments.

Compressible neo-Hookean materials↗

Thermo-acoustoelastic effect of Rayleigh wave: Theory and experimental verification

Previous studies showed that the thermally-induced ultrasonic bulk wave velocity change could be used to measure acoustoelastic coefficients and third-order elastic constants of elastic materials. This method is naturally immune from the ambient temperature effect and has improved sensitivity and a simpler test setup than the conventional acoustoelastic test. However, Rayleigh wave is preferred for thick components or structures with only one accessible surface. In this work, the thermo-hyperelastic constitutive equation, along with acoustoelastic theory, is used to derive the expression of the thermo-acoustoelastic coefficient (TAEC) of Rayleigh wave. The numerical relationship between the TAEC of Rayleigh wave and Murnaghan constants ( l, m and n ) are given for common metals. Further, the TAEC expressions for Rayleigh wave and shear wave are similar, and both are dominated by the constant m . The TAEC of Rayleigh wave was measured on an aluminum 6061 specimen using the thermal modulation experiment in a temperature range of 22 ~ 35°C. The measured TAEC shows good agreement with the theoretical calculation. Then the third-order elastic constants were calculated based on TAECs of bulk waves and Rayleigh wave.

42 ENGINEERING↗

Space Shuttle Tail Service Mast Concept Verification

Design studies and analyses were performed to describe the loads and dynamics of the space shuttle tail service masts (TSMs). Of particular interest are the motion and interaction of the umbilical carrier plate, lanyard system, vacuum jacketed hoses, latches, links, and masthead. A development test rig was designed and fabricated to obtain experimental data. The test program is designed to (1) verify the theoretical dynamics calculations, (2) prove the soundness of design concepts, and (3) elucidate problem areas (if any) in the design of mechanisms and structural components. Design, fabrication, and initiation of TSM development testing at Kennedy Space Center are described.

Uda, R. T.↗

Hybrid Enrichment Verification Array: Module Characterization Studies

The work presented in this report is focused on the characterization and refinement of the Hybrid Enrichment Verification Array (HEVA) approach, which combines the traditional 186-keV 235 U signature with high-energy prompt gamma rays from neutron capture in the detector and surrounding collimator material, to determine the relative enrichment and 235 U mass of the cylinder. The design of the HEVA modules (hardware and software) deployed in the current field trial builds on over seven years of study and evolution by PNNL, and consists of a ø3''×3'' NaI(Tl) scintillator coupled to an Osprey digital multi-channel analyzer tube base from Canberra. The core of the HEVA methodology, the high-energy prompt gamma-ray signature, serves as an indirect method for the measurement of total neutron emission from the cylinder. A method for measuring the intrinsic efficiency of this “non-traditional” neutron signature and the results from a benchmark experiment are presented. Also discussed are potential perturbing effects on the non-traditional signature, including short-lived activation of materials in the HEVA module. Modeling and empirical results are presented to demonstrate that such effects are expected to be negligible for the envisioned implementation scenario. In comparison to previous versions, the new design boosts the high-energy prompt gamma-ray signature, provides more flexible and effective collimation, and improves count-rate management via commercially available pulse-processing electronics with a special modification prompted by PNNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Possible Use of Information Barriers for future Biological Weapons Verification Regimes

This report describes a path forward for implementing information barriers in a future generic biological arms-control verification regime. Information barriers have become a staple of discussion in the area of arms control verification approaches for nuclear weapons and components. Information barriers when used with a measurement system allow for the determination that an item has sensitive characteristics without releasing any of the sensitive information. Over the last 15 years the United States (with the Russian Federation) has led on the development of information barriers in the area of the verification of nuclear weapons and nuclear components. The work of the US and the Russian Federation has prompted other states (e.g., UK and Norway) to consider the merits of information barriers for possible verification regimes. In the context of a biological weapons control verification regime, the dual-use nature of the biotechnology will require protection of sensitive information while allowing for the verification of treaty commitments. A major question that has arisen is whether - in a biological weapons verification regime - the presence or absence of a weapon pathogen can be determined without revealing any information about possible sensitive or proprietary information contained in the genetic materials being declared under a verification regime. This study indicates that a verification regime could be constructed using a small number of pathogens that spans the range of known biological weapons agents. Since the number of possible pathogens is small it is possible and prudent to treat these pathogens as analogies to attributes in a nuclear verification regime. This study has determined that there may be some information that needs to be protected in a biological weapons control verification regime. To protect this information, the study concludes that the Lawrence Livermore Microbial Detection Array may be a suitable technology for the detection of the genetic information associated with the various pathogens. In addition, it has been determined that a suitable information barrier could be applied to this technology when the verification regime has been defined. Finally, the report posits a path forward for additional development of information barriers in a biological weapons verification regime. This path forward has shown that a new analysis approach coined as Information Loss Analysis might need to be pursued so that a numerical understanding of how information can be lost in specific measurement systems can be achieved.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Unmanned Aircraft Systems Detect and Avoid System: End-to-End Verification and Validation Simulation Study of Minimum Operations Performance Standards for Integrating Unmanned Aircraft into the National Airspace System

As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.

Ghatas, Rania W.↗

The Effects of Severity of Losses of Well Clear on Minimum Operations Performance Standards End-To-End Verification and Validation Simulation Study for Integrating Unmanned Aircraft Systems into the National Airspace System Using Detect and Avoid Systems

As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of “eyes in the sky” due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA Special Committee(SC)-228’s proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.

Ghatas, Rania W.↗

SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT

Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conducted in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.

60 APPLIED LIFE SCIENCES↗

CFD-DEM solution verification: Fixed-bed studies

Fixed (frozen) particle configurations are used to study CFD-DEM convergence behavior in the limit of infinite grid resolution. A filtering scheme based on solving a diffusion equation, i.e., a Gaussian kernel, is used to interpolate particle information to the continuum grid, free of cell size limitations. A regression method is used for Richardson extrapolation of the discrete solutions to the grid-free solution. The regression method is shown to predict accurate extrapolation curves in the presence of the observed oscillatory convergence behavior. The extrapolation curve is used to complete the solution verification process by quantifying the numerical uncertainty present in the calculations. Several numerical and model parameters are studied including the spatial discretization method, the kernel width and the mean drag law. Here, a manageable level of discretization error is found with relative discretization errors generally <4%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification of the LOTUS code with C5G7 benchmark

In this study, the verification of the neutron transport code LOTUS through the well-known C5G7 benchmark is performed. LOTUS uses the current coupled collision probability method with the expansion of the flux by orthogonal polynomials (CCCPO) for the solution of the neutron transport equation. The expansion of the flux by orthogonal polynomials allows one to avoid discretization of the calculation regions and significantly decreases the simulation time. The results of the LOTUS calculations are compared with the results of the reference OpenMC Monte Carlo simulations. The results of the comparison demonstrate almost perfect agreement with Monte-Carlo for the second order of the flux expansion. Even though the results obtained in the presented study agree well with the results of reference Monte Carlo calculations, further investigations are necessary for a better understanding of the stability and limitations of the code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AZTRAN and AZKIND verification with a BWR study case

The AZTLAN Platform project is a national initiative led by the National Institute of Nuclear Research which gather the main public institutions of higher education in Mexico: the National Polytechnic Institute, the National Autonomous University of Mexico and the Autonomous Metropolitan University. It consists in the development of a modeling platform for the analysis and design of nuclear reactors. This project aims to modernize, improve and integrate the neutronic, thermohydraulics and thermomechanical codes, developed in the national institutions, in a platform integrated and developed by Mexican experts. The development of AZTLAN Platform is divided technically into four working groups: neutronics, thermohydraulics, coupling and uncertainty analysis, and users group. The present work is the result of the activities of the Users Group focused on the follow-up, testing and use of the different codes (modules) being developed under the AZTLAN project; with the objective of providing feedback and to suggest development priorities to the team of developers, as well as to promote collaboration and synergy between the participating institutions. In particular, in this work, the AZTRAN and the AZKIND modules were verified and tested against the results of well-known codes of the nuclear industry for boiling water reactor (BWR) models. AZTRAN is a 3D transport code which solves numerically the multi-group time independent neutron transport equation in Cartesian geometry, based on the discrete ordinates (SN) method and the RTN-0 nodal scheme. AZKIND is a 3D diffusion code that solves numerically the time dependent neutron diffusion equations in Cartesian geometry, based on a Galerkin Finite Element Method using the RTN-0 polynomial nodal approximation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-602: Patient-Specific Online Dose Verification Based On Transmission Detector Measurements

Purpose: Intensity modulated radiotherapy requires a comprehensive quality assurance program in general and ideally independent verification of dose delivery. Since conventional 2D detector arrays allow only pre-treatment verification, there is a debate concerning the need of online dose verification. This study presents the clinical performance, including dosimetric plan verification in 2D as well as in 3D and the error detection abilities of a new transmission detector (TD) for online dose verification of 6MV photon beam. Methods: To validate the dosimetric performance of the new device, dose reconstruction based on TD measurements were compared to a conventional pre-treatment verification method (reference) and treatment planning system (TPS) for 18 IMRT and VMAT treatment plans. Furthermore, dose reconstruction inside the patient based on TD read-out was evaluated by comparing various dose volume indices and 3D gamma evaluations against independent dose computation and TPS. To investigate the sensitivity of the new device, different types of systematic and random errors for leaf positions and linac output were introduced in IMRT treatment sequences. Results: The 2D gamma index evaluation of transmission detector based dose reconstruction showed an excellent agreement for all IMRT and VMAT plans compared to reference measurements (99.3±1.2)% and TPS (99.1±0.7)%. Good agreement was also obtained for 3D dose reconstruction based on TD read-out compared to dose computation (mean gamma value of PTV = 0.27±0.04). Only a minimal dose underestimation within the target volume was observed when analyzing DVH indices (<1%). Positional errors in leaf banks larger than 1mm and errors in linac output larger than 2% could clearly identified with the TD. Conclusion: Since 2D and 3D evaluations for all IMRT and VMAT treatment plans were in excellent agreement with reference measurements and dose computation, the new TD is suitable to qualify for routine treatment plan verification. Funding Support, Disclosures, and Conflict of Interest: COIs: Frank Lohr: Elekta: research grant, travel grants, teaching honoraria IBA: research grant, travel grants, teaching honoraria, advisory board C-Rad: board honoraria, travel grants Frederik Wenz: Elekta: research grant, teaching honoraria, consultant, advisory board Zeiss: research grant, teaching honoraria, patent Hansjoerg Wertz: Elekta: research grant, teaching honoraria IBA: research grant.

61 RADIATION PROTECTION AND DOSIMETRY↗