Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Test Capability Enhancements to the NASA Langley 8-Foot High Temperature Tunnel

The NASA Langley 8-Foot High Temperature Tunnel produces true enthalpy environments simulating flight from Mach 4 to Mach 7, primarily for airbreathing propulsion and aerothermal/thermo-structural testing. Flow conditions are achieved through a methane-air heater and nozzles producing aerodynamic Mach numbers of 4, 5 or 7 and have exit diameters of 8 feet or 4.5 feet. The 12-ft long free-jet test section, housed inside a 26-ft vacuum sphere, accommodates large test articles. Recently, the facility underwent significant upgrades to support hydrocarbon fueled scramjet engine testing and to expand flight simulation capability. The upgrades were required to meet engine system development and flight clearance verification requirements originally defined by the joint NASA-Air Force X-43C Hypersonic Flight Demonstrator Project and now the Air Force X-51A Program. Enhancements to the 8-Ft. HTT were made in four areas: 1) hydrocarbon fuel delivery; 2) flight simulation capability; 3) controls and communication; and 4) data acquisition/processing. The upgrades include the addition of systems to supply ethylene and liquid JP-7 to test articles; a Mach 5 nozzle with dynamic pressure simulation capability up to 3200 psf, the addition of a real-time model angle-of-attack system; a new programmable logic controller sub-system to improve process controls and communication with model controls; the addition of MIL-STD-1553B and high speed data acquisition systems and a classified data processing environment. These additions represent a significant increase to the already unique test capability and flexibility of the facility, and complement the existing array of test support hardware such as a model injection system, radiant heaters, six-component force measurement system, and optical flow field visualization hardware. The new systems support complex test programs that require sophisticated test sequences and precise management of process fluids. Furthermore, the new systems, such as the real-time angle of attack system and the new programmable logic controller enhance the test efficiency of the facility. The motivation for the upgrades and the expanded capabilities is described here.

Harvin, S. F.↗

Stroboscopic Vision as a Treatment for Space Motion Sickness

Results obtained from space flight indicate that most space crews will experience some symptoms of motion sickness causing significant impact on the operational objectives that must be accomplished to assure mission success. Based on the initial work of Melvill Jones we have evaluated stroboscopic vision as a method of preventing motion sickness. Given that the data presented by professor Melvill Jones were primarily post hoc results following a study not designed to investigate motion sickness, it is unclear how motion sickness results were actually determined. Building on these original results, we undertook a three part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness using: (1) visual field reversal, (2) Reading while riding in a car (with or without external vision present), and (3) making large pitch head movements during parabolic flight.

Reschke, Millard F.↗

Stroboscopic Vision as a Treatment for Retinal Slip Induced Motion Sickness

Motion sickness in the general population is a significant problem driven by the increasingly more sophisticated modes of transportation, visual displays, and virtual reality environments. It is important to investigate non-pharmacological alternatives for the prevention of motion sickness for individuals who cannot tolerate the available anti-motion sickness drugs, or who are precluded from medication because of different operational environments. Based on the initial work of Melvill Jones, in which post hoc results indicated that motion sickness symptoms were prevented during visual reversal testing when stroboscopic vision was used to prevent retinal slip, we have evaluated stroboscopic vision as a method of preventing motion sickness in a number of different environments. Specifically, we have undertaken a five part study that was designed to investigate the effect of stroboscopic vision (either with a strobe light or LCD shutter glasses) on motion sickness while: (1) using visual field reversal, (2) reading while riding in a car (with or without external vision present), (3) making large pitch head movements during parabolic flight, (4) during exposure to rough seas in a small boat, and (5) seated and reading in the cabin area of a UH60 Black Hawk Helicopter during 20 min of provocative flight patterns.

Reschke, M. F.↗

Medical Monitoring during Short Radius Centrifugation in Bed-rested Subjects

The artificial gravity pilot project was designed to investigate the efficacy of daily exposure to a Gz acceleration gradient for counteracting the physiologic decrements induced by prolonged bed rest. A short radius centrifuge was used to produce a Gz gradient such that 1 g was applied at the level of the subject s heart and 2.5 g at the feet. For inclusion in the study, subjects were required to complete a 75-minute screening spin on the centrifuge. During the study, each active treatment subject was scheduled for a 60-minute spin each day for 20 consecutive days. During centrifugation, subjects were continuously monitored by a physician for signs and symptoms of pre-syncope, motion sickness, arrhythmias, joint/muscle pain and any other unanticipated problems. The physician was also present to provide emergency care in the case of a medical emergency. Cameras mounted on the centrifuge were used to provide a means of observing the subject s face and torso. Audio communication was continuously maintained. Other monitoring tools included two-lead EKG tracings, pulse oximetry, intermittent sphygmomanometer readings, lights in the peripheral visual field, and continuous blood pressure readout from a tonometry device. Thirty screening runs were attempted using twenty-seven subjects. Seven of these runs were terminated early for symptoms of pre-syncope, motion sickness, or GI distress. A total of eight subjects completed the active treatment arm of the study. Of the 160 centrifuge runs that were scheduled for these eight treatment subjects, 152 were completed, seven were terminated early, and one was not attempted. Of the seven early terminations, four were related to symptoms of pre-syncope, one to leg pain, one to GI discomfort, and one to equipment failure. Three terminations for adverse symptoms occurred on the first treatment day. Three terminations occurred on day nineteen of treatment and within 24 hours after scheduled soleus and quadriceps muscle biopsies. We have summarized the relative usefulness of the information obtained by the various monitoring modalities in making a decision to terminate a centrifuge run. The video and audio communication information was essential to the decision-making process. Heart rate and EKG tracings are considered valuable, even though no spins were terminated due to significant arrhythmias. The tonometer device was generally not reliable in this application. Our observations suggest that subjects may be less tolerant of centrifugation just after starting bed rest and after invasive procedures.

Reinertson, Randal↗

Prospective Observational Study of Ocular Health in ISS Crews - The Ocular Health Study

The Visual Impairment Intracranial Pressure (VIIP) syndrome is currently NASA's number one human space flight risk. The syndrome, which is related to microgravity exposure, manifests with changes in visual acuity (hyperopic shifts, scotomas), changes in eye structure (optic disc edema, choroidal folds, cotton wool spots, globe flattening, and dilated optic nerve sheaths), and in some cases with documented increased intracranial pressure (ICP) postflight. While the eye appears to be the main affected end organ of this syndrome, the ocular effects are thought to be related to underlying changes in the vascular system and the central nervous system. The leading hypotheses for the development of VIIP involve microgravity-induced head-ward fluid shifts along with a loss of gravity-assisted drainage of venous blood from the brain, leading to cephalic congestion, decreased CSF resorption and increased ICP. Since 70% of ISS crewmembers have manifested clinical signs or symptoms of the VIIP syndrome, it is assumed that the majority have some degree of ICP elevation in-flight compared to the ground. Prolonged elevations of ICP can cause long-term reduced visual acuity and loss of peripheral visual fields, and have been reported to cause mild cognitive impairment in the analog terrestrial population of Idiopathic Intracranial Hypertension (IIH). These potentially irreversible health consequences underscore the importance of identifying the factors that lead to this syndrome and mitigating them.

Otto, C.↗

The Visual Impairment Intracranial Pressure Syndrome in Long Duration NASA Astronauts: An Integrated Approach

The Visual Impairment Intracranial Pressure (VIIP) syndrome is currently NASA's number one human space flight risk. The syndrome, which is related to microgravity exposure, manifests with changes in visual acuity (hyperopic shifts, scotomas), changes in eye structure (optic disc edema, choroidal folds, cotton wool spots, globe flattening, and distended optic nerve sheaths). In some cases, elevated cerebrospinal fluid pressure has been documented postflight reflecting increased intracranial pressure (ICP). While the eye appears to be the main affected end organ of this syndrome, the ocular affects are thought to be related to the effect of cephalad fluid shift on the vascular system and the central nervous system. The leading hypotheses for the development of VIIP involve microgravity induced head-ward fluid shifts along with a loss of gravity-assisted drainage of venous blood from the brain, both leading to cephalic congestion and increased ICP. Although not all crewmembers have manifested clinical signs or symptoms of the VIIP syndrome, it is assumed that all astronauts exposed to microgravity have some degree of ICP elevation in-flight. Prolonged elevations of ICP can cause long-term reduced visual acuity and loss of peripheral visual fields, and has been reported to cause mild cognitive impairment in the analog terrestrial population of Idiopathic Intracranial Hypertension (IIH). These potentially irreversible health consequences underscore the importance of identifying the factors that lead to this syndrome and mitigating them.

Otto, C. A.↗

Comparison of Structural and Functional Ocular Outcomes Between 14- and 70 Day Bed Rest

Purpose: To compare structural and functional ocular outcomes in healthy human subjects undergoing 14- and/or 70-day head-down-tilt bed rest (HDTBR). We hypothesized the amount of HDTBR-induced ocular changes be affected by the HDTBR duration. Methods: The studies were conducted at the NASA Flight Analogs Research Unit, The University of Texas Medical Branch at Galveston, Galveston, TX. Participants were selected using NASA standard screening procedures. Standardized NASA screening procedures and bed rest conditions (e.g., strict sleep-wake cycle, standardized diet, continuous video monitoring) were implemented in both studies. Participants maintained a 6deg HDTBR position for 14 and/or 70 consecutive days and did not engage in exercise. Weekly ophthalmological examinations were conducted in the sitting (pre/post-bed rest only) and HDT positions. Ocular outcomes of interest included: near best-corrected visual acuity (BCVA); spherical equivalent, as determined by cycloplegic autorefraction; Goldmann applanation tonometry and iCare (Icare Finland Oy, Espoo, Finland) intraocular pressure (IOP) measurement; color vision; red dot test; modified Amsler grid test; confrontational visual field; stereoscopic color fundus photography; Spectralis OCT (Heidelberg Engineering, GmbH, Heidelberg, Germany) retinal nerve fiber layer thickness (RNFLT), peripapillary and macular retinal thicknesses. Mixed-effects linear models were used to compare pre- and post-HDTBR observations between 14- and 70-day HDTBR for our continuously scaled outcomes.

Cromwell, R. L.↗

Optimizing Screening for Preventable Blindness With Head-Mounted Visual Assessment Technology

Age-related macular degeneration (AMD) is a leading cause of blindness and is diagnosed as early-stage or late-stage. Early-stage AMD is usually asymptomatic and entails pigmentary changes of the retina (Ayoub & Patel, 2009). As the disorder progresses, there are atrophic or neovascular changes that distort vision, especially the central visual field (Ayoub & Patel, 2009). There are several genetic and non-genetic risk factors for AMD and no proven therapy to slow or reverse late-stage atrophic AMD, while anti-VEGF has effectively treated late-stage neovascular AMD. Several genes of interest have also been investigated thoroughly thus far in their connection to AMD and the CFH and ARMS2 genes have shown promise in understanding the genetic basis of the disorder (Awh et al., 2013). There are other epigenetic and environmental factors as well including smoking and low antioxidant levels (Cano et al., 2010). Ongoing investigations include antioxidant supplementation and a smoking cessation regimen to reverse early-stage AMD (Cano et al., 2010). Progress in treating AMD as a disorder across its varied stages requires newer therapeutics along with a more detailed understanding of the genetic and cellular pathways of pathophysiology is needed to better counter this prevalent disorder of the eye.

age-related macular degeneration↗

Distributed Parallel Particle Advection using Work Requesting

Particle advection is an important vector field visualization technique that is difficult to apply to very large data sets in a distributed setting due to scalability limitations in existing algorithms. In this paper, we report on several experiments using work requesting dynamic scheduling which achieves balanced work distribution on arbitrary problems with minimal communication overhead. We present a corresponding prototype implementation, provide and analyze benchmark results, and compare our results to an existing algorithm.

97 MATHEMATICS AND COMPUTING↗

Methods of using (1S,3S)-3-amino-4-difluoromethylenyl-1-cyclopentanoic acid

(1S,3S)-3-amino-4-difluoromethylenyl-1-cyclopentanoic acid also known as CPP-115 or its pharmaceutically acceptable salts can be used to treat addiction and neurological disorders such as epilepsy without side effects such as visual field defects caused by vigabatrin (Sabril).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance-Portable Particle Advection with VTK-m

Particle advection is the fundamental kernel behind most vector field visualization methods. Yet, the efficient parallel computation of large amounts of particle traces remains challenging. This is exacerbated by the variety of hardware trends in today's HPC arena, including increasing core counts in classical CPUs, many-core designs such as the Intel Xeon Phi, and massively parallel GPUs. The dedicated optimization of a particle advection kernel for each individual target architecture is both time-consuming and error prone. In this paper, we propose a performance-portable algorithm for particle advection. Our algorithm is based on the recently introduced VTK-m system and chiefly relies on its device adapter abstraction. We demonstrate the general portability of our implementation across a wide variety of hardware. Finally, our evaluation shows that our hardware-agnostic algorithm has comparable performance to hardware-specific algorithms.

Pugmire, Dave↗

A study of methods to predict and measure the transmission of sound through the walls of light aircraft. A survey of techniques for visualization of noise fields

A survey of the most widely used methods for visualizing acoustic phenomena is presented. Emphasis is placed on acoustic processes in the audible frequencies. Many visual problems are analyzed on computer graphic systems. A brief description of the current technology in computer graphics is included. The visualization technique survey will serve as basis for recommending an optimum scheme for displaying acoustic fields on computer graphic systems.

Marshall, S. E.↗

Flow visualization and flow field measurements of a 1/12 scale tilt rotor aircraft in hover

The results are given of flow visualization studies and inflow velocity field measurements performed on a 1/12 scale model of the XV-15 tilt rotor aircraft in the hover mode. The complex recirculating flow due to the rotor-wake-body interactions characteristic of tilt rotors was studied visually using neutrally buoyant soap bubbles and quantitatively using hot wire anemometry. Still and video photography were used to record the flow patterns. Analysis of the photos and video provided information on the physical dimensions of the recirculating fountain flow and on details of the flow including the relative unsteadiness and turbulence characteristics of the flow. Recirculating flows were also observed along the length of the fuselage. Hot wire anemometry results indicate that the wing under the rotor acts to obstruct the inflow causing a deficit in the inflow velocities over the inboard region of the model. Hot wire anemometry also shows that the turbulence intensities in the inflow are much higher in the recirculating fountain reingestion zone.

Coffen, Charles D.↗

Flow visualization and flow field measurements of a 1/12 scale tilt rotor aircraft in hover

The results are given of flow visualization studies and inflow velocity field measurements performed on a 1/12 scale model of the XV-15 tilt rotor aircraft in the hover mode. The complex recirculating flow due to the rotor-wake-body interactions characteristic of tilt rotors was studied visually using neutrally buoyant soap bubbles and quantitatively using hot wire anemometry. Still and video photography were used to record the flow patterns. Analysis of the photos and video provided information on the physical dimensions of the recirculating fountain flow and on details of the flow including the relative unsteadiness and turbulence characteristics of the flow. Recirculating flows were also observed along the length of the fuselage. Hot wire anemometry results indicate that the wing under the rotor acts to obstruct the inflow causing a deficit in the inflow velocities over the inboard region of the model. Hot wire anemometry also shows that the turbulence intensities in the inflow are much higher in the recirculating fountain reingestion zone.

Coffen, Charles D.↗

Flow visualization methods for field test verification of CFD analysis of an open gloveport

Anemometer readings alone cannot provide a complete picture of air flow patterns at an open gloveport. Having a means to visualize air flow for field tests in general provides greater insight by indicating direction in addition to the magnitude of the air flow velocities in the region of interest. Furthermore, flow visualization is essential for Computational Fluid Dynamics (CFD) verification, where important modeling assumptions play a significant role in analyzing the chaotic nature of low-velocity air flow. A good example is shown Figure 1, where an unexpected vortex pattern occurred during a field test that could not have been measured relying only on anemometer readings. Here by, observing and measuring the patterns of the smoke flowing into the gloveport allowed the CFD model to be appropriately updated to match the actual flow velocities in both magnitude and direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualizing heterogeneous dipole fields by terahertz light coupling in individual nano-junctions

The challenge underlying superconducting quantum computing is to remove materials bottleneck for highly coherent quantum devices. The nonuniformity and complex structural components in the underlying quantum circuits often lead to local electric field concentration, charge scattering, dissipation and ultimately decoherence. Here we visualize interface dipole heterogeneous distribution of individual Al/AlO$_{x}$/Al junctions employed in transmon qubits by broadband terahertz scanning near-field microscopy that enables the non-destructive and contactless identification of defective boundaries in nano-junctions at an extremely precise nanoscale level. Our THz nano-imaging tool reveals an asymmetry across the junction in electromagnetic wave-junction coupling response that manifests as hot (high intensity) vs cold (low intensity) spots in the spatial electrical field structures and correlates with defected boundaries from the multi-angle deposition processes in Josephson junction fabrication inside qubit devices. The demonstrated local electromagnetic scattering method offers high sensitivity, allowing for reliable device defect detection in the pursuit of improved quantum circuit fabrication for ultimately optimizing coherence times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unique wide field of view visual simulation

Visual simulations are required to support investigations of the man-machine aspects of helicopter nap-of-the-earth flight. The visual simulation requirements are discussed vis-a-vis available technology. A wide field of view of the world outside the cockpit is necessary to provide adequate visual cues to the pilot. A unique design is described employing three TV monitors, collimating lenses, and electronics to selectively display a wide field of view without the use of a costly wide angle optical probe.

Niemela, J.↗

Application of the wide-field shadowgraph technique to rotor wake visualization

The wide field shadowgraph technique is reviewed along with its application to the visualization of rotor wakes. In particular, current experimental methods and data reduction requirements are discussed. Sample shadowgraphs are presented. These include shadowgraphs of model-scale helicopter main rotors and tilt rotors, and full scale tail rotors, both in hover and in forward flight.

Norman, Thomas R.↗