At least 199 records · Page 11

Evaluation of Geologic Carbon Storage Resource Estimates (SREs) of Cambrian Ordovician Units within the CarbonSAFE Prefeasibility Study Region Subtasks 4.2 and 4.3 – Topical Report

This report by the Indiana Geological & Water Survey (IGWS) assessed the storage resource estimate (SRE) of Cambrian-Ordovician stratigraphic units located within the CarbonSAFE prefeasibility area within the Illinois Basin. A comprehensive data set of wireline logs and petrophysical information was used. These data include core analysis for porosity and permeability, and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for four potential storage reservoirs (Upper Ordovician Trenton Limestone/Black River Group, Middle Ordovician St. Peter Sandstone, Lower Ordovician and Upper Cambrian Knox Supergroup, including a separate assessment for the lower Knox Potosi Dolomite. The resultant SREs volumes are displayed using georeferenced maps and boxplots. The latter allow for comparing data statistics (mean values and variability) between five methods employed for the SRE calculations. Differences observed in SRE results from the five methods are mainly attributable to differences in the data used for porosity in each method. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Optimizing tertiary storage organization and access for spatio-temporal datasets

We address in this paper data management techniques for efficiently retrieving requested subsets of large datasets stored on mass storage devices. This problem represents a major bottleneck that can negate the benefits of fast networks, because the time to access a subset from a large dataset stored on a mass storage system is much greater that the time to transmit that subset over a network. This paper focuses on very large spatial and temporal datasets generated by simulation programs in the area of climate modeling, but the techniques developed can be applied to other applications that deal with large multidimensional datasets. The main requirement we have addressed is the efficient access of subsets of information contained within much larger datasets, for the purpose of analysis and interactive visualization. We have developed data partitioning techniques that partition datasets into 'clusters' based on analysis of data access patterns and storage device characteristics. The goal is to minimize the number of clusters read from mass storage systems when subsets are requested. We emphasize in this paper proposed enhancements to current storage server protocols to permit control over physical placement of data on storage devices. We also discuss in some detail the aspects of the interface between the application programs and the mass storage system, as well as a workbench to help scientists to design the best reorganization of a dataset for anticipated access patterns.

Chen, Ling Tony↗

Habituation and adaptation of the vestibuloocular reflex: a model of differential control by the vestibulocerebellum

We habituated the dominant time constant of the horizontal vestibuloocular reflex (VOR) of rhesus and cynomolgus monkeys by repeated testing with steps of velocity about a vertical axis and adapted the gain of the VOR by altering visual input with magnifying and reducing lenses. After baseline values were established, the nodulus and ventral uvula of the vestibulocerebellum were ablated in two monkeys, and the effects of nodulouvulectomy and flocculectomy on VOR gain adaptation and habituation were compared. The VOR time constant decreased with repeated testing, rapidly at first and more slowly thereafter. The gain of the VOR was unaffected. Massed trials were more effective than distributed trials in producing habituation. Regardless of the schedule of testing, the VOR time constant never fell below the time constant of the semicircular canals (approximately 5 s). This finding indicates that only the slow component of the vestibular response, the component produced by velocity storage, was habituated. In agreement with this, the time constant of optokinetic after-nystagmus (OKAN) was habituated concurrently with the VOR. Average values for VOR habituation were obtained on a per session basis for six animals. The VOR gain was adapted by natural head movements in partially habituated monkeys while they wore x 2.2 magnifying or x 0.5 reducing lenses. Adaptation occurred rapidly and reached about +/- 30%, similar to values obtained using forced rotation. VOR gain adaptation did not cause additional habituation of the time constant. When the VOR gain was reduced in animals with a long VOR time constant, there were overshoots in eye velocity that peaked at about 6-8 s after the onset or end of constant-velocity rotation. These overshoots occurred at times when the velocity storage integrator would have been maximally activated by semicircular canal input. Since the activity generated in the canals is not altered by visual adaptation, this finding indicates that the gain element that controls rapid changes in eye velocity in the VOR is separate from that which couples afferent input to velocity storage. Nodulouvulectomy caused a prompt and permanent loss of habituation, returning VOR time constants to initial values. VOR gain adaptation, which is lost after flocculectomy, was unaffected by nodulouvulectomy. Flocculectomy did not alter habituation of the VOR or of OKAN. Using a simplified model of the VOR, the decrease in the duration of vestibular nystagmus due to habituation was related to a decrement in the dominant time constant of the velocity storage integrator (1/h0).(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

Development of an Antimicrobial Susceptibility Testing Method Suitable for Performing During Space Flight

Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control (normal gravity) MIC values will be generated by simultaneous inoculation and incubation of a second set of test cards in a laboratory at the launch site. This procedure can provide a safe and compact experiment that should yield new information on the affects of microgravity on the biological activities of various classes of antibiotics.

Jorgensen, James H.↗

Magnetic tape

The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

Robinson, Harriss↗

Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

Hunter, Gary W.↗

Reservoir Assessment Tool 2.0: Stakeholder driven improvements to satellite remote sensing based reservoir monitoring

In light of the rapidly increasing regulation of rivers due to planned and constructed reservoirs, monitoring reservoir operations has become very crucial. The Reservoir Assessment Tool (RAT) framework was developed to monitor reservoir operations globally, using hydrological modeling and satellite observations. With feedback from stakeholders, improvements in the RAT framework are demonstrated in this study using the Mekong River Basin as an example. A novel multi-sensor reservoir area mapping technique was developed using complementary strengths of optical and SAR sensors at a 1-5 day temporal resolution, allowing the quantification of sub-weekly reservoir operations. Additionally, the skill of radar altimeters in the RAT framework was tested using the Jason-3 altimeter. Using in-situ data from three Thai reservoirs in the Mekong Basin, consistent improvements were observed as compared to the original RAT framework. A functionality for visualizing forecasted outflow was also added using historically inferred reservoir operations or stakeholder-driven target storage expectations.

Reservoirs↗

HERMES: A cyber-energy SAAS platform to provide real-time 2d and 3d interactive visualizations [SWR-23-15]

HERMES is a novel visualization SAAS platform for achieving real-time visualization of large-scale environments involving cyber-energy devices. The platform receives data from emulated environments which include physical hardware and network devices that represent a complex IT / OT system. The platform is capable of streaming, filtering, storing, and visualizing all data within the environment and scaling vertically and horizontally. This capability enables high fidelity visual analysis of events to be performed in real time as well as the collection and storage of historical data for forensic analysis.

Van Natta, Joshua↗

Computer storage and retrieval of coronary trees

Coronary cineangiography is a routine procedure for evaluation of the coronary circulation. From the biplane cineangiograms a visual representation of coronary perfusion was obtained. A collection of simple ideas and procedures to aid in the collection is described. The uses to which the tree data will be put include the evaluation of myocardial function and the formation of a library sufficiently large to enable some taxonomic classification of coronary artery patterns to be made.

Starmer, C. F.↗

A Visual Understanding of Circular Dichroism Spectroscopy

Mapping chemical and structural properties to electronic and magnetic responses is critical to many applications such as quantum information science, where the precise storage and transmission of unique information is paramount. Specifically, constructing molecules and materials that provide strong polarized responses at tunable frequencies and with large anisotropies is key to optical processing of quantum information. Chiral molecules provide chiroptical response to circularly polarized light, making them attractive for quantum information science and other applications related to sensing, polarized photodetectors, and spintronics. Predicting a molecular design, a priori, with large anisotropies to circularly polarized light is challenging due to the complex interplay between electric and magnetic components of the optical response. In this work, we explore a visual representation of the electronic chiroptical response by decomposing the rotary strength into its constituent components. Here, we make use of the intuitive electronic oscillator framework to develop classical intuition regarding the rotary strength and its constituents. We explore three model chemical systems that exhibit local and global chirality. Our analysis reveals that local chirality necessarily exhibits competition between the local chiral center and chirality induced in other fragments of the molecule, resulting in both unexpected nonmonotonic trends and sign flips in chemically adjacent geometries. Furthermore, we can visually distinguish between local and global chirality via examination of the transition chiral tensor. Interestingly, we make strong connections to ferromagnetic and antiferromagnetic spin systems in that chiroptically inactive transitions exhibit antiferromagnetic-like alternating orbital patterns while active transitions show domain formation in an ferromagnetic-like alignment that produces a net chiroptical response.

36 MATERIALS SCIENCE↗

Visualization techniques to aid in the analysis of multi-spectral astrophysical data sets

The goal of this project was to support the scientific analysis of multi-spectral astrophysical data by means of scientific visualization. Scientific visualization offers its greatest value if it is not used as a method separate or alternative to other data analysis methods but rather in addition to these methods. Together with quantitative analysis of data, such as offered by statistical analysis, image or signal processing, visualization attempts to explore all information inherent in astrophysical data in the most effective way. Data visualization is one aspect of data analysis. Our taxonomy as developed in Section 2 includes identification and access to existing information, preprocessing and quantitative analysis of data, visual representation and the user interface as major components to the software environment of astrophysical data analysis. In pursuing our goal to provide methods and tools for scientific visualization of multi-spectral astrophysical data, we therefore looked at scientific data analysis as one whole process, adding visualization tools to an already existing environment and integrating the various components that define a scientific data analysis environment. As long as the software development process of each component is separate from all other components, users of data analysis software are constantly interrupted in their scientific work in order to convert from one data format to another, or to move from one storage medium to another, or to switch from one user interface to another. We also took an in-depth look at scientific visualization and its underlying concepts, current visualization systems, their contributions, and their shortcomings. The role of data visualization is to stimulate mental processes different from quantitative data analysis, such as the perception of spatial relationships or the discovery of patterns or anomalies while browsing through large data sets. Visualization often leads to an intuitive understanding of the meaning of data values and their relationships by sacrificing accuracy in interpreting the data values. In order to be accurate in the interpretation, data values need to be measured, computed on, and compared to theoretical or empirical models (quantitative analysis). If visualization software hampers quantitative analysis (which happens with some commercial visualization products), its use is greatly diminished for astrophysical data analysis. The software system STAR (Scientific Toolkit for Astrophysical Research) was developed as a prototype during the course of the project to better understand the pragmatic concerns raised in the project. STAR led to a better understanding on the importance of collaboration between astrophysicists and computer scientists.

Brugel, Edward W.↗

Visualization techniques to aid in the analysis of multispectral astrophysical data sets

The goal of this project was to support the scientific analysis of multi-spectral astrophysical data by means of scientific visualization. Scientific visualization offers its greatest value if it is not used as a method separate or alternative to other data analysis methods but rather in addition to these methods. Together with quantitative analysis of data, such as offered by statistical analysis, image or signal processing, visualization attempts to explore all information inherent in astrophysical data in the most effective way. Data visualization is one aspect of data analysis. Our taxonomy as developed in Section 2 includes identification and access to existing information, preprocessing and quantitative analysis of data, visual representation and the user interface as major components to the software environment of astrophysical data analysis. In pursuing our goal to provide methods and tools for scientific visualization of multi-spectral astrophysical data, we therefore looked at scientific data analysis as one whole process, adding visualization tools to an already existing environment and integrating the various components that define a scientific data analysis environment. As long as the software development process of each component is separate from all other components, users of data analysis software are constantly interrupted in their scientific work in order to convert from one data format to another, or to move from one storage medium to another, or to switch from one user interface to another. We also took an in-depth look at scientific visualization and its underlying concepts, current visualization systems, their contributions and their shortcomings. The role of data visualization is to stimulate mental processes different from quantitative data analysis, such as the perception of spatial relationships or the discovery of patterns or anomalies while browsing through large data sets. Visualization often leads to an intuitive understanding of the meaning of data values and their relationships by sacrificing accuracy in interpreting the data values. In order to be accurate in the interpretation, data values need to be measured, computed on, and compared to theoretical or empirical models (quantitative analysis). If visualization software hampers quantitative analysis (which happens with some commercial visualization products), its use is greatly diminished for astrophysical data analysis. The software system STAR (Scientific Toolkit for Astrophysical Research) was developed as a prototype during the course of the project to better understand the pragmatic concerns raised in the project. STAR led to a better understanding on the importance of collaboration between astrophysicists and computer scientists. Twenty-one examples of the use of visualization for astrophysical data are included with this report. Sixteen publications related to efforts performed during or initiated through work on this project are listed at the end of this report.

Brugel, E. W.↗

Lost in space: Onboard star identification using CCD star tracker data without an a priori attitude

There are many algorithms in use today which determine spacecraft attitude by identifying stars in the field of view of a star tracker. Some methods, which date from the early 1960's, compare the angular separation between observed stars with a small catalog. In the last 10 years, several methods have been developed which speed up the process and reduce the amount of memory needed, a key element to onboard attitude determination. However, each of these methods require some a priori knowledge of the spacecraft attitude. Although the Sun and magnetic field generally provide the necessary coarse attitude information, there are occasions when a spacecraft could get lost when it is not prudent to wait for sunlight. Also, the possibility of efficient attitude determination using only the highly accurate CCD star tracker could lead to fully autonomous spacecraft attitude determination. The need for redundant coarse sensors could thus be eliminated at substantial cost reduction. Some groups have extended their algorithms to implement a computation intense full sky scan. Some require large data bases. Both storage and speed are concerns for autonomous onboard systems. Neural network technology is even being explored by some as a possible solution, but because of the limited number of patterns that can be stored and large overhead, nothing concrete has resulted from these efforts. This paper presents an algorithm which, by descretizing the sky and filtering by visual magnitude of the brightness observed star, speeds up the lost in space star identification process while reducing the amount of necessary onboard computer storage compared to existing techniques.

Ketchum, Eleanor A.↗

Sandia Machine Learning Laboratory

Samlab provides a workflow and data storage for machine learning experiment inputs and outputs using mongodb, and a web service to manage, search, visualize, and analyze the results.

Shead, Timothy↗

Method and device for the detection and identification of a helicopter

The invention presents a method for detecting and identifying a helicopter based on its characteristic emission of energy in the visual and infrared regions as well as acoustic energy by employing a fire control computer with data storage and a device for targeting and observation.

Siebecker, Hans↗

Spatial orientation of optokinetic nystagmus and ocular pursuit during orbital space flight

On Earth, eye velocity of horizontal optokinetic nystagmus (OKN) orients to gravito-inertial acceleration (GIA), the sum of linear accelerations acting on the head and body. We determined whether adaptation to micro-gravity altered this orientation and whether ocular pursuit exhibited similar properties. Eye movements of four astronauts were recorded with three-dimensional video-oculography. Optokinetic stimuli were stripes moving horizontally, vertically, and obliquely at 30 degrees/s. Ocular pursuit was produced by a spot moving horizontally or vertically at 20 degrees/s. Subjects were either stationary or were centrifuged during OKN with 1 or 0.5 g of interaural or dorsoventral centripetal linear acceleration. Average eye position during OKN (the beating field) moved into the quick-phase direction by 10 degrees during lateral and upward field movement in all conditions. The beating field did not shift up during downward OKN on Earth, but there was a strong upward movement of the beating field (9 degrees) during downward OKN in the absence of gravity; this likely represents an adaptation to the lack of a vertical 1-g bias in-flight. The horizontal OKN velocity axis tilted 9 degrees in the roll plane toward the GIA during interaural centrifugation, both on Earth and in space. During oblique OKN, the velocity vector tilted towards the GIA in the roll plane when there was a disparity between the direction of stripe motion and the GIA, but not when the two were aligned. In contrast, dorsoventral acceleration tilted the horizontal OKN velocity vector 6 degrees in pitch away from the GIA. Roll tilts of the horizontal OKN velocity vector toward the GIA during interaural centrifugation are consistent with the orientation properties of velocity storage, but pitch tilts away from the GIA when centrifuged while supine are not. We speculate that visual suppression during OKN may have caused the velocity vector to tilt away from the GIA during dorsoventral centrifugation. Vertical OKN and ocular pursuit did not exhibit orientation toward the GIA in any condition. Static full-body roll tilts and centrifugation generating an equivalent interaural acceleration produced the same tilts in the horizontal OKN velocity before and after flight. Thus, the magnitude of tilt in OKN velocity was dependent on the magnitude of interaural linear acceleration, rather than the tilt of the GIA with regard to the head. These results favor a 'filter' model of spatial orientation in which orienting eye movements are proportional to the magnitude of low frequency interaural linear acceleration, rather than models that postulate an internal representation of gravity as the basis for spatial orientation.

Flight Experiment↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss.” In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316L tubing under static immersion. In such conditions, parylene-C and AF4 coatings have shown excellent Ag+ loss mitigation performance, and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we begin to address the performance of parylene-C barrier coatings under more challenging and realistic conditions, in order to evaluate potential suitability in flight systems. Using two testbeds, we characterized coating performance under dynamic mechanical operation. In the Flow/Pressure Testbed System, Ag+ solution is pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution is cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. Periodic determinations of Ag+ loss with testbed cycling/time and visual observation of the parylene-C coatings were conducted. In addition, we characterized parylene-C coating resilience and Ag+ loss with 316L tubing and multiple fitting types under long-term immersion and repeated fitting dis/reassembly.