Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wall temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

MLITemp: A computer program to predict the thermal effects associated with hypervelocity impact damage to space station MLI

A family of user-friendly, DOS PC based, Microsoft BASIC programs written to provide spacecraft designers with empirical predictions of space debris damage to orbiting spacecraft are described. Spacecraft wall temperatures and condensate formation is also predicted. The spacecraft wall configuration is assumed to consist of multilayered insulation (MLI) placed between a Whipple style bumper and the pressure wall. Impact damage predictions are based on data sets of experimental results obtained from simulating debris impacts on spacecraft using light gas guns on earth. A module of the program facilitates the creation of the database of experimental results that is used by the damage prediction modules to predict damage to the bumper, the MLI, and the pressure wall. A finite difference technique is used to predict temperature distributions in the pressure wall, the MLI, and the bumper. Condensate layer thickness is predicted for the case where the pressure wall temperature drops below the dew point temperature of the spacecraft atmosphere.

Rule, W. K.↗

Small rocket flowfield diagnostic chambers

Instrumented and optically-accessible rocket chambers are being developed to be used for diagnostics of small rocket (less than 440 N thrust level) flowfields. These chambers are being tested to gather local fluid dynamic and thermodynamic flowfield data over a range of test conditions. This flowfield database is being used to better understand mixing and heat transfer phenomena in small rockets, influence the numerical modeling of small rocket flowfields, and characterize small rocket components. The diagnostic chamber designs include: a chamber design for gathering wall temperature profiles to be used as boundary conditions in a finite element heat flux model; a chamber design for gathering inner wall temperature and static pressure profiles; and optically-accessible chamber designs, to be used with a suite of laser-based diagnostics for gathering local species concentration, temperature, density, and velocity profiles. These chambers were run with gaseous hydrogen/gaseous oxygen (GH2/GO2) propellants, while subsequent versions will be run on liquid oxygen/hydrocarbon (LOX/HC) propellants. The purpose, design, and initial test results of these small rocket flowfield diagnostic chambers are summarized.

Morren, Sybil↗

Correlation and analysis of elevon seal test results

The heating rate and pressure distributions in and around the elevon coves were correlated. An analytical approach incorporating such a correlation into a thermal structure computer code to examine the elevon seal and cover structure in flight was developed. Emphasis was placed on the design of a thermal model that predicts gas and wall temperatures in the cove area. The elevon cove area was modelled analytically by a parallel plate flow channel, incorporating effects of axial wall conduction, axial and environmental radiant energy exchanges, and effects of laminar and turbulent convection entrance regions. Comparisons were made between computed and measured values of (1) cove wall temperatures; (2) local gas temperature within the cove; and (3) local heating rates.

Keshock, E. G.↗

Effect of Reynolds number variation on aerodynamics of a hydrogen-fueled transport concept at Mach 6

Two separate tests have been made on the same blended wing-body hydrogen-fueled transport model at a Mach number of about 6 and a range of Reynolds number (based on theoretical body length) of 1.577 to 55.36 X 10 to the 6th power. The results of these tests, made in a conventional hypersonic blowdown tunnel and a hypersonic shock tunnel, are presented through a range of angle of attack from -1 to 8 deg, with an extended study at a constant angle of attack of 3 deg. The model boundary layer flow appeared to be predominately turbulent except for the low Reynolds number shock tunnel tests. Model wall temperatures varied considerably; the blowdown tunnel varied from about 255 F to 340 F, whereas the shock tunnel had a constant 70 F model wall temperature. The experimental normal-force coefficients were essentially independent of Reynolds number. A current theoretical computer program was used to study the effect of Reynolds number. Theoretical predictions of normal-force coefficients were good, particularly at anticipated cruise angles of attack, that is 2 to 5 deg. Axial-force coefficients were generally underestimated for the turbulent skin friction conditions, and pitching-moment coefficients could not be predicted reliably.

Penland, Jim A.↗

Experimentation and Modeling of Jet A Thermal Stability in a Heated Tube

High performance aircraft typically use hydrocarbon fuel to regeneratively cool the airframe and engine components. As the coolant temperatures increase, the fuel may react with dissolved oxygen forming deposits that limit the regenerative cooling system performance. This study investigates the deposition of Jet A using a thermal stability experiment and computational fluid dynamics (CFD) modeling. The experimental portion of this study is performed with a high Reynolds number thermal stability (HiRets) tester in which fuel passes though an electrically heated tube and the fuel outlet temperature is held constant. If the thermal stability temperature of the fuel is exceeded, deposits form and adhere to the inside of the tube creating an insulating layer between the tube and the fuel. The HiRets tester measures the tube outer wall temperatures near the fuel outlet to report the effect of deposition occurring inside the tube. Final deposits are also estimated with a carbon burn off analysis. The CFD model was developed and used to simulate the fluid dynamics, heat transfer, chemistry, and transport of the deposit precursors. The model is calibrated to the experiment temperature results and carbon burn-off deposition results. The model results show that the dominant factor in deposition is the heated wall temperature and that most of the deposits are formed in the laminar sublayer. The models predicted a 7.0E-6 kilograms per square meter-sec deposition rate, which compared well to the carbon burn-off analysis deposition rate of 1.0E-6 kilograms per square meter-sec.

Khodabandeh, Julia W.↗

Correlation of Forced-convection Heat-transfer Data for Air Flowing in Smooth Platinum Tube with Long-approach Entrance at High Surface and Inlet-air Temperatures

A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.

Desmon, Leland G↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill process to develop an analytical model of No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing stage, but then becomes less significant.

Chato, David J.↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing state, but then becomes less significant.

Chato, David J.↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Transfer from High-Temperature Surfaces to Fluids III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperatures up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R.

Sams, Eldon W.↗

An experimental investigation of high-aspect-ratio cooling passages

An experimental investigation was conducted to evaluate the effectiveness of using high-aspect-ratio cooling passenges to improve the life and reduce the colant pressure drop in high-pressure rocket thrust chambers. A plug-nozzle rocket-engine test apparatus was used to test two cylindrical chambers with low-aspect-ratio cooling passages and one with high-aspect-ratio cooling passages. The chambers were cyclically tested and data were taken over a wide range of coolant mass flows. The results showed that for the same coolant pressure drop, the hot-gas-side wall temperature of the high-aspect-ratio chamber was 30 percent lower than the baseline low-aspect-ratio chamber, resulting in no fatigue damage to the wall. The coolant pressure drop for the high-aspect-ratio chamber was reduced in increments to one-half that of the baseline chamber, by reducing the coolant mass flow, and still resulted in a reduction in the hot-gas-side wall temperature when compared to the low-aspect-ratio chambers.

Carlile, Julie A.↗

An experimental investigation of high-aspect-ratio cooling passages

An experimental investigation was conducted to evaluate the effectiveness of using high-aspect-ratio cooling passages to improve the life and reduce the coolant pressure drop in high-pressure rocket thrust chambers. A plug-nozzle rocket-engine test apparatus was used to test two cylindrical chambers with low-aspect-ratio cooling passages and one with high-aspect-ratio cooling passages. The chambers were cyclically tested and data were taken over a wide range of coolant mass flows. The results showed that for the same coolant pressure drop, the hot-gas-side wall temperature of the high-aspect-ratio chamber was 30 percent lower than the baseline low-aspect-ratio chamber, resulting in no fatigue damage to the wall. The coolant pressure drop for the high-aspect-ratio chamber was reduced in increments to one-half that of the baseline chamber, by reducing the coolant mass flow, and still resulted in a reduction in the hot-gas-side wall temperature when compared to the low-aspect-ratio chambers.

Carlile, Julie A.↗

Analysis of film cooling in rocket nozzles

Progress during the reporting period is summarized. Analysis of film cooling in rocket nozzles by computational fluid dynamics (CFD) computer codes is desirable for two reasons. First, it allows prediction of resulting flow fields within the rocket nozzle, in particular the interaction of the coolant boundary layer with the main flow. This facilitates evaluation of potential cooling configurations with regard to total thrust, etc., before construction and testing of any prototype. Secondly, CFD simulation of film cooling allows for assessment of the effectiveness of the proposed cooling in limiting nozzle wall temperature rises. This latter objective is the focus of the current work. The desired objective is to use the Finite Difference Navier Stokes (FDNS) code to predict wall heat fluxes or wall temperatures in rocket nozzles. As prior work has revealed that the FDNS code is deficient in the thermal modeling of boundary conditions, the first step is to correct these deficiencies in the FDNS code. Next, these changes must be tested against available data. Finally, the code will be used to model film cooling of a particular rocket nozzle. The third task of this research, using the modified code to compute the flow of hot gases through a nozzle, is described.

Woodbury, Keith A.↗

Alternate-Fueled Combustor-Sector Performance: (A) Combustor Performance; (B) Combustor Emissions - Parts A and B

Alternate aviation fuels for military or commercial use are required to satisfy MIL-DTL-83133F(2008) or ASTM D 7566 (2010) standards, respectively, and are classified as "drop-in" fuel replacements. To satisfy legacy issues, blends to 50% alternate fuel with petroleum fuels are certified individually on the basis of processing and assumed to be feedstock agnostic. Adherence to alternate fuels and fuel blends requires "smart fueling systems" or advanced fuel-flexible systems, including combustors and engines, without significant sacrifice in performance or emissions requirements. This paper provides preliminary performance (Part A) and emissions and particulates (Part B) combustor sector data. The data are for nominal inlet conditions at 225 psia and 800 F (1.551 MPa and 700 K), for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100 relative to JP-8+100 as baseline fueling. Assessments are made of the change in combustor efficiency, wall temperatures, emissions, and luminosity with SPK of 0%, 50%, and 100% fueling composition at 3% combustor pressure drop. The performance results (Part A) indicate no quantifiable differences in combustor efficiency, a general trend to lower liner and higher core flow temperatures with increased FT fuel blends. In general, emissions data (Part B) show little differences, but with percent increase in FT-SPK-type fueling, particulate emissions and wall temperatures are less than with baseline JP-8. High-speed photography illustrates both luminosity and combustor dynamic flame characteristics.

Shouse, D. T.↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan- stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to provide operating conditions such that ice would accrete in either the fan-stator through the inlet guide vane region of the compression system or within the first stator of the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDESMELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet-bulb temperature thresholds were applied for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applied to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions. The goal of this study is to show that the computational process developed on earlier engine icing tests can be used to provide an icing risk assessment in adiabatic regions for other engines.

Turbofan engine↗

A dual-cooled hydrogen-oxygen rocket engine heat transfer analysis

The potential benefits of simultaneously using hydrogen and oxygen as rocket engine coolants are described. A plug-and-spool rocket engine was examined at heat fluxes ranging from 9290 to 163,500 kW/sq m, using a combined 3D conduction/advection analysis. Both counterflow and parallel flow cooling arrangements were analyzed. The results indicate that a significant amount of heat transfer to the oxygen occurs, reducing both the hot-side wall temperature of the rocket engine and also reducing the exit temperature of the hydrogen coolant. The total heat transferred to the oxygen was found to be largely independent of the oxygen coolant flow direction. The reduction in combustion chamber wall temperatures at throttled conditions is especially desirable since the analysis indicates that double temperature maxima, one at the throat and another in the combustion chamber, occur with a traditional hydrogen-only cooled engine. A dual-cooled engine eliminates any concern for overheating in the combustion chamber.

Kacynski, Kenneth J.↗