Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental demonstration of necessary conditions for X-ray induced synthesis of cesium superoxide

Absorption of sufficiently energetic X-ray photons by a molecular system results in a cascade of ultrafast electronic relaxation processes which leads to a distortion and dissociation of its molecular structure. Here, in this work, we demonstrate that only decomposition of powdered cesium oxalate monohydrate induced by monochromatic X-ray irradiation under high pressure leads to the formation of cesium superoxide. Whereas, for an unhydrated form of cesium oxalate subjected to the same extreme conditions, only degradation of the electron density distribution is observed. Moreover, the corresponding model of X-ray induced electronic relaxation cascades with an emphasis on water molecules’ critical role is proposed. Our experimental results suggest that the presence of water molecules in initially solid-state systems (i.e. additional electronic relaxation channels) together with applied high pressure (reduced interatomic/intermolecular distance) could potentially be a universal criteria for chemical and structural synthesis of novel compounds via X-ray induced photochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing the nexus between groundwater and solar energy plants in a desert basin with a dual-model approach under uncertainty

Globally, many solar power plants and other types of renewable energy are being located in water-scarce regions. Many projects rely on groundwater resources whose sustainability is uncertain. In the Chuckwalla Basin in California, quantification of recharge and trans-valley underflow is needed to estimate the impacts of solar project withdrawals on the water table. However, such estimates are highly challenging due to data scarcity, heterogeneous soils and long residence times. Conventional assessment employs isolated groundwater models configured with crude and uniform estimates of recharge. Here, we employ a data-constrained surface subsurface processes model, PAWS+CLM, to provide an ensemble of recharges and underflows with perturbed parameters. Then, the Parameter Estimation (PEST) package is used to calibrate MODFLOW aquifer conductivity and filter out implausible recharges. The novel dual-model approach, potentially applicable in other arid regions, can effectively assimilate groundwater head observations, reject unrealistic parameters, and narrow the range of estimated drawdowns. Simulated recharge concentrates along alluvial fans at the mountain fronts and ephemeral washes where run-off water infiltrates. If an evenly distributed recharge was assumed, it resulted in under-estimated drawdown and larger uncertainty bounds. The withdrawals are approaching total inflow, suggesting the system will be nearing, if not exceeding, its sustainable groundwater production capacity, and a boom of such projects will not be sustainable. Especially, the cost/benefit of pumped-storage projects is called into question as the initial-fill phase depletes entire area’s recharge. Our study highlights the stress on groundwater resources of solar development, and that the speed of groundwater recovery does not indicate sustainability. Main point 1: A novel dual model approach, involving an integrated surface/subsurface model and a groundwater parameter-estimation model, was able to better constrain the model. Main point 2: The groundwater system may be nearing, if not exceeding, its sustainable groundwater production capacity and the speed of recovery is not indicative of sustainability. Main point 3: Results from using conventionally-assumed uniform recharge distort calibrated K fields and impacts assessment

14 SOLAR ENERGY↗

Evaluation of liquid cloud albedo susceptibility in E3SM using coupled eastern North Atlantic surface and satellite retrievals

The impact of aerosol number concentration on cloud albedo is a persistent source of spread in global climate predictions due to multi-scale, interactive atmospheric processes that remain difficult to quantify. We use 5 years of geostationary satellite and surface retrievals at the US Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) eastern North Atlantic (ENA) site in the Azores to evaluate the representation of liquid cloud albedo susceptibility for overcast cloud scenes in the DOE Energy Exascale Earth System Model version 1 (E3SMv1) and provide possible reasons for model–observation discrepancies. The overall distribution of surface 0.2 % CCN concentration values is reasonably simulated, but simulated liquid water path (LWP) is lower than observed and layer mean droplet concentration (N d ) comparisons are highly variable depending on the N d retrieval technique. E3SMv1's cloud albedo is greater than observed for given LWP and N d values due to a lower cloud effective radius than observed. However, the simulated albedo response to N d is suppressed due to a correlation between the solar zenith angle (SZA) and N d created by the seasonal cycle that is not observed. Controlling for this effect by examining the cloud optical depth (COD) shows that E3SMv1's COD response to CCN concentration is greater than observed. For surface-based retrievals, this is only true after controlling for cloud adiabaticity because E3SMv1's adiabaticities are much lower than observed. Assuming a constant adiabaticity in surface retrievals as done in top-of-atmosphere (TOA) retrievals narrows the retrieved ln N d distribution, which increases the cloud albedo sensitivity to ln N d to match the TOA sensitivity. The greater sensitivity of COD to CCN is caused by a greater Twomey effect in which the sensitivity of N d to CCN is greater than observed for TOA-retrieved N d , and once model–observation cloud adiabaticity differences are removed, this is also true for surface-retrieved N d . The LWP response to N d in E3SMv1 is overall negative as observed. Despite reproducing the observed LWP–N d relationship, observed clouds become much more adiabatic as N d increases, while E3SMv1 clouds do not, associated with more heavily precipitating clouds that are partially but not completely caused by deeper clouds and weaker inversions in E3SMv1. These cloud property differences indicate that the negative LWP–N d relationship is likely not caused by the same mechanisms in E3SMv1 and observations. The negative simulated LWP response also fails to mute the excessively strong Twomey effect, highlighting potentially important confounding factor effects that likely render the LWP–N d relationship non-causal. N d retrieval scales and assumptions, particularly related to cloud adiabaticity, contribute to substantial spreads in the model–observation comparisons, though enough consistency exists to suggest that aerosol activation, drizzle, and entrainment processes are critical areas to focus E3SMv1 development for improving the fidelity of aerosol–cloud interactions in E3SM.

54 ENVIRONMENTAL SCIENCES↗

Remote monitoring system

A remote monitoring system for monitoring parameters of an underground asset, such as an electric cable system, a pipeline serving as a conduit for water, gas, oil, sewage, or the like. Parameter detectors, such as sensors that measure temperature, voltage, current, moisture, etc., are distributed along the asset to provide electrical signals that represent respective monitored parameters of the asset. An underground hub disposed in an underground vault, or manhole, through which the asset passes is coupled to the parameter detectors to acquire the signals provided by the parameter detectors. The hub includes a controller to provide data derived from the acquired signals, the data being transmitted to a remote central location by a transceiver, or modem, via LP-WAN communication. Signals from the transceiver are transmitted directly from underground.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing soil water content variability across spatial scales from optimized high-resolution distributed temperature sensing technique

Fiber-optic Distributed Temperature Sensing, when combined with the Single-probe Heat-pulse technique can measure soil moisture (θ) across spatial scales. The key limitation of this system is in obtaining the relationship between soil thermal conductivity (λ) and θ for a specific field. Using the Department of Energy Atmospheric Radiation Measurement (ARM) site, this study tested a new methodology to account for the spatial variability in the λ-θ relationship using a Gaussian processes model. The resulting accurate θ measurements (RMSE = 0.03 m 3 m –3 ) were used to characterize the spatial variability of θ across scales and to develop an empirical equation that can correct for the changes in the θ spatial variability observed at different spatial resolutions. In addition, the number of required samples to accurately characterize θ and its variability over scales ranging from 5 m and 350 m were estimated. Finally, these findings provide key information to scale soil moisture from centimeters to hundreds of meters for process understanding.

54 ENVIRONMENTAL SCIENCES↗

Coupled wave-current modeling for hydrodynamic load analysis of macroalgae cultivation farms

Large-scale cultivation of macroalgae is one of the most promising biofuel sources that could reduce our consumption of fossil fuels and would be particularly economically competitive when grown for the co-production of additional goods such as food and textiles. Current production of biofuel from algal biomass is limited by labor costs and lack of data on potential impacts of cultivation and harvesting on marine and coastal environments as well as a comprehensive characterization of the impact of environmental conditions on macroalgal feedstock and their bioproduct and biofuel yield and quality. Awarded by the United States (U.S.) Department of Energy Advanced Research Projects Agency-Energy (ARPA-E) Macroalgae Research Inspiring Novel Energy Resources (MARINER) program, which seeks to enable the U.S. as a global leader in the production of marine biomass, the Marine Biological Laboratory (MBL) has been developing a test system for tropical seaweed cultivation in the Gulf of Mexico and the Caribbean. An integral step in designing macroalgae cultivation farms is to adequately characterize the hydrodynamic climate at potential growth sites. In regions like the Gulf of Mexico and the Caribbean, which are highly exposed to tropical cyclones, it is critical to not only consider the day-to-day hydrodynamic conditions but to also assess the risk of extreme sea states to ensure the survivability of future macroalgae farms. Under these considerations, the Pacific Northwest National Laboratory (PNNL) is providing modeling support for MBL to inform the design and siting of the farm systems that have been proposed for their ARPA-E MARINER project. This report describes the development of a high-resolution coupled storm surge and wave model to simulate the hydrodynamics and wave climate at proposed macroalgae cultivation sites selected by MBL in Florida and Puerto Rico. Model results, including model validation, water level, current distributions, and sea states, are discussed for both selected sites in Florida and Puerto Rico coast. These simulations provide an accurate insight into the hydrodynamic conditions that a macroalgae farm is likely to experience during its operational lifetime, including current information to support fine-scale hydrodynamic load modeling, risk analysis and system design.

09 BIOMASS FUELS↗

Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the Ukrainian version of this report, see NREL/TP-7A40-90360 (https://www.nrel.gov/docs/fy24osti/90360.pdf).

14 SOLAR ENERGY↗

ТЕХНІКО-ЕКОНОМІЧНИЙ АНАЛІЗ ПОТЕНЦІАЛУ ІНТЕГРАЦІЇ РОЗПОДІЛЕНИХ ЕНЕРГЕТИЧНИХ РЕСУРСІВ ДЛЯ ВОДОКАНАЛУ М.ЧЕРВОНОГРАД В УКРАЇНІ [Technical and Economic Screening for Potential of Distributed Energy Resource Integration at Chervonohrad Water Utility in Ukraine] (Ukrainian Translation)

In this report, the authors present a preliminary techno-economic screening for distributed renewable energy for Chervonohrad Vodokanal, the water utility in Chervonohrad, Ukraine. The screening estimates the technical potential and economics of integrating solar photovoltaics (PV) and battery energy storage systems (BESS) at Chervonohrad Vodokanal water pumping stations, Pravda, Bendiuha, and Mezhyrichchya. For the English version of this report, see NREL/TP-7A40-89599 (https://www.nrel.gov/docs/fy24osti/89599.pdf).

14 SOLAR ENERGY↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Quantification of hydraulic trait control on plant hydrodynamics and risk of hydraulic failure within a demographic structured vegetation model in a tropical forest (FATES–HYDRO V1.0)

Abstract. Vegetation plays a key role in the global carbon cycle and thus is an important component within Earth system models (ESMs) that project future climate. Many ESMs are adopting methods to resolve plant size and ecosystem disturbance history, using vegetation demographic models. These models make it feasible to conduct more realistic simulation of processes that control vegetation dynamics. Meanwhile, increasing understanding of the processes governing plant water use, and ecosystem responses to drought in particular, has led to the adoption of dynamic plant water transport (i.e., hydrodynamic) schemes within ESMs. However, the extent to which variations in plant hydraulic traits affect both plant water stress and the risk of mortality in trait-diverse tropical forests is understudied. In this study, we report on a sensitivity analysis of an existing hydrodynamic scheme (HYDRO) model that is updated and incorporated into the Functionally Assembled Terrestrial Ecosystem Simulator (FATES) (FATES–HYDRO V1.0). The size- and canopy-structured representation within FATES is able to simulate how plant size and hydraulic traits affect vegetation dynamics and carbon–water fluxes. To better understand this new model system, and its functionality in tropical forest systems in particular, we conducted a global parameter sensitivity analysis at Barro Colorado Island, Panama. We assembled 942 observations of plant hydraulic traits on 306 tropical plant species for stomata, leaves, stems, and roots and determined the best-fit statistical distribution for each trait, which was used in model parameter sampling to assess the parametric sensitivity. We showed that, for simulated leaf water potential and loss of hydraulic conductivity across different plant organs, the four most important traits were associated with xylem conduit taper (buffers increasing hydraulic resistance with tree height), stomatal sensitivity to leaf water potential, maximum stem hydraulic conductivity, and the partitioning of total hydraulic resistance above vs. belowground. Our analysis of individual ensemble members revealed that trees at a high risk of hydraulic failure and potential tree mortality generally have a lower conduit taper, lower maximum xylem conductivity, lower stomatal sensitivity to leaf water potential, and lower resistance to xylem embolism for stem and transporting roots. We expect that our results will provide guidance on future modeling studies using plant hydrodynamic models to predict the forest responses to droughts and future field campaigns that aim to better parameterize plant hydrodynamic models.

54 ENVIRONMENTAL SCIENCES↗

Dynamically Downscaled (WRF) 1km, Hourly Meteorological Conditions 1987-2020. East/Taylor Watersheds

This dataset contains meteorological output from the Weather Research and Forecasting (WRF) version 3.8.1. This dataset has been created to 1) investigate hydrometeorological processes impacting the East River and water-delivery to the Critical Zone, and 2) provide meteorological forcing data for distributed Earth-science modeling applications in the East River watershed. Variables have a 1 kilometer spatial resolution and hourly temporal resolution and encompass a rectangular region encompassing the East and Taylor River watersheds, Colorado, near the town of Crested Butte. WRF was forced using Climate Forecast System Reanalysis (CFSR) lateral boundary conditions. Each .zip file contains one "water year" of data (October 1 -- September 30; i.e. water year 2017 starts October 1, 2016 and ends September 30, 2017). Each zip folder contains 12 netcdf (.nc) files containing one month of hourly data each and are approximately 250mb. Model timestamps are in UTC time.The files contain the following data variables:EAST_MASK: binary mask of the watershed regionTAYLOR_MASK: binary mask of the watershed regionGLW downwelling longwave radiation (w/m2)HR_PRCP: Hourly Precipitation Rate (mm/hr). Includes all hydrometeors (solid+liquid). HFX NoahMP LSM total grid-cell modelled sensible heat flux (w/m2) [positive towards atmosphere]LH NoahMP LSM total grid-cell modelled latent heat flux (w/m2) [positive towards atmosphere; can be converted to ET]PSFC Surface Barometric Pressure (hPa)Q2 Two-meter specific humidity (kg/kg)SWDOWN Downwelling shortwave solar radiation (w/m2)SWNORM Terrain-normal downwelling shortwave radiation (w/m2)T2 Two-meter air temperature (deg K)U10 10-m U-component of wind velocity (m/s)V10 10m V-component of wind velocity (m/s)XLAT Latitude of grid-center point XLONG Longitude of grid-center point XTIME Model timestamp, **in UTC**

54 ENVIRONMENTAL SCIENCES↗

On the Existence of Steady-State Solutions to the Equations Governing Fluid Flow in Networks

The steady-state solution of fluid flow in pipeline infrastructure networks driven by junction/node potentials is a crucial ingredient in various decision-support tools for system design and operation. While the nonlinear system is known to have a unique solution (when one exists), the absence of a definite result on the existence of solutions hobbles the development of computational algorithms, for it is not possible to distinguish between algorithm failure and non-existence of a solution. In this letter, we show that for any fluid whose equation of state is a scaled monomial, a unique solution exists for such nonlinear systems if the term solution is interpreted in terms of potentials and flows rather than pressures and flows. However, for gases following the CNGA equation of state, while the question of existence remains open, we construct an alternative system that always has a unique solution and show that the solution to this system is a good approximant of the true solution. Further, the existence result for flow of natural gas in networks also applies to other fluid flow networks such as water distribution networks or networks that transport carbon dioxide in carbon capture and sequestration. Most importantly, our result enables correct diagnosis of algorithmic failure, problem stiffness, and non-convergence in computational algorithms.

42 ENGINEERING↗

Thermal Energy Distribution System (TEDS) Operating Modes and Control Strategies

A Thermal Energy Delivery System was constructed at the Idaho National Laboratory for demonstrating distribution of thermal energy to and from co-located systems sited in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL). DETAIL includes a flow loop simulating a pressurized water reactor, a high-temperature steam electrolysis unit and a thermal energy storage system. This report discusses the various operating modes and control strategies for enabling simultaneous, flexible and efficient transfer of heat from thermal energy sources to end users.

25 ENERGY STORAGE↗

WHOLESCALE - Water & Hole Observations Leverage Effective Stress Calculations And Lessen Expenses (Final Technical Report 2020 - 2024)

The WHOLESCALE acronym stands for Water & Hole Observations Leverage Effective Stress Calculations and Lessen Expenses. The goal of the WHOLESCALE project is to simulate the spatial distribution and temporal evolution of stress in the geothermal system at San Emidio in Nevada, United States. To reach this goal, the WHOLESCALE team has developed a methodology to incorporate and interpret data from four methods of measurement into a multi-physics model that couples thermal, hydrological, and mechanical (T H-M) processes. The WHOLESCALE team has applied this methodology at the San Emidio geothermal field, located ~100 km north of Reno, Nevada in the northwestern Basin and Range province. The WHOLESCALE team includes 30 individuals working at two universities, two national laboratories, and one industry partner. Two master-degree students and five post-doctoral researchers have gained professional experience and earned partial financial support via the WHOLESCALE project. The WHOLESCALE team has taken advantage of the perturbations created by changes in pumping operations during planned shutdowns in 2016, 2021, and 2022 to infer temporal changes in the state of stress in the geothermal system at San Emidio, Nevada, U.S. The WHOLESCALE results support the working hypothesis that increasing pore-fluid pressure reduces the effective normal stress acting across fault zones. During normal operations, pumping in deep production wells decreases fluid pressures and thus increases the effective normal stresses on faults, reducing microseismicity. During planned shutdowns, the cessation of production increases pore-fluid pressure and reduces effective normal stress. The WHOLESCALE products generated during the 4-year period between 2020 and 2024 include: three articles published in the open-access, peer-reviewed scientific literature, two master’s theses, 20 presentations or papers at scientific conferences, and 17 data sets available on public repositories. The WHOLESCALE project has been completed in two phases that included three performance periods separated by two Go/No-go Stage Gate Reviews. Tasks were classified by data type (i.e., Geologic Structure, Borehole, Geodesy, Hydrology, Seismology, and Modeling). The first phase of the project started July 31, 2020 and included ongoing project coordination (Task 1), a project kickoff (Task 2), analysis of existing data (Task 3), development of the initial stress model & deployment design (Task 4), and Go/No-go Decision Point #1 (Task 5). Phase II began with implementing the 2022 deployment (Task 6), followed by Go/No-go Decision Point #2 (Task 7) The remainder of Phase II consisted of analyzing data collected during deployment (Task 8), calibration of the stress model on all observations (Task 9), and the Final Review (August 23, 2024) & Reporting (Task 10).

15 GEOTHERMAL ENERGY↗

Transactive Emergency Power Allocation

The devastating impacts of extreme weather events, many of which are climate-change related, are increasingly evident through the frequency and duration of outages on power grids, especially the distribution systems. One of the major modern-day concerns of utilities is dealing with such extreme supply outages where operators have used rolling blackouts as a contingency plan balance supply and demand while serving critical loads. Such events have significant repercussions social and economic costs. Such blackouts practices are a blunt instrument, depriving customers with low-capacity high-priority loads (i.e. refrigeration, water, telecommunication, etc.) that provide high marginal amenity. Our contribution presented in this work is a transactive emergency allocation mechanism that would provide some minimum level of service to all of the customers while enabling preference-based trading of this initial allocation. This is in contrast to the state-of-art TE mechanisms that allocate resources to customers solely based on their willingness-to-pay. The effectiveness of the proposed mechanism is demonstrated through simulation-based evaluation on a prototypical distribution system experiencing 12-hour scarcity-based emergency event due to extreme operating conditions. Simulation results clearly demonstrate the capability of the proposed transactive emergency allocation mechanism in effectively utilizing the available energy and providing some level of service to all customers to operate their high-priority loads throughout the extreme scarcity event while being economically efficient in allowing trading of allocation based on customer preferences.

transactive energy, power system economics, emerge↗

Influence of building heat distribution temperatures on the energy performance and sizing of 5th generation district heating and cooling networks

This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Root of the matter-Impacts of harvest frequency on soil C and nutrients in switchgrass

We evaluated how harvest frequency affected plant C allocation and soil-water nutrient concentrations in a switchgrass (Panicum virgatumL.) system on the Eastern Shore of Maryland, U.S.A. Switchgrass established in 2023 was harvested once (1Cut), twice (2Cut), or three times (3Cut) during the 2024 growing season to represent potential feedstock-management regimes for anaerobic digestion. Aboveground biomass was measured at each harvest, and root biomass distribution, root C stocks, and soil properties were assessed to 60 cm after the growing season. During 2025, rainfall-synchronized soil water collected with tension lysimeters was analyzed for dissolved inorganic nitrogen (DIN) and inorganic phosphate (Pi) concentrations.

09 BIOMASS FUELS↗