A Prototype Dual Robot System to Perform Ultrasonic and Visual Inspection for the Bottom of Double-Shell Tanks - 18624

Up to this point, ultrasonic inspection-based condition data has only been available for double-shell tank (DST) sidewalls because direct inspection access to the primary tank bottom is limited to vent duct channels in an insulating refractory pad that the primary tank rests on. Probe access through the air slot would provide the opportunity to get information about the condition of the bottom of the primary tank, but it is a challenge to deploy a crawling robot that is capable of performing nondestructive ultrasonic and visual inspection through confined air slots. As such, a conceptual prototype of a deployable inspection robot system to enable ultrasonic and visual inspection for DST base through ventilation ducts was designed and fabricated. This prototype dual robot system consisting of the AnnulusBot and the MouseBot can be integrated with nondestructive evaluation (NDE) sensors to inspect and examine the physical properties of the underside of DSTs to enable status assessment. The AnnulusBot was designed to carry the MouseBot and to be deployed to the annulus space through a riser. To deploy the MouseBot to every ventilation channel in the annulus, the arm consisting of a boom and a forearm was used to place the MouseBot on the underside of the tank. The AnnulusBot used segmented wheels enable to traverse pipes and other potential obstacles. The cable management system utilized motorized wheels to feed the cable into the ventilation channel. This would reduce the amount of work that the MouseBot would have to do during inspection. This feeding mechanism would also be used to retrieve the MouseBot at the end of its inspection. Additionally, if the MouseBot fails, this mechanism would be used for retrieval. Once deployed, the MouseBot navigates to the center of the tank via the air ventilation channel beneath the inner shell (the primary tank) while inspecting the space. The MouseBot is then retrieved from the channel by a combination of its own drive power and the AnnulusBot retracting the attached umbilical cord. Compare with the AnnulusBot, the physical dimensional limitations of the MouseBot were a greater challenge. As the surface state of the concrete of the air channels could have variable texture, and may contain debris, it was decided not to travel along this surface. The ceiling of these channels is carbon steel and can be utilized throughout the channel. To use this travel surface, magnetic wheels were employed. A foreseeable problem with the use of magnets on this surface, is that they would preclude the use of eddy currents sensors. However, other technologies like ultrasonic technology sensors should be unaffected. Laboratory scale test was performed on a mock-up single wedge of the refractory pad to evaluate maneuverability of the MouseBot. The electronic components for the prototype would work in the ranges of 150-185 deg. F (65.6-85 deg. C). Both the AnnulusBot and MouseBot will be subject to constant radiation. All major printed circuit board (PCB) microcontroller components were designed to be situated outside of the annulus space and inside the main control panel to avoid radiation-induced failure. As future work, electronic components including the Arduinos that used Atmel commercial microcontrollers will be replaced with the high temperature rated Atmel microcontrollers so that the robots can be operated reliably at ambient temperatures up to 200 deg. F (93.3 deg. C). In addition, the robots will be service life tested to evaluate performance at elevated temperature and under gamma irradiation. (authors)

42 ENGINEERING↗

Progress on Advancing Robotic Ultrasonic Volumetric Inspection Technology for Hanford Under-tank Inspection - 19474

The Hanford River Protection Project is reliant on safe interim storage of high-level waste at the Hanford site and will continue to depend on it until the waste has been treated and vitrified by the Hanford Waste Treatment and Immobilization Plant (WTP). The Hanford double-shell tanks (DSTs) have provided interim storage since the DSTs were put into service (1971 - 1986) and the RPP will continue to rely on their service until least 2050, at which time the 27 in-service DSTs will be 14-54 years beyond their original design lives. As the DSTs continue to age and be operated beyond design life, reliable leak integrity assessments of primary tanks and secondary liners will become increasingly important in order to provide situational awareness to tank operations personnel and to support risk-informed decisions on the selection of DSTs as waste feed staging tanks and the order and timing of future DST refurbishment or, alternatively, DST retrieval sequence. This paper summarizes progress made in fiscal year (FY) 2018 on the engineering of a robotic air-slot volumetric inspection system (RAVIS) that is designed to perform ultrasonic (volumetric) leak integrity inspections of physically inaccessible primary tank bottom plates and welds. Leak integrity inspections performed with the RAVIS will supplement today's primary tank leak integrity inspections, which are currently limited to physically accessible sidewall plates and welds. The RAVIS will be deployed into air slots of the insulating concrete (refractory) pad beneath the primary tanks and use its ultrasonic guided wave phased-array (GWPA) sensor to electronically steer an ultrasonic beam 360-degrees around the sensor to volumetrically examine adjacent carbon steel plates and welds covered by refractory pad material. Deployments of RAVIS down multiple air-slots will be performed to determine which regions of a tank bottom have sound leak integrity or which regions are in need of future wall thickness restoration or weld repair due to pitting corrosion, general corrosion, or heat/stress-induced cracks. The initial RAVIS design and the flaw detection test results for the first air-slot GWPA sensor that was designed to fit inside the air-slots will be presented in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FITNESS-FOR-SERVICE ASSESSMENT FOR A RADIOACTIVE WASTE TANK THAT CONTAINS STRESS CORROSION CRACKS

Radioactive wastes are confined in 49 underground storage tanks at the Savannah River Site. The tanks are examined by ultrasonic (UT) methods for thinning, pitting, and stress corrosion cracking in order to assess fitness-for-service. During an inspection in 2002, ten cracks were identified on one of the tanks. Given the location of the cracks (i.e., adjacent to welds, weld attachments, and weld repairs), fabrication details (e.g., this tank was not stress-relieved), and the service history the degradation mechanism was stress corrosion cracking. Crack instability calculations utilizing API-579 guidance were performed to show that the combination of expected future service condition hydrostatic and weld residual stresses do not drive any of the identified cracks to instability. The cracks were re-inspected in 2007 to determine if crack growth had occurred. During this re-examination, one indication that was initially reported as a 'possible perpendicular crack <25% through wall' in 2002, was clearly shown not to be a crack. Additionally, examination of a new area immediately adjacent to other cracks along a vertical weld revealed three new cracks. It is not known when these new cracks formed as they could very well have been present in 2002 as well. Therefore, a total of twelve cracks were evaluated during the re-examination. Comparison of the crack lengths measured in 2002 and 2007 revealed that crack growth had occurred in four of the nine previously measured cracks. The crack length extension ranged from 0.25 to 1.8 inches. However, in all cases the cracks still remained within the residual stress zone (i.e., within two to three inches of the weld). The impact of the cracks that grew on the future service of Tank 15 was re-assessed. API-579 crack instability calculations were again performed, based on expected future service conditions and trended crack growth rates for the future tank service cycle. The analysis showed that the combined hydrostatic and weld residual stresses do not drive the identified cracks to instability. This tank expected to be decommissioned in the near future. However, if these plans are delayed, it was recommended that a third examination of selected cracks in the tank be performed in 2014.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A millimeter wave technique for measuring ice thickness on the Space Shuttle's external tank

A solution is presented for detecting and measuring ice that can form on the spray-on foam insulation protecting Space Shuttle fueltanks. The method involves the measurement of the emission properties of the fueltank with a mm-wave radiometer. Emission from the insulated panel is measured for the case of insulation with the original rough surface and the case of insulation sanded down to have a smooth surface. The radiative transfer calculations are facilitated by using a smooth surface, and experimental evidence demonstrates the effective and accurate prediction of ice thickness on the smooth surface. The panel with a rough surface is measured, and the emmision levels are higher than those predicted by model calculations. Sensitivity to ice thickness is similar in both situations in spite of the bias introduced by the rough surface.

Kendra, John E.↗

Advanced WEC Dynamics and Controls, Test 1

Numerous studies have shown that advanced control of a wave energy converter's (WEC's) power take off (PTO) can provide significant increases (on the order of 200-300%) in WEC energy absorption. Transitioning these control approaches from simplified paper studies to application in full-scale devices remains an open and extremely challenging problem will be central to creating economically competitive WECs and delivering clean renewable energy to the US electrical grid. The Advanced WEC Dynamics and Controls project is targeted on assisting WEC developers to apply novel control systems for their devices and thus achieving major increases in performance and economic viability. The success of any control strategy is based directly upon the availability of a reduced-order model with the ability to accurately capture the dynamics of the system with sufficient accuracy. A model-scale WEC was designed and fabricated for use in studies to advance the state-of-the-art in WEC controls. This test, which is the first in a series of planned tests, focused on system identification (system ID) and model validation.

16 TIDAL AND WAVE POWER↗

Dynamic Characteristics of the Partially Filled Rotating Dewar of the Gravity Probe-B Spacecraft

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a full scale Gravity Probe-B Spacecraft propellant dewar tank imposed by various frequencies of gravity jitters have been investigated. The study of the liquid-vapor interface oscillations due to various frequencies of gravity jitter under different dewar rotating speeds and different levels of background gravity have been numerically simulated. Results disclose the time sequence evolution for the excitation of large amplitude oscillation waves at the liquid-vapor interface. The study shows that slosh waves excited inside the spacecraft propellant tank are characterized by the lowest frequency of the waves initiated, frequencies of the gravity jitters imposed on the propellant system, the levels of background gravity environment, and dewar rotating speeds. Conditions for suppression and amplification of the slosh waves are discussed. It also shows that fluid stress distribution exerted on the walls of the rotating dewar are closely related to the characteristics of slosh waves excited on the liquid-vapor interface in the rotating dewar tank. This can provide a set of data leading toward the control of spacecraft imbalance caused by the uneven fluid stress distribution from slosh waves.

Hung, R. J.↗

An Experimental Investigation of Incompressible Richtmyer-Meshkov Instability

Richtmyer-Meshkov (RM) instability occurs when two different density fluids are impulsively accelerated in the direction normal to their nearly planar interface. The instability causes small perturbations on the interface to grow and eventually become a turbulent flow. It is closely related to Rayleigh-Taylor instability, which is the instability of a planar interface undergoing constant acceleration, such as caused by the suspension of a heavy fluid over a lighter one in the earth's gravitational field. Like the well-known Kelvin-Helmholtz instability, RM instability is a fundamental hydrodynamic instability which exhibits many of the nonlinear complexities that transform simple initial conditions into a complex turbulent flow. Furthermore, the simplicity of RM instability (in that it requires very few defining parameters), and the fact that it can be generated in a closed container, makes it an excellent test bed to study nonlinear stability theory as well as turbulent transport in a heterogeneous system. However, the fact that RM instability involves fluids of unequal densities which experience negligible gravitational force, except during the impulsive acceleration, requires RM instability experiments to be carried out under conditions of microgravity. This experimental study investigates the instability of an interface between incompressible, miscible liquids with an initial sinusoidal perturbation. The impulsive acceleration is generated by bouncing a rectangular tank containing two different density liquids off a retractable vertical spring. The initial perturbation is produced prior to release by oscillating the tank in the horizontal direction to produce a standing wave. The instability evolves in microgravity as the tank travels up and then down the vertical rails of a drop tower until hitting a shock absorber at the bottom. Planar Laser Induced Fluorescence (PLIF) is employed to visualize the flow. PLIF images are captured by a video camera that travels with the tank. Figure 1 is as sequence of images showing the development of the instability from the initial sinusoidal disturbance far into the nonlinear regime which is characterized by the appearance of mushroom structures resulting from the coalescence of baroclinic vorticity produced by the impulsive acceleration. At later times in this sequence the vortex cores are observed to become unstable showing the beginnings of the transition to turbulence in this flow. The amplitude of the growing disturbance after the impulsive acceleration is measured and found to agree well with theoretical predictions. The effects of Reynolds number (based on circulation) on the development of the vortices and the transition to turbulence are also determined.

Jacobs, J. W.↗

TH-CD-201-06: Experimental Characterization of Acoustic Signals Generated in Water Following Clinical Photon and Electron Beam Irradiation

Purpose: Previous work has demonstrated the detectability of acoustic waves induced following the irradiation of high density metals with radiotherapy linac photon beams. This work demonstrates the ability to experimentally detect such acoustic signals following both photon and electron irradiation in a more radiotherapy relevant material. The relationship between induced acoustic signal properties in water and the deposited dose distribution is explored, and the feasibility of exploiting such signals for radiotherapy dosimetry is demonstrated. Methods: Acoustic waves were experimentally induced in a water tank via the thermoacoustic effect following a single pulse of photon or electron irradiation produced by a clinical linac. An immersion ultrasound transducer was used to detect these acoustic waves in water and signals were read out on an oscilloscope. Results: Peaks and troughs in the detected acoustic signals were found to correspond to the location of gradients in the deposited dose distribution following both photon and electron irradiation. Signal amplitude was linearly related to the dose per pulse deposited by photon or electron beams at the depth of detection. Flattening filter free beams induced large acoustic signals, and signal amplitude decreased with depth after the depth of maximum dose. Varying the field size resulted in a temporal shift of the acoustic signal peaks and a change in the detected signal frequency. Conclusion: Acoustic waves can be detected in a water tank following irradiation by linac photon and electron beams with basic electronics, and have characteristics related to the deposited dose distribution. The physical location of dose gradients and the amount of dose deposited can be inferred from the location and magnitude of acoustic signal peaks. Thus, the detection of induced acoustic waves could be applied to photon and electron water tank and in vivo dosimetry. This work was supported in part by CIHR grants MOP-114910 and MOP-136774. S.H. acknowledges support by the NSERC CREATE Medical Physics Research Training Network grant 432290.

60 APPLIED LIFE SCIENCES↗

Modeling of wave-coherent pressures in the turbulent boundary layer above water waves

The behavior of air pressure fluctuations induced by progressive water waves generated mechanically in a laboratory tank was simulated by solving a modified Orr-Sommerfeld equation in a transformed Eulerian wave-following frame of reference. Solution is obtained by modeling the mean and wave-coherent turbulent Reynolds stresses, the behavior of which in the turbulent boundary layer above the waves was simulated using a turbulent kinetic energy-dissipation model, properly modified to account for free-surface proximity and favorable pressure gradient effects. The distribution of both the wave-coherent turbulent Reynolds stress and pressure amplitudes and their corresponding phase lags was found to agree reasonably well with available laboratory data.

Papadimitrakis, Yiannis ALEX.↗

System for Measuring Capacitance

A system has been developed for detecting the level of a liquid in a tank wherein a capacitor positioned in the tank has spaced plates which are positioned such that the dielectric between the plates will be either air or the liquid, depending on the depth of the liquid in the tank. An oscillator supplies a sine wave current to the capacitor and a coaxial cable connects the capacitor to a measuring circuit outside the tank. If the cable is very long or the capacitance to be measured is low, the capacitance inherent in the coaxial cable will prevent an accurate reading. To avoid this problem, an inductor is connected across the cable to form with the capacitance of the cable a parallel resonant circuit. The impedance of the parallel resonant circuit is infinite, so that attenuation of the measurement signal by the stray cable capacitance is avoided.

McNichol, Randal S.↗

Liquid hydrogen slosh waves excited by constant reverse gravity acceleration of geyser initiation

The requirement to settle or to position liquid fuel over the outlet end of the spacecraft propellant tank before main engine restart poses a microgravity fluid behavior problem. Resettlement or reorientation of liquid propellant can be accomplished by providing the optimal acceleration to the spacecraft such that the propellant is reoriented over the tank outlet. In this study slosh wave excitation induced by the resettling flowfield during the course of liquid reorientation with the initiation of geyser for liquid-filled levels of 30, 50, 65, 70, and 80 percent have been studied. Characteristics of slosh waves with various frequencies excited are discussed. Slosh wave excitations will affect the fluid stress distribution exerted on the container wall and shift the fluid mass distribution inside the container, which imposes the time-dependent variations in the moment of inertia of the container. This information is important for the spacecraft control during the course of liquid reorientation.

Hung, R. J.↗

SNL API-653 In-Service Tank Inspection and Evaluation Tank ID: 981-A2-T0 (West)

An API Standard 653 In-Service inspection was completed on Tank 981-A2-T0 (West) located at the Sandia National Laboratories TAIV tank farm in Albuquerque, NM on September 22, 2015. The inspection was completed to collect data to evaluate the mechanical integrity and fitness for continued service of the tank. No indication or records of any previous inspection were identified for this tank. The inspection and engineering evaluation were completed using API-653, 5 th Edition and conservative engineering practices. The tank was not removed from service, so an internal inspection could not be completed. The tank was also fully insulated. The insulation was removed in specified areas of the tank shell and tank chime to accommodate an acoustic emission scan of the tank and an ultrasonic thickness evaluation of portions of the tank. The acoustic emission scan resulted in a grade of B / I - II indicating an overall TANKPAC grade B and composite grade II indicating minor active damage with highly concentrated sources related to corrosion found in the southeast and west side section of the tank. Eight Potential Localized Damage sources were found mainly in the west side (re-test in 2 years). The tank chime could not be inspected due to the configuration of the insulation welded angle support. An ultrasonic guided bulk wave inspection was completed on the tank shell to assess the lower shell section. At the time of the inspection the limited data collected showed minimal material loss from the shell at the thickness monitoring locations, however, visual inspection and pit depth gauge measurements showed > 3/16” inch pitting and significant general external surface corrosion on the shell at the shell to floor joint. This corrosion is caused by the insulation sheeting support welded angle iron trapping moisture and dirt against the tank shell. This tank should be removed from service, internally inspected, and repaired. Ultrasonic thickness measurement locations were established on this tank and the data is included in this report. The limited data collected indicated minimal material loss at these locations, with the only noted corrosion occurring on the tank shell to floor joint as noted above. An API-653 Annex B Evaluation of Tank Bottom Settlement was completed and the results are included in this report. No significant settlement issues were identified.

42 ENGINEERING↗

Sci-Thur AM: YIS – 02: Imaging dose distributions through the detection of radiation-induced acoustic waves

Purpose: X-ray acoustic computed tomography (XACT) is an emerging technique that images the dose deposited within an object following linac irradiation by detecting acoustic waves induced via the photoacoustic effect. This work shows that XACT images can be formed in soft-tissue equivalent material and that dosimetric information can be extracted from such images. Methods: Acoustic waves induced in a water tank following irradiation by a 10 MV flattening filter free photon beam were detected with an immersion ultrasound transducer at 60 angles surrounding the radiation field. A back-projection algorithm was used to reconstruct an XACT image from the detected transducer signals. Profiles extracted from XACT images were compared to profiles measured with ion chambers as per the current clinical protocol. Results: XACT images were successfully formed of simple 4 cm × 4 cm and 6 cm × 3 cm fields, as well as of more complicated multi-leaf collimator defined fields. For the 6 cm × 3 cm field, 74% and 87% of the XACT profile points in the 6 cm and 3 cm dimensions, respectively, passed a 7% / 4 mm gamma test when compared to ion chamber measurements. In a complicated puzzle piece shaped field, 86% of the pixels in an extracted profile passed a 7% / 4 mm gamma test. Conclusions: XACT is capable of imaging the dose distribution delivered by a variety of field sizes and shapes in water, and is a viable technique for both water tank and in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗

Overview of High-Resolution Nondestructive Inspection of the Space Shuttle External Tank (ET) Spray-on-Foam Insulation (SOFI) and Acreage Heat tiles using Focused, Synthetic and Holographical Millimeter Wave Techniques

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank (ET) and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the recent Space Shuttle Discovery's flight. From immediately after the Columbia accident, microwave and millimeter wave nondestructive testing methods were considered as potential effective inspection tools for evaluating the integrity of the SOFI. To this end and as a result of these efforts, both real-focused, synthetic focusing and holographical techniques, at a wide range of frequencies covering 24 GHz to 150 GHz, have been developed for this purpose. Images of various complex SOFI panels with a wide range of embedded anomalies (representing real potential defects) have been produced using these techniques, including relatively small anomalies located near complex structural features representative of the external tank. These real-focused and 3D holographical images have effectively demonstrated the utility of these methods for SOFI inspection as being viable, robust, repeatable, simple, portable and relatively inexpensive (tens of $K as opposed to hundreds of $K). In addition, the potential viability of these methods for inspecting acreage heat tiles have has been demonstrated. This paper presents an overview of these activities, representative images of these panels using all of the imaging techniques used and a discussion of the practical attributes of these inspection methods.

Kharkovsky, S.↗

Rough-water Landings of a 0.1-Size Powered Dynamic Model of the XP5Y-1 Flying Boat with Two Types of Afterbody - Langley Tank Model 228 (TED No. NACA DE309)

A 0.1-size powered dynamic model of a large, high-speed flying boat was landed in Langley tank no. 1 into oncoming waves 4 feet high (full size). The model was tested with two afterbodies of differing lengths (4.12 and 6.63 beams). The short afterbody had a constant angle of dead rise of 22.5deg and a keel angle of 6.5deg. The long afterbody had warped dead rise and a keel angle of 8.5deg. The vertical accelerations were slightly greater and the maximum angular accelerations and maxim= trims were slightly less for the model with the long afterbody than for the model with -the short afterbody. A wave length of 210 feet (full size) imposed the highest accelerations on the model with either the long or the short afterbody.

Garrison, Charlie C.↗

Acoustic streaming jets: A scaling and dimensional analysis

We present our work on acoustic streaming free jets driven by ultrasonic beams in liquids. These jets are steady flows generated far from walls by progressive acoustic waves. As can be seen on figure 1, our set-up, denominated AStrID for Acoustic Streaming Investigation Device, is made of a water tank in which a 29 mm plane source emits continuous ultrasonic waves at typically 2 MHz. Our approach combines an experimental characterization of both the acoustic pressure field (hydrophone) and the obtained acoustic streaming velocity field (PIV visualization) on one hand, with CFD using an incompressible Navier-Stokes solver on the other hand.

42 ENGINEERING↗

Longitudinal and transverse modes of slosh wave excitation in rotating dewar associated with gravity jitters

Characteristics of slosh waves based on the dynamical behavior of oscillations at the liquid-vapor interface have been investigated. Twelve case studies of slosh wave excitation due to various frequencies of gravity jitters under different rotating speeds of the propellant tank and different levels of background gravity environment have been simulated. The study shows that slosh waves excited inside the spacecraft propellant tank are characterized by the lowest frequency of the waves initiated, frequencies of the gravity jitters imposed on the propellant system, the levels of background gravity environment, and dewar rotating speeds. Conditions for suppression and amplification of the slosh waves are discussed.

Hung, R. J.↗

Experimental Evaluation of Analytical Models for the Inertias and Natural Frequencies of Fuel Sloshing in Circular Cylindrical Tanks

A correlation is presented of experimental measurement and analytical prediction of free, planar oscillations of a tank of mercury hung on a pendulum. Measured frequencies are presented for the slosh mode and the pendulum-tank mode, and time-history wave forms are included for qualitative comparisons. The sloshing is represented analytically by a single pendulum or a spring-bob, and the size and location of their inertias are determined by matching forces and moments on the tank surface with linearized hydrodynamic theory for inviscid fluids. It is concluded that such analytical models are identical for small displacements in the present application (as they are in simpler applications) and that they provide excellent simulation of the stiffness and in ertia terms for fuel sloshing.

Warner, Robert W.↗