Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waveform sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electro-optic sampling based characterization of broad-band high efficiency THz-FEL

Extremely high beam-to-radiation energy conversion efficiencies can be obtained in a THz FEL using a strongly tapered helical undulator at the zero-slippage resonant condition, where a circular waveguide is used to match the radiation group velocity to the electron beam longitudinal velocity. In this paper we report on the first electro-optic sampling (EOS) based measurements of the broadband THz FEL radiation pulses emitted in this regime. The THz field waveforms are reconstructed in the spatial and temporal domains using multi-shot and single-shot EOS schemes respectively. The measurements are performed varying the input electron beam energy in the undulator providing insights on the complex dynamics in a waveguide FEL.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-fast hadronic calorimetry

Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations with respect to the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 2 ns providing opportunity for ultra-fast calorimetry. As a result, simulation results for an “ideal” calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FORTÉ Machine Learning

Of the non-corrupted data collected by the Orbiting Experiment (forté) satellite’s Photo-Diode Detector during the year 2001, I estimate that 7.9% of 914 894 signals are noise. My result differs dramatically from Guillen’s estimate of 96%. To arrive at this estimate, I used Gaussian mixture model (GMM) clustering–unsupervised machine learning–to aggregate the wave forms into groups based on the absolute value of the lowest 25 positive frequency discrete Fourier transform coefficients. Then, I marked several of the groups as noise by inspecting a random sampling of wave forms from each group. Marking groups as either noise or non-noise is a supervised binary classification operation. After removing the signals in noise groups from further consideration, I clustered the remaining signals into families. Again, I used a GMM, but for the familial clustering I used a Non-Negative Matrix Factorization feature vector transform. The result was 9 distinct families of lightning signals, as well as a second stage of noise filtering. To efficiently represent the entirety of the signal space, I broke each family into deciles based on their distance from the family mean. In this case, distance means the log-likelihood based on the GMM. Signals in lower deciles are more similar in shape and amplitude to their family average. I took the top 200 samples from each decile of each group, resulting in 18 000 signals. These signal approximately represent the entirety of the forté observations. To represent outliers, I also kept a zoo of the 1000 signals furthest from any family’s average. All told, the resulting data set represents the forté data with a reduction of about 51:1. To allow synthesis of an arbitrarily large number of test signals, I also captured each family’s average signal and the time-sample covariance matrix over the signals in each family. Using these two pieces of information, I can synthesize new waveforms by using a Gaussian random realization from the family average and covariance matrix. I wrote a program to test the synthesis quality. The program shows me two signals on the screen, one synthesized and one randomly drawn from the data. I attempted to identify the synthesized signal. Although the synthesis is imperfect, in an A/B comparison I only correctly chose the synthesized signal 36% of the time.

97 MATHEMATICS AND COMPUTING↗

Multi-module-based CVAE to predict HVCM faults in the SNS accelerator

We present a multi-module framework based on Conditional Variational Autoencoder (CVAE) to detect anomalies in the power signals coming from multiple High Voltage Converter Modulators (HVCMs). We condition the model with the specific modulator type to capture different representations of the $\mathcal{normal}$ waveforms and to improve the sensitivity of the model to identify a specific type of fault when we have limited samples for a given module type. We studied several Artificial Neural Network (ANN) architectures for our CVAE model and evaluated the model performance by looking at their loss landscape for stability and generalization. Our results for the Spallation Neutron Source (SNS) experimental data show that the trained model generalizes well to detecting multiple fault types for several HVCM module types. The results of this study can be used to improve the HVCM reliability and overall SNS uptime.

43 PARTICLE ACCELERATORS↗

Software for a GPS-Reflection Remote-Sensing System

A special-purpose software Global Positioning System (GPS) receiver designed for remote sensing with reflected GPS signals is described in Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System (NPO-30385), which appears elsewhere in this issue of NASA Tech Briefs. The input accepted by this program comprises raw (open-loop) digitized GPS signals sampled at a rate of about 20 MHz. The program processes the data samples to perform the following functions: detection of signals; tracking of phases and delays; mapping of delay, Doppler, and delay/Doppler waveforms; dual-frequency processing; coherent integrations as short as 125 s; decoding of navigation messages; and precise time tagging of observable quantities. The software can perform these functions on all detectable satellite signals without dead time. Open-loop data collected over water, land, or ice and processed by this software can be further processed to extract geophysical information. Possible examples include mean sea height, wind speed and direction, and significant wave height (for observations over the ocean); bistatic-radar terrain images and measures of soil moisture and biomass (for observations over land); and estimates of ice age, thickness, and surface density (for observations over ice).

Lowe, Stephen↗

CHESS 2025: Field-collected vegetation attributes and site photos

This dataset represents field observations of vegetation samples collected as part of the Colorado Headwaters Ecological Spectroscopy Study (CHESS) during June and July of 2025. Samples were collected in the field using tablet computers and digital forms, with target data differing by sample type (individual trees, individual shrubs, or 1-meter square plots of meadow and subshrub vegetation). Field samples were collected within 72 hours of airborne data collection using the National Ecological Observatory Network’s Aerial Observation Platform (NEON AOP). The NEON AOP collected waveform LiDAR (Light Detection and Ranging) and imaging spectrometer data in 426 spectral bands from the visible to shortwave infrared. Remote sensing data for the project is available on ESS-DIVE (DOI and citation to be added upon publication). Field data collected included canopy height and per-species horizontal proportional cover for meadow plots, species identity and height information for shrubs, as well as species identity, height, diameter at breast height, and health assessment information for trees. Photos of the focal site and surrounding landscape were taken for all sampling sites and are included in this archive. Green leaves or needles were collected for plant trait and foliar chemistry analysis. This data is archived separately (DOI and citation to be added upon publication). High-precision geospatial data for each sample (crown perimeter polygons for trees and shrubs, plot boundaries for meadow plots) is available here (Henderson et al., 2026). Field and remote sensing protocols largely followed those of a previous field and airborne imaging campaign performed in 2018 (described in Chadwick et al. 2020). Field data from the 2018 campaign can be found here (Chadwick et al., 2020 doi:10.15485/1618130). Because different field measurements were taken for meadow, shrub, and tree sites, data from these three sample types are archived as separate tables (chess_meadow_site_cleaned.csv, chess_shrub_site_cleaned.csv, chess_tree_site_cleaned.csv). Meadow proportional cover data is stored in a separate table (chess_meadow_cover_cleaned.csv). Taxonomy was treated identically between sample types, and the dataset shares a common set of voucher specimens (chess_voucher_IDs_cleaned.csv), as well as a single species list (chess_species_list_cleaned.csv). All taxonomic determinations were performed to the species level, and adhere to the Global Biodiversity Information Facility (GBIF) backbone taxonomy as of January 10th, 2026 (GBIF Secretariat 2023). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgment: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Integration of paper spray ionization high‐field asymmetric waveform ion mobility spectrometry for forensic applications

Rationale Paper spray ionization (PSI) is an attractive ambient ionization source for mass spectrometry (MS) since it allows the combination of surface sampling and ionization. The minimal sample preparation inherent in this approach greatly reduces the time needed for analysis. However, the ions generated from interfering compounds in the sample and the paper substrate may interfere with the analyte ions. Therefore, the integration of PSI with high‐field asymmetric ion mobility spectrometry (FAIMS) is of significant interest since it should reduce the background ions entering the mass analyzer without complicating the analysis or increasing analysis time. Here we demonstrate the integration of PSI with FAIMS/MS and its potential for analysis of samples of forensic interest. Methods In this work, the parameters that can influence the integration, including sampling and ionization by paper spray, the FAIMS separation of analytes from each other and background interferences, and the length of time that a usable signal can be observed for explosives on paper, were evaluated with the integrated system. Results In the negative ion analysis of 2,4,6‐trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), octahydro‐1,3,5,7‐tetranitro‐1,3,5,7‐tetrazocine (HMX), and 1,3,5‐trinitroperhydro‐1,3,5‐triazine (RDX), amounts as low as 1 ng on paper were readily observed. The successful positive ion separation of a set of illicit drugs including heroin, methamphetamine, and cocaine was also achieved. In addition, the positive ion analysis of the chemical warfare agent simulants dimethyl methylphosphonate (DMMP) and diisopropyl methylphosphonate (DIMP) was evaluated. Conclusions The integration of PSI‐FAIMS/MS was demonstrated for the analyses of explosives in negative ion mode and for illicit drugs and CW simulants in positive mode. Paper background ions that could interfere with these analyses were separated by FAIMS. The compensation voltage of an ion obtained by FAIMS provided an additional identification parameter to be combined with the mass spectrum for each analyte.

Tsai, Chia‐Wei↗

Experimenting Galileo on Board the International Space Station

The SCaN Testbed is an advanced integrated communications system and laboratory facility installed on the International Space Station (ISS) in 2012. The testbed incorporates a set of new generation of Software Defined Radio (SDR) technologies intended to allow researchers to develop, test, and demonstrate new communications, networking, and navigation capabilities in the actual environment of space. Qascom, in cooperation with ESA and NASA, is designing a Software Defined Radio GalileoGPS Receiver capable to provide accurate positioning and timing to be installed on the ISS SCaN Testbed. The GalileoGPS waveform will be operated in the JPL SDR that is constituted by several hardware components that can be used for experimentations in L-Band and S-Band. The JPL SDR includes an L-Band Dorne Margolin antenna mounted onto a choke ring. The antenna is connected to a radio front end capable to provide one bit samples for the three GNSS frequencies (L1, L2 and L5) at 38 MHz, exploiting the subharmonic sampling. The baseband processing is then performed by an ATMEL AT697 processor (100 MIPS) and two Virtex 2 FPGAs. The JPL SDR supports the STRS (Space Telecommunications Radio System) that provides common waveform software interfaces, methods of instantiation, operation, and testing among different compliant hardware and software products. The standard foresees the development of applications that are modular, portable, reconfigurable, and reusable. The developed waveform uses the STRS infrastructure-provided application program interfaces (APIs) and services to load, verify, execute, change parameters, terminate, or unload an application. The project is divided in three main phases. 1)Design and Development of the GalileoGPS waveform for the SCaN Testbed starting from Qascom existing GNSS SDR receiver. The baseline design is limited to the implementation of the single frequency Galileo and GPS L1E1 receiver even if as part of the activity it will be to assess the feasibility of a dual frequency implementation (L1E1+L5E5a) in the same SDR platform.2)Qualification and test the GalileoGPS waveform using ground systems available at the NASA Glenn Research Center. Experimenters can have access to two SCaN Testbed ground based systems for development and verification: the Experimenter Development System (EDS) that is intended to provide initial opportunity for software testing and basic functional validation and the Ground Integration Unit (GIU) that is a high fidelity version of the SCaN Testbed flight system and is therefore used for more controlled final development testing and verification testing.3)Perform in-orbit validation and experimentation: The experimentation phase will consists on the collection of raw measurements (pseudorange, Carrier phase, CN0) in space, assessment on the quality of the measurements and the receiver performances in terms of signal acquisition, tracking, etc. Finally computation of positioning in space (Position, Velocity and time) and assessment of its performance.(Complete abstract in attached document).

GPS↗

Experimenting Galileo on Board the International Space Station

The SCaN Testbed is an advanced integrated communications system and laboratory facility installed on the International Space Station (ISS) in 2012. The testbed incorporates a set of new generation of Software Defined Radio (SDR) technologies intended to allow researchers to develop, test, and demonstrate new communications, networking, and navigation capabilities in the actual environment of space. Qascom, in cooperation with ESA and NASA, is designing a Software Defined Radio GalileoGPS Receiver capable to provide accurate positioning and timing to be installed on the ISS SCaN Testbed. The GalileoGPS waveform will be operated in the JPL SDR that is constituted by several hardware components that can be used for experimentations in L-Band and S-Band. The JPL SDR includes an L-Band Dorne Margolin antenna mounted onto a choke ring. The antenna is connected to a radio front end capable to provide one bit samples for the three GNSS frequencies (L1, L2 and L5) at 38 MHz, exploiting the subharmonic sampling. The baseband processing is then performed by an ATMEL AT697 processor (100 MIPS) and two Virtex 2 FPGAs. The JPL SDR supports the STRS (Space Telecommunications Radio System) that provides common waveform software interfaces, methods of instantiation, operation, and testing among different compliant hardware and software products. The standard foresees the development of applications that are modular, portable, reconfigurable, and reusable. The developed waveform uses the STRS infrastructure-provided application program interfaces (APIs) and services to load, verify, execute, change parameters, terminate, or unload an application. The project is divided in three main phases. 1)Design and Development of the GalileoGPS waveform for the SCaN Testbed starting from Qascom existing GNSS SDR receiver. The baseline design is limited to the implementation of the single frequency Galileo and GPS L1E1 receiver even if as part of the activity it will be to assess the feasibility of a dual frequency implementation (L1E1+L5E5a) in the same SDR platform.2)Qualification and test the GalileoGPS waveform using ground systems available at the NASA Glenn Research Center. Experimenters can have access to two SCaN Testbed ground based systems for development and verification: the Experimenter Development System (EDS) that is intended to provide initial opportunity for software testing and basic functional validation and the Ground Integration Unit (GIU) that is a high fidelity version of the SCaN Testbed flight system and is therefore used for more controlled final development testing and verification testing.3)Perform in-orbit validation and experimentation: The experimentation phase will consists on the collection of raw measurements (pseudorange, Carrier phase, CN0) in space, assessment on the quality of the measurements and the receiver performances in terms of signal acquisition, tracking, etc. Finally computation of positioning in space (Position, Velocity and time) and assessment of its performance.(Complete abstract in attached document).

Galileo↗

A versatile X-ray phase retarder for lock-in XMCD measurements

X-ray magnetic circular dichroism (XMCD) is a technique commonly used to probe magnetic properties of materials with element and orbital selectivity, which requires the use of circularly polarized (CP) X-rays. It is possible to accomplish XMCD experiments with fixed CP and alternating the magnetic field orientation, but most reliable data are obtained when alternating the magnetization orientation and the polarization between right and left helicities. A versatile strategy has been developed to perform XMCD experiments using a hard X-ray quarter-wave plate, at both polychromatic dispersive and conventional monochromatic optics, in combination with synchronous data acquisition. The switching frequency waveform is fed into a lock-in amplifier to detect and amplify the XMCD signal. The results on a reference sample demonstrate an improvement in data quality and acquisition time. The instrumentation successfully generated 98% of CP X-rays switching the beam helicity at 13 Hz, with the possibility of faster helicity switching once it is installed at the new Brazilian fourth-generation source, SIRIUS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the Interlaminar Shear Strengths of Composites

Acousto-ultrasonic technique utilizing computer and waveform digitizer developed for nondestructive evaluation (NDE) of composite materials. Technique employed on filament-wound composite (FWC) specimens cut from sample segments of graphite/epoxy cylinders. Developed for use on large composite structures to verify integrity and assure reusability. Similar applications of technique anticipated for variety of composite structures, such as pipelines and storage tanks.

Kautz, Harold E.↗

Development of a Laser Ultrasonics-based Approach for Rapid Screening of High Entropy Alloys

This project utilized a laser ultrasonic technique to systematically study temperature-induced evolution of material properties in a set of interrelated binary alloys and a high entropy alloy (HEA) fabricated using arc-melting and spark plasma sintering processes. This technique involved the use of a nanosecond duration, high-intensity pulsed laser to thermo-elastically generate ultrasonic waves that propagate in the bulk of the metal alloy. Sub-nanometer-scale displacements associated with the propagating bulk ultrasonic waves were detected along the epicenter on the opposite surface of the sample using a 1 GHz bandwidth photorefractive interferometer. Phase transformations and microstructural changes were inferred from the temperature-dependent trends in the bulk acoustic velocities and features in the ultrasonic epicentral waveforms measured in the binary alloys. These inferences were then correlated with electron/optical microscopy observations and predictions using calculations of phase diagrams (CALPHAD). The results showed that the laser-generated ultrasonic pulses were strongly influenced by changes in material microstructure and could accurately track thermally driven phase transformations and detect the presence of microscale heterogeneities (grain boundaries, dendritic structures, etc.) in the set of binary alloy samples. The measurement approach was then applied to a quinary HEA sample for estimating phase transition temperature and determining microstructural heterogeneity. The rapid, non-contact and non-destructive ultrasonic testing approach demonstrated here is amenable to high throughput combinatorial investigations that can be applied to graded composition HEAs produced using advanced manufacturing methods. When paired with atomistic simulations and CALPHAD modeling, this approach can overcome the bottlenecks faced by current material characterization methods in efficiently screening the vast discovery space of HEAs that spans over a hundred million unique quinary alloy compositions.

36 MATERIALS SCIENCE↗

Expanded interleaved solid-state memory for a wide bandwidth transient waveform recorder

An interleaved, solid state expanded memory for a 100 MHz bandwidth waveform recorder is described. The memory development resulted in a significant increase in the storage capacity of a commercially available recorder. The motivation for the memory expansion of the waveform recorder, which is used to support in-flight measurement of the electromagnetic characteristics of lightning discharges, was the need for a significantly longer data window than that provided by the commercially available unit. The expanded recorder provides a data window that is 128 times longer than the commercial unit, while maintaining the same time resolution, by increasing the storage capacity from 1024 to 131 072 data samples. The expanded unit operates at sample periods as small as 10 ns. Sampling once every 10 ns, the commercial unit records for about 10 microseconds before the memory is filled, whereas, the expanded unit records for about 1300 microseconds. A photo of the expanded waveform recorder is shown.

Thomas, R. M., Jr.↗

A frozen Gaussian approximation-based multi-level particle swarm optimization for seismic inversion

In this paper, we propose a frozen Gaussian approximation (FGA)-based multi-level particle swarm optimization (MLPSO) method for seismic inversion of high-frequency wave data. The method addresses two challenges in it: First, the optimization problem is highly non-convex, which makes hard for gradient-based methods to reach global minima. This is tackled by MLPSO which can escape from undesired local minima. Second, the character of high-frequency of seismic waves requires a large number of grid points in direct computational methods, and thus renders an extremely high computational demand on the simulation of each sample in MLPSO. We overcome this difficulty by three steps: First, we use FGA to compute high-frequency wave propagation based on asymptotic analysis on phase plane; Then we design a constrained full waveform inversion problem to prevent the optimization search getting into regions of velocity where FGA is not accurate; Last, we solve the constrained optimization problem by MLPSO that employs FGA solvers with different fidelity. The performance of the proposed method is demonstrated by a two-dimensional full-waveform inversion example of the smoothed Marmousi model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent pulse interrogation system for fiber Bragg grating sensing of strain and pressure in dynamic extremes of materials

A 100 MHz fiber Bragg grating (FBG) interrogation system is described and applied to strain and pressure sensing. The approach relies on coherent pulse illumination of the FBG sensor with a broadband short pulse from a femtosecond modelocked erbium fiber laser. After interrogation of the FBG sensor, a long multi-kilometer run of single mode fiber is used for chromatic dispersion to temporally stretch the spectral components of the reflected pulse from the FBG sensor. Dynamic strain or pressure induced spectral shifts in the FBG sensor are detected as a pulsed time domain waveform shift after encoding by the chromatic dispersive line. Signals are recorded using a single 35 GHz photodetector and a 50 G Samples per second, 25 GHz bandwidth, digitizing oscilloscope. Application of this approach to high-speed strain sensing in magnetic materials in pulsed magnetic fields to ~150 T is demonstrated. The FBG wavelength shifts are used to study magnetic field driven magnetostriction effects in LaCoO₃. A sub-microsecond temporal shift in the FBG sensor wavelength attached to the sample under first order phase change appears as a fractional length change (strain: ΔL/L<10⁻⁴) in the material. A second application used FBG sensing of pressure dynamics to nearly 2 GPa in the thermal ignition of the high explosive PBX-9501 is also demonstrated. Both applications demonstrate the use of this FBG interrogation system in dynamical extreme conditions that would otherwise not be possible using traditional FBG interrogation approaches that are deemed too slow to resolve such events.

36 MATERIALS SCIENCE↗

Controllable high voltage source having fast settling time

A high voltage dc stepping power supply for sampling a utilization device such as an electrostatic analyzer has a relatively fast settling time for voltage steps. The supply includes a waveform generator for deriving a low voltage staircase waveform that feeds a relatively long response time power supply, deriving a high output voltage generally equal to a predetermined multiple of the input voltage. In the power supply, an ac voltage modulated by the staircase waveform is applied to a step-up transformer and then to a voltage multiplier stack to form a high voltage, relatively poor replica of the input waveform at an intermediate output terminal. A constant dc source, applied to the input of the power supply, biases the voltage at the intermediate output terminal to be in excess of the predetermined multiple of the input voltage.

Doong, H.↗

On the validation of seismic imaging methods: Finite frequency or ray theory?

Abstract We investigate the merits of the more recently developed finite‐frequency approach to tomography against the more traditional and approximate ray theoretical approach for state of the art seismic models developed for western North America. To this end, we employ the spectral element method to assess the agreement between observations on real data and measurements made on synthetic seismograms predicted by the models under consideration. We check for phase delay agreement as well as waveform cross‐correlation values. Based on statistical analyses on S wave phase delay measurements, finite frequency shows an improvement over ray theory. Random sampling using cross‐correlation values identifies regions where synthetic seismograms computed with ray theory and finite‐frequency models differ the most. Our study suggests that finite‐frequency approaches to seismic imaging exhibit measurable improvement for pronounced low‐velocity anomalies such as mantle plumes.

58 GEOSCIENCES↗