Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wearables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Overview of MSFC Additive Electronics Capabilities

Focus: Marshall seeks to support the Agency in the development of next generation printed electronics technologies for living and working in space, with emphasis on enhanced electronics manufacturing processes and capabilities development on the ground and in-space. Near-Term: Human Habitation Elements and Life Support Systems - pursuing integrated flexible wearable air, water, vital monitoring solutions for next generation printed technologies; Complete startup printing technology demonstrations which prove basic processes and establish ISM (In-Space Manufacturing) infrastructure needed for future applications including metals based manufacturing. Medium Term: Target low-cost research and demonstration activities that support multi-material additive manufacturing, more sophisticated parts production, printed electronics and ISM; Maturation and flight demonstration of printed propulsion system components, with emphasis on infusion into small-spacecraft-based missions. Long-Term: Evolve systems capabilities to be supportive of destination (lunar or Mars) resources and requirements, increase autonomy in systems and utilize in-situ resources towards manufacturing; Support development of self-replicable systems and their infusion into future spacecraft and missions.

MacLeod, Todd C.↗

Biosensor Integration Development ExMC/Canadian Space Agency Collaboration

In support of the NASA Human Research Program Exploration Medical Capability (ExMC) Element, NASA Ames Research Center (ARC) established a collaborative effort with the Canadian Space Agency (CSA). The collaboration focuses on leveraging CSA capability in the areas of biosensors and decision support that will augment future development of such components for Exploration Missions. The CSA advancement of biosensors enables NASA to focus on the integration and data management associated with these types of components through the system currently under development by the Medical Data Architecture (MDA) project. This approach has enabled the establishment of a successful collaborative working relationship between ExMC and CSA.Applying lessons learned from the fiscal year 2016 (FY16) Human Exploration Research Analog (HERA) campaign, CSA and NASA ARC developed a solution to provide real-time feedback to researchers who monitor the collection of vital signs data from a wearable Astroskin garment. The advances in the interfaces included the development of an iPad application (by CSA) to wirelessly forward the vital signs data to the MDA system, which collected the vital signs data through a receiver developed by NASA ARC. The development of these interfaces aims to provide communications between the Astroskin and the MDA system such that data may be seamlessly collected, stored and retrieved by the MDA. The first steps towards this goal were demonstrated in FY16. In FY17, ExMC will complete the first in a series of test beds that establishes a system to automate collection and management of vital sign data from the Astroskin, and other sources of data, to provide information for a crewmember to make medical decisions. In addition, the MDA Test Bed 1 will enable CSA to evaluate and optimize biosensor advancement and facilitate decision support algorithm development.

Vital signs↗

Biosensor Integration Development ExMC/Canadian Space Agency Collaboration

In support of the NASA Human Research Program Exploration Medical Capability (ExMC) Element, NASA Ames Research Center (ARC) established a collaborative effort with the Canadian Space Agency (CSA). The collaboration focuses on leveraging CSA capability in the areas of biosensors and decision support that will augment future development of such components for Exploration Missions. The CSA advancement of biosensors enables NASA to focus on the integration and data management associated with these types of components through the system currently under development by the Medical Data Architecture (MDA) project. This approach has enabled the establishment of a successful collaborative working relationship between ExMC and CSA.Applying lessons learned from the fiscal year 2016 (FY16) Human Exploration Research Analog (HERA) campaign, CSA and NASA ARC developed a solution to provide real-time feedback to researchers who monitor the collection of vital signs data from a wearable Astroskin garment. The advances in the interfaces included the development of an iPad application (by CSA) to wirelessly forward the vital signs data to the MDA system, which collected the vital signs data through a receiver developed by NASA ARC. The development of these interfaces aims to provide communications between the Astroskin and the MDA system such that data may be seamlessly collected, stored and retrieved by the MDA. The first steps towards this goal were demonstrated in FY16. In FY17, ExMC will complete the first in a series of test beds that establishes a system to automate collection and management of vital sign data from the Astroskin, and other sources of data, to provide information for a crewmember to make medical decisions. In addition, the MDA Test Bed 1 will enable CSA to evaluate and optimize biosensor advancement and facilitate decision support algorithm development.

Astroskin↗

Variable Vector Countermeasure Suit (V2Suit) for Space Habitation and Exploration

The Variable Vector Countermeasure Suit (V2Suit) for Space Habitation and Exploration is a visionary system concept that will revolutionize space missions by providing a platform for integrating sensors and actuators with daily astronaut intravehicular activities to improve human health and performance. The V2Suit uses control moment gyroscopes (CMGs) within a miniaturized module placed on body segments to provide a viscous resistance during movements _ a countermeasure to the sensorimotor and musculoskeletal adaptation performance decrements that manifest themselves while living and working in microgravity and during gravitational transitions during long-duration spaceflight, including post-flight recovery and rehabilitation. Through an integrated design, system initialization, and control systems approach the V2Suit is capable of generating this viscous resistance along an arbitrarily specified direction of down. When movements are made, for example, parallel to that down direction a resistance is applied, and when the movement is perpendicular to that direction no resistance is applied. The V2Suit proposes to be a countermeasure to this spaceflight-related adaptation and de-conditioning and the unique sensorimotor characteristics associated with living and working in 0-G, which are critical for future long-duration space missions. This NIAC Phase II project leveraged the study results from Phase I and focused on detailing several aspects of the V2Suit concept, including a wearable CMG architecture, control steering laws, human-system integration evaluations, developing a brassboard prototype unit as a proof-of-concept, as well as evaluating the concept in the context of future space exploration missions. A human mission to Mars, such as that outlined in the Mars Design Reference Architecture 5.0, provides a framework for determining the concept of operations and requirements for the V2Suit system. Mars DRA 5.0 includes approximately 180 day 0-G transits to- and from- Mars, as well as a 500 day stay on the surface (~3/8-G) (Figure 3). Accordingly, there are four gravitational transitions associated with this mission: 1-G to 0-G (Earth launch), 0-G to 3/8-G (Mars landing), 3/8-G to 0-G (Mars launch), and 0-G to 1-G (Earth landing). This reference mission provided the basis for developing high-level operational requirements to guide the subsequent study and design of the key V2Suit components.

Duda, Kevin R.↗

Characterization and Measurement of Spacecraft Airborne Particulate Matter

The International Space Station (ISS) gives a 6-member astronaut crew the ability to live and work in low Earth orbit. It is a unique indoor environment, which has served as both home and workplace to over 230 people since the year 2000. In this low gravity environment, smoke does not rise and cookie crumbs do not settle the way they do on Earth, causing airborne particulate matter, or aerosols, to behave differently and pose unique hazards for crew members. In its existence, virtually the same volume of ISS air has been continuously conditioned and ‘revitalized,’ including the removal of particles by filtration. While gaseous constituents of ISS air are monitored meticulously, sparse data exists on the indoor aerosols. The quantity and types of ISS airborne debris have been investigated in NASA’s Aerosol Sampling Experiment. Both active and passive samplers successfully collected airborne particulate matter in U.S. segments of the ISS, which were returned to Earth for characterization by microscopy and other techniques. The resulting data has informed the design of candidate particle instruments for spacecraft. In 2020, a reference-quality aerosol instrument will be flown to ISS, and will provide real-time data of particle concentrations in various modules. Smaller, more compact instruments will be necessary in future space missions, for example, in smaller vehicles, in habitats on lunar and planetary surfaces with ubiquitous dust, and also for use as wearable technology throughout missions. Miniaturized aerosol sensors, though lower fidelity than reference-quality instruments, can monitor the environment well when calibrated appropriately. Indoor air quality in spacecraft is fundamentally important to human health and comfort, and several particulate monitoring technologies will be at sufficient technology readiness levels for operational use within the next two years. Results of the Aerosol Sampling Experiment will be presented, along with the status of NASA’s aerosol instrument technology demonstrations on ISS.

Meyer, Marit E.↗

Mitigations to Reduce the Law of Unintended Consequences for Autonomy and Other Technological Advances

The United Nations states that Earth’s population is expected to reach just under 10 billion people (9.7) by the year 2050. To meet the demands of 10 billion people, governments, multinational corporations and global leaders are relying on autonomy and technological advances to augment and/or accommodate human efforts to meet the required needs of daily living. Genetically modified organisms (GMOs), Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR) gene-edited plants and cloning will be utilized to expand human food supply. Biomimetic implants are expected to improve life expectancy with 3D printed body parts. Human functioning will be extended with wearables and cybernetic implants continuing humanity’s path toward transhumanism. Families will be strengthened with 3 parent households. Disease will surely be eradicated using the CRISPR-CAS9 genetic engineering revolution to design out undesirable human traits and to design in new capabilities. With autonomous cars, trucks and buses on our roads and on-demand autonomous aircraft delivering pizzas, medical prescriptions and groceries in the air and multi-planet vehicles traversing space, utopia will finally arrive! Or will it? All of these powerful, man-made, technological systems will experience unintended consequences with certainty. Instead of over-reacting with hysteria and fear, we should be seeking answers to the following questions - “What skills are required to architect socially-healthy technological systems for 2050?” “What mindsets should we embody to ameliorate hubris syndrome and to build our future technological systems with deliberation, soberness and social responsibility?”

Morris, A. Terry↗

Motion Sickness and Concerns for Urban Air Mobility Vehicles: A Literature Review

Motion sickness is a general term for a constellation of signs and symptoms, generally due to exposure to abrupt, periodic, or unnatural accelerations, especially when traveling in a vehicle. Motion sickness results from a mismatch of the visual and nonvisual (vestibular and kinesthetic) information, the observed scene and the motion felt or lack of it. Motion sickness onset is associated with a pattern of physiological changes in heart rate, peripheral blood flow, respiration, and skin conductance and the pattern is repeatable for a particular subject but variable between subjects. Demographic factors such as gender and age that affect motion sickness are well known with children, women, and older adults more likely to be susceptible. Often motion sickness is assessed and quantified using variations of the motion sickness susceptibility questionnaires including the Pensacola Diagnostic Rating Scale and the Simulator Sickness Questionnaire. Even though symptoms are easily identified by such questionnaires, they commonly are subjective. Tools such as these questionnaires for screening individuals susceptible to motion sickness are useful, however, they are only mildly predictive. Moreover, models for predicting motion sickness, which have largely been developed for sea sickness, do not consider task characteristics. Predictions of motion sickness rates and prevalence for Urban Air Mobility (UAM) vehicles are not possible at present because data from actual flight or full-fidelity simulation are simply not yet available. Extrapolation from other modes of transportation (i.e., automobiles, buses, trains, boats, other types of aircraft) is difficult because of differences in the motion stimulus experienced, trip duration, and other factors. How UAM vehicles will change the social dynamics of passenger interaction and vehicle interior design changes (e.g., seat orientations) is unknown. Should motion sickness prove to be an issue, vehicle design modifications such as having passengers face forward, providing additional seat recline, giving each person their own climate control for airflow, perhaps ensuring the horizon is visible to all passengers (reducing visual occlusion by the headrest) and visually stabilizing displays on carry-on devices (smart phones, tablets, etc.) may benefit passengers. Several commercial companies provide wearable devices for physiological monitoring that have been validated and are suitable for use with passengers in UAM vehicles or high-fidelity simulators. Potential countermeasures for motion sickness include user-worn devices, anti-motion sickness medications, and non-pharmacological approaches such as biofeedback and Autogenic Feedback Training Exercise. Both simulator and in-vehicle UAM research is needed to evaluate the effectiveness of any potential countermeasure.

motion sickness↗

Sweating the Small Stuff: A Sensor for Real-Time Neuro-Immune Axis Monitoring

Although manageable with certain precautions, circadian rhythm misalignment and sleep disturbances pose a potential threat to astronaut health. It is well-known that sleep is essential for proper immunological and neurological functioning, while impairments in these functions result in risks for spaceflight success. Neuropeptides and hormones are involved in regulating the circadian clock and are used as biomarkers for circadian alignment. However, in-flight monitoring of these biomarkers is limited due to the lack of real-time sensor systems and sample collection/processing confines. Therefore, real-time measurements of biomarkers in-flight are necessary for mission success and crew health. For this, a robust biomarker involved in the neuro-immune axis of circadian rhythm cycling, physiological stress responses, and inflammation would be well-received as a viable biomarker for assessing physiological health for crew during long-duration missions, as these are currently NASA Human Research Program defined risks. Therefore, this paper describes the development of a wearables we at biosensor to measure the biological clock neuropeptide, orexin/hypocretin. Additionally, potential for implementation of a user-friendly sensor of orexin/hypocretin to be telemetrically reported in real-time, is proposed. In brief, the proposed system has the possibility to be used as a biomarker monitor to support preventive and personalized medicine.

Amber M Paul↗

Process Development for Printing Copper Conductible Ink on Flexible Substrates Using Aerosol Jet Technology

Rise in demand for wearable consumer electronics products has given an impetus to the development of flexible electronics technology encompassing flexible substrates and compatible circuitry. Also, additive manufacturing of flexible electronics is emerging rapidly via several techniques such as Inkjet and Aerosol Jet Printing (AJP). The basic component of all flexible circuits to be printed by these technologies is conductible ink, which is generally silver ink. Few studies exist on the printing of copper conductible ink and not many copper ink formulations are available in the market as that of silver inks. This study aims to develop a process development study for deposition of copper conductible lines on flexible substrates using the aerosol jet printing technology. The process development study includes investigation of photosintering parameters for obtaining desirable electrical resistance and shear load to failure values for the printed line. Different pre-drying techniques such as oven pre-drying and platen pre-drying have been used for improving the electrical and mechanical properties of the conductive traces. Techniques such as optical microscopy and white light interferometry have been used for the characterization of print quality of the conductible lines.

printed electronics↗

Vertically Aligned Graphene/Metal Oxide Based Lightweight Super Strong, Energy Storage Carbon Fiber Composites

In this era of budding smart technologies, flexible and smart wearable textiles are a long awaited product which are anticipated to reach a $10 B market in few years.1 Supercapacitors are an excellent power source for these smart textiles, because they are light in weight, safe in operation, provide longer life cycle, high flexibility, and faster charge discharge capabilities.

Energy storage↗

Scientific Physical and Operations Characterization (SPOC): Studying Scientists in the Wild to Inform Human Planetary Exploration Operations

The objective of the Scientific Physical and Operational Characterization (SPOC) project is to build an evidence-based description of terrestrial field science to inform the operational, physical, and tool requirements for planetary exploration extravehicular activities (xEVAs). EVAs of the future, including Artemis 2024 and beyond, intend to promote scientific productivity (e.g., LEAG science goals)[1]; however, no clear, objective pathway currently exists to enable this goal, particularly with respect to the desired increase in autonomy imparted to future astronauts. The SPOC project applies expertise in the fields of cognitive systems engineering [2-5], biomechanics, wearable sensors [6-8] and hardware/software to more targetly address these issues. In doing so, a terrestrial fieldwork ground-truth can be established that will benefit human and robotic exploration of other planetary surfaces.

M J Miller↗

Print-Consistency and Process-Interaction for Inkjet-Printed Copper on Flexible Substrate

Printed electronics is a fastest growing and emerging technology that have shown much potential in several industries including automotive, wearables, healthcare, and aerospace. Its applications can be found not only in flexible but also in large area electronics. The technology provides an effective and convenient method to additively deposit conductive and insulating materials on any type of substrate. Comparing with traditional manufacturing processes, which involves chemical etching, this technology also comes to be relatively environmental friendly. Despite its status, it is not without its challenges. Starting from the material being compatible in the printer equipment to the point of achieving fine resolutions, and with excellent properties are some of the challenges that printed electronics face. Among the myriad of printing technologies such as Aerosol Jet, micro-dispensing, gravure printing, screen printing, Inkjet printing, Inkjet has gained much attention due to its low-cost, low material consumption, and roll-to-roll capability for mass manufacturing. The technology has been widely used in home and office, but recently gained interest in printed electronics in a research and development setting. Conductive materials used in Inkjet printing generally comprises of metal Nanoparticles that need to be thermally sintered for it to be conductive. The preferred metal of choice has been mostly silver due to its excellent electrical properties and ease in sintering. However, silver comes to be expensive than its counterpart copper. Since copper is prone to oxidation, much focus has been given towards photonic sintering that involves sudden burst of pulsed light at certain energy to sinter the copper Nanoparticles. With this technique, only the printed material gets sintered in a matter of seconds without having a great impact on its substrate, due to which it is also preferred in low temperature applications. With all the knowledge, there is still a large gap in the process side with copper where it is important to look how the print process affects the resolution of the print along with the effect of post-print processes on electrical and mechanical properties. In this paper, a copper Inkjet ink is utilized for understanding the effect of Inkjet print parameters on the ejected droplet and its resolution. Post-print process is also quantified using a photonic sintering equipment for excellent electrical and mechanical properties. To demonstrate the complete process, commercial-off-the-shelf components will also be mounted on the additively printed pads via Inkjet. Statistically, control charting technique will be utilized to understand the capability of the Inkjet process.

printed electronics↗

Configuration and Projected Capabilities of the Common Habitat Medical Care Facility

The Common Habitat is a large, long-duration habitat being explored as part of a conceptual study (not an active NASA program) that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. Additional work outside the scope of this paper is developing a vertical translation system, a crew mobility aids system based on wearable gecko-derived grippers, and a crew seating/restraint system. These systems are all assumed for use in conjunction with the Medical Care Facility, which is needed to maintain crew well-being during these missions, where distance from Earth precludes the possibility of evacuation to Earth. This paper describes recent improvements in the Common Habitat Medical Care Facility and associated benefits for crew survivability in long duration missions beyond Earth orbit. These improvements were made with the assistance of a NASA Pathways intern whose experience includes a tour of duty in Afghanistan as an Army combat medic with the 691st GHOST-T, attached to the 1st and 7th US Special Forces Groups as part of Operation Freedom’s Sentinel, where he helped provide far-forward surgical capabilities in austere combat environments. The initial baseline Medical Care Facility was developed working in conjunction with University of Houston Space Architecture graduate students. The facility was placed on the upper deck of the Common Habitat in a location that provided privacy, operational volume, and was close to the vertical translation pathway. The notional outfitting repurposed component CAD models from unrelated studies and notionally indicated a level of care roughly equivalent to that aboard the International Space Station. The CAD modeling provided notional stowage volumes, a deployable surface, some fixed equipment, an ultrasound, and a potentially reconfigurable treatment table. While this facility is clearly a competent arrangement, it was desired to leverage available expertise and upgrade the station given the vast distances from Earth to be experienced by the Common Habitat. Key driving requirements applied to the upgrade included to provide Medical Level of Care V, offer enhanced telemedicine capabilities, provide patient physical accommodation, provide caregiver access to the patient from all sides, include sliding pocket doors for access to hygiene and to the Vertical Translation System, and to add any additional capability possible for the best achievable medical care. The first step in the facility upgrade was to quantify the current medical inventory on the International Space Station and ensure that sufficient stowage volume was present for this purpose. To that end, the ISS medical kits were reviewed, and eight full size mid deck lockers were placed in the facility. A number of additional devices were also added, based on the intern’s combat medic experience. Also, two fixed shelves and one horizontal work surface were added to the Medical Care Facility, with the shelves providing storage space for the additional devices and the work surface providing a location for the caregiver to work or stage equipment. Four display monitors were added to the wall above the horizontal work surface, supporting data display, telemedicine, conferencing, or other needs. The existing treatment table was replaced with a mobile surgical stretcher-chair. Two additional doors were added to the Medical Care Facility. One leads directly to the hygiene compartment, allowing it to support medical operations in addition to providing galley/wardroom support. The other door leads directly into the Vertical Translation System. The wall adjacent to the subsystems bay was moved, adding additional volume to the Medical Care Facility. This improved caregiver access to the patient and allowed for a larger number of caregivers to be present. It also provided options for relocation of support equipment relative to the patient as needed. In the upgraded Medical Care Facility, the Surgical Stretcher-Chair and the Vertical Translation System can work together to provide incapacitated crew member transport from a site of injury on any deck of the Common Habitat to the Medical Care Facility. It can also support patient treatment in a variety of positions including a variety of sitting postures and a supine posture at a variety of pitch angles. The facility can also support caregiver office work for review of examination results, private consultation, inventory and maintenance, and a variety of other purposes. A forward activity will be to conduct evaluations of the Medical Care Facility with different medical scenarios. Additionally, ambient and task lighting selections remain as forward work. The eight mid deck lockers can be augmented to use as portable equipment carts, similar to a manner in which maintenance facility stowage was used as portable carts during the NASA Desert Research and Technology Studies in the Constellation Program. Trash accommodation will also need forward work to assess, including provision for wet trash, dry trash, and biological waste. It will be important to assess a redesign of the surgical stretcher-chair. The commercial version used in the upgrade can only enable vertical translation in the seated configuration, requiring the patient to bend both hips and knees. A possible redesign of the chair will allow for vertical translation without requiring any bending at the hip or knees. Also, the commercial version is wheeled, making it mobile in gravity but unanchored in microgravity. Work will be needed to adapt the chair for gravity-independent performance. The hygiene compartment can be redesigned for dual-use medical scrub and galley handwash facility. Pending sufficient volume, it may also be possible to place sanitation equipment in this location to clean medical tools. Finally, most space architectures have never allowed for more than one incapacitated crew member, but several scenarios could potentially injure two or more crew in the same incident. This facility could be assessed to determine its present ability to address two or more injured crew in parallel and determine the potential upper limit for number of treatable crew in a multi-crew injury scenario, or to treat polytrauma of a single patient.

Habitat↗

Kinetically Tunable, Active Auxetic, and Variable Recruitment Active Textiles from Hierarchical Assemblies

Multifunctional textiles with programmable, multi-axial, distributed, and scalable actuation are highly desirable and presently unrealized. 1D torque-unbalanced active yarns within 2D textile structures are exploited to produce soft and scalable active textiles that exhibit tunable displacements, forces, stiffnesses, and kinematic deformations. Through a textile hierarchy spanning active material composition, yarn construction, textile geometry, and system architecture, these active textiles accomplish kinetic tunability, variable recruitment behaviors, and auxetic effects without mechanical contact, called active auxetic effects. New modes of pre-programmed multi-axial performance are enabled by geometrically manipulating—specifically pre-stressing and constraining—active filaments in torsion and leveraging their structural elastic instability within a textile geometry. The new kinematic motion afforded by torque-unbalanced active yarns enhances the performance of active textiles, which accomplish tensile strokes over 40%, generated blocked forces up to 308 N m−1, and specific work over 0.4. kJ kg−1. Advances in active textiles are demonstrated through multifunctional 3D applications, including a variable constriction pump that exhibits sequential actuation, a wearable that conforms multi-axially around the body, and a soft exoskeleton that performs assistive motions and on-body anchoring simultaneously. By harnessing the capabilities of active materials within a textile hierarchy, advances in the potentiality of multifunctional textiles are presented.

Active auxetic effects↗

The Chain-link Actuator: Exploiting the Bending Stiffness of McKibben Artificial Muscles to Achieve Larger Contraction Ratios

McKibben artificial muscles, comprised of an ex-pandable bladder wrapped in a double-helix-braided sheath,have the ability to generate forces without restricting motion tooccur exclusively along the direction of actuation. This makesthem attractive for a variety of applications including soft,wearable, and biomimetic robots. Despite their advantages, thetheoretical maximum contraction ratio of McKibben muscles isonly 36.3%, which restricts the range of motion of the systemsthey actuate. This work introduces a novel ‘chain-link actuator’that exploits the bending stiffness of McKibben muscles toachieve contraction ratios of more than 50%. A static modelthat captures the relationship between pressure, displacement,and force is presented and validated on several real chain-linkactuator systems.

Daniel Bruder↗

How Autonomous Intelligent Systems Can Facilitate Earth-independent Medical Care: Going Beyond Telepresence

During the last decade, teleoperated robotic systems have extended humans’ sensorimotor competence to digitally fly beyond the physical barrier of distance and scale and thus transmit sensorimotor skills of the human through direct communication. Telepresence capabilities have enabled tele-physical remote access at small scales thanks to telerobotic mediums. Although the concept was initially motivated by space applications, such technologies quickly have expanded into the medical domain and resulted in teleoperated medical robots, including telerobotic surgical systems (such as the da Vinci surgical system). Effective telepresence fundamentally depends on an agile, reliable, and secure communication medium that can transmit real-time information between the operator and a remote device. However, direct telepresence may not be achievable for long-duration exploration spaceflight missions. Thus, autonomous systems and local intelligence represent potential solutions to the aforementioned issues. One example solution employs demonstration systems which enable learning from the pre-captured inputs of a skilled human operator. These will be computationally modeled and later probabilistically replicated toward the completion of remote physical tasks when direct telepresence is not viable - such as under communication blackout conditions. In other words, trained autonomous systems (e.g., robots) can perform remote operations that mimic the physical performance of experts during remote operations/training. Beyond learning the physics of the task, autonomous agents can also be used to conduct algorithmic decision-making that mimics the higher-level cognition of the expert. Thus, using an autonomous system, pre-trained cognitive and manipulation-based skills can be leveraged (acquired during pre-mission events) to produce digital twins of an intelligent operator. Such systems can be used for the real-time conduction of intricate tasks in complex and unstructured environments. Such systems will operationalize “cognitive digital twins” and can expand the reach of human cognition and manipulation through the power of data-driven learning from demonstration algorithms. This system category will be discussed as a fully autonomous operation in this talk. In addition to the above, we will also propose and discuss the possibility of partial-automation using remote intelligence and remote sensing. In contrast to full automation, partial automation can close the loop through a local operator equipped with augmented sensory awareness through wearable systems. Such technologies will allow the local operator to conduct delicate tasks while being guided using sensory augmentation and being monitored to gauge her/his level of cognitive focus and performance. The difference with the previous category is that a remote human will conduct the task. Further, rather than making a digital twin of human cognition, we will augment the control inputs of the local human to match those of the skilled expert operator who is not accessible in real-time. Going beyond classic telepresence and thus approaching intelligent telepresence, our vision is that autonomous agents will eventually enable the safe, consistent and efficient delivery of complex, remote and smart medical care during space exploration across operators in an Earth-independent fashion. We will discuss our collective vision from NASA and MERIIT@NYU lab in this talk.

Telepresence↗

Configuration and Projected Capabilities of the Common Habitat Medical Care Facility

The Common Habitat is a large, long-duration habitat being explored as part of a conceptual study (not an active NASA program) that uses an SLS core stage Liquid Oxygen (LOX) tank as its primary structure. It is intended for use on the Moon as part of a permanently occupied outpost, on Mars as part of an outpost that will be occupied for hundreds of days at a time, and in deep space as part of the Deep Space Exploration Vehicle where it will support crewed missions up to 1200 days in duration. A study of internal orientation and crew size resulted in a Common Habitat configuration sized for a crew of eight with a three-deck horizontal orientation. Additional work outside the scope of this paper is developing a vertical translation system, a crew mobility aids system based on wearable gecko-derived grippers, and a crew seating/restraint system. These systems are all assumed for use in conjunction with the Medical Care Facility, which is needed to maintain crew well-being during these missions, where distance from Earth precludes the possibility of evacuation to Earth. This paper describes recent improvements in the Common Habitat Medical Care Facility and associated benefits for crew survivability in long duration missions beyond Earth orbit. These improvements were made with the assistance of a NASA Pathways intern whose experience includes a tour of duty in Afghanistan as an Army combat medic with the 691st GHOST-T, attached to the 1st and 7th US Special Forces Groups as part of Operation Freedom’s Sentinel, where he helped provide far-forward surgical capabilities in austere combat environments. The initial baseline Medical Care Facility was developed working in conjunction with University of Houston Space Architecture graduate students. The facility was placed on the upper deck of the Common Habitat in a location that provided privacy, operational volume, and was close to the vertical translation pathway. The notional outfitting repurposed component CAD models from unrelated studies and notionally indicated a level of care roughly equivalent to that aboard the International Space Station. The CAD modeling provided notional stowage volumes, a deployable surface, some fixed equipment, an ultrasound, and a potentially reconfigurable treatment table. While this facility is clearly a competent arrangement, it was desired to leverage available expertise and upgrade the station given the vast distances from Earth to be experienced by the Common Habitat. Key driving requirements applied to the upgrade included to provide NASA’s Medical Level of Care V, offer enhanced telemedicine capabilities, provide patient physical accommodation, provide caregiver access to the patient from all sides, include sliding pocket doors for access to hygiene and to the Vertical Translation System, and to add any additional capability possible for the best achievable medical care. The first step in the facility upgrade was to quantify the current medical inventory on the International Space Station and ensure that sufficient stowage volume was present for this purpose. To that end, the ISS medical kits were reviewed, and eight full size mid deck lockers were placed in the facility. A number of additional devices were also added, based on the co-author’s combat medic experience. Also, two fixed shelves and one horizontal work surface were added to the Medical Care Facility, with the shelves providing storage space for the additional devices and the work surface providing a location for the caregiver to work or stage equipment. Four display monitors were added to the wall above the horizontal work surface, supporting data display, telemedicine, conferencing, or other needs. The existing treatment table was replaced with a mobile surgical stretcher-chair. Two additional doors were added to the Medical Care Facility. One leads directly to the hygiene compartment, allowing it to support medical operations in addition to providing galley/wardroom support. The other door leads directly into the Vertical Translation System. The wall adjacent to the subsystems bay was moved, adding additional volume to the Medical Care Facility. This improved caregiver access to the patient and allowed for a larger number of caregivers to be present. It also provided options for relocation of support equipment relative to the patient as needed. In the upgraded Medical Care Facility, the Surgical Stretcher-Chair and the Vertical Translation System can work together to provide incapacitated crew member transport from a site of injury on any deck of the Common Habitat to the Medical Care Facility. It can also support patient treatment in a variety of positions including a variety of sitting postures and a supine posture at a variety of pitch angles. The facility can also support caregiver office work for review of examination results, private consultation, inventory and maintenance, and a variety of other purposes. A forward activity will be to conduct evaluations of the Medical Care Facility with different medical scenarios. Additionally, ambient and task lighting selections remain as forward work. The eight middeck lockers can be augmented to use as portable equipment carts, similar to a manner in which maintenance facility stowage was used as portable carts during the NASA Desert Research and Technology Studies in the Constellation Program. Trash accommodation will also need forward work to assess, including provision for wet trash, dry trash, and biological waste. It will be important to assess a redesign of the surgical stretcher-chair. The commercial version used in the upgrade can only enable vertical translation in the seated configuration, requiring the patient to bend both hips and knees. A possible redesign of the chair will allow for vertical translation without requiring any bending at the hip or knees. Also, the commercial version is wheeled, making it mobile in gravity but unanchored in microgravity. Work will be needed to adapt the chair for gravity-independent performance. The hygiene compartment can be redesigned to serve both as a medical scrub facility and for galley hand washing. Pending sufficient volume, it may also be possible to place sanitation equipment in this location to clean medical tools. Finally, most space architectures have never allowed for more than one incapacitated crew member, but several scenarios could potentially injure two or more crew in the same incident. This facility could be assessed to determine its present ability to address two or more injured crew in parallel and determine the potential upper limit for number of treatable crew in a multi-crew injury scenario, or to treat polytrauma of a single patient.

Common Habitat↗