Search NASA⌕ Search

SEARCH · Search NASA

Results for “XRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A novel instrument for quantitative nanoanalytics involving complementary X-ray methodologies

A novel ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation has been constructed and commissioned. This versatile instrument was developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, a rotational and translational movement of several photodiodes as well as a translational movement of an aperture system in and out of the beam is provided. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-ray fluorescence analysis (XRF), total-reflection XRF, grazing-incidence XRF in addition to optional X-ray reflectometry measurements or polarization-dependent X-ray absorption fine structure analyses. With this instrument samples having a size of up to 100 mm Multiplication-Sign 100 mm can be analyzed with respect to their mass deposition, elemental or spatial composition, or the species in order to probe surface contamination, layer composition and thickness, the depth profile of matrix elements or implants, the species of nanolayers, nanoparticles or buried interfaces as well as the molecular orientation of bonds. Selected applications of this advanced ultra-high vacuum instrument demonstrate both its flexibility and capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron based X-ray fluorescence activities at Indus-2: An overview

X-Ray fluorescence (XRF) spectrometry is a powerful non-destructive technique for elemental analysis of materials at bulk and trace concentration levels. Taking into consideration several advantages of the synchrotron based XRF technique and to fulfill the requirements of Indian universities users we have setup a microfocus XRF beamline (BL-16) on Indus-2 synchrotron light source. The beamline offers a wide range of usages – both from research laboratories and industries; and for researchers working in diverse fields. A brief overview of the measured performance of the beamline, design specifications including various attractive features and recent research activities carried out on the BL-16 beamline are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A flexible setup for angle-resolved X-ray fluorescence spectrometry with laboratory sources

X-ray fluorescence (XRF) analysis is one of the standard tools for the analysis of stratified materials and is widely applied for the investigation of electronics and coatings. The composition and thickness of the layers can be determined quantitatively and non-destructively. Recent work showed that these capabilities can be extended towards retrieving stratigraphic information like concentration depth profiles using angle-resolved XRF (ARXRF). This paper introduces an experimental sample chamber which was developed as a multi-purpose tool enabling different measurement geometries suited for transmission measurements, conventional XRF, ARXRF, etc. The chamber was specifically designed for attaching all kinds of laboratory X-ray sources for the soft and hard X-ray ranges as well as various detection systems. In detail, a setup for ARXRF using an X-ray tube with a polycapillary X-ray lens as source is presented. For such a type of setup, both the spectral and lateral characterizations of the radiation field are crucial for quantitative ARXRF measurements. The characterization is validated with the help of a stratified validation sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural analysis of bioceramic materials for denture application

Structural analysis has been performed on bioceramic materials for denture application by using X-ray diffraction (XRD), X-ray fluorescence (XRF), and Scanning Electron Microscopy (SEM). XRF is using for analysis chemical composition of raw materials. XRF shows the ratio 1 : 1 : 1 : 1 between feldspar, quartz, kaolin and eggshell, respectively, resulting composition CaO content of 56.78 %, which is similar with natural tooth. Sample preparation was carried out on temperature of 800 °C, 900 °C and 1000 °C. X-ray diffraction result showed that the structure is crystalline with trigonal crystal system for SiO{sub 2} (a=b=4.9134 Å and c=5.4051 Å) and CaH{sub 2}O{sub 2} (a=b=3.5925 Å and c=4.9082 Å). Based on the Scherrer’s equation showed the crystallite size of the highest peak (SiO{sub 2}) increase with increasing the temperature preparation. The highest hardness value (87 kg/mm{sup 2}) and match with the standards of dentin hardness. The surface structure was observed by using SEM also discussed.

36 MATERIALS SCIENCE↗

A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extremely soft X-ray flash as the indicator of off-axis orphan GRB afterglow

We verified the off-axis jet model of X-ray flashes (XRFs) and examined a discovery of off-axis orphan gamma-ray burst (GRB) afterglows. The XRF sample was selected on the basis of the following three factors: (1) a constraint on the lower peak energy of the prompt spectrum E{sub obs}{sup src}, (2) redshift measurements, and (3) multicolor observations of an earlier (or brightening) phase. XRF 020903 was the only sample selected on the basis of these criteria. A complete optical multicolor afterglow light curve of XRF 020903 obtained from archived data and photometric results in the literature showed an achromatic brightening around 0.7 days. An off-axis jet model with a large observing angle (0.21 rad, which is twice the jet opening half-angle, θ{sub jet}) can naturally describe the achromatic brightening and the prompt X-ray spectral properties. This result indicates the existence of off-axis orphan GRB afterglow light curves. Events with a larger viewing angle (>∼2θ{sub jet}) could be discovered using an 8 m class telescope with wide-field imagers such as the Subaru Hyper-Suprime-Cam and the Large Synoptic Survey Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

Structural and chemical ordering of Heusler C o x M n y G e z epitaxial films on Ge (111): Quantitative study using traditional and anomalous x-ray diffraction techniques

Epitaxial films of C o x M n y G e z grown on Ge (111) substrates by molecular-beam-epitaxy techniques have been investigated as a continuous function of composition using combinatorial synchrotron x-ray diffraction (XRD) and x-ray fluorescence (XRF) spectroscopy techniques. A high-resolution ternary epitaxial phase diagram is obtained, revealing a small number of structural phases stabilized over large compositional regions. Ordering of the constituent elements in the compositional region near the full Heusler alloy C o 2 MnGe has been examined in detail using both traditional XRD and a new multiple-edge anomalous diffraction (MEAD) technique. Multiple-edge anomalous diffraction involves analyzing the energy dependence of multiple reflections across each constituent absorption edge in order to detect and quantify the elemental distribution of occupation in specific lattice sites. Results of this paper show that structural and chemical ordering are very sensitive to the Co : Mn atomic ratio, such that the ordering is the highest at an atomic ratio of 2 but significantly reduced even a few percent off this ratio. The in-plane lattice is nearly coherent with that of the Ge substrate, while the approximately 2% lattice mismatch is accommodated by the out-of-plane tetragonal strain. The quantitative MEAD analysis further reveals no detectable amount (<0.5%) of Co-Mn site swapping, but instead high levels (26%) of Mn-Ge site swapping. Increasing Ge concentration above the Heusler stoichiometry ( C o 0.5 M n 0.25 G e 0.25 ) is shown to correlate with increased lattice vacancies, antisites, and stacking faults, but reduced lattice relaxation. The highest degree of chemical ordering is observed off the Heusler stoichiometry with a Ge enrichment of 5 at.%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Selenium Accumulation, Distribution, and Speciation in Spineless Prickly Pear Cactus: A Drought- and Salt-Tolerant, Selenium-Enriched Nutraceutical Fruit Crop for Biofortified Foods

The organ-specific accumulation, spatial distribution, and chemical speciation of selenium (Se) were previously unknown for any species of cactus. We investigated Se in Opuntia ficus-indica using inductively coupled plasma mass spectrometry, microfocused x-ray fluorescence elemental and chemical mapping ({micro}XRF), Se K-edge x-ray absorption near-edge structure (XANES) spectroscopy, and liquid chromatography-mass spectrometry (LC-MS). {micro}XRF showed Se concentrated inside small conic, vestigial leaves (cladode tips), the cladode vasculature, and the seed embryos. Se K-edge XANES demonstrated that approximately 96% of total Se in cladode, fruit juice, fruit pulp, and seed is carbon-Se-carbon (C-Se-C). Micro and bulk XANES analysis showed that cladode tips contained both selenate and C-Se-C forms. Inductively coupled plasma mass spectrometry quantification of Se in high-performance liquid chromatography fractions followed by LC-MS structural identification showed selenocystathionine-to-selenomethionine (SeMet) ratios of 75:25, 71:29, and 32:68, respectively in cladode, fruit, and seed. Enzymatic digestions and subsequent analysis confirmed that Se was mainly present in a 'free' nonproteinaceous form inside cladode and fruit, while in the seed, Se was incorporated into proteins associated with lipids. {micro}XRF chemical mapping illuminated the specific location of Se reduction and assimilation from selenate accumulated in the cladode tips into the two LC-MS-identified C-Se-C forms before they were transported into the cladode mesophyll. We conclude that Opuntia is a secondary Se-accumulating plant whose fruit and cladode contain mostly free selenocystathionine and SeMet, while seeds contain mainly SeMet in protein. When eaten, the organic Se forms in Opuntia fruit, cladode, and seed may improve health, increase Se mineral nutrition, and help prevent multiple human cancers.

54 ENVIRONMENTAL SCIENCES↗

Abridged spectral matrix inversion: parametric fitting of X-ray fluorescence spectra following integrative data reduction

Recent improvements in both X-ray detectors and readout speeds have led to a substantial increase in the volume of X-ray fluorescence data being produced at synchrotron facilities. This in turn results in increased challenges associated with processing and fitting such data, both temporally and computationally. Herein an abridging approach is described that both reduces and partially integrates X-ray fluorescence (XRF) data sets to obtain a fivefold total improvement in processing time with negligible decrease in quality of fitting. The approach is demonstrated using linear least-squares matrix inversion on XRF data with strongly overlapping fluorescent peaks. This approach is applicable to any type of linear algebra based fitting algorithm to fit spectra containing overlapping signals wherein the spectra also contain unimportant (non-characteristic) regions which add little (or no) weight to fitted values, e.g. energy regions in XRF spectra that contain little or no peak information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ROI-Finder : machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy

The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NanoSIMS analysis of arsenic and selenium in cereal grain

Cereals are an important source of selenium (Se) to humans and many people have inadequate intakes of this essential trace element. Conversely, arsenic (As) is toxic and may accumulate in rice grain at levels that pose a health risk. Knowledge of the localization of selenium and arsenic within the cereal grain will aid understanding of their deposition patterns and the impact of processes such as milling. High-resolution secondary ion mass spectrometry (NanoSIMS) was used to determine the localization of Se in wheat (Triticum aestivum) and As in rice (Oryza sativa). Combined synchrotron X-ray fluorescence (S-XRF) and NanoSIMS analysis utilized the strengths of both techniques. Selenium was concentrated in the protein surrounding the starch granules in the starchy endosperm cells and more homogeneously distributed in the aleurone cells but with Se-rich hotspots. Arsenic was concentrated in the subaleurone endosperm cells in association with the protein matrix rather than in the aleurone cells. NanoSIMS indicated that the high intensity of As identified in the S-XRF image was localized in micron-sized hotspots near the ovular vascular trace and nucellar projection. This is the first study showing subcellular localization in grain samples containing parts per million concentrations of Se and As. There is good quantitative agreement between NanoSIMS and S-XRF.

59 BASIC BIOLOGICAL SCIENCES↗

Focused‐beam X‐ray fluorescence and diffraction microtomographies for mineralogical and chemical characterization of unsectioned extraterrestrial samples

Abstract This study describes the application of new synchrotron X‐ray fluorescence (XRF) and diffraction (XRD) microtomographies for the 3‐D visualization of chemical and mineralogical variations in unsectioned extraterrestrial samples. These improved methods have been applied to three compositionally diverse chondritic meteorite samples that were between 300 and 400 μm in diameter, including samples prepared from fragments of the CR2 chondrite LaPaz Icefield (LAP) 02342, H5 chondrite MacAlpine Hills (MAC) 88203, and the CM2 chondrite Murchison. The synchrotron‐based XRF and XRD tomographies used are focused‐beam techniques that measure the intensities of fluorescent and diffracted X‐rays in a sample simultaneously during irradiation by a high‐energy microfocused incident X‐ray beam. Measured sinograms of the emitted and diffracted intensities were then tomographically reconstructed to generate 2‐D slices of XRF and XRD intensity through the sample, with reconstructed pixel resolution of 1–2 μm, defined by the resolution of the focused incident X‐ray beam. For sample LAP 02342, primary mineral phases that were visualized in reconstructed slices using these techniques included isolated grains of α‐Fe, orthopyroxene, and olivine. For our sample of MAC 88203, XRF/XRD tomography allowed visualization of forsteritic olivine as a primary mineral phase, a vitrified fusion crust at the sample surface, identification of localized Cr‐rich spinels at spatial resolutions of several micrometers, and imaging of a plagioclase‐rich glassy matrix. In the sample of Murchison, major identifiable phases include clinoenstatite‐ and olivine‐rich chondrules, variable serpentine matrix minerals and small Cr‐rich spinels. Most notable in the tomographic analysis of Murchison is the ability to quantitatively distinguish and visualize the complex mixture of serpentine‐group minerals and associated tochilinite–cronstedtite intergrowths. These methods provide new opportunities for spatially resolved characterization of sample texture, mineralogy, crystal structure, and chemical state in unsectioned samples. This provides researchers an ability to characterize such samples internally with minimal disruption of sample micro‐structures and chemistry, possibly without the need for sample extraction from some types of sampling and capture media.

Geochemistry & Geophysics↗

In vivo nucleic acid detection and imaging within whole plants using plasmonic nanosensors

The ability to monitor gene expression within living plants is of importance in many applications ranging from plant biology research to biofuel development; however, no method currently exists without requiring sample extraction. Herein, we report a multimodal imaging method based on plasmonic nanoprobes for in vivo imaging and biosensing of microRNA biotargets within whole plant leaves. This method integrates three different but complementary techniques: surfaceenhanced Raman scattering (SERS), X-ray fluorescence (XRF), and plasmonics-enhanced two-photon luminescence (TPL). The multimodal method utilizes plasmonic nanostars, which not only provide large Raman signal enhancement, but also allow for localization and quantification by XRF and plasmonics-enhanced TPL, owing to gold content and high two-photon luminescence cross-sections. For the sensing mechanism, inverse molecular sentinel (iMS) nanoprobes are used for SERS bioimaging of microRNA within Arabidopsis thaliana leaves to provide a dynamic SERS map of detected microRNA targets while also quantifying nanoprobe concentrations using XRF and TPL. This report lays the foundation for the use of plasmonic nanoprobes for in vivo functional imaging of nucleic acid biotargets in whole plants, a tool that will allow the study of these biotargets with previously unmet spatial and temporal resolution.

bioimaging↗

Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

Yang, B.↗

Distribution and Speciation of Nutrient Elements around Micropores

In Australia a class of soils known as duplex soils covers approximately 20% of the continent. Their defining characteristic is a sharp texture contrast between the A (or E) and B horizon. The upper B horizon at the point of contact with the E horizon is often highly sodic and of such a high strength that root growth and proliferation, water conductivity, aeration, water storage, and water uptake are restricted. Roots growing in these soils rely on channels created by previous roots or cracks arising from shrink-swell forces associated with seasonal wetting and drying. Although the characteristics of rhizospheres compared with the soil matrix are well documented there is a paucity of knowledge about how long these changes persist after roots decay. This knowledge is fundamental to our understanding of root growth in duplex soils in which plants rely on pore networks formed by previous plants to proliferate in the subsoil. In this study we investigated the heterogeneous chemistry of micropores in situ using synchrotron-based {mu}-x-ray fluorescence spectroscopy (XRF), {mu}-x-ray absorption near edge structure spectroscopy (XANES), and extended {mu}-x-ray absorption fine structure spectroscopy (EXAFS). The distribution maps of Ca, Mn, Fe, Cu, and Zn at micrometer resolution were collected using {mu}-XRF. Subsequently, specific locations with higher concentrations (hot spots) of Mn, Fe, Cu, or Zn were selected and XANES and EXAFS spectra were collected to study the speciation of these elements around the micropore compared with the soil matrix. The {mu}-XRF maps showed that Mn was depleted around one of the micropores studied but accumulated around another micropore. Copper and Zn accumulated around the micropores, whereas Ca was predominantly inside micropores. There was no difference between matrix and micropore surface with respect to the distribution of Fe. Around micropores Mn was present in reduced form (Mn II) and Fe was in its oxidized form (Fe III). Manganese and Cu were present in the form of phosphates, Fe as Fe oxides, and Zn as Zn phosphates and adsorbed Zn.

54 ENVIRONMENTAL SCIENCES↗

Quantitative analysis of concrete using portable x-ray fluorescence: Method development and validation

During Decommissioning and Demolition (D&D) activities at SRS, it is important that the building be screened for radionuclides and heavy metals to ensure that the proper safety and disposal metrics are in place. A major source of contamination at DOE facilities is the accumulation of mercury contamination, from nuclear material processing and Liquid Waste System (LWS). This buildup of mercury could possibly cause harm to any demolition crew or the environment should this material be released. The current standard method is to take core samples in various places in the facility and use X-ray fluorescence (XRF) to detect the contamination. This standard method comes with a high financial value due to the security levels of these sample facilities with unknown contamination levels. Here in we propose the use of portable XRF units to detect for this contamination on-site. To validate this method, the instrument has to be calibrated to detect the heavy metal contamination, be both precise with the known elemental concentrations and consistent with its actual results of a sample concrete and pristine contaminant, and be able to detect changes in the sample concrete’s composition. After receiving the various concrete samples with their compositions found by a XRF wave-dispersive method, the calibration factor’s linear regressions were adjusted to give the baseline concentration of the concrete with no contamination. Samples of both concrete and concrete/flyash were evaluated; their standard deviations revealed that the measurements were consistent with the known composition. Finally, the samples were contaminated with different concentrations of sodium tungsten dihydrate, allowed to air dry, and measured. When the contaminated samples were analyzed, the heavy metal contamination was seen within the spectrum of the instrument, but there was not a trend of quantification based on the concentration of the solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solvent Hold Tank Sample Results for MCU-19-2-3-4 (January 2019), MCU-19-83-84-85 (February 2019), MCU-19-208-209-210 (March 2019) and MCU-19-138-139-140 (March special trim): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples (MCU-19-2-3-4, MCU-19-83-84-85, MCU-19-208-209-210); and a set from a special trim (MCU-19-138-139-140) are reported. Most of the conclusions are based on the March SHT sample (MCU-18-208-209-210). Analyses of the March SHT sample (MCU-19-208-209-210) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L, respectively) by 3% and 6%, respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has increased since the January 2019 measurement to 1141 mg/L, which is above the minimum recommended concentration (479 mg/L). These new concentrations are consistent with the concentrations observed when MCU was fully operational in 2016. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the January sample and consistently detected in the February and March samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the March SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.55E5 dpm/mL) measured in the March 2019 SHT samples was consistent with previous values observed when MCU was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias (a statistical difference at 5% level) between the FT-HNMR and HPLC methods when measuring the MaxCalix and Modifier concentration; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was also detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗