Search NASA⌕ Search

SEARCH · Search NASA

Results for “absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments

The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers are considered the gold standard because of their precision, availability, and relative ease of use. This study evaluates and compares 5 different ionization chambers: phantom combinations for verification in routine patient-specific quality assurance of RapidArc treatments. Fifteen different RapidArc plans conforming to the clinical standards were selected for the study. Verification plans were then created for each treatment plan with different chamber-phantom combinations scanned by computed tomography. This includes Medtec intensity modulated radiation therapy (IMRT) phantom with micro-ionization chamber (0.007 cm{sup 3}) and pinpoint chamber (0.015 cm{sup 3}), PTW-Octavius phantom with semiflex chamber (0.125 cm{sup 3}) and 2D array (0.125 cm{sup 3}), and indigenously made Circular wax phantom with 0.6 cm{sup 3} chamber. The measured isocenter absolute dose was compared with the treatment planning system (TPS) plan. The micro-ionization chamber shows more deviations when compared with semiflex and 0.6 cm{sup 3} with a maximum variation of -4.76%, -1.49%, and 2.23% for micro-ionization, semiflex, and farmer chambers, respectively. The positive variations indicate that the chamber with larger volume overestimates. Farmer chamber shows higher deviation when compared with 0.125 cm{sup 3}. In general the deviation was found to be <1% with the semiflex and farmer chambers. A maximum variation of 2% was observed for the 0.007 cm{sup 3} ionization chamber, except in a few cases. Pinpoint chamber underestimates the calculated isocenter dose by a maximum of 4.8%. Absolute dose measurements using the semiflex ionization chamber with intermediate volume (0.125 cm{sup 3}) shows good agreement with the TPS calculated among the detectors used in this study. Positioning is very important when using smaller volume chambers because they are more sensitive to geometrical errors within the treatment fields. It is also suggested to average the dose over the sensitive volume for larger-volume chambers. The ionization chamber-phantom combinations used in this study can be used interchangeably for routine RapidArc patient-specific quality assurance with a satisfactory accuracy for clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of various methods for rectum delineation on relative and absolute dose-volume histograms for prostate IMRT treatment planning

Several reports have dealt with correlations of late rectal toxicity with rectal dose-volume histograms (DVHs) for high dose levels. There are 2 techniques to assess rectal volume for reception of a specific dose: relative-DVH (R-DVH, %) that indicates relative volume for a vertical axis, and absolute-DVH (A-DVH, cc) with its vertical axis showing absolute volume of the rectum. The parameters of DVH vary depending on the rectum delineation method, but the literature does not present any standardization of such methods. The aim of the present study was to evaluate the effects of different delineation methods on rectal DVHs. The enrollment for this study comprised 28 patients with high-risk localized prostate cancer, who had undergone intensity-modulated radiation therapy (IMRT) with the prescription dose of 78 Gy. The rectum was contoured with 4 different methods using 2 lengths, short (Sh) and long (Lg), and 2 cross sections, rectum (Rec) and rectal wall (Rw). Sh means the length from 1 cm above the seminal vesicles to 1 cm below the prostate and Lg the length from the rectosigmoid junction to the anus. Rec represents the entire rectal volume including the rectal contents and Rw the rectal volume of the area with a wall thickness of 4 mm. We compared dose-volume parameters by using 4 rectal contour methods for the same plan with the R-DVHs as well as the A-DVHs. For the high dose levels, the R-DVH parameters varied widely. The mean of V{sub 70} for Sh-Rw was the highest (19.4%) and nearly twice as high as that for Lg-Rec (10.4%). On the contrary, only small variations were observed in the A-DVH parameters (4.3, 4.3, 5.5, and 5.5 cc for Sh-Rw, Lg-Rw, Sh-Rec, and Lg-Rec, respectively). As for R-DVHs, the parameters of V{sub 70} varied depending on the rectal lengths (Sh-Rec vs Lg-Rec: R = 0.76; Sh-Rw vs Lg-Rw: R = 0.85) and cross sections (Sh-Rec vs Sh-Rw: R = 0.49; Lg-Rec vs Lg-Rw: R = 0.65). For A-DVHs, however, the parameters of Sh rectal A-DVHs hardly changed regardless of differences in rectal length at all dose levels. Moreover, at high dose levels (V{sub 70}), the parameters of A-DVHs showed less dependence on rectal cross sections (Sh-Rec vs Sh-Rw: R = 0.66; Lg-Rec vs Lg-Rw: R = 0.59). This study showed that A-DVHs were less dependent on the delineation methods than R-DVHs, especially for evaluating the rectal dose at higher dose levels. It can therefore be assumed that, in addition to R-DVHs, A-DVHs can be used for evaluating rectal toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absolute Branching Ratios of Prominent $γ$ Rays Following $α$ Decay of 233 U

The absolute $γ$-ray branching ratios (emission probabilities) for 19 prominent peaks in the $α$ decay of 233 U are reported with energies ranging from 97 to 366 keV. The branching ratios were obtained from $α-γ$ coincidence measurements, normalized to the $α$ singles. The high-purity 233 U material (> 99.98%) was separated from its decay products before preparation of a 4.74-mg/cm 2 uranyl nitrate foil with a 6-mm diameter. Furthermore, this is the first report on the absolute normalization of the branching ratios since 1984 and it is the only measure by $α-γ$ coincidences, where the $α-γ/α$ ratio removes several potential systematic biases. Overall, the results are consistent with the adopted literature, and they validate the quantities most relevant to the non-destructive assay of fissile 233 U material, which is relevant to the thorium fuel cycle and associated safeguards.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Online, Absolute Quantitation of Propranolol from Spatially Distinct 20- and 40-μm Dissections of Brain, Liver, and Kidney Thin Tissue Sections by Laser Microdissection–Liquid Vortex Capture–Mass Spectrometry

Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20 μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d 7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d 7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The H•/H– Redox Couple and Absolute Hydration Energy of H–

A supermolecule-continuum approach with water clusters up to n = 16 H2O molecules has been used to predict the absolute hydration free energies at 298 K ($\Delta$G hyd ) of both hydrogen (H•) and hydride (H - ) to be 4.6 and -78 ± 2 kcal/mol, respectively. These values are combined with a high accuracy prediction of the gas phase electron affinity ($\Delta$G gas,298K = -16.9 kcal/mol) to determine the aqueous electron affinity of H• of 99.5 ± 2 kcal/mol, which yields a reduction potential for H• vs SHE of -0.03 ± 0.15 V. This value is in agreement within 0.2 V with most estimates obtained using a wide variety of approaches. The results of this study can be used to improve the absolute hydricity scale in water which provides additional insights into how a putative hydride interacts with solvent, but do not change the ability to predict the relative reactivity of two species using relative hydricity scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absolute Photoionization Cross Section of the Simplest Enol, Vinyl Alcohol

The absolute photoionization cross section of vinyl alcohol was determined by multiplexed photoionization mass spectrometry of the Norrish type II photodissociation of butanal at 308 nm. The measured cross sections at 10.005 and 10.205 eV are 7.5 ± 1.9 MB and 8.1 ± 1.9 MB respectively. Here, a higher signal-to-noise ratio photoionization spectrum of vinyl alcohol was recorded via the pyrolysis of 2-chloroethanol and scaled to the absolute cross sections measured using the Norrish type II method. From comparison of our spectrum with previously reported photoelectron spectra we conclude that vinyl alcohol is mainly ionized by direct ionization in the energy range 9 – 9.6 eV, whereas autoionization is responsible for the steady rise in the photoionization spectrum above the end of the Franck-Condon envelope at 9.9 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing Absolute Orientations in DNA Self-Assembly of Single Molecules

DNA self-assembly of single molecules (i.e., dyes) with deterministic orientations is a powerful approach for engineering mo-lecular excitons. However, current determination methods of the dye orientation relative to DNA do not account for the orien-tation of the dye plane, which is a missing degree of freedom needed to define absolute three-dimensional orientations. In this work, we combine fluorescence-detected linear dichroism, defocused dipole imaging, and DNA points accumulation for imaging in nanoscale topography (DNA-PAINT) super-resolution microscopy to determine the absolute three-dimensional orientations of single Cy5 dyes relative to host DNA duplexes which includes the dye plane orientation. The data revealed that the absorption and emission dipoles are perpendicular to the DNA duplex, and the mean dye plane is parallel to the DNA bases, which supports the notion that Cy5 dyes intercalate between DNA base pairs. The presented methodology will inspire the investigation of the dye plane orientation for controlling dye arrangement configurations beyond spontaneous π-stacking between dyes as well as achieving novel dye-DNA arrangements.

36 MATERIALS SCIENCE↗

Absolute Molecular Orientation of Isopropanol at Ceria (100) Surfaces: Insight into Catalytic Selectivity from the Interfacial Structure

The initial mechanistic steps underlying heterogeneous chemical catalysis can be described in a framework where the composition, structure, and orientation of molecules adsorbed to reactive interfaces are known. However, extracting this vital information is the limiting step in most cases due in part to challenges in probing the interfacial monolayer with enough chemical specificity to characterize the surface molecular constituents. These challenges are exacerbated at complex or spatially heterogeneous interfaces where competing processes and a distribution of local environments can uniquely drive chemistry. To address these limitations, this work presents a distinctive combination of materials synthesis, surface specific optical experiments, and theory to probe and understand molecular structure at catalytic interfaces. Specifically, isopropanol was adsorbed to surfaces of the model CeO 2 catalyst that were synthesized with only the (100) facet exposed. Vibrational sum-frequency generation was used to probe the molecular monolayer, and with the guidance of density functional theory calculations, was used to extract the structure and absolute molecular orientation of isopropanol at the CeO 2 (100) surface. Our results show that isopropanol is readily deprotonated at the surface, and through the measured absolute molecular orientation of isopropanol, we obtain new insight into the selectivity of the (100) surface to form propylene. Our findings reveal key insight into the chemical and physical phenomena taking place at pristine interfaces thereby pointing to intuitive structural arguments to describe catalytic selectivity in more complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Absolute Redox Potentials of Ferrocene in the Condensed Phase

Absolute thermodynamic quantities for critical chemical reactions are needed to determine the role of solvents and reactive environments in catalysis and electrocatalysis beyond the relative scales typically employed. In principle, theoretical methods can provide such quantification but are often hindered by the innate complexity of strong electron correlation and dynamic relaxation of solvent environments. Here, we present and validate a protocol for calculating the redox potentials of ferrocene/ferrocenium redox pair in the acetonitrile. Equation-of-motion ionization potential coupled-cluster single-double (EOM-IP-CCSD) and effective fragment potential (EFP) methods are used to characterize the adiabatic and vertical ionization potentials (IP) as well as the electron affinity processes. We benchmark molecular mechanics against the EFP model to show the differences in ferrocene electronic polarizability in two redox states. Our best estimate of the redox potential (4.94 eV) agrees well with the experimental value (4.93 eV). This demonstrated the ability of modern computational methods to predict absolute redox potentials quantitatively and, more critically, quantify the correlation of dynamic effects, which underlie their origin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Free Energy Perturbation Hamiltonian Replica-Exchange Molecular Dynamics (FEP\H-REMD) for absolute ligand binding free energy calculations.

Free Energy Perturbation with Replica Exchange Molecular Dynamics (FEP/REMD) offers a powerful strategy to improve the convergence of free energy computations. In particular, it has been shown previously that a FEP/REMD scheme allowing random moves within an extended replica ensemble of thermodynamic coupling parameters '{lambda}' can improve the statistical convergence in calculations of absolute binding free energy of ligands to proteins [J. Chem. Theory Comput. 2009, 5, 2583]. In the present study, FEP/REMD is extended and combined with an accelerated MD simulations method based on Hamiltonian replica-exchange MD (H-REMD) to overcome the additional problems arising from the existence of kinetically trapped conformations within the protein receptor. In the combined strategy, each system with a given thermodynamic coupling factor {lambda} in the extended ensemble is further coupled with a set of replicas evolving on a biased energy surface with boosting potentials used to accelerate the interconversion among different rotameric states of the side chains in the neighborhood of the binding site. Exchanges are allowed to occur alternatively along the axes corresponding to the thermodynamic coupling parameter {lambda} and the boosting potential, in an extended dual array of coupled {lambda}- and H-REMD simulations. The method is implemented on the basis of new extensions to the REPDSTR module of the biomolecular simulation program CHARMM. As an illustrative example, the absolute binding free energy of p-xylene to the nonpolar cavity of the L99A mutant of the T4 lysozyme was calculated. The tests demonstrate that the dual {lambda}-REMD and H-REMD simulation scheme greatly accelerates the configurational sampling of the rotameric states of the side chains around the binding pocket, thereby improving the convergence of the FEP computations.

59 BASIC BIOLOGICAL SCIENCES↗

Computation of absolute hydration and binding free energy with free energy perturbation distributed replica-exchange molecular dynamics.

Distributed Replica (REPDSTR) is a powerful parallelization technique enabling simulations of a group of replicas in a parallel/parallel fashion, where each replica is distributed to different nodes of a large cluster [Theor. Chem. Acc. 2003, 109, 140]. Here, we use the framework provided by REPDSTR to combine a staged free energy perturbation protocol with replica-exchange molecular dynamics (FEP/REMD). The structure of REPDSTR, which allows multiple parallel input/output (I/O), facilitates the treatment of replica-exchange to couple the N window simulations corresponding to different values of the thermodynamic coupling parameters. As a result, each of the N synchronous window simulations benefit from the sampling carried out by the N-1 others. As illustrative examples of the FEP/REMD strategy, calculations of the absolute hydration and binding free energy of small molecules were performed using the biomolecular simulation program CHARMM adapted for the IBM Blue Gene/P platform. The computations show that a FEP/REMD strategy significantly improves the sampling and accelerates the convergence of absolute free energy computations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photodissociation of acetaldehyde and the absolute photoionization cross section of HCO.

Photodissociation of acetaldehyde (CH{sub 3}CHO) at 266 nm produced CH{sub 3} and HCO radicals, and single-photon vacuum ultraviolet ionization was used to record velocity map ion images of both CH{sub 3}{sup +} and HCO{sup +}. Comparison of the translational energy distributions from both species indicates that secondary fragmentation of HCO is negligible for 266 nm photodissociation. Thus, the relative photoion signals for CH{sub 3}{sup +} and HCO{sup +} in the mass spectrometer, combined with the recently measured absolute photoionization cross section of CH{sub 3}, allowed the determination of the absolute photoionization cross section of HCO ({sigma}(HCO) = 4.8 {+-} {sub 1.5}{sup 2.0}, 5.9 {+-} {sub 1.6}{sup 2.2}, and 3.7 {+-} {sub 1.2}{sup 1.6} Mb at 10.257, 10.304, and 10.379 eV, respectively). The observed values are quite small but consistent with the similarly small value at threshold for the isoelectronic species NO. This behavior is discussed in terms of the character of the HOMO in both molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Absolute Coverages for Small Aliphatic Alcohols on TiO2(110)

The absolute coverages of water and small aliphatic alcohols (C1-C4) were determined on TiO{sub 2}(110) using a combination of temperature programmed desorption and liquid nitrogen cooled quartz crystal microbalance measurements. The absolute saturation coverages of water on Ti{sup 4+} and bridging oxygen (O{sub b}) sites are found to be equal to 1 monolayer with respect to the number of Ti{sup 4+} and/or O{sub b} sites (1 ML {triple_bond} 5.2 x 10{sup 14} cm{sup 2}) in a good agreement with prior studies. The saturation coverages of primary alcohols on Ti{sup 4+} sites are found to be approximately constant and equal to 0.77 ML. This indicates that the increasing length of the alkyl chains does not contribute to additional steric hindrance. Additional steric hindrance is observed with increasing number of chains as shown for secondary alcohols and tertiary t-butanol where the coverage decreases to 0.62 and 0.44 ML, respectively. On O{sub b} rows, a monotonic decrease of the alcohol coverage is observed for both increasing length of the alkyl chains and the chain number.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BeyondPlanck: VII. Bayesian estimation of gain and absolute calibration for cosmic microwave background experiments

We present a Bayesian calibration algorithm for cosmic microwave background (CMB) observations as implemented within the global end-to-end BEYONDPLANCK framework and applied to the Planck Low Frequency Instrument (LFI) data. Following the most recent Planck analysis, we decomposed the full time-dependent gain into a sum of three nearly orthogonal components: one absolute calibration term, common to all detectors, one time-independent term that can vary between detectors, and one time-dependent component that was allowed to vary between one-hour pointing periods. Each term was then sampled conditionally on all other parameters in the global signal model through Gibbs sampling. The absolute calibration is sampled using only the orbital dipole as a reference source, while the two relative gain components were sampled using the full sky signal, including the orbital and Solar CMB dipoles, CMB fluctuations, and foreground contributions. We discuss various aspects of the data that influence gain estimation, including the dipole-polarization quadrupole degeneracy and processing masks. Comparing our solution to previous pipelines, we find good agreement in general, with relative deviations of -0.67% (-0.84%) for 30 GHz, 0.12% (-0.04%) for 44 GHz and -0.03% (-0.64%) for 70 GHz, compared to Planck PR4 and Planck 2018, respectively. We note that the BEYONDPLANCK calibration was performed globally, which results in better inter-frequency consistency than previous estimates. Additionally, WMAP observations were used actively in the BEYONDPLANCK analysis, which both breaks internal degeneracies in the Planck data set and results in an overall better agreement with WMAP. Finally, we used a Wiener filtering approach to smoothing the gain estimates. We show that this method avoids artifacts in the correlated noise maps as a result of oversmoothing the gain solution, which is difficult to avoid with methods like boxcar smoothing, as Wiener filtering by construction maintains a balance between data fidelity and prior knowledge. Although our presentation and algorithm are currently oriented toward LFI processing, the general procedure is fully generalizable to other experiments, as long as the Solar dipole signal is available to be used for calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute calibration of image plates for electrons at energy between 100 keV and 4 MeV

We measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV and 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on solid density targets. This paper presents the calibration results of image plate photon stimulated luminescence per electron at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energy depositions at these angles. These provide a complete set of tools that allows extraction of our absolute calibration to other spectrometer setting at this electron energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗