Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

Selecting 1D projections for 2D tomography reconstruction

Previous works on reconstructing the 4D phase space using tomography require optimal selection of projection views to achieve accurate reconstruction. In 2D reconstruction, the process is straightforward, as an object can be evenly sampled by dividing the angles evenly. However, extending this concept from 2D to 4D is not intuitive. This work demonstrates that quaternions can be used to more effectively describe views in 4D and introduces the Fibonacci Flower algorithm and repulsive force algorithm to evenly space views in 4D space in order to achieve higher reconstruction accuracy.

Accelerator Physics↗

Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Direct spectral measurements of midinfrared radiation from a laser wakefield accelerator

The formation of plasma waves during laser wakefield acceleration (LWFA) produces time-dependent frequency shifts in the driving laser pulse, extending its spectral content to the infrared. We present direct spectral measurements of multi-mJ infrared pulses from an LWFA. Experimental beam profile measurements and three-dimensional particle-in-cell simulations suggest high focusability of these pulses. Further, particle-in-cell simulations demonstrate that the measurement of side-scattered infrared radiation may serve as a diagnostic of plasma waves and the efficiency of spectral broadening during LWFA.

43 PARTICLE ACCELERATORS↗

Modeling betatron radiation using particle-in-cell codes for plasma wakefield accelerator diagnostics

The analysis of plasma wakefield acceleration experimental measurements, particularly in the characterization of photons emitted through the betatron radiation mechanism, requires the development of accurate numerical models. These computational models are crucial for supporting modern instrumentation designed to measure the single-shot, double-differential angular-energy radiation spectra resulting from interactions between beams and plasmas. Motivated by the needs of such applications, this paper presents detailed numerical models of betatron radiation generated in beam-plasma acceleration experiments. These models are based on the integration of the Liénard-Wiechert (LW) potentials, applied to computed particle trajectories. The particle trajectories are generated using three distinct methods: first, by tracking particles through idealized fields in the blowout regime of PWFA; second, by obtaining trajectories using the fast quasistatic particle-in-cell (PIC) code quickpic; and third, obtaining trajectories from the fully self-consistent PIC code osiris. To ensure the accuracy and reliability of these models, the paper includes various benchmark tests using analytical expressions, as well as employing the PIC code epoch, which takes an alternative approach by using a Monte Carlo quantum electrodynamics (QED)-based radiation model. Additionally, the paper presents simulations of the expected experimental betatron radiation spectra, taking into account parameters relevant to PWFA and plasma photocathode experiments at the SLAC FACET-II facility.

Yadav, M. [University of California, Los Angeles, ↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

Reflections

Flash radiography is a much used diagnostic technique for high-explosively driven hydrodynamic experiments. Two linear-induction electron accelerators (LIAs) at the Los Alamos Dual Axis Radiography of Hydrodynamic Tests (DARHT) facility provide the source spots for point projection radiography of exceptionally large and dense experiments. In these LIAs, the beam acceleration is provided by high-voltage pulses applied to a number of inductively isolated gaps. The high-voltage pulses are produced by remotely located pulsedpower generators and delivered to the gaps by long highvoltage cables. For Scorpius, these pulse generators are called line replacement units (LRUs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Successful Cleanroom Installation of PIP-II SSR2 Coupler Using Robotic Arm

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam s transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

Narug, C.↗

Machine protection system for coherent electron cooling experiment

The coherent electron cooling (CeC) experiment employs a 15 MeV electron beam with up to a few milliamperes current which is capable of destroying the vacuum equipment or intercepting beam diagnostics. The high-current beam can be delivered to two different dumps. RF systems include normal conducting and superconducting cavities which also require protection from abnormal conditions. In this paper, we describe in detail the design and operation of the machine protection system for the CeC accelerator.

43 PARTICLE ACCELERATORS↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2024

NSLS-II accelerator physicists advanced the operational performance and scientific capabilities of NSLS-II, providing regular lattice characterization and correction, injec tion optimization, vertical emittance control, and beam dynamics reports with corre lation analysis. We further developed advanced lattice characterization techniques and studies on impedance, beam-induced heating, and higher-harmonic RF cavity effects to support NSLS-II and its high-brightness upgrade. The assessment of free-electron laser options for the NSLS-II upgrade has been completed. We carried out comprehensive studies focused on complex bend magnets and novel efficient injection schemes for next-generation low-emittance synchrotrons. We contributed to the Electron-Ion Collider project, including Electron Storage Ring lattice design, beam diagnostics, and injector studies. The physicists participated in international collaborations, including the development of Python-based Middle Layer software, and participated in key accel erator physics workshops and scientific meetings. The main research accomplishments achieved in 2024 are summarized in this report.

43 PARTICLE ACCELERATORS↗

The MTA primary beamline description and performance [Slides]

The Muon Test Area (2003) was initially constructed to develop, test, and verify muon ionization apparatus using the 400-MeV proton beam from the Fermilab Linac. Since muon facilities involve the capture, collection and cooling of ~10 13 muons at a repetition conclusive tests require ~10 13 protons/pulse (full Linac beam): the original concept/request was for a full Linac capability (~10 14 p/sec). The beamline designed for MTA experiments, however, includes specialized insertions for linac beam diagnostics and beam measurements, greatly enhancing the functionality and complexity of the beamline. Installation of the beamline was complete fall, 2008. It represents the only facility in which experiments have direct access to a primary beam.

43 PARTICLE ACCELERATORS↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Laboratory tests of laser control of electron beams for future colliders

Laser-driven Compton backscattering (CBS) has been proposed as method for controlling the intensity of colliding bunches in the FCC-ee so as to avoid the flip-flop instability caused by intensity asymmetry in colliding bunches. Laser-based collimation has also been proposed as an indestructible collimator for high-intensity electron beams. We have initiated a laboratory-based test program of these concepts with the E344 experiment at FACET-II. In this paper, we describe simulations of laser–beam interactions at FACET-II and the relevant scaling for FCC-ee. We also describe the experimental setup and diagnostics that will be used to make the measurements at FACET-II.

accelerator physics↗

NuMI Beam Muon Monitor Data Analysis and Simulation for Improved Beam Monitoring

The NuMI muon monitors (MMs) are a very important diagnostic tool for monitoring the stability of the neutrino beam used by the NOvA experiment at Fermilab. The goal of our study is to maintain the quality of the MM signal and to establish the correlations between the neutrino and muon beam profile. This study could also inform the LBNF decision on the beam diagnostic tools. We report on the progress of beam scan data analysis (beam position, spot size, and magnetic horn current scan) and comparison with the simulation outcomes.

43 PARTICLE ACCELERATORS↗

Experimental capabilities of the LMJ-PETAL facility

In this study, recent progress in the experimental capabilities of the LMJ-PETAL laser facility is reviewed. Updates on the indirect-drive D 2 implosion experiments and equation-of-state experiments using the LMJ laser are presented, including the commissioning of new plasma diagnostics. Several recent campaigns using the PETAL laser alone are also presented, namely the development of a platform using high-resolution and high-energy X-ray sources for radiography experiments, laser wakefield acceleration studies in the self-modulated regime, and neutron generation using a Target Normal Sheath Accelerated proton beam in a pitcher-catcher configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Post-DTL Beam Delivery

Ensuring that the beam delivered from the upgraded Front-End (FE) meets the Key Performance Parameters (KPPs) at each user facility is critical to the success of the LANSCE Accelerator Modernization Project (LAMP). For a high-intensity, multi-user facility like LANSCE, compliance with beam loss and radiation thresholds is as important as the charge delivered to each target. While early LAMPF/LANSCE operations relied on iterative tuning to minimize losses from beam halo and tail particles, the new FE may introduce different beam distributions and loss modes—making predictive modeling essential. To manage this, the F2E (Front-End to End) effort is developing detailed particle-tracking models that reflect realistic beamline conditions, including halo formation and expected diagnostic readings. These "snapshot" simulations aim to benchmark live machine performance at a given moment. This will help quantify how beam quality from the new FE will propagate downstream through the facility. Only by validating these models can we confidently assess and mitigate the potential impacts of the LAMP FE on beam delivery. Post-DTL, the beam splits to serve five major user facilities. Historically, low-energy beam transport has been modeled using TRACE, and higher-energy sections with TRANSPORT. These have now been unified into MAD-X format and validated with codes such as Elegant, pyOrbit, XSuite, Impact-Z, and HPSim. The primary focus now is on accurate modeling of full particle distributions (including beam halo) as they traverse the accelerator and beamlines to each experimental station. All models are at various stages of validation with empirical data.

43 PARTICLE ACCELERATORS↗

Laser Wakefield Accelerator modelling with Variational Neural Networks

A machine learning model was created to predict the electron spectrum generated by a GeV-class laser wakefield accelerator. The model was constructed from variational convolutional neural networks, which mapped the results of secondary laser and plasma diagnostics to the generated electron spectrum. An ensemble of trained networks was used to predict the electron spectrum and to provide an estimation of the uncertainty of that prediction. It is anticipated that this approach will be useful for inferring the electron spectrum prior to undergoing any process that can alter or destroy the beam. In addition, the model provides insight into the scaling of electron beam properties due to stochastic fluctuations in the laser energy and plasma electron density.

43 PARTICLE ACCELERATORS↗