Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Characterizing nanoscale precipitation in a titanium alloy by laser-assisted atom probe tomography

Highlights: • Atom-probe tomography was performed on Ti-5Al-5Mo-5V-3Cr wt% after quenching and 300 °C aging. • Isothermal ω phase was identified as Ti-rich and solute depleted after 1 h of aging. • The ω precipitate/matrix interface is O enriched. This may facilitate α formation. • High laser-pulse energies increase the probability of complex ion formation, complicating analysis. • Discrepancies between data from the LEAP 5000 XS and LEAP 4000X Si are discussed. - Abstract: Atom-probe tomography was performed on the metastable β-Ti alloy, Ti-5Al-5Mo-5V-3Cr wt% (Ti-5553), aged at 300 °C for 0 to 8 h, to precipitate the embrittling isothermal ω phase. Accurate precipitate quantification requires monitoring and controlling suitable charge-state ratios in the mass spectrum, which in turn are closely related to the laser pulse energy used. High ultraviolet laser pulse energies result in significant complex molecular ion formation during field-evaporation, causing mass spectral peak overlaps that inherently complicate data analyses. Observations and accurate quantification of the ω-phase under such conditions are difficult. The effect is minimized or eliminated by using smaller laser pulse energies. With a small laser pulse energy, Ti-rich and solute depleted precipitates of the isothermal ω phase with an oxygen enriched interface are observed as early as after 1 h aging time utilizing the LEAP 5000X S (77% detection efficiency). We note that these precipitates were not detected below a 2 h aging time with the LEAP 4000X Si (58% detection efficiency). The results are compared to the archival literature. The Al concentration in the matrix/precipitate interfacial region increases during aging. Nucleation of the α-phase at longer aging times may be facilitated by the O and Al enrichment at the matrix/precipitate interface (both strong α-stabilisers). The kinetics and compositional trajectory of the ω-phase with aging time are quantified, facilitating direct correlation of the APT data to previously published mechanical testing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal pulse sequence modifications and no additional scan time, improving ASL’s clinical applicability.

60 APPLIED LIFE SCIENCES↗

Enabling phase quantification of anhydrous cements via Raman imaging

The phase composition of Portland cements is typically determined using conventional techniques like X-ray Diffraction (XRD) Rietveld analysis, optical microscopy point counting, and electron microscopy. However, these techniques have several limitations that may affect their accuracy in certain sample-specific scenarios. Here, we report a highly accurate phase quantification of 11 different types of commercial, anhydrous cements using a new and complementary technique: Raman imaging. Specifically, for the 4 principal phases, composition from our extensive data (250,000 Raman spectra per sample, error < 0.71%) and those obtained from XRD Rietveld and supplier data have high coefficients of determination (R{sup 2} > 0.98, mean deviation <2%). Additionally, we also quantify 8 secondary phases present in cement clinkers (gypsum, anhydrite, bassanite, syngenite, dolomite, calcite, quartz, and portlandite) with a high degree of confidence, thereby demonstrating that Raman imaging is a highly versatile tool for anhydrous phase quantification in a broad variety of cements.

36 MATERIALS SCIENCE↗

Long-read sequencing transcriptome quantification with lr-kallisto

RNA abundance quantification has become routine and affordable thanks to high-throughput “short-read” technologies that provide accurate molecule counts at the gene level. Similarly accurate and affordable quantification of definitive full-length, transcript isoforms has remained a stubborn challenge, despite its obvious biological significance across a wide range of problems. “Long-read” sequencing platforms now produce data-types that can, in principle, drive routine definitive isoform quantification. However some particulars of contemporary long-read datatypes, together with isoform complexity and genetic variation, present bioinformatic challenges. We show here, using ONT data, that fast and accurate quantification of long-read data is possible and that it is improved by exome capture. To perform quantifications we developed lr-kallisto, which adapts the kallisto bulk and single-cell RNA-seq quantification methods for long-read technologies.

Loving, Rebekah K. (ORCID:0000000187250376)↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

Knowledge-guided machine learning can improve carbon cycle quantification in agroecosystems

Abstract Accurate and cost-effective quantification of the carbon cycle for agroecosystems at decision-relevant scales is critical to mitigating climate change and ensuring sustainable food production. However, conventional process-based or data-driven modeling approaches alone have large prediction uncertainties due to the complex biogeochemical processes to model and the lack of observations to constrain many key state and flux variables. Here we propose a Knowledge-Guided Machine Learning (KGML) framework that addresses the above challenges by integrating knowledge embedded in a process-based model, high-resolution remote sensing observations, and machine learning (ML) techniques. Using the U.S. Corn Belt as a testbed, we demonstrate that KGML can outperform conventional process-based and black-box ML models in quantifying carbon cycle dynamics. Our high-resolution approach quantitatively reveals 86% more spatial detail of soil organic carbon changes than conventional coarse-resolution approaches. Moreover, we outline a protocol for improving KGML via various paths, which can be generalized to develop hybrid models to better predict complex earth system dynamics.

54 ENVIRONMENTAL SCIENCES↗

Bayesian Optimized Deep Ensemble for Uncertainty Quantification of Deep Neural Networks: a System Safety Case Study on Sodium Fast Reactor Thermal Stratification Modeling

Deep neural networks (DNNs) are increasingly important to scientific computing and engineering system simulations. Accurate uncertainty quantification (UQ) for DNNs is critical in safety-sensitive engineering domains. Traditional Deep Ensemble (DE) methods, while easy to implement, frequently suffer from poorly calibrated uncertainty estimates and limited predictive accuracy due to reliance on fixed architectures with varied weight initializations. To address these issues, we introduce a workflow that combines Bayesian Optimization (BO) and DE. The workflow is modular, scalable, and integrates parallel BO initialized with Sobol sequences to individually optimize the hyperparameters of each ensemble member. This method enhances ensemble diversity, improves predictive accuracy, and provides reliable uncertainty estimates. We evaluate the proposed BODE approach in a sodium fast reactor thermal stratification modeling case study, where we used a densely connected convolutional neural network to predict turbulent viscosity during the reactor transient with consideration of data noise. We benchmark its performance against several optimization approaches, including baseline deep ensemble, evolutionary algorithm-optimized ensemble, ensemble formed via random search combined with greedy selection, and a BO ensemble using random initialization. Here, our results demonstrate superior performance of the developed BODE approach. In noise-free scenarios, BODE notably reduces incorrect aleatoric uncertainty and significantly enhances predictive accuracy. Under conditions of 5% and 10% Gaussian noise, BODE adaptively quantifies uncertainty proportional to data noise, achieving up to an 80% reduction in root mean square error compared to baseline methods and producing well-calibrated prediction intervals.

Bayesian optimization↗

Implement Method for Automated Testing of Markov Chain Convergence into INVERSE for ORNL12-RS-108J: Advanced Multi-Dimensional Forward and Inverse Modeling

The DiffeRential Evolution Adaptive Metropolis (DREAM) method is a powerful optimization/uncertainty quantification tool used to solve inverse transport problems in Los Alamos National Laboratory’s INVERSE code system. The DREAM method has been shown to be adept at accurate uncertainty quantification, but it can be very computationally demanding. Previously, the DREAM method in INVERSE performed a user-defined number of particle transport calculations. This placed a burden on the user to guess the number of calculations that would be required to accurately solve any given problem. This report discusses a new approach that has been implemented into INVERSE, the Gelman-Rubin convergence metric. This metric automatically detects when an appropriate number of transport calculations have been completed and the uncertainty in the inverse problem has been accurately calculated. In a test problem with a spherical geometry, this method was found to decrease the number of transport calculations (and thus time required) to solve a problem by an average of over 90%. In a cylindrical test geometry, a 75% decrease was obtained.

97 MATHEMATICS AND COMPUTING↗

SU-D-18C-05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping

Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion.

60 APPLIED LIFE SCIENCES↗

Uncertainty and Sensitivity Analysis of Afterbody Radiative Heating Predictions for Earth Entry

The objective of this work was to perform sensitivity analysis and uncertainty quantification for afterbody radiative heating predictions of Stardust capsule during Earth entry at peak afterbody radiation conditions. The radiation environment in the afterbody region poses significant challenges for accurate uncertainty quantification and sensitivity analysis due to the complexity of the flow physics, computational cost, and large number of un-certain variables. In this study, first a sparse collocation non-intrusive polynomial chaos approach along with global non-linear sensitivity analysis was used to identify the most significant uncertain variables and reduce the dimensions of the stochastic problem. Then, a total order stochastic expansion was constructed over only the important parameters for an efficient and accurate estimate of the uncertainty in radiation. Based on previous work, 388 uncertain parameters were considered in the radiation model, which came from the thermodynamics, flow field chemistry, and radiation modeling. The sensitivity analysis showed that only four of these variables contributed significantly to afterbody radiation uncertainty, accounting for almost 95% of the uncertainty. These included the electronic- impact excitation rate for N between level 2 and level 5 and rates of three chemical reactions in uencing N, N(+), O, and O(+) number densities in the flow field.

West, Thomas K., IV↗

TMTPro Complementary Ion Quantification Increase Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 level

The ability of the TMTPro isobaric labeling reagents to form complementary ions for accurate multiplexed proteomics at the MS2 level was investigated. Human and yeast peptides were labeled in distinct ratios to analyze the effect of interference on the quantification accuracy. A method, TMTProC, was developed and optimized for accurate, sensitive MS2-level quantification of up to 8 conditions in one MS-run.

Stadlmeier, Michael↗

SU-E-J-215: Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry

Purpose: To identify and analyze the appearance of calcifications and brachytherapy seeds on magnitude and phase MRI images and to investigate whether they can be distinguished from each other on corrected phase images for application to prostate and breast low dose rate (LDR) implant dosimetry. Methods: An agar-based gel phantom containing two LDR brachytherapy seeds (Advantage Pd-103, IsoAid, 0.8mm diameter, 4.5mm length) and two spherical calcifications (large: 7mm diameter and small: 4mm diameter) was constructed and imaged on a 3T Philips MR scanner using a 16-channel head coil and a susceptibility weighted imaging (SWI) sequence (2mm slices, 320mm FOV, TR/ TE= 26.5/5.3ms, 15 degree flip angle). The phase images were unwrapped and corrected using a 32×32, 2D Hanning high pass filter to remove background phase noise. Appearance of the seeds and calcifications was assessed visually and quantitatively using Osirix (http://www.osirix-viewer.com/). Results: As expected, calcifications and brachytherapy seeds appeared dark (hypointense) relative to the surrounding gel on the magnitude MRI images. The diameter of each seed without the surrounding artifact was measured to be 0.1 cm on the magnitude image, while diameters of 0.79 and 0.37 cm were measured for the larger and smaller calcifications, respectively. On the corrected phase images, the brachytherapy seeds and the calcifications appeared bright (hyperintense). The diameter of the seeds was larger on the phase images (0.17 cm) likely due to the dipole effect. Conclusion: MRI has the best soft tissue contrast for accurate organ delineation leading to most accurate implant dosimetry. This work demonstrated that phase images can potentially be useful in identifying brachytherapy seeds and calcifications in the prostate and breast due to their bright appearance, which helps in their visualization and quantification for accurate dosimetry using MR-only. Future work includes optimizing phase filters to best identify and delineate seeds and calcifications.

60 APPLIED LIFE SCIENCES↗

The Sensitivity of Variational Bayesian Neural Network Performance to Hyperparameters

In scientific applications, predictive modeling is often of limited use without accurate uncertainty quantification (UQ) to indicate when a model may be extrapolating or when more data needs to be collected. Bayesian Neural Networks (BNNs) produce predictive uncertainty by propagating uncertainty in neural network (NN) weights and offer the promise of obtaining not only an accurate predictive model but also accurate UQ. However, in practice, obtaining accurate UQ with BNNs is difficult due in part to the approximations used for model training (such as those made in variational inference) and in part to the need to choose a suitable set of hyperparameters; these hyperparameters outnumber those needed for traditional NNs and often have opaque effects on the results. We aim to shed light on the effects of hyperparameter choices for variational BNNs by performing a global sensitivity analysis of variational BNN performance under varying hyperparameter settings. Our results indicate that many of the hyperparameters interact with each other to affect both predictive accuracy and UQ. For improved usage of variational BNNs in real-world applications, we suggest that thorough hyperparameter tuning, including tuning of prior hyperparameters and loss function parameters, is essential for accurate UQ in variational BNNs.

97 MATHEMATICS AND COMPUTING↗

A general framework for quantifying uncertainty at scale

Abstract In many fields of science, comprehensive and realistic computational models are available nowadays. Often, the respective numerical calculations call for the use of powerful supercomputers, and therefore only a limited number of cases can be investigated explicitly. This prevents straightforward approaches to important tasks like uncertainty quantification and sensitivity analysis. This challenge can be overcome via our recently developed sensitivity-driven dimension-adaptive sparse grid interpolation strategy. The method exploits, via adaptivity, the structure of the underlying model (such as lower intrinsic dimensionality and anisotropic coupling of the uncertain inputs) to enable efficient and accurate uncertainty quantification and sensitivity analysis at scale. Here, we demonstrate the efficiency of this adaptive approach in the context of fusion research, in a realistic, computationally expensive scenario of turbulent transport in a magnetic confinement tokamak device with eight uncertain parameters, reducing the effort by at least two orders of magnitude. In addition, we show that this refinement method intrinsically provides an accurate surrogate model that is nine orders of magnitude cheaper than the high-fidelity model.

Farcaş, Ionuţ-Gabriel (ORCID:0000000238841580)↗

WE-G-BRD-06: Variation in Dynamic Positron Emission Tomography Imaging of Tumor Hypoxia in Early Stage Non-Small Cell Lung Cancer Patients Undergoing Stereotactic Body Radiotherapy

Purpose: Tumor hypoxia is correlated with treatment failure. To date, there are no published studies investigating hypoxia in non-small cell lung cancer (NSCLC) patients undergoing SBRT. We aim to use 18F-fluoromisonidazole (18F-FMISO) positron emission tomography (PET) imaging to non-invasively quantify the tumor hypoxic volume (HV), to elucidate potential roles of reoxygenation and tumor vascular response at high doses, and to identify an optimal prognostic imaging time-point. Methods: SBRT-eligible patients with NSCLC tumors >1cm were prospectively enrolled in an IRB-approved study. Computed Tomography and dynamic PET images (0–120min, 150–180min, and 210–240min post-injection) were acquired using a Siemens BiographmCT PET/CT scanner. 18F-FMISO PET was performed on a single patient at 3 different time points around a single SBRT delivery of 18 Gy and HVs were compared using a tumor-to-blood ratio (TBR)>1.2 and rate of influx (Ki)>0.0015 (Patlak). Results: Results from our first patient showed substantial temporal changes in HV following SBRT. Using a TBR threshold >1.2 and summed images 210–240min, the HVs were 19%, 31% and 13% of total tumor volume on day 0, 2 (48 hours post-SBRT), and 4 (96 hours post-SBRT). The absolute volume of hypoxia increased by nearly a factor of 2 after 18 Gy and then decreased almost to baseline 96 hours later. Selected imaging timepoints resulted in temporal changes in HV quantification obtained with TBR. Ki, calculated using 4-hour dynamic data, evaluated HVs as 22%, 75% and 21%, respectively. Conclusions: ith the results of only one patient, this novel pilot study highlights the potential benefit of 18F-FMISO PET imaging as results indicate substantial temporal changes in tumor HV post-SBRT. Analysis suggests that TBR is not a robust parameter for accurate HV quantification and heavily influenced by imaging timepoint selection. Kinetic modeling parameters are more sensitive and may aid in future treatment individualization based on patient-specific biological information.

60 APPLIED LIFE SCIENCES↗

Bayesian projection pursuit regression

In projection pursuit regression (PPR), a univariate response variable is approximated by the sum of $M$ “ridge functions,” which are flexible functions of one-dimensional projections of a multivariate input variable. Traditionally, optimization routines are used to choose the projection directions and ridge functions via a sequential algorithm, and $M$ is typically chosen via cross-validation. Here, we introduce a novel Bayesian version of PPR, which has the benefit of accurate uncertainty quantification. To infer appropriate projection directions and ridge functions, we apply novel adaptations of methods used for the single ridge function case ($M$=1), called the Bayesian Single Index Model; and use a Reversible Jump Markov chain Monte Carlo algorithm to infer the number of ridge functions $M$. We evaluate the predictive ability of our model in 20 simulated scenarios and for 23 real datasets, in a bake-off against an array of state-of-the-art regression methods. Finally, we generalize this methodology and demonstrate the ability to accurately model multivariate response variables. Its effective performance indicates that Bayesian Projection Pursuit Regression is a valuable addition to the existing regression toolbox.

97 MATHEMATICS AND COMPUTING↗

Limitations of traditional tools for beyond design basis external hazard PRA

Probabilistic risk assessment (PRA) is being used increasingly by the nuclear industry for safety during normal operations as well as for the protection against external hazards. Computation of total risk in an external hazard PRA is dependent on hazard assessment, fragility assessment, and systems analysis. A systems analysis for propagation of component fragilities is conducted using event and fault trees. The event and fault trees for an actual power plant can be fairly large in size, which imposes computational challenges. Hence, certain assumptions are employed for computational efficiency. These assumptions typically represent the conditions imposed during the design basis (DB) scenario. The traditional PRA tools based on these assumptions are also widely applied to perform risk assessment in the context of beyond design basis (BDB) scenarios. However, some of these assumptions may not be valid for certain BDB scenarios. In addition, the probability of dependent failures also increases in BDB scenarios due to common cause failures (CCF) which usually results from design modifications, human errors, etc. In this manuscript, a simple and a relatively more complex illustrative examples are used to show the limitation of these assumptions in the numerical quantification of risk for the case of BDB conditions. Case studies with CCF events across multiple fault trees are also presented to illustrate the effect of these assumptions when traditional approach is used in BDB risk assessment. It is shown that the assumptions are valid for the case of DB conditions but may lead to excessively conservative risk estimates in the case of BDB conditions. Finally, a Bayesian network based top-down algorithm is proposed as an alternative tool for accurate numerical quantification of total risk in systems analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗