Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Cardiopulmonary data acquisition system. Version 2.0, volume 1: User's guide

The Cardiopulmonary Data Acquisition System is a computerized method of both collecting and analyzing physiological data on subjects during a treadmill or ergometer stress test in the clinic. The real time acquisition of the physiological data, such as, heart rate, blood pressure, work load, and respiratory gases is accomplished by an LSI-11 microcomputer which displays this data on a hard copy terminal. The data are also concurrently stored on a mass storage device and anytime after the test period a selectable number of copies of the plots or minute reports can be reproduced at the terminal.

Source record↗

Mars sample return: Site selection and sample acquisition study

Various vehicle and mission options were investigated for the continued exploration of Mars; the cost of a minimum sample return mission was estimated; options and concepts were synthesized into program possibilities; and recommendations for the next Mars mission were made to the Planetary Program office. Specific sites and all relevant spacecraft and ground-based data were studied in order to determine: (1) the adequacy of presently available data for identifying landing sities for a sample return mission that would assure the acquisition of material from the most important geologic provinces of Mars; (2) the degree of surface mobility required to assure sample acquisition for these sites; (3) techniques to be used in the selection and drilling of rock a samples; and (4) the degree of mobility required at the two Viking sites to acquire these samples.

Nickle, N.↗

Development of a simple, self-contained flight test data acquisition system

A low cost flight test data acquisition system, applicable to general aviation airplanes, was developed which meets criteria for doing longitudinal and lateral stability analysis. Th package consists of (1) a microprocessor controller and data acquisition module; (2) a transducer module; and (3) a power supply module. The system is easy to install and occupies space in the cabin or baggage compartment of the airplane. All transducers are contained in these modules except the total pressure tube, static pressure air temperature transducer, and control position transducers. The NASA-developed MMLE program was placed on a microcomputer on which all data reduction is done. The flight testing program undertaken proved both the flight testing hardware and the data reduction method to be applicable to the current field of general aviation airplanes.

Renz, R. R. L.↗

Discriminator aided phase lock acquisition for suppressed carrier signals

A discriminator aided technique for acquisition of phase lock to a suppressed carrier signal utilizes a Costas loop which is initially operated open loop and control voltage for its VCXO is derived from a phase detector that compares the VCXO to a reference frequency thus establishing coarse frequency resolution with the received signal. Then the Costas loop is closed with the low-pass filter of the channel having a bandwidth much greater (by a factor of about 10) than in the I channel so that a frequency discriminator effect results to aid carrier resolution. Finally, after carrier acquisition, the Q-channel filter of the Costas loop is switched to a bandwidth substantially equal to that of the I-channel for carrier tracking.

Carson, L. M.↗

NASA tracking and data acquisition in the 1990s - High earth orbit and planetary spacecraft support

It is pointed out that during the decade of the 1980's the Deep Space Network (DSN) and the ground stations of the Ground Spaceflight Tracking Data Network (GSTDN) will have been consolidated into one ground-based network to provide services for tracking and data acquisition for NASA deep space probes and highly elliptical earth orbiters. The Tracking and Data Relay Satellite System (TDRSS) will have been implemented to handle low earth orbiters. Anticipated solar system exploration missions of the 1990's are discussed, and a description is presented of the new tracking and data acquisition requirements for supporting these missions. The technology options needed to meet these new requirements are identified, and the impact of these technology options on the consolidated DSN is discussed. Attention is given to the evolution of the DSN of the 1980's into the DSN of the year 2000.

Smith, J. G.↗

NASA tracking and data acquisition in the 1990's - Support for low earth orbit missions

Requirements related to increases in data volume for missions projected for the 1990's could be met by increasing the number of satellites in the Tracking and Data Relay Satellite System (TDRSS) constellation or by providing a new tracking and data acquisition satellite system having greater capacity (gigabits), increased reliability, and more direct user-to-relay connectivity. The program to develop the heir to TDRSS for the 1990's, has been defined as Tracking and Data Acquisition System (TDAS). A description is presented of the system architectural considerations which have to be studied in order to develop a cost effective TDAS. Attention is given to basic TDAS design parameters, TDAS spacecraft architectures, system considerations, technology considerations, and TDAS constellation options involving 2, 3, and 4 satellites.

Schwartz, J. J.↗

Development of a simple, self-contained flight test data acquisition system

The system concepts and the flight test program results for a NASA designed in-flight data acquisition system are described. The system draws power from a rechargeable battery pack and intrudes on the aircraft systems only with a total pressure probe, a static pressure probe, and control position transducers, which are simply taped to the frame. A 4000 byte microcomputer forms the heart of the data recording system for cassette tape storage, and is expansion coupled to an eight-bit interactive microcomputer which interfaces with a transducer package for 16-channel demultiplexing. The transducers, ranges, and accuracies are listed, and a five/sec data acquisition rate minimum requirement is noted, although a 10/sec rate is used. The system components are detailed, along with the control and data processing procedures, and the results of dynamic flight testing are presented.

Renz, R. R. L.↗

Performance analysis for the expanding search PN acquisition algorithm

An approach is described for approximating the cumulative probability distribution of the acquisition time of the serial pseudonoise (PN) search algorithm. The results are applicable to both variable and fixed dwell time systems. The theory is developed for the case where some a priori information is available on the PN code epoch (reacquisition problem or acquisition of very long codes). Also considered is the special case of a search over the whole code. The accuracy of the approximation is demonstrated by comparisons with published exact results for the fixed dwell time algorithm.

Braun, W. R.↗

Comparison between variable and fixed dwell-time PN acquisition algorithms

Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.

Braun, W. R.↗

Search strategy effects on PN acquisition performance

The present paper focusses on 'random' and 'expanding window' PN acquisition search strategies and analytically develops the PN acquisition time statistics as functions of salient system parameters such as prediction SNR, detection and false alarm probabilities and a priori information on epoch location. The significance of this analysis is its general applicability to arbitrary postdetection processing schemes. Computed performance results account for the above salient parameters, wherein sequential detection is employed in conjunction with random and selected expanding window search strategies.

Weinberg, A.↗

Satellite relayed tracking and data acquisition for the 1990's

The Tracking and Data Relay Satellite System (TDRSS) provides near-continuous tracking for low earth-orbiting spacecraft. Increases in data volume projected for the 90's will affect the configuration for data handling in one of two ways. One way involves an increase in the number of satellites in the TDRSS constellation. In connection with the second way, a new tracking and data acquisition satellite system will be developed. The new system will have greater capacity, increased reliability, and a more direct user-to-relay connectivity. The program for developing the ne satellite system of the 1990;s has been defined as Tracking and Data Acquisition System (TDAS). TDAS requirements are considered along with basic TDAS design parameters, TDAS spacecraft architectures, and TDAS constellation options. System and technology considerations are also discussed, taking into account user interface options, operational functions of the TDAS ground elements, and user communication technology.

Schwartz, J. J.↗

Instrumentation, data acquisition and reduction for a large spaceborne helium dewar

The data acquisition system monitors five types of transducers: (1) platinum and germanium resistance thermometers; (2) superconducting liquid level indicators for both cryogen tanks; (3) pressure transducers for both tanks; (4) strain gauges at critical structural locations; and (5) flowmeters for monitoring cryogen tank boiloff which are linear voltage output transducers. All the transducers produce a voltage proportional to the parameter they measure; this is routed to a single six and one-half digit voltmeter by way of an 80-channel multiplexer. The data acquisition program has six main functions: (1) definition and modification of the channels to be stimulated; (2) sensor stimulation and measurement; (3) raw data storage; (4) raw data conversion; (5) real-time formatting and output of raw or converted data; and (6) editing. The heart of the program is a driver section that represents approximately 20 percent of the code. The driver mode sequences and controls the six main functions.

Brooks, W. F.↗

Study of a Tracking and Data Acquisition System (TDAS) in the 1990's

Progress in concept definition studies, operational assessments, and technology demonstrations for the Tracking and Data Acquisition System (TDAS) is reported. The proposed TDAS will be the follow-on to the Tracking and Data Relay Satellite System and will function as a key element of the NASA End-to-End Data System, providing the tracking and data acquisition interface between user accessible data ports on Earth and the user's spaceborne equipment. Technical activities of the "spacecraft data system architecture' task and the "communication mission model' task are emphasized. The objective of the first task is to provide technology forecasts for sensor data handling, navigation and communication systems, and estimate corresponding costs. The second task is concerned with developing a parametric description of the required communication channels. Other tasks with significant activity include the "frequency plan and radio interference model' and the "Viterbi decoder/simulator study'.

Source record↗

Demodulator and Accumulator for the High-speed Data Acquisition System

In support of nonflight project data acquisition, a high speed data acquisition system was designed. The demodulator and accumulator modules at the heart of this system perform the detection and prefiltering of data which are then further processed by a floating point systems 5210 array processor. Block diagrams of the demodulator and accumulator modules are presented.

Brokl, S. S.↗

Digital data-acquisition system for measuring the free decay of acoustical standing waves in a resonant tube

A low-cost digital system based on an 8-bit Apple II microcomputer has been designed to provide on-line control, data acquisition, and evaluation of sound absorption measurements in gases. The measurements are conducted in a resonant tube, in which an acoustical standing wave is excited, the excitation removed, and the sound absorption evaluated from the free decay envelope. The free decay is initiated from the computer keyboard after the standing wave is established, and the microphone response signal is the source of the analog signal for the A/D converter. The acquisition software is written in ASSEMBLY language and the evaluation software in BASIC. This paper describes the acoustical measurement, hardware, software, and system performance and presents measurements of sound absorption in air as an example.

Meredith, R. W.↗

Controller and interface module for the High-Speed Data Acquisition System correlator/accumulator

One complex channel of the High-Speed Data Acquisition System (a subsystem used in the Goldstone solar system radar), consisting of two correlator modules and one accumulator module, is operated by the controller and interface module interfaces are provided to the VAX UNIBUS for computer control, monitor, and test of the controller and correlator/accumulator. The correlator and accumulator modules controlled by this module are the key digital signal processing elements of the Goldstone High-Speed Data Acquisition System. This fully programmable unit provides for a wide variety of correlation and filtering functions operating on a three megaword/second data flow. Data flow is to the VAX by way of the I/O port of a FPS 5210 array processor.

Brokl, S. S.↗

A digital imaging photometry system for cometary data acquisition

This report describes a digital imaging photometry system developed in the Space Science Laboratory at the Marshall Space Flight center. The photometric system used for cometary data acquisition is based on an intensified secondary electron conduction (ISEC) vidicon coupled to a versatile data acquisition system which allows real-time interactive operation. Field tests on the Orion and Rosette nebulas indicate a limiting magnitude of approximately m sub v = 14 over the 40 arcmin field-of-view. Observations were conducted of Comet Giacobini-Zinner in August 1985. The resulting data are discussed in relation to the capabilities of the digital analysis system. The development program concluded on August 31, 1985.

Clifton, K. S.↗

Acquisition and track algorithms for the Astros star tracker

The Astros star tracker has been designed for an employment with the Space Shuttle. An achievement of the performance levels needed has required critical trade-offs between the hardware design and the control algorithms. This paper provides a description of the development of the acquisition and track algorithms. Attention is given to an Astros system overview, a system firmware description, cluster evaluation, guide star selection, exposure time determination, video data input, update interval timing, exposure time sequencing full frame video A/D conversion, analog threshold for acquisition, minimum threshold determination, and the theoretical basis for the track algorithm.

Shalom, E.↗