Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

Truck Platooning Performance with ADAS and Onboard Camera Data Describing Traffic Interactions

This project was part of the Characterizing Behaviors and Capabilities for Emerging Connected and Automated Vehicle Technologies, Sensors, and Connectivity project. The National Laboratory of the Rockies partnered with Cummins Inc. to collect data from Class 8 tractor trailer combinations in platoon (cooperative adaptive cruise control) operations on public roads in southern Indiana. Data collected include J1939 CAN bus, radar, intervehicle position, and video data. The video data could not be shared in the raw form, so they were processed to extract information on the other vehicles on the road, their relative positions, and intrusion events. This information was then columnized for modeling use and further enhanced by appending road information including road type, speed limit, altitude, and grade. The test route included free-flowing traffic, highway interchanges, and construction zones, as well as low-, medium-, and high-grade sections. Individual test conditions varied by day, with advanced driver-assistance system (ADAS) features engaged or disengaged and different combined vehicle masses tested in addition to uncontrolled variables such as weather and traffic interactions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To damp harmonic resonance, this paper proposes an adaptive narrowband damping control that automatically programs, adds, and adjusts the damping around the oscillation frequency when an oscillation is detected. First, the paper presents a low-pass filter design for MMC control loops that pushes all negative damping of the MMC impedance down to the medium-frequency range (< ~ 1000 Hz). Then, an adaptive damping control that uses online oscillation detection is proposed, which can automatically configure the narrowband damper to provide positive damping to the MMC around the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper dynamically adjusts the damping gain and the width of the damping range based on continuous monitoring of system resonance conditions (e.g., adjust damping gain to zero when the system resonance disappears). Electromagnetic transient simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

CIRCLES: Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing

The energy efficiency of today’s vehicular mobility relies on the un-integrated combination of i) control via static assets (traffic lights, metering, variable speed limits, etc.); and ii) onboard vehicle automation (adaptive cruise control (ACC), ecodriving, etc.). These two families of control were not co-designed and are not engineered to work in coordination. Recent studies have shown i) limitations of controls, and even ii) negative impacts of ACC. This project focused on the technology development, implementation and prototyping, and validation of Mobile Traffic Control (MTC). MTC can be viewed as an extension of classical traffic control (in which static infrastructure actuates traffic flow). In the MTC paradigm, automated vehicles actuate the entire flow via their behavior, offering enhanced possibilities to optimize the energy footprint of traffic, if designed correctly. We set out to demonstrate for the first time that considerably reduced fuel consumption of all vehicles in traffic can be achieved via distributed control of a small proportion of CAVs. Compared to baseline vehicular technologies, our work offers a significant design departure: control algorithms for the CAVs consider the impact one vehicle can have on overall traffic, improving resulting overall fuel consumption. We focus on using a few vehicles (as traffic controllers via CAV technology) to improve the energy efficiency of traffic flow to further optimize energy efficiency. A live-traffic demonstration in November 2022 featured the deployment of 100 specially-equipped CAVs, constituting an approximate local penetration rate upwards of 2%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Fuel Consumption Results from a Heterogeneous Four-Truck Platoon

Platooning has the potential to reduce greenhouse gas missions of heavy-duty vehicles. Prior platooning studies have chiefly focused on the fuel economy characteristics and three-truck platoons, and most have investigated aerodynamically homogeneous platoons with trucks of the same trim. For real world application and accurate return on investment for potential adopters, non-uniform platoons and the impacts of grade and disturbances on a platoon’s fuel economy must also be characterized. This study investigates the fuel economy of a heterogeneous four-truck platoon on a closed test track. Tests were run for one hour at a speed of 45 mph. The trucks used for this study are two 2015 Peterbilt 579’s with a Cummins ISX15 and a Paccar MX-13, and two 2009 Freightliner M915A5’s, one armored and the other unarmored. Many analysis methodologies were leveraged to describe and compare the fuel data, including lap-wise and track-segment analysis. The methodology for dividing the data into laps is described in detail. The influence of other factors beyond the aerodynamics of platooning is discussed. CAN fuel rate analysis showed excellent agreement with previous experimental trends for two and three-truck platoons. In general, the indicated fuel economy benefits in this study were 5-11% for following vehicles and 0-4% for the lead vehicle in platoon relative to their baseline fuel consumption. On a cumulative basis, all platoons saved fuel, ranging from 6% to 8% versus the sum of the standalone trucks’ fuel consumption. The practical implications of the fuel economy results are discussed, as well as avenues for future research. Introduction and Motivation platooning is controlled coordination of two or more vehicles in a convoy, sometimes called CACC (Coordinated or Cooperative Adaptive Cruise Control). The distance between vehicles in a platoon can be controlled tightly at no additional fatigue to the driver. Platooning vehicles can also respond quickly to braking events of the leader, much more quickly than the typical human driver’s reaction time of 1-1.5 s. Therefore, vehicles in a platoon can follow each other much more closely than would usually be considered a safe following distance under human operation. It is implied that under very close following conditions, platooning technology must be extremely robust before it is safe for wide-scale implementation. Platooning is under investigation as a fuel-saving technology. Close-following significantly reduces aerodynamic drag for both leading and trailing vehicles. According to the NRC in 2010, aerodynamic drag represents roughly half of a Class-8 truck’s on-highway fuel usage, meaning a 20% reduction in drag roughly equals a 10% reduction in fuel usage, if all other sources of energy loss remain equal (i.e. accessory, rolling resistance, drivetrain, braking). It is by aerodynamics that platooning saves fuel. At risk of oversimplifying the aerodynamics, following (or trailing) vehicles experience reduced wind velocity due to shielding, and the leading vehicles experience an increased aft pressure, especially at distances closer than 75’ (23 m).

greenhouse gas emissions, truck platoon, heavy-dut↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Adaptable Data Driven Model Predictive Control for Heat Pipe Microreactors

To establish a technical basis for self-regulating microreactors, a model predictive control (MPC) system is investigated to proactively respond to anomalies and disturbances in anticipation of potential deviations from operating setpoints. Due to the difficulty of developing a physics-based surrogate model that can accurately match plant data in various operating conditions, machine learning algorithms are used in MPC, which allow for learning from both simulation and operation data, thus efficiently describing the targeted transient with arbitrary accuracy. However, one of the biggest concerns in applying ML algorithms like artificial neural networks (ANNs) is that the predictive capabilities of ANN are limited by training data. If there are gaps between the training and target domain, the accuracy of an ANN can degrade significantly when it is used to predict unseen data. To improve the predictive capability of ANN and enable a confident use of data-driven MPCs outside the training data, this study proposes an adaptive data-driven MPC framework. The system will monitor the discrepancy between plant responses and surrogate predictions, fine-tune the ANN-based surrogate when a large discrepancy is detected, and continue MPC operation with updated surrogates. The framework is demonstrated on a point kinetic model for microreactors. The hyperparameters of the update strategy, including layers to update, error thresholds, learning rate discount, and number of data points used for fine-tuning, are optimized so the simulated microreactor is able to follow changes in setpoint with the smallest of deviations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Method of Optimal Control for Class 8 Vehicle Platoons Over Hilly Terrain

This work develops and implements an NMPC control system to facilitate fuel-optimal platooning of Class 8 vehicles over challenging terrain. Prior research has shown that Cooperative Adaptive Cruise Control (CACC), which allows multiple Class 8 vehicles to follow in close succession, can save between 3 and 8% in overall fuel consumption on flat terrain. However, on more challenging terrain, e.g. rolling hills, platooning vehicles can experience diminished fuel savings, and, in some cases, an increase in fuel consumption relative to individual vehicle operation. This research explores the use of Nonlinear Model Predictive Control (NMPC) with predefined route grade profiles to allow platooning vehicles to generate an optimal velocity trajectory with respect to fuel consumption. In order to successfully implement the NMPC system, a model relating vehicle velocity to fuel consumption was generated and validated using experimental data. Additionally, the predefined route grade profiles were created by using the vehicle's GPS velocity over the desired terrain. The real-time NMPC system was then implemented on a two-truck platoon operating over challenging terrain, with a reference vehicle running individually. The results from NMPC platooning are compared against fuel results from a classical proportional-integral-derivative (PID) headway control method. Furthermore, this comparison yields the comparative fuel savings and energy efficiency benefit of NMPC system. In the final analysis, significant fuel savings of greater than 14 and 20% were seen for the lead and following vehicles relative to their respective traditional cruise control and platooning architectures.

33 ADVANCED PROPULSION SYSTEMS↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

Control Algorithms for Multi-Wavefront Sensor Adaptive Optics for Astronomical Exoplanet Imaging

This package consists of simulations of control algorithms being proposed for upcoming adaptive optics projects for exoplanet direct imaging, in which one wavefront affector (deformable mirror) is controlled by two wavefront sensors. Simulations include time-domain behavior under various assumed conditions, parameter optimization routines for the controllers, and stability analysis.

Sengupta, Aditya↗

Data from the Development Evolution of a Vehicle for Custom Control

In order to develop custom controllers intended to operate vehicles on a live highway, a series of data collection-focused tests were performed at increasing stages of complexity. Modern vehicles with features like Adaptive Cruise Control (ACC) feature a rich set of sensors and drive-by-wire mechanisms. The presented stages of data collection begins with the analysis of raw data provided by various vehicles, and eventually results in spoofing Controller Area Network (CAN) protocols for sending control commands to operate a vehicle. This paper covers the data and technical efforts needed at various stages. The raw data and tools to plot the data are also publicly available.

99 GENERAL AND MISCELLANEOUS↗