Search NASA⌕ Search

SEARCH · Search NASA

Results for “alternative water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Origin of Warrego Valles: A Case Study for Fluvial Valley Formation on Early Mars

Warrego Valles is one of the best examples of a well integrated fluvial valley system that formed early in the geological history of Mars, the lack of similar erosion elsewhere along the edge of Thaumasia plateau is not consistent with a formation by rainfall. Instead the radial pattern of this valley system centered on a region of localized uplift argues for a more localized water source. We conclude that this uplift was most likely the result of a subsurface magmatic intrusion and that the estimated volume of this intrusion is sufficient to cause enough hydrothermal ground-water outflow to form the valley system. A possible alternative to this scenario is hydrothermal ground-water outflow combined with a melting snow pack.

Gulick, Virginia C.↗

Sustainability assessment of alternative jet fuel for the U.S. Department of Defense

The United States Department of Defense (DoD) is considering replacing the 2.8 billion gallons of petroleum jet fuel consumed within the continental United States (CONUS) annually with alternative jet fuels to reduce vulnerability to price and supply fluctuations and improve sustainability. We evaluate the feasibility of replacing DoD CONUS jet fuel with alternative jet fuel from domestic feedstocks and assess the cost, greenhouse gas (GHG) emissions, energy balance, land, water, and fertilizer impacts of nine alternative jet fuel pathways. The feedstocks include terrestrial crops (soy, corn, wood, and grass), marine microalgae, and by-products (forestry residue, municipal solid waste, and waste oil) converted by extraction, fermentation, or thermo-chemical conversion, paired with upgrading steps. We found that domestic biomass feedstocks can meet the DoD CONUS jet fuel demand without significantly affecting food supply. Alternative pathways cost more than petroleum jet fuel ($0.78 l -1 and emitting 89 g CO 2 equivalent (CO 2e ) MJ -1 ), but many lowered GHG emissions. The forestry residue and waste oil pathways yielded the lowest costs ($\$0.92$ and $\$0.82$ l -1 , respectively), decreased emissions (23 and 35 g CO 2 e MJ -1 , respectively), and had negligible effects on land, water, and fertilizer resources. Finally, tradeoffs among sustainability metrics are further explored with a sensitivity analysis and by evaluating carbon-cost scenarios.

09 BIOMASS FUELS↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Methodology for Exploring Water and Hydropower Operating Criteria That Simultaneously Improve Economic and Environmental Considerations

Despite the reliability and flexibility of hydropower, the operation of hydroelectric power plants may have significant impacts on the downstream river system, including its water stage, sediment transport, and water temperature, ultimately affecting the ecology. To address these challenges, there is a need to identify water scheduling patterns that improve both hydropower economics and the environment relative to current operations. This paper presents a new methodology to explore promising operational criteria/rules that can achieve such improvements. Typical environmental impact statements and relicensing processes generally perform detailed site-specific analyses of a few alternatives that focus on reservoir water release operating rules and their associated environmental impacts. In contrast, the methodology presented in this article uses a widely applicable approach that explores a much larger solution space. This large set of potential alternatives can be represented in a multidimensional space for which one axis represents the economic value and the other axis quantify individual environmental impacts (e.g., sediment transport and fish growth), and they are explored via two approaches: a Monte Carlo simulation that identifies “win–win” alternatives and a multi-objective optimization problem that identifies Pareto-optimal alternatives.

13 HYDRO ENERGY↗

The faint young Sun paradox: an observational test of an alternative solar model

We report the results of deep observations at radio (3.6 cm) wavelengths of the nearby solar-type star pi 01 Ursa Majoris with the Very Large Array (VLA) intended to test an alternative theory of solar luminosity evolution. The standard model predicts a solar luminosity only 75% of the present value and surface temperatures below freezing on Earth and Mars at 4 Ga, seemingly in conflict with geologic evidence for liquid water on these planets. An alternative model invokes a compensatory mass loss through a declining solar wind that results in a more consistent early luminosity. The free-free emission from an enhanced wind around nearby young Sun-like stars should be detectable at microwave frequencies. Our observations of pi 01 UMa, a 300 million year-old solar-mass star, place an upper limit on the mass loss rate of 4-5 x 10(-11) M(solar) yr-1. Total mass loss from such a star over 4 Gyr would be less than 6%. If this star is indeed an analog of the early Sun, it casts doubt on the alternative model as a solution to the faint young Sun paradox, particularly for Mars.

NASA Discipline Exobiology↗

Gas-phase activation of holmium tetranitrato complexes likely leads to formation of hydroxylated species through the loss of nitric acid, not water splitting

It has been observed that water can react with activated gas-phase lanthanide tetranitrato complexes ([Ln(NO3)4]-) to form a hydroxylated species. These reactions, which are proposed to involve water splitting, are observed for most -- but not all -- of the lanthanides. Thus, study of this system could yield insight into how small changes in electronic structure (through variation of the lanthanide species) influences water-splitting reactions, help guide development of new materials used to convert water to hydrogen using electricity. The mechanism proposed in the literature is: (Step 1) [Ln(NO3)4]- ? [LnO(NO3)3]- + ?NO2 (Step 2) [LnO(NO3)3]- + H2O ? [LnOH(NO3)3]- + ?OH The purpose of this study is to determine if the reaction mechanism really does involve splitting of water or proceeds through an alternative pathway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Realizing the Residential Electrification Opportunity: One Heat Pump at a Time

Space and water heating in residential buildings is a major contributor of greenhouse gas (GHG) emissions in the United States. Advanced electric heat pumps (HP) and heat pump water heaters (HPWH) are poised to provide a low carbon alternative to traditional fossil-based space and water heating. Widespread deployment of heat pumps could help address the significant portion of building emissions and primary energy used in American households, however much work needs to be done to close the knowledge gap between like-for-like fossil equipment replacement and switching to HPs for the average contractor. The Pacific Northwest National Laboratory (PNNL) has been working on closing this knowledge gap through the development of decision tools and resources targeted towards contractors and installers. Developed in coordination with stakeholders and experienced contractors from a variety of geographic regions, these tools help streamline the process of sizing and selecting residential HPs and HPWHs for key use cases. Along with the complementary Retrofit Decision Tool developed by PNNL, the decision tools will help contractors understand the importance of whole building considerations when choosing HPs including envelope upgrades, duct assessments, and electrical assessments to ensure optimal selection and performance of the HP or HPWH. They also provide direct links to resources and best practices developed by PNNL as well as external entities to further help contractor education and training. This paper describes the development of these tools, and their role in moving the existing space and water heating market towards HPs to help realize the country’s decarbonization goals.

heat pump, heat pump water heater, Residential bui↗

Understanding Volume Estimation Uncertainty of Lakes and Wetlands Using Satellites and Citizen Science

We studied variations in the volume of water stored in small lakes and wetlands using satellite remote sensing and lake water height data contributed by citizen scientists. A total of 94 water bodies across the globe were studied using satellite data in the optical and microwave wavelengths from Landsat 8, Sentinel-1, and Sentinel-2. The uncertainty in volume estimation as a function of geography and geophysical factors, such as cloud cover, precipitation, and water surface temperature, was studied. The key finding that emerged from this global study is that uncertainty is highest in regions with a distinct precipitation season, such as in the monsoon dominated South Asia or the Pacific Northwestern region of the USA. This uncertainty is further compounded when small lakes and wetlands are seasonal with alternating land use as a water body and agricultural land, such as the wetlands of Northeastern Bangladesh. On an average, 45% of studied lakes could be estimated of their volume change with a statistical significant uncertainty that is less than the expected volume in South Asia. In North America, this statistically significant uncertainty in volume estimation was found to be around 50% in lakes eastward of the 108th meridian with lowest uncertainty found in lakes along the East coast of the USA. The article provides a baseline for understanding the current state of the art in estimating volumetric change of lakes and wetlands using citizen science in anticipation of the recently launched Surface Water and Ocean Topography Mission.

Shahzaib Khan↗

Can water mined on the moon save cost for life support?

The water needed for space life support has been so far provided by direct supply from Earth on most missions or by recycling on the International Space Station (ISS). With the recent reduction in launch cost, Earth resupply has become more attractive than recycling for lunar missions with smaller crews and briefer missions requiring less than 1,000 crew days. The third alternative supply method would use water mined from the lunar regolith. Continuing lunar research suggests that the moon may have more water, more widely distributed than previously expected. The cost of water mined on the moon will depend on its form and concentration, the machinery and operations required, and the overall demand for water. The use of oxygen and hydrogen for propulsion may greatly exceed the need for crew life support. The conditions under which water mined on the moon would be less expensive that water provided by resupply or recycling are described.

Harry W Jones↗

Continuous monitoring of bacterial attachment

A major concern with the Space Station Freedom (SSF) water supply system is the control of longterm microbial contamination and biofilm development in the water storage and distribution systems. These biofilms have the potential for harboring pathogens as well as microbial strains containing resistance factors that could negatively influence crew health. The proposed means for disinfecting the water system on SSF (iodine) may encourage the selection of resistant strains. In fact, biofilm bacteria were observed in water lines from the Space Shuttle Columbia (OV-102); therefore, an alternative remediation method is required to disinfect spacecraft water lines. A thorough understanding of colonization events and the physiological parameters that will influence bacteria adhesion is required. The limiting factor for development of this technology is the ability to continuously monitor adhesion events and the effects of biocides on sessile bacteria. Methods were developed to allow bacterial adhesion and subsequent biocidal treatment to be monitored continuously. This technique couples automated image analysis with a continuous flow of a bacterial suspension through an optical flow cell. A strain of Pseudomonas cepacia isolated from the water supply of the Space Shuttle Discovery (OV-103) during STS-39 was grown in a nitrogen-limited continuous culture. This culture was challenged continuously with iodine during growth, and the adhesion characteristics of this strain was measure with regard to flow rate. Various biocides (ozone, hypochlorite, and iodine) were added to the flow stream to evaluate how well each chemical removed the bacteria. After biocide treatment, a fresh bacterial suspension was introduced into the flow cell, and the attachment rate was evaluated on the previously treated surface. This secondary fouling was again treated with biocide to determine the efficacy of multiple batch chemical treatments in removing biofilm.

Koeing, D. W.↗

Conceptual design of a thermal control system for an inflatable lunar habitat module

NASA is considering the establishment of a manned lunar base within the next few decades. To house and protect the crew from the harsh lunar environment, a habitat is required. A proposed habitat is an spherical, inflatable module. Heat generated in the module must be rejected to maintain a temperature suitable for human habitation. This report presents a conceptual design of a thermal control system for an inflatable lunar module. The design solution includes heat acquisition, heat transport, and heat rejection subsystems. The report discusses alternative designs and design solutions for each of the three subsystems mentioned above. Alternative subsystems for heat acquisition include a single water-loop, a single air-loop, and a double water-loop. The vapor compression cycle, vapor absorption cycle, and metal hydride absorption cycle are the three alternative transport subsystems. Alternative rejection subsystems include flat plate radiators, the liquid droplet radiator, and reflux boiler radiators. Feasibility studies on alternatives of each subsystem showed that the single water-loop, the vapor compression cycle, and the reflux boiler radiator were the most feasible alternatives. The design team combined the three subsystems to come up with an overall system design. Methods of controlling the system to adapt it for varying conditions within the module and in the environment are presented. Finally, the report gives conclusions and recommendations for further study of thermal control systems for lunar applications.

Gadkari, Ketan↗

Parameterizing Perennial Bioenergy Crops in Version 5 of the Community Land Model Based on Site‐Level Observations in the Central Midwestern United States

Abstract With projected expansion of biofuel production at a global scale, there is a pressing need to develop adequate representation of bioenergy crops in land surface models to help effectively quantify the biogeophysical and biogeochemical effects of its associated land use changes. This study implements two new perennial bioenergy crops, Miscanthus and switchgrass, into the Community Land Model Version 5 based on site‐level observations from the midwestern United States by modifying parameters associated with photosynthesis, phenology, allocation, decomposition, and carbon cost of nitrogen uptake and integrating concomitantly land management practices. Sensitivity analyses indicate that carbon and energy fluxes of the perennial crops are most sensitive to photosynthesis and phenology parameters. Validation of simulated fluxes against site‐level measurements demonstrates that the model is capable of capturing the overall patterns of energy and carbon fluxes, as well as physiological transitions from leaf emergence to senescence. Compared to annual crops, perennial crops feature longer growing season, greater leaf areas, and higher productivity, leading to increased transpiration, lower annual runoff, and larger carbon uptake. The model simulations suggest that with higher CO 2 assimilation rates and lower demands for nutrients and water, high‐yielding perennial crops are promising alternatives of bioenergy feedstocks compared to traditional annual crops not only for mitigating climate change but also for environmental conservation purposes by reducing fertilizer application and therefore alleviating surface‐ and ground‐water contaminations. Although the local‐scale simulations shed light on potential benefits of using perennial grasses as bioenergy feedstocks, quantifying consequences of their plantations at larger scales warrants additional investigation.

Cheng, Yanyan↗

Intracycle RPM control for vertical axis wind turbines

The wind energy market is currently dominated by horizontal axis wind turbines (HAWTs); however, vertical axis wind turbines (VAWTs) are emerging as a design alternative, especially for deep-water offshore siting due to their low center of gravity, ease of access to drivetrain components, and overall simplicity. Due to the absence of a pitch mechanism in large-scale Darrieus VAWTs, stall control has often been used to manage power and loads. Introducing a pitching mechanism in H-type VAWTs has been studied, but this diminishes the mechanical simplicity advantage, and the use of a pitching mechanism in a large-scale Darrieus-type VAWT is not practical. This work examines an innovative, alternative method to control the rotor dynamics of a large-scale 5 MW VAWT to maximize power while constraining loads without introducing any new or complex mechanical elements. This control strategy is termed intracycle revolution per minute (RPM) control, where the rotational speed of the turbine is allowed to vary in an optimal fashion with the azimuthal location of blades as opposed to typical constant RPM operation. An optimization framework is formulated for an open-loop optimal control problem and solved to maximize power subject to constraints on aerodynamic design loads. Results are presented to demonstrate the benefits and the performance limits of intracycle RPM control for large-scale 5 MW Darrieus VAWTs, namely, (1) power production (quantified in terms of AEP) that can be increased subject to baseline load limits and (2) opportunities to significantly increase AEP or decrease loads via intracycle RPM control that are examined for both two-bladed and three-bladed VAWTs.

17 WIND ENERGY↗

Photochemical and Photophysical Dynamics of the Aqueous Ferrate(VI) Ion

Ferrate(VI) has the potential to play a key role in future water supplies. Furthermore, its salts have been suggested as “green” alternatives to current advanced oxidation and disinfection methods in water treatment, especially when combined with ultraviolet light to stimulate generation of highly oxidizing Fe(V) and Fe(IV) species. However, the nature of these intermediates, the mechanisms by which they form, and their roles in downstream oxidation reactions remain unclear. Here, we use a combination of optical and X-ray transient absorption spectroscopies to study the formation, interconversion, and relaxation of several excited-state and metastable high-valent iron species following excitation of aqueous potassium ferrate(VI) by ultraviolet and visible light. Branching from the initially populated ligand-to-metal charge transfer state into independent photophysical and photochemical pathways occurs within tens of picoseconds, with the quantum yield for the generation of reactive Fe(V) species determined by relative rates of the competing intersystem crossing and reverse electron transfer processes. Relaxation of the metal-centered states then occurs within 4 ns, while the formation of metastable Fe(V) species occurs in several steps with time constants of 250 ps and 300 ns. Results here improve the mechanistic understanding of the formation and fate of Fe(V) and Fe(IV), which will accelerate the development of novel advanced oxidation processes for water treatment applications.

54 ENVIRONMENTAL SCIENCES↗

Developing the Water Supply System for Travel to Mars

What water supply method should be used on a trip to Mars? Two alternate approaches are using fuel cell and stored water, as was done for short missions such as Apollo and the Space Shuttle, or recycling most of the water, as on long missions including the International Space Station (ISS). Stored water is inexpensive for brief missions but its launch mass and cost become very large for long missions. Recycling systems have much lower total mass and cost for long missions, but they have high development cost and are more expensive to operate than storage. A Mars transit mission would have an intermediate duration of about 450 days out and back. Since Mars transit is about ten times longer than a brief mission but probably less than one-tenth as long as ISS, it is not clear if stored or recycled water would be best. Recycling system design is complicated because water is used for different purposes, drinking, food preparation, washing, and flushing the urinal, and because wastewater has different forms, humidity condensate, dirty wash water, and urine and flush water. The uses have different requirements and the wastewater resources have different contaminants and processing requirements. The most cost-effective water supply system may recycle some wastewater sources and also provide safety reserve water from storage. Different water supply technologies are compared using mass, cost, reliability, and other factors.

water supply↗

Implementation and evaluation of the unified stomatal optimization approach in the Functionally Assembled Terrestrial Ecosystem Simulator (FATES)

Abstract. Stomata play a central role in regulating the exchange of carbon dioxide and water vapor between ecosystems and the atmosphere. Their function is represented in land surface models (LSMs) by conductance models. The Functionally Assembled Terrestrial Ecosystem Simulator (FATES) is a dynamic vegetation demography model that can simulate both detailed plant demographic and physiological dynamics. To evaluate the effect of stomatal conductance model formulation on forest water and carbon fluxes in FATES, we implemented an optimality-based stomatal conductance model – the Medlyn (MED) model – that simulates the relationship between photosynthesis (A) and stomatal conductance to water vapor (gsw) as an alternative to the FATES default Ball–Woodrow–Berry (BWB) model. To evaluate how the behavior of FATES is affected by stomatal model choice, we conducted a model sensitivity analysis to explore the response of gsw to climate forcing, including atmospheric CO2 concentration, air temperature, radiation, and vapor pressure deficit in the air (VPDa). We found that modeled gsw values varied greatly between the BWB and MED formulations due to the different default stomatal slope parameters (g1). After harmonizing g1 and holding the stomatal intercept parameter (g0) constant for both model formulations, we found that the divergence in modeled gsw was limited to conditions when the VPDa exceeded 1.5 kPa. We then evaluated model simulation results against measurements from a wet evergreen forest in Panama. Results showed that both the MED and BWB model formulations were able to capture the magnitude and diurnal changes of measured gsw and A but underestimated both by about 30 % when the soil was predicted to be very dry. Comparison of modeled soil water content from FATES to a reanalysis product showed that FATES captured soil drying well, but translation of drying soil to modeled physiology reduced the models' ability to match observations. Our study suggests that the parameterization of stomatal conductance models and current model response to drought are the critical areas for improving model simulation of CO2 and water fluxes in tropical forests.

54 ENVIRONMENTAL SCIENCES↗

Distribution of water on Mars: Implications from SNC meteorites

There has been much speculation about the abundance of water and other volatiles on Mars. Attempts to calculate abundances of water on Mars indicate that Mars contains approx. 10-100 m of water. Numerous models have been put forth to determine the amount of water on Mars more closely. Some researchers infer that Chassigny parent magma contained greater than 1.5 percent water by weight and that the Martian mantle contained greater than 1000 parts per million water. This is too much water for a depleted region. Perhaps some of the water in Chassigny was assimilated at shallow depths, either in a crustal magma chamber or by interaction with superficial permafrost. Either is possible and provides an alternative to the dilemma of water-rich to depleted regions.

Jones, J. H.↗

Desalinating a Real Hyper-Saline Pre-Treated Produced Water via Direct-Heat Vacuum Membrane Distillation

Membrane distillation (MD) is an emerging thermal desalination technology capable of desalinating waters of any salinity. During typical MD processes, the saline feedwater is heated and acts as the thermal energy carrier; however, temperature polarization (as well as thermal energy loss) contributes to low distillate fluxes, low single-pass water recovery and poor thermal efficiency. An alternative approach is to integrate an extra thermal energy carrier as part of the membrane and/or module assembly, which can channel externally provided heat directly to the membrane-feedwater interface and/or along the feed channel length. This direct-heat delivery has been demonstrated to increase single-pass water recovery and enhance the overall thermal efficiency. We developed a bench-scale direct-heated vacuum MD (DHVMD) process to desalinate pre-treated oil and gas "produced water" with an initial total dissolved solids of 115,500 ppm at a feed temperature ranging between 24 and 32 degrees C. We evaluated both water flux and specific energy consumption (SEC) as a function of water recovery. The system achieved a 50% water recovery without significant scaling, with an average flux >6 kg m-2 hr-1 and a SEC as low as 2,530 kJ kg-1. The major species of mineral scales (i.e., NaCl, CaSO4, and SrSO4) that limited the water recovery to 68% were modeled in terms of thermodynamics and identified by scanning electron microscopy and energy-dispersive X-ray spectroscopy. In addition, we further developed and employed a physics-based process model to estimate temperature, salinity, water transport and energy flows for full-scale vacuum MD and DHVMD modules. Model results show that a direct-heat input rate of 3,600 W can increase single-pass water recovery from 2.1% to 3.1% while lowering the thermal SEC from 7,800 kJ kg-1 to 6,517 kJ kg-1 in an unoptimized module. Finally, the scaling up potential of DHVMD process is briefly discussed.

brine↗