Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Four-Sector Cylindrical Radio-Frequency Ion Trap

Proposed linear radio-frequency ion trap consists of closed metal cylinder partitioned into four equal cylindrical-sector electrodes and two circular end electrodes. Features include relatively large ion-storage capacity and shielding against external fields. Used in frequency-standard laboratories to confine 199Hg+ ions electrodynamically in isolation from external environment. Similar to device described in "Linear Ion Trap for Atomic Clock" (NPO-17758).

Melbourne, Ruthann K.↗

Gravity and the geoid in the Nepal Himalaya

Materials within the Himalaya are rising due to convergence between India and Asia. If the rate of erosion is comparable to the rate of uplift, the mean surface elevation will remain constant. Any slight imbalance in these two processes will lead to growth or attrition of the Himalaya. Although buried rocks, minerals and surface control points in the Himalaya are undoubtably rising, the growth or collapse or the Himalaya depends on the erosion rate which is invisible to geodetic measurements. A way to measure erosion rate is to measure the rate of change of gravity in a region of uplift. Essentially gravity should change precisely in accord with a change in elevation of the point in a free air gradient if erosion equals uplift rate. A measurement of absolute gravity was made simultaneously with measurements of GPS height within the Himalaya. Absolute gravity is estimated from the change in velocity per unit distance of a falling corner cube in a vacuum. Time is measured with an atomic clock and the unit distance corresponds to the wavelength of an iodine stabilized laser. An experiment undertaken in the Himalaya in 1991 provide a site description also with a instrument description.

Bilham, Roger↗

Comparison of GPS and GLONASS common-view time transfers

It was already shown than even with a simple daily averaging of GLONASS data at each site, continental GLONASS time transfer can be achieved at a level of several tens of nanoseconds. A further step is to carry out observations of GLONASS satellites by the common-view method. A comparison of GPS and GLONASS common-view time transfers between Russia and Western Europe are reported. At each site, a GPS receiver and a GLONASS receiver are connected to the same atomic clock. Both GPS receivers are of NBS type and the GLONASS receivers are of type A-724. As GPS common-view time transfer between Sevres and Mendeleevo is accomplished at a level of a few nanoseconds in precision, it gives an excellent reference with which to evaluate the performance of GLONASS common-view time transfer.

Lewandowski, W.↗

MIL-STDS and PTTI: What's available and what needs to be done

The systems developer who needs Precise Time and Time Interval (PTTI) capability has relatively little guidance in the form of military standards, particularly for systems using atomic clocks or other sources of very precise time and frequency. The existing standards, including MIL-STD-188-115, MIL-F-2991(EC), and DOD-STD-1399 are discussed. These documents were written several years ago and do not always reflect current practice or take advantage of more recent technology improvements. User needs have also changed over the years and some of those needs such as more detailed time codes are not being met. We will summarize what's available and what's good and bad about it. The second part will make suggestions about what should be done in the future to promote and facilitate good PTTI design practice. Topics will include clock performance parameters, environmental considerations, time codes, signal isolation, and time dissemination.

Murray, James A.↗

Comparison of LASSO and GPS time transfers

The LASSO is a technique which should allow the comparison of remote atomic clocks with sub-nanosecond precision and accuracy. The first successful time transfer using LASSO has been carried out between the Observatoire de la Cote d'Azur in France and the McDonald Observatory in Texas, United States. This paper presents a preliminary comparison of LASSO time transfer with GPS common-view time transfer.

Lewandowski, W.↗

Role of the BIPM in UTC Dissemination to the Real Time User

The generation and dissemination of International Atomic Time (TAI), and Coordinated Universal Time (UTC) are explicitly mentioned in the list of principal tasks of the Bureau International des Poids et Mesures (BIPM), that appears in the Compes Rendus of the the 18e Conference Generales des Poids et Measures, in 1987. These time scales are used as the ultimate reference in the most demanding scientific applications and must, therefore, be of the best metrological quality in terms of reliability, long term stability, and conformity of the scale interval with the second, the unit of time of the International System of Units. To meet these requirements, it is necessary that the readings of the atomic clocks, spread all over the world, that are used as basic timing data for TAI and UTC generation, must be combined in the most efficient way possible. In particular, to take full advantage of the quality of each contributing clock calls for observation of its performance over a sufficiently long time. At present, the computation period treats data in blocks covering two months. TAI and UTC are thus deferred-time scales that cannot be immediately available to real-time users. The BIPM can, nevertheless be of help to real-time users. The predictability of UTC is a fundamental attribute of the scale for institutions responsible for the dissemination of real-time time scales. It allows them to improve their local representations of UTC and, thus, implement a more thorough steering of the time scales diffused in real-time. With a view to improving the predicatbility of UTC, the BIPM examines in detail timing techniques and basic theories in order to propose alternative solutions for timing algorithms. This, coupled with a recent improvement of timing data, makes UTC more stable and thus, more predictable. At a more practical level, effort is being devoted to putting in place automatic procedures for reducing the time needed for data collection and treatment: monthly results are already available ten days earlier than before.

Quinn, T. J.↗

Upper Limit of Weights in TAI Computation

The international reference time scale International Atomic Time (TAI) computed by the Bureau International des Poids et Mesures (BIPM) relies on a weighted average of data from a large number of atomic clocks. In it, the weight attributed to a given clock depends on its long-term stability. In this paper the TAI algorithm is used as the basis for a discussion of how to implement an upper limit of weight for clocks contributing to the ensemble time. This problem is approached through the comparison of two different techniques. In one case, a maximum relative weight is fixed: no individual clock can contribute more than a given fraction to the resulting time scale. The weight of each clock is then adjusted according to the qualities of the whole set of contributing elements. In the other case, a parameter characteristic of frequency stability is chosen: no individual clock can appear more stable than the stated limit. This is equivalent to choosing an absolute limit of weight and attributing this to to the most stable clocks independently of the other elements of the ensemble. The first technique is more robust than the second and automatically optimizes the stability of the resulting time scale, but leads to a more complicated computatio. The second technique has been used in the TAI algorithm since the very beginning. Careful analysis of tests on real clock data shows that improvement of the stability of the time scale requires revision from time to time of the fixed value chosen for the upper limit of absolute weight. In particular, we present results which confirm the decision of the CCDS Working Group on TAI to increase the absolute upper limit by a factor of 2.5. We also show that the use of an upper relative contribution further helps to improve the stability and may be a useful step towards better use of the massive ensemble of HP 507IA clocks now contributing to TAI.

Thomas, Claudine↗

Spacecraft Tests of General Relativity

Current spacecraft tests of general relativity depend on coherent radio tracking referred to atomic frequency standards at the ground stations. This paper addresses the possibility of improved tests using essentially the current system, but with the added possibility of a space-borne atomic clock. Outside of the obvious measurement of the gravitational frequency shift of the spacecraft clock, a successor to the suborbital flight of a Scout D rocket in 1976 (GP-A Project), other metric tests would benefit most directly by a possible improved sensitivity for the reduced coherent data. For purposes of illustration, two possible missions are discussed. The first is a highly eccentric Earth orbiter, and the second a solar-conjunction experiment to measure the Shapiro time delay using coherent Doppler data instead of the conventional ranging modulation.

Anderson, John D.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

Fermion Superfluidity

Dual evaporation gives 50 million fermions at T = 0.1 T(sub F). Demonstrated suppression of interactions by coherent superposition - applicable to atomic clocks. Looking for evidence of Cooper pairing and superfluidity.

Strecker, Kevin↗

Physics in NASA Exploration

The primary focus of the workshop was NASA's new concentration on sending crewed missions to the Moon by 2020, and then on to Mars and beyond. Several speakers, including JPL s Fred O Callaghan and NASA's Mark Lee, broached the problem that there is now a serious reduction of capability to perform experiments in the ISS, or to fly significant mass in microgravity by other means. By 2010, the shuttle fleet will be discontinued and Russian craft will provide the only access to the ISS. O Callaghan stated that the Fundamental Physics budget is being reduced by 70%. LTMPF and LCAP are slated for termination. However, ground-based experiments are continuing to be funded at present, and it will be possible to compete for $80-90 million in new money from the Human Research Initiative (HRI). The new program thrust is for exploration, not fundamental physics. Fundamental, we were told by Lee, does not ring well in Washington these days. Investigators were advised to consider how their work can benefit missions to the Moon and Mars. Work such as that regarding atomic clocks is looked upon with favor, for example, because it is considered important to navigation and planetary GPS. Mark Lee stressed that physicists must convey to NASA senior management that they are able and willing to contribute to the new exploration research programs. The new mentality must be we deliver products, not do research. This program needs to be able to say that it is doing at least 50% exploration-related research. JPL s Ulf Israelsson discussed the implications to OBPR, which will deliver methods and technology to assure human health and performance in extraterrestrial settings. The enterprise will provide advanced life-support systems and technology that are reliable, capable, simpler, less massive, smaller, and energy-efficient, and it may offer other necessary expertise in areas such as low-gravity behavior. Like Dr. Lee, he stated that the focus must be on products, not research. While there is not yet a formal direction, he said, LTMPF and PARCS ISS flight projects are slated to terminate in October 2004. All flight investigations are being returned to ground programs and phased out by the end of FY07. Physics ground programs are intact for now, but to survive we must shift about 50% of research to supporting exploration. Basic research programs in other disciplines are being cancelled. Product lines will support human health, safety and life-support, including countermeasures against radiation and other hazards, as well as advances in time-keeping, navigation and communications technologies. Israelsson said that the new Fundamental Physics for Exploration Roadmap points to how fundamental physics research can and does support exploration. JPL will use the roadmap to argue for support for fundamental physics research under several codes. Nicholas Bigelow of the University of Rochester encouraged attendees not to become discouraged, but rather to embrace the opportunities presented by NASA's new direction.

O'Callaghan, Fred↗

Miniaturized Mercury Ion Clock for Ultrastable Deep Space Applications

We have recently completed a prototype ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~2-3x10-13 at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly 1.5 years with no measurable degradation of ion trapping lifetimes or clock short-term performance. Because the tube is sealed, the Hg source and Neon buffer gas are held indefinitely, for the life of the tube. There is no consumption of Hg in this system unlike in a Cs beam tube where lifetime is often limited by Cs depletion.

mercury ion clocks↗

System using leo satellites for centimeter-level navigation

Disclosed herein is a system for rapidly resolving position with centimeter-level accuracy for a mobile or stationary receiver [4]. This is achieved by estimating a set of parameters that are related to the integer cycle ambiguities which arise in tracking the carrier phase of satellite downlinks [5,6]. In the preferred embodiment, the technique involves a navigation receiver [4] simultaneously tracking transmissions [6] from Low Earth Orbit Satellites (LEOS) [2] together with transmissions [5] from GPS navigation satellites [1]. The rapid change in the line-of-sight vectors from the receiver [4] to the LEO signal sources [2], due to the orbital motion of the LEOS, enables the resolution with integrity of the integer cycle ambiguities of the GPS signals [5] as well as parameters related to the integer cycle ambiguity on the LEOS signals [6]. These parameters, once identified, enable real-time centimeter-level positioning of the receiver [4]. In order to achieve high-precision position estimates without the use of specialized electronics such as atomic clocks, the technique accounts for instabilities in the crystal oscillators driving the satellite transmitters, as well as those in the reference [3] and user [4] receivers. In addition, the algorithm accommodates as well as to LEOS that receive signals from ground-based transmitters, then re-transmit frequency-converted signals to the ground.

Rabinowitz, Matthew↗

NASA Tech Briefs, May 2008

Topics covered inclde: Deployable Wireless Camera Penetrators; Hand-Held Units for Short-Range Wireless Biotelemetry; Wearable Wireless Telemetry System for Implantable BioMEMS Sensors; Electronic Escape Trails for Firefighters; Architecture for a High-to-Medium-Voltage Power Converter; 24-Way Radial Power Combiner/Divider for 31 to 36 GHz; Three-Stage InP Submillimeter-Wave MMIC Amplifier; Fast Electromechanical Switches Based on Carbon Nanotubes; Solid-State High-Temperature Power Cells; Fast Offset Laser Phase-Locking System; Fabricating High-Resolution X-Ray Collimators; Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves; Flipperons for Improved Aerodynamic Performance; System Estimates Radius of Curvature of a Segmented Mirror; Refractory Ceramic Foams for Novel Applications; Self-Deploying Trusses Containing Shape-Memory Polymers; Fuel-Cell Electrolytes Based on Organosilica Hybrid Proton Conductors; Molecules for Fluorescence Detection of Specific Chemicals; Cell-Detection Technique for Automated Patch Clamping; Redesigned Human Metabolic Simulator; Compact, Highly Stable Ion Atomic Clock; LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells; Compact Dielectric-Rod White-Light Delay Lines; Single-Mode WGM Resonators Fabricated by Diamond Turning; Mitigating Photon Jitter in Optical PPM Communication; MACOS Version 3.31; Fiber-Optic Determination of N2, O2, and Fuel Vapor in the Ullage of Liquid-Fuel Tanks; Spiking Neurons for Analysis of Patterns; Symmetric Phase-Only Filtering in Particle-Image Velocimetry; Efficient Coupler for a Bessel Beam Dispersive Element; and Attitude and Translation Control of a Solar Sail Vehicle.

Source record↗

Compact Microwave Mercury Ion Clock for Deep-Space Applications

We have recently completed a breadboard ion-dock physics package based on Kg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability -1-2xl0-13 at 1 second, averaging to 10-15 at 1 day. This development shows that 8- maser quality stabilities can be produced in a small clock package, comparable in size to an oItra-stable quartz oscillator required for holding 1-2xl0-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only agetter pump was used to maintain vacuum. The vacuum tube containing the traps has now been onder sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a - 400 C tube bake-out to prepare for tube sealoff. This approach to the vacuum follows the methods used in mght vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligable diffusion losses will occur over the operation lifetime.

space clock↗

Prospects for Interdisciplinary Science Aboard the International Space Station

The assembly of the International Space Station was completed in early 2011, and is now embarking on its first year of the coming decade of use as a laboratory. Two key types of physical science research are enabled by ISS: studies of processes that are normally masked by gravity, and instruments that take advantage of its position as a powerful platform in orbit. The absence of buoyancy-driven convection enables experiments in diverse areas such as fluids near the critical point, Marangoni convection, combustion, and coarsening of metal alloys. The positioning of such a powerful platform in orbit with robotic transfer and instrument support also provides a unique alternative platform for astronomy and physics instruments. Some of the operating or planned instruments related to fundamental physics on the International Space Station include MAXI (Monitoring all-sky X-ray Instrument for ISS), the Alpha Magnetic Spectrometer, CALET (Calorimetric Electron Telescope), and ACES (Atomic Clock Experiment in Space). The presentation will conclude with an overview of pathways for funding different types of experiments from NASA funding to the ISS National Laboratory, and highlights of the streamlining of services to help scientists implement their experiments on ISS.

Robinson, Julie A.↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗

Carbon Nanofiber-Based, High-Frequency, High-Q, Miniaturized Mechanical Resonators

High Q resonators are a critical component of stable, low-noise communication systems, radar, and precise timing applications such as atomic clocks. In electronic resonators based on Si integrated circuits, resistive losses increase as a result of the continued reduction in device dimensions, which decreases their Q values. On the other hand, due to the mechanical construct of bulk acoustic wave (BAW) and surface acoustic wave (SAW) resonators, such loss mechanisms are absent, enabling higher Q-values for both BAW and SAW resonators compared to their electronic counterparts. The other advantages of mechanical resonators are their inherently higher radiation tolerance, a factor that makes them attractive for NASA s extreme environment planetary missions, for example to the Jovian environments where the radiation doses are at hostile levels. Despite these advantages, both BAW and SAW resonators suffer from low resonant frequencies and they are also physically large, which precludes their integration into miniaturized electronic systems. Because there is a need to move the resonant frequency of oscillators to the order of gigahertz, new technologies and materials are being investigated that will make performance at those frequencies attainable. By moving to nanoscale structures, in this case vertically oriented, cantilevered carbon nanotubes (CNTs), that have larger aspect ratios (length/thickness) and extremely high elastic moduli, it is possible to overcome the two disadvantages of both bulk acoustic wave (BAW) and surface acoustic wave (SAW) resonators. Nano-electro-mechanical systems (NEMS) that utilize high aspect ratio nanomaterials exhibiting high elastic moduli (e.g., carbon-based nanomaterials) benefit from high Qs, operate at high frequency, and have small force constants that translate to high responsivity that results in improved sensitivity, lower power consumption, and im - proved tunablity. NEMS resonators have recently been demonstrated using topdown, lithographically fabricated ap - proaches to form cantilever or bridgetype structures. Top-down approaches, however, rely on complicated and expensive e-beam lithography, and often require a release mechanism. Reso - nance effects in structures synthesized using bottom-up approaches have also recently been reported based on carbon nanotubes, but such approaches have relied on a planar two-dimensional (2D) geometry. In this innovation, vertically aligned tubes synthesized using a bottom- up approach have been considered, where the vertical orientation of the tubes has the potential to increase integration density even further. The simulation of a vertically oriented, cantilevered carbon nanotube was performed using COMSOL Multi - physics, a finite element simulation package. All simulations were performed in a 2D geometry that provided consistent results and minimized computational complexity. The simulations assumed a vertically oriented, cantilevered nanotube of uniform density (1.5 g/cu cm). An elastic modulus was assumed to be 600 GPa, relative permittivity of the nanotube was assumed to be 5.0, and Poisson s ratio was assumed to be 0.2. It should be noted that the relative permittivity and Poisson s ratio for the nanotubes of interest are not known accurately. However, as in previous simulations, the relative permittivity and Poisson s ratios were treated as weak variables in the simulation, and no significant changes were recognized when these variables were varied.

Kaul, Anupama B.↗