Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Computer Program and User Documentation Medical Data Input System

Several levels of documentation are presented for the program module of the NASA medical directorate minicomputer storage and retrieval system. The biomedical information system overview gives reasons for the development of the minicomputer storage and retrieval system. It briefly describes all of the program modules which constitute the system. A technical discussion oriented to the programmer is given. Each subroutine is described in enough detail to permit in-depth understanding of the routines and to facilitate program modifications. The program utilization section may be used as a users guide.

Anderson, J.↗

User and Task Analysis of the Flight Surgeon Console at the Mission Control Center of the NASA Johnson Space Center

Astronauts in a space station are to some extent like patients in an intensive care unit (ICU). Medical support of a mission crew will require acquisition, transmission, distribution, integration, and archiving of significant amounts of data. These data are acquired by disparate systems and will require timely, reliable, and secure distribution to different communities for the execution of various tasks of space missions. The goal of the Comprehensive Medical Information System (CMIS) Project at Johnson Space Center Flight Medical Clinic is to integrate data from all Medical Operations sources, including the reference information sources and the electronic medical records of astronauts. A first step toward the full CMIS implementation is to integrate and organize the reference information sources and the electronic medical record with the Flight Surgeons console. In order to investigate this integration, we need to understand the usability problems of the Flight Surgeon's console in particular and medical information systems in general. One way to achieve this understanding is through the use of user and task analyses whose general purpose is to ensure that only the necessary and sufficient task features that match users capacities will be included in system implementations. The goal of this summer project was to conduct user and task analyses employing cognitive engineering techniques to analyze the task of the Flight Surgeons and Biomedical Engineers (BMEs) while they worked on Console. The techniques employed were user interviews, observations and a questionnaire to collect data for which a hierarchical task analysis and an information resource assessment were performed. They are described in more detail below. Finally, based on our analyses, we make recommendations for improvements to the support structure.

Johnson, Kathy A.↗

Cardiovascular Session Summary

It was apparent that the bed-rest and spaceflight data indicated that decreases in plasma volume and cardiac atrophy along with cardiac remodeling were fundamental changes which predisposed many astronauts to post flight orthostatic intolerance. Despite the recently acquired in-flight and post-flight muscle sympathetic nerve activity findings suggesting that the sympathetic nerve responses were appropriate there remains significant contrary data from bed-rest studies, post- flight stand tests and hind-limb unweighted rat studies that suggest that the vasoconstrictive responses were compromised at least insufficient in susceptible individuals. The key issues raised is whether a diminished increase in sympathetic activity from baseline without changes in 254 First Biennial Space Biomedical Investigators'Workshop Cardiovascular peak response or receptor adaptations is an abnormal response or is an individual variance of response to the accentuated decrease in stroke volume. Data relating autonomic neural control of heart rate were presented to suggest that the vagal and sympathetic control of heart rate was attenuated. Also, bed-rest and space flight induced attenuated baroreflex control of heart rate was shown to be restored to pre-bedrest function by one bout of maximal dynamic exercise. However, these data were confounded by relying on the use of R-R interval as a measure of efferent responses of the baroreflex during a condition in which the baseline heart rate was changed. Clearly the idea that the autonomic control of heart rate may be changed by microgravity needs further investigation. This direction is suggested despite the fact that in the triple product (HR x SV x TPR = MAP) assessment of the regulation of arterial blood pressure during orthostasis the role of the HR reflex may be less influential than that associated. with cardiac atrophy (SV changes) and aberrant sympathetic vasoconstriction (resistance) changes. Although sympathetic nerve activity responses in-flight and post-flight on neurolab appeared appropriate, enough bed-rest and post-flight stand test data, along with animal model data suggest that vasoconstriction was compromised. The mechanism of this compromised vasoconstriction needs to be delineated. Other major findings concerning microgravity and physiological regulatory systems are that: I . Thermoregulatory adaptation appear to suggest some decrements in the control of cutaneous vasodilation and sweating; 2. Calcium resorption and dietary calcium need to be defined for differing durations of spaceflight, especially as the effects of excess calcium on vasomotor function appears to be detrimental; 3. Neurohumoral mechanisms of microgravity induced changes in neural function and the regulation of plasma volume and total body water, bone resorption and autonomic neural control of the circulation need further delineation; 4. As performance of work tasks become prolonged, the mechanisms of blood pressure regulation in microgravity needs to be used in the recovery period from prolonged work tasks.

Raven, Peter↗

A multichannel electromagnetic flowmeter telemetry system.

An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.

Fryer, T. B.↗

Operations planning simulation model extension study. Volume 1: Long duration exposure facility ST-01-A automated payload

Ground processing and operation activities for selected automated and sortie payloads are evaluated. Functional flow activities are expanded to identify payload launch site facility and support requirements. Payload definitions are analyzed from the launch site ground processing viewpoint and then processed through the expanded functional flow activities. The requirements generated from the evaluation are compared with those contained in the data sheets. The following payloads were included in the evaluation: Long Duration Exposure Facility; Life Sciences Shuttle Laboratory; Biomedical Experiments Scientific Satellite; Dedicated Solar Sortie Mission; Magnetic Spectrometer; and Mariner Jupiter Orbiter. The expanded functional flow activities and descriptions for the automated and sortie payloads at the launch site are presented.

Marks, D. A.↗

Joint U.S./U.S.S.R. Study Of Effects Of Bed Rest

Horizontal and head-down positions investigated at two research centers. Report presents results of joint experimental study of effects of bed rest conducted at Ames Research Center in California and Institute for Biomedical Problems in Moscow. Study conducted under identical conditions at both locations. In addition to generating useful scientific data, provided basis for comparison of physiological reactions and standardization of procedures and methods.

Sandler, H.↗

The graphics and data acquisition software package

A software package was developed for use with micro and minicomputers, particularly the LSI-11/DPD-11 series. The package has a number of Fortran-callable subroutines which perform a variety of frequently needed tasks for biomedical applications. All routines are well documented, flexible, easy to use and modify, and require minimal programmer knowledge of peripheral hardware. The package is also economical of memory and CPU time. A single subroutine call can perform any one of the following functions: (1) plot an array of integer values from sampled A/D data, (2) plot an array of Y values versus an array of X values; (3) draw horizontal and/or vertical grid lines of selectable type; (4) annotate grid lines with user units; (5) get coordinates of user controlled crosshairs from the terminal for interactive graphics; (6) sample any analog channel with program selectable gain; (7) wait a specified time interval, and (8) perform random access I/O of one or more blocks of a sequential disk file. Several miscellaneous functions are also provided.

Crosier, W. G.↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Development of Telemedicine Capabilities for a Joint US-Russian Space Biomedical Center for Training and Research

From the perspective of scheduling, some medical consultations can have asynchronous and synchronous components. Consultations frequently involve the compilation of patient data, its analysis, a consultant's report, and a real-time conference between the referring physician and the consultant. The bandwidth of the Internet with Moscow and advances in the hardware and software of personal computing now make possible telemedicine events with store-and-forward components and real-time components. These are hybrid telemedicine and this paper describes such a case.

DeBakey, Michael E.↗

Rhythmic variation in heart rate and respiration rate during space flight - Apollo 15

As part of the operational biomedical monitoring for Apollo manned missions, ECG and respiration rate are telemetered at selected intervals to mission control. The data were collected as part of this monitoring program. These data were evaluated for circadian and ultradian rhythmicity because of their uniqueness. The ability to detect and quantitate biorhythms in living systems during space flight is an important aspect of evaluating hypotheses concerning the underlying mechanisms of these phenomena. Circadian variation in heart rate during space flight is demonstrated here. In analyzing generated time series data it has been found that period discrimination is much better than the theoretical limit.

Rummel, J. A.↗

An integrative approach to space-flight physiology using systems analysis and mathematical simulation

An approach was developed to aid in the integration of many of the biomedical findings of space flight, using systems analysis. The mathematical tools used in accomplishing this task include an automated data base, a biostatistical and data analysis system, and a wide variety of mathematical simulation models of physiological systems. A keystone of this effort was the evaluation of physiological hypotheses using the simulation models and the prediction of the consequences of these hypotheses on many physiological quantities, some of which were not amenable to direct measurement. This approach led to improvements in the model, refinements of the hypotheses, a tentative integrated hypothesis for adaptation to weightlessness, and specific recommendations for new flight experiments.

Leonard, J. I.↗

Video Image Communication And Retrieval - Updated

Video Image Communication and Retrieval (VICAR) package of computer programs is general-purpose image-processing software system. Intended for processing data from Jet Propulsion Laboratory's unmanned planetary spacecraft, now used in variety of other applications, including processing of biomedical images, cartography, studies of Earth resources, and geological exploration. Development of newest version of VICAR emphasizes standardized, easily-understood user interface, shield between user and host operating system, and comprehensive array of image-processing capabilities.

Wall, Ray J.↗

Biomedical and Human Factors Requirements for a Manned Earth Orbiting Station

The primary objective of this study is to determine which biomedical and human factors measurements must be made aboard a space station to assure adequate evaluation of the astronaut's health and performance during prolonged space flights. The study has employed, where possible, a medical and engineering systems analysis to define the pertinent life sciences and space station design parameters and their influence on a measurement program. The major areas requiring evaluation in meeting the study objectives include a definition of the space environment, man's response to the environment, selection of measurement and data management techniques, experimental program, space station design requirements, and a trade-off analysis with final recommendations. The space environment factors that are believed to have a significant effect on man were evaluated. This includes those factors characteristic of the space environment (e. g. weightlessness, radiation) as well as those created within the space station (e. g. toxic contaminants, capsule atmosphere). After establishing the general features of the environment, an appraisal was made of the anticipated response of the astronaut to each of these factors. For thoroughness, the major organ systems and functions of the body were delineated, and a determination was made of their anticipated response to each of the environmental categories. A judgment was then made on the medical significance or importance of each response, which enabled a determination of which physiological and psychological effects should be monitored. Concurrently, an extensive list of measurement techniques and methods of data management was evaluated for applicability to the space station program. The various space station configurations and design parameters were defined in terms of the biomedical and human factors requirements to provide the measurements program. Research design of experimental programs for various station configurations, mission durations, and crew sizes were prepared, and, finally, a trade-off analysis of the critical variables in the station planning was completed with recommendations to enhance the confidence in the measurement program.

EARTH ORBIT↗

Computer program and user documentation medical data tape retrieval system

This volume provides several levels of documentation for the program module of the NASA medical directorate mini-computer storage and retrieval system. A biomedical information system overview describes some of the reasons for the development of the mini-computer storage and retrieval system. It briefly outlines all of the program modules which constitute the system.

Anderson, J.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Multidimensional perspectives of geo-epidemiology: from interdisciplinary learning and research to cost–benefit oriented decision-making

Research typically promotes two types of outcomes (inventions and discoveries), which induce a virtuous cycle: something suspected or desired (not previously demonstrated) may become known or feasible once a new tool or procedure is invented and, later, the use of this invention may discover new knowledge. Research also promotes the opposite sequence—from new knowledge to new inventions. This bidirectional process is observed in geo-referenced epidemiology—a field that relates to but may also differ from spatial epidemiology. Geo-epidemiology encompasses several theories and technologies that promote inter/transdisciplinary knowledge integration, education, and research in population health. Based on visual examples derived from geo-referenced studies on epidemics and epizootics, this report demonstrates that this field may extract more (geographically related) information than simple spatial analyses, which then supports more effective and/or less costly interventions. Actual (not simulated) bio-geo-temporal interactions (never captured before the emergence of technologies that analyze geo-referenced data, such as geographical information systems) can now address research questions that relate to several fields, such as Network Theory. Thus, a new opportunity arises before us, which exceeds research: it also demands knowledge integration across disciplines as well as novel educational programs which, to be biomedically and socially justified, should demonstrate cost-effectiveness. Grounded on many bio-temporal-georeferenced examples, this report reviews the literature that supports this hypothesis: novel educational programs that focus on geo-referenced epidemic data may help generate cost-effective policies that prevent or control disease dissemination.

59 BASIC BIOLOGICAL SCIENCES↗

Operational plans for life science payloads - From experiment selection through postflight reporting

Key features of operational plans developed in a study of the Space Shuttle era life science payloads program are presented. The data describes the overall acquisition, staging, and integration of payload elements, as well as program implementation methods and mission support requirements. Five configurations were selected as representative payloads: (a) carry-on laboratories - medical emphasis experiments, (b) mini-laboratories - medical/biology experiments, (c) seven-day dedicated laboratories - medical/biology experiments, (d) 30-day dedicated laboratories - Regenerative Life Support Evaluation (RLSE) with selected life science experiments, and (e) Biomedical Experiments Scientific Satellite (BESS) - extended duration primate (Type I) and small vertebrate (Type II) missions. The recommended operational methods described in the paper are compared to the fundamental data which has been developed in the life science Spacelab Mission Simulation (SMS) test series. Areas assessed include crew training, experiment development and integration, testing, data-dissemination, organization interfaces, and principal investigator working relationships.

Mccollum, G. W.↗

Coherent inductive communications link for biomedical applications

A two-way coherent inductive communications link between an external transceiver and an internal transceiver located in a biologically implanted programmable medical device. Digitally formatted command data and programming data is transmitted to the implanted medical device by frequency shift keying the inductive communications link. Internal transceiver is powered by the inductive field between internal and external transceivers. Digitally formatted data is transmitted to external transceiver by internal transceiver amplitude modulating inductive field. Immediate verification of the establishment of a reliable communications link is provided by determining existence of frequency lock and bit phase lock between internal and external transceivers.

Hogrefe, Arthur F.↗