Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration and fitting methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

186 records · Page 11

New Measurements of the Cosmic Infrared Background Fluctuations in Deep SpitzerllRAC Survey Data and their Cosmological Implications

We extend the previous measurements of CIB fluctuations to angular scales of less than or equal to 1 degree new data obtained in the course of the 2,000+ hour Spitzer Extended Deep Survey. Two fields with completed observations of approximately equal to 12 hr/pixel are analyzed for source-subtracted CIB fluctuations at 3.6 and 4.5 micrometers. The fields, EGS and UDS, cover a total area of approximately 0.25 deg and lie at high Galactic and Ecliptic latitudes, thus minimizing cirrus and zodiacal light contributions to the fluctuations. The observations have been conducted at 3 distinct epochs separated by about 6 months. As in our previous studies, the fields were assembled using the self-calibration method which is uniquely suitable for probing faint diffuse backgrounds. The assembled fields were cleaned off the bright sources down to the low shot noise levels corresponding to AB mag approximately equal to 25, Fourier-transformed and their power spectra evaluated. The noise was estimated from the time-differenced data and subtracted from the signal isolating the fluctuations remaining above the noise levels. The power spectra of the source-subtracted fields remain identical (within the observational uncertainties) for the three epochs of observations indicating that zodiacal light contributes negligibly to the fluctuations. By comparing to the measurements for the same regions at 8 micrometers we demonstrate that Galactic cirrus cannot account for the levels of the fluctuations either. The signal appears isotropically distributed on the sky as required by its origin in the CIB fluctuations. This measurement thus extends our earlier results to the important range of sub-degree scales. We find that the CIB fluctuations continue to diverge to more than 10 times those of known galaxy populations on angular scales out to less than or equal to 1 degree. The low shot noise levels remaining in the diffuse maps indicate that the large scale fluctuations arise from spatial clustering of faint sources well within the confusion noise. The spatial spectrum of these fluctuations is in reasonable agreement with simple fitting assuming that they originate in early populations spatially distributed according to the standard cosmological model (ACDM) at epochs coinciding with the first stars era. The alternative to this identification would require a new population never observed before, nor expected on theoretical grounds, but if true this would represent an important discovery in its own right.

Kashlinsky, A.↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Mapping tall shrub biomass in Alaska at landscape scale using structure-from-motion photogrammetry and lidar

Warming in arctic and boreal regions is increasing shrub cover and biomass. In southcentral Alaska, willow (Salix spp.) and alder (Alnus spp.) shrubs grow taller than many tree species and account for a substantial proportion of aboveground biomass, yet they are not individually measured as part of the operational Forest Inventory and Analysis (FIA) Program. The goal of this research was to test methods for landscape-scale mapping of tall shrub biomass in upper montane and subalpine environments using FIA-type plot measurements (n = 51) and predictor variables from imagery-based structure-from-motion (SfM) and airborne lidar. Specifically, we compared biomass models constructed from imagery acquired by unmanned aerial vehicle (UAV; ~1.7 cm pixels), imagery from the NASA Goddard's Lidar, Hyperspectral, and Thermal Airborne Imager (G-LiHT; ~3.1 cm pixels), and concomitant G-LiHT small-footprint lidar. Tall shrub biomass was most accurately predicted at 5 m resolution (R^2 = 0.81, RMSE = 1.09 kg/sq. m) using G-LiHT SfM color and structure variables. Lidar-only models had lower precision (R^2 = 0.74, RMSE = 1.26 kg/sq. m), possibly due to reduced model information content from variable multicollinearity or lower data density. Separate models for upper montane zones with trees and shrubs and subalpine zones with only shrubs were always chosen over single models based on minimization of Akaike's Information Criterion, indicating the need for variable sets robust to overhanging tree canopy. Decreasing point density from UAV (5000–8000 pts./sq. m) to the G-LiHT SfM point cloud (500–2000 pts./sq. m) had little impact on model fit, suggesting that high-resolution airborne imagery can extend SfM approaches well beyond line-of-sight restrictions for UAV platforms. Overall, our results confirmed that SfM from high-resolution imagery is a viable approach to estimate shrub biomass in the boreal region, especially when an existing lidar terrain model and local field calibration data are available to quantify uncertainty in the SfM point cloud and landscape-scale estimates of shrub biomass.

Michael Alonzo↗

CIRCLEZ : Reliable photometric redshifts for active galactic nuclei computed solely using photometry from Legacy Survey Imaging for DESI

Photometric redshifts for galaxies hosting an accreting supermassive black hole in their center, known as active galactic nuclei (AGNs), are notoriously challenging. At present, they are most optimally computed via spectral energy distribution (SED) fittings, assuming that deep photometry for many wavelengths is available. However, for AGNs detected from all-sky surveys, the photometry is limited and provided by a range of instruments and studies. This makes the task of homogenizing the data challenging, presenting a dramatic drawback for the millions of AGNs that wide surveys such as SRG/eROSITA are poised to detect. This work aims to compute reliable photometric redshifts for X-ray-detected AGNs using only one dataset that covers a large area: the tenth data release of the Imaging Legacy Survey (LS10) for DESI. LS10 provides deep grizW1-W4 forced photometry within various apertures over the footprint of the eROSITA-DE survey, which avoids issues related to the cross-calibration of surveys. We present the results from CIRCLEZ, a machine-learning algorithm based on a fully connected neural network. CIRCLEZ is built on a training sample of 14 000 X-ray-detected AGNs and utilizes multi-aperture photometry, mapping the light distribution of the sources. The accuracy (σNMAD) and the fraction of outliers (η) reached in a test sample of 2913 AGNs are equal to 0.067 and 11.6%, respectively. The results are comparable to (or even better than) what was previously obtained for the same field, but with much less effort in this instance. We further tested the stability of the results by computing the photometric redshifts for the sources detected in CSC2 and Chandra-COSMOS Legacy, reaching a comparable accuracy as in eFEDS when limiting the magnitude of the counterparts to the depth of LS10. The method can be applied to fainter samples of AGNs using deeper optical data from future surveys (for example, LSST, Euclid), granting LS10-like information on the light distribution beyond the morphological type. Along with this paper, we have released an updated version of the photometric redshifts (including errors and probability distribution functions) for eROSITA/eFEDS.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration and validation of the foundation for a multiphase strength model for tin

In this work, the Common Model of Multi-phase Strength and Equation of State (CMMP) model was applied to tin. Specifically, calibrations of the strength-specific elements of the CMMP foundation were developed with a combination of experiments and theory, and then the model was validated experimentally. The first element of the foundation is a multi-phase analytic treatment of the melt temperature and the shear modulus for the solid phases. These models were parameterized for each phase based on ab initio calculations using the software VASP (Vienna Ab initio Simulations Package) based on density functional theory. The shear modulus model for the ambient phase was validated with ultrasonic sound speed measurements as a function of pressure and temperature. The second element of the foundation is a viscoplastic strength model for the phase, upon which strength for inaccessible higher-pressure phases can be scaled as necessary. The stress–strain response of tin was measured at strain rates of 10 -3 to 3 x 10 3 s -1 and temperatures ranging from 87 to 373 K. The Preston–Tonks–Wallace (PTW) strength model was fit to that data using Bayesian model calibration. For validation, six forward and two reverse Taylor impact experiments were performed at different velocities to measure large plastic deformation of tin at strain rates up to ⁠10 5 s -1 . The PTW model accurately predicted the deformed shapes of the cylinders, with modest discrepancies attributed to the inability of PTW to capture the effects of twinning and dynamic recrystallization. Some material in the simulations of higher velocity Taylor cylinders reached the melting temperature, thus testing the multiphase model because of the presence of a second phase, the liquid. In simulations using a traditional modeling approach, the abrupt reduction of strength upon melt resulted in poor predictions of the deformed shape and non-physical temperatures. With CMMP, the most deformed material points evolved gradually to a mixed solid–liquid but never a fully liquid state, never fully lost strength, stayed at the melt temperature as the latent heat of fusion was absorbed, and predicted the deformed shape well.

36 MATERIALS SCIENCE↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗