Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurement of mean excitation energies of neutrino-relevant materials

Modern neutrino experiments require precision reconstruction of events. A crucial component of this reconstruction is the stopping power for charged particles, calculated using the Bethe equation. The main free parameter of the Bethe equation is the mean excitation energy (the "I-value"), which in most cases cannot be calculated, but must be measured for each substance. In many cases, the values are derived from very old experiments with large quoted uncertainties, or worse, small quoted uncertainties and inadequate treatment of systematics. Even if the tabulated values were reliable to the necessary degree, the I-value is affected by the phase of the substance and by chemical bonding, and only rough heuristics have been developed to convert measurements of single elements into I-values for compounds or from one phase to another. Modern neutrino experiments which need to measure an absolute energy scale, while lacking calibration sources, suffer the most from uncertainties in the I-value. DUNE is a primary example. We are performing measurements with the 400MeV Fermilab LINAC beam at the Irradiation Test Facility. We describe our efforts to measure the I-value of liquid argon, as well as those for several other materials used in past, present and potential future neutrino experiments, including water, NOvA scintillator, MINOS steel, zirconium, and molybdenum. These measurements use a set of degraders to scan the beam energy around the Bragg peak for each substance to determine the proton range. Experimental results are compared to results from Geant4 and FLUKA to determine the I-value.

Strait, Matthew L. [Fermilab] (ORCID:0000000157088↗

Long-Term Stability Metrics of Photoelectrochemical Water Splitting

Photoelectrochemical (PEC) water splitting, one of the most promising technologies for clean hydrogen generation, has drawn considerable attention over the past few decades. Achieving simultaneous highly efficient and stable unassisted PEC water splitting has been the “holy grail” in clean and renewable fuel generation. State-of-the-art photoelectrodes have shown relatively high efficiencies (∼10–20%). Still, their stability is limited due to photoelectrode chemical instability, electrolyte resistance, mass transfer issues, and an often unoptimized experimental setup. In this work, we present a framework and a set of protocols for conducting long-term stability experiments and further provide details on several critical factors such as light source calibration, choosing the right counter electrode, the configuration of the PEC cell, and photoelectrode sample preparation.

08 HYDROGEN↗

Optimization of La 2–x Sr x CuO 4 Single Crystal Film Growth via Molecular Beam Epitaxy

Atomic layer-by-layer molecular beam epitaxy (ALL-MBE) combined with ozone is one of the best methods to fabricate single-crystal thin films of complex oxides. Cuprate such as La 2-x Sr x CuO 4 (LSCO) is a representative complex-oxide high-temperature superconductor (HTS) material. Our group utilizes this method to produce high-quality single-crystal HTS films with atomically smooth surfaces and interfaces. In addition, ALL-MBE enables us to engineer multilayer heterostructures with atomic precision. This allows the fabrication of tunnel junctions, various nanostructures, and other HTS devices of interest for superconducting electronics. We have synthesized over three thousand LSCO thin films in the past two decades. These films’ structural and electronic properties have been studied and characterized by various methods. Here, we distill the extensive experience we accumulated into a step-by-step protocol to fabricate atomically perfect LSCO films. The recipe includes substrate preparation, ozone generation and distillation, source calibration, the in situ monitoring of the film synthesis, post-growth annealing, and ex situ characterization. It discloses a reproducible way to fabricate single-crystal LSCO films for basic research and HTS electronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ozone and aerosol size distribution measurements at the Oliktok Point, AK AMF3

Aerosol size distribution measurements at the Oliktok Point, AK AMF3 as measured by a TSI model 3082 scanning mobility particle sizer (SMPS), and ozone measurements at the Oliktok Point, AK AMF3 as measured by a 2B model 205 ozone monitor. 2B specifies a limit of detection (2σ) of 2 ppb and these data were calibrated using a 2B model 306 ozone calibration source. Users of the data are asked to contact PI Pratt prior to use for consultation, discussion of co-authorship, and to ensure that the most up-to-date information is provided.

54 ENVIRONMENTAL SCIENCES↗

Rotary shutter mechanism contains optical elements

Two cylindrical shutter mechanisms having fixed outer sleeves and rotating inner sleeves use single stepping motor and Geneva mechanism to sequentially move optical components into path of ultraviolet monochromator for output control to photomultiplier. Photometric and wavelength calibration sources insure shutter positions according to operational phases.

Weilbach, A. O.↗

Thermal scanner data for studying freeze conditions and for aiding irrigation scheduling

The use of thermal imagery in connection with plant water stress appears to hold considerable potential, particularly with scanners such as the RS-14 where internal calibration sources can be adjusted to bracket the temperatures of interest. The data from the thermal film are fairly easy to reduce; however, data reduction in 3 days or less would be required before it could be used in irrigation timing.

Bartholic, J. F.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Earth resources sensing technology - 24-channel multispectral sensor system development.

Description of the technology applied to a 24-channel multispectral scanner developed as a tool to investigate the portion of the electromagnetic spectrum between 0.34 and 13.0 microns. Energy reflected or emitted from the terrain and system calibration sources is collected by the scan mirror, reflected into the collecting optics, and brought to focus in a plane containing a square aperture. A dichroic optical element splits the energy which passes through the aperture into two wavelength bands in which wavelengths are greater than and less than 2.0 microns, respectively. These two wavelength bands are dispersed spectrally by two grating spectrometers. The energy from 24 distinct spectral intervals is transformed into electrical signals by 24 detector/preamplifier combinations. These signals then become the inputs to a video processor in an airborne electronics console.

Kessel, J. E.↗

Remote sensing technology - The 24-channel multispectral scanner.

The multispectral scanner system installed in the NASA C-130 aircraft for use in the Earth Observations Aircraft Program constitutes a 24-channel imaging spectrometer that senses electromagnetic energy in the spectral interval from .34 to 13 microns. Energy reflected or emitted from the terrain and system calibration sources is collected by a scan mirror, reflected into collecting optics, and brought to a focus in a plane containing a 0.09 inch square aperture. A dichroic optical element splits the energy which passes through the aperture into two wavelength bands (wavelengths above and below 2 microns). These wavelength bands are then dispersed spectrally into 24 distinct spectral bands by two grating spectrometers. The spectral intervals are transformed into electrical signals by separate detector-preamplifier combinations, and the signals are used as inputs to a video processor in an airborne electronics console. System operation and performance are described.

Hayre, H. S.↗

Design and performance characteristics of the Vertical Temperature Profile Radiometer /VTPR/ for atmospheric temperature soundings.

Description of the design and operation of a radiometer which derives atmospheric temperature profiles on the basis of spectral measurements in eight optical filter channels. The radiometer achieves its eight-channel capability by sequentially viewing the eight optical filters mounted in a rotating filter wheel, with a single IR detector and electronic amplification channel processing the signal for all the filters. The advantages and disadvantages of this sequential approach as compared to eight 'parallel' radiometric channels are discussed. The proposed radiometer provides a relative calibration accuracy between seven out of the eight channels of better than 0.1% rms of the full dynamic range. The absolute accuracy achievable between in-flight calibrations of six minutes, or between two-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the in-flight calibration source of the instrument and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

The radiometer transfer function for the AAFE composite two-frequency radiometer scatterometer

A model was developed for the switching radiometer utilizing a continuous method of calibration. Sources of system degradation were identified and include losses and voltage standing wave ratios in front of the receiver input. After computing the three modes of operation, expressions were developed for the normalized radiometer output, the minimum detectable signal (normalized RMS temperature fluctuation), sensitivity, and accuracy correction factors).

Moore, J. H.↗

Solar radiometry at millimeter wavelengths

In the area of resolution enhancement, the use of Fast Fourier Transform programs was investigated for possible application to millimeter wavelength maps of the sun. A difficulty arises with the La Posta maps in that they are limited to 35 arc-minutes square while the smeared out solar image is larger than that. A list of possible cometary emission lines near 13 millimeters is presented. Although preparation of the list was inspired by the appearance of Comet Kohoutek, the results are applicable to any future comet. The brightness temperature of the sun at 8.6 millimeters was measured using the moon as a calibration source. The result does not confirm a deep absorption feature as apparently observed by earlier workers.

Henze, W.↗

Design and performance characteristics of the vertical temperature profile radiometer /VTPR/ for atmospheric temperature soundings

Various design characteristics and performance achievements of the vertical temperature profile radiometer (VTPR) are discussed. It is shown that the VTPR provides a relative calibration accuracy of better than 0.1% rms of the full dynamic range and has been operating successfully in space on the ITOS spacecraft for more than eleven months. The absolute accuracy achievable between in-flight calibrations of 6 minutes, or between 2-hour calibrations using optical temperature correction factors, is better than an rms value of 0.15% of full scale. The radiometric correlation between the VTPR in-flight calibration source and a reference standard blackbody is better than an rms value of 0.5% of full scale.

Falbel, G.↗

Absolute brightness temperature measurements at 2.1-mm wavelength

Absolute measurements of the brightness temperatures of the Sun, new Moon, Venus, Mars, Jupiter, Saturn, and Uranus, and of the flux density of DR21 at 2.1-mm wavelength are reported. Relative measurements at 3.5-mm wavelength are also preented which resolve the absolute calibration discrepancy between The University of Texas 16-ft radio telescope and the Aerospace Corporation 15-ft antenna. The use of the bright planets and DR21 as absolute calibration sources at millimeter wavelengths is discussed in the light of recent observations.

Ulich, B. L.↗

A balloon-borne cryogenically cooled filter radiometer

The development of a cryogenically cooled filter radiometer for use with high altitude balloons is discussed. The radiometer has features which include the options for remote operation of two filter wheels each containing six filters at helium temperature and a cryogenic rotary chopper which may be run at 200 cycles per second or positioned open or closed, and a remotely operable chopped blackbody calibration source. The radiometer contains a ten inch diameter liquid nitrogen cooled Cassegrain telescope with nine individually filtered field stops in the focal plane. The telescope is mounted on a two-axis servo operated gimbal which is used to make sky scans under the control of an onboard programmer.

Debell, A. G.↗