Emerging investigator series: local pH effects on carbon oxidation in capacitive deionization architectures

In this work, the effect of pH and potential is examined for the oxidation of carbon cloth electrodes used in capacitive deionization (CDI) processes. The degree of oxidation of the electrode surface, examined using the electrode's potential of zero charge (E pzc ) and measured using chronoamperometry and cyclic voltammetry, is found to be strongly correlated to the pH of the solution at the interface. Local pH measurements are examined at anodes and cathodes in full CDI and membrane-assisted capacitive deionization (MCDI) cells at cell voltages ranging from 0.3–1.2 V. The cathode is shown to be basic under charging potentials while the anode is found to be acidic. This local pH is found to be highly transient during charging and discharging in CDI cells while the pH is found to be relatively static in the MCDI cells, maintaining a basic pH at the cathode and an acidic pH at the anode even when the cell is discharged. Ion exchange membranes (IEM) are found to have two functions: (1) limiting co-ion expulsion that results from specific ion adsorption and (2) limiting the effects of parasitic Faradaic reactions on the separation process by stabilizing the local pH thereby mitigating dissolved oxygen reduction at the cathode and lessening carbon oxidation at the anode. Performance comparisons including the salt adsorption capacity and charge efficiency are also compared for these systems.

54 ENVIRONMENTAL SCIENCES↗

Use of in Situ Synchrotron Techniques to Probe the Oxidized Surface of Molybdenum Nitride Oxygen Reduction Electrocatalysis

The development of active and stable earth-abundant catalysts for the oxygen reduction reaction (ORR) is needed for widespread, economic development of fuel cell technologies. Designing and optimizing these non-platinum group metals is challenging, however, because they are susceptible to composition and structure changes, including dissolution, oxidation, and corrosion, both in air and under reaction conditions. To identify the active surface, and thus understand the properties that affect activity, the catalyst surface must be characterized in situ. Herein, we utilize a grazing incidence electrochemical cell to investigate in situ composition and morphology changes of a molybdenum nitride (Mo-N) thin film catalyst using grazing incidence x-ray absorption spectroscopy (GI-XAS) and x-ray reflectivity (XRR). In rotating ring disk electrode measurements, we find that the activity, selectivity, stability, and capacitance of the Mo-N catalyst is dependent on the maximum potential to which it has been exposed. Specifically, the overpotential required to reach -2 mA cm-2geo decreases by over 90 mV when the maximum potential is increased from 0.3 to 0.8 V vs RHE (Figure 1). Because the Mo-N oxidizes rapidly in air, ex situ characterization methods including x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry can provide only limited insight into these in situ catalyst changes. Using in situ GI-XAS measurements at applied potentials between 0.3 and 0.9 V vs RHE, however, we are able to determine that the surface of the film oxidizes and becomes more amorphous when exposed to increasingly higher potentials (Figure 1). Furthermore, the surface remains oxidized on the order of several hours when returned to "ORR relevant potentials" (< 0.6 V vs RHE), indicating that this surface-oxidized nitride is the active surface for ORR. Using in situ XRR measurements, we find that there is no change in surface roughness at potentials below 0.7 V vs RHE, but the film roughens significantly at 0.8 V vs RHE, correlating with ex situ measurements of Mo dissolution at this potential (Figure 1). We therefore conclude that the intrinsic activity of the Mo-N catalyst increases when exposed to potentials up to 0.7 V vs RHE, while above that potential activity enhancements are due to the exposure of more active sites through dissolution. The in situ electrochemical surface-sensitive x-ray characterization as used here is a promising methodology for understanding and leveraging surface dynamics to improve the performance of non-traditional catalysts.

Kreider, Melissa↗

The Electrochemical Properties of Sr(Ti,Fe)O 3-δ for Anodes in Solid Oxide Fuel Cells

Reduction-stable mixed ionic and electronic conductors such as Sr(Ti,Fe)O 3-δ (STF) are promising materials for application in anodes of solid oxide fuel cells. The defect chemistry of STF and its properties as solid oxide fuel cell (SOFC) cathode have been studied thoroughly, while mechanistic investigations of its electrochemical properties as SOFC anode material are still scarce. In this study, thin film model electrodes of STF with 30% and 70% Fe content were investigated in H 2 +H 2 O atmosphere by electrochemical impedance spectroscopy. Lithographically patterned thin film Pt current collectors were applied on top or beneath the STF thin films to compensate for the low electronic conductivity under reducing conditions. Oxygen exchange resistances, electronic and ionic conductivities and chemical capacitances were quantified and discussed in a defect chemical model. Increasing Fe content increases the electro-catalytic activity of the STF surface as well as the electronic and ionic conductivity. Current collectors on top also increase the electrochemical activity due to a highly active Pt-atmosphere-STF triple phase boundary. Furthermore, the electrochemical activity depends decisively on the H 2 :H 2 O mixing ratio and the polarization. Lastly, Fe 0 nanoparticles may evolve on the surface in hydrogen rich atmospheres and increase the hydrogen adsorption rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electric field distribution in a non-self-sustained RF discharge with ionization generated by Ns discharge pulses

Abstract Electric field in a capacitively coupled, non-self-sustained RF discharge nitrogen plasma with external ionization generated by high-voltage ns pulses has been measured by ps Electric field induced second harmonic generation (EFISH). The measurements are made both in the bulk of the plasma and in the sheaths, using the absolute calibration by the Laplacian field between two plane electrodes. The results are compared with the kinetic modeling calculations. The RF electric field in the sheaths is significantly higher compared to that in the plasma, due to the displacement of the electrons by the drift oscillations and the resultant plasma self-shielding. However, the kinetic modeling predictions indicate that the electron impact ionization in the sheaths is largely ineffective, due to the low electron density. The reduction of the electric field in the plasma by the self-shielding in the sheaths is moderate, such that the energy is coupled to the plasma by the below-breakdown RF field. The peak RF field in the plasma is in the range of 15–25 Td, indicating the efficient vibrational excitation of N 2 by electron impact. The modeling predictions suggest that the targeted vibrational excitation of molecular species in a non-self-sustained RF discharge with external ionization is scalable to high pressures, electron densities, and discharge powers. The present approach can be extended to the vibrational excitation of other molecular species where the vibrational relaxation is relatively slow, such as CO, CO 2 , and H 2 .

Physics↗

Interfacial Engineering Using Covalent Organic Frameworks in Polymer Composites for High‐Temperature Electrostatic Energy Storage

Abstract The use of inorganic nanofillers has been an effective method to improve high‐temperature capacitive performance of dielectric polymers, though there are unmet challenges such as undesirable organic–inorganic compatibility, and low efficiencies and energy densities. Herein, a surface functionalization strategy using covalent organic frameworks (COFs) is employed to address such challenges in realizing high‐performing polymer composites. Specifically, core–shell structured nanoparticles, where ZrO 2 nanoparticles act as the core and a COF material forms the shell, are constructed and composited with the polyetherimide (PEI) matrix. The design leverages the high electron affinity ( E A ) of the outer COF shell to create energy traps, thereby capturing free charges and limiting electrical conduction. Concurrently, the low E A and wide bandgap of the ZrO 2 core introduce energy barriers to impede charge injection and migration. This orchestrated “energy level cascade” results in a marked reduction of leakage current and energy loss. The resulting polymer composite showcases an impressive discharged energy density of 6.21 J cm −3 at an efficiency above 90%, with a maximum discharged energy density reaching 7.43 J cm −3 at 150 °C. These performance metrics position the PEI/ZrO 2 @COF polymer composite to surpass or be on par with state‐of‐the‐art high‐temperature PEI composites and other advanced polymer dielectrics.

Xie, Zongliang↗

Electron energy distribution functions measured by Langmuir probe with optical emission spectroscopy in very high frequency capacitive discharge in nitrogen

By using a rf compensated Langmuir probe and optical emission spectroscopy, the effects of driving frequency (13.56-50 MHz) on the electron energy probability function (EEPF), electron density, electron temperature, and the vibrational and rotational temperatures in capacitively coupled nitrogen discharge were investigated. Measurements were performed in the pressure range 60-200 mTorr, and at a fixed voltage of 140 V (peak-to-peak). With increasing the driving frequency, the dissipated power and electron density markedly increased along with the intensity of the optical emission lines belonging to the 2nd positive (337.1 nm) and 1st negative systems (391.4 nm) of N{sub 2}. The EEPF at low pressure 60 mTorr is two-temperature (bi-Maxwellian) distribution, irrespective of the driving frequency, in contrast with argon and helium discharges in the similar conditions. The mechanism forming such bi-Maxwellian shape was explained by two combined effects: one is the collisionless sheath-heating effect enhancing the tail electron population, and the other is the collision-induced reduction of electrons at the energy 2-4 eV where the collision cross-section for the vibrational excitation has a resonantly large peak. The two-temperature EEPF structure was basically retained at moderate pressure 120 mTorr and high pressure 200 mTorr. The vibrational temperature T{sub vib} and rotational temperature T{sub rot} are measured for the sequence ({Delta}{nu}=-2) of N{sub 2} second positive system (C{sup 3}{Pi}{sub u}{yields}B{sup 3}{Pi}{sub g}) using the method of comparing the measured and calculated spectra with a chi-squared minimization procedure. It was found that, both of T{sub vib} and T{sub rot} are a weakly dependent on driving frequency at low pressure 60 mTorr. At higher pressure (120 and 200 mTorr), T{sub vib} rises monotonically with the driving frequency, whereas the T{sub rot} slightly decreases with frequency below 37 MHz, beyond which it relatively increases or saturated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Influence of Cr-Additives on the Polarization Resistance of Praseodymium-Doped Ceria Cathodes for Solid Oxide Fuel Cells

While Cr poisoning of the oxygen reduction reaction (ORR) at SOFC cathodes is widely agreed to involve deactivation of oxygen exchange sites, the degradation mechanism remains ambiguous. Here, we selected an alternative cathode material Pr 0.1 Ce 0.9 O 2− δ , free of Sr segregation, to systematically investigate the effect of Cr-induced degradation in ORR. We expand on our previous studies in which the acidity/basicity of binary additives was found to be a strong indicator of the rate of oxygen surface exchange, by electrochemically investigating the ORR activity of the PCO cathode by impedance spectroscopy. Serial infiltration with acidic Cr-based oxides was found to degrade ORR activity as reflected in a 20-fold increase in area specific resistance (ASR) without corresponding changes in activation energy, with the opposite trend obtained with Ca-based oxides. Detected changes in total capacitance, attributed to changes in surface capacitance, also suggest depressed/enhanced PCO surface redox behavior with Cr/Ca-based infiltrants. Taken together, these results point to a more universal source of ORR poisoning/activation, based on acidity/basicity, rather than physical blocking of active sites. With this improved understanding, one can expect progress to be made in the coming years in optimizing means for protecting catalytic surfaces from degradation and/or improving their performance.

25 ENERGY STORAGE↗

Oxygen Reduction Reaction Measurements on Platinum Electrocatalysts Utilizing Rotating Disk Electrode Technique: I. Impact of Impurities, Measurement Protocols and Applied Corrections

The rotating disk electrode (RDE) technique is being extensively used as a screening tool to estimate the activity of novel PEMFC electrocatalysts synthesized in lab-scale (mg) quantities. Discrepancies in measured activity attributable to glassware and electrolyte impurity levels, as well as conditioning, protocols and corrections are prevalent in the literature. Moreover, the electrochemical response to a broad spectrum of commercially sourced perchloric acid and the effect of acid molarity on impurity levels and solution resistance were also assessed. Our findings reveal that an area specific activity (SA) exceeding 2.0 mA/cm 2 (20 mV/s, 25°C, 100 kPa, 0.1 M HClO 4 ) for polished poly-Pt is an indicator of impurity levels that do not impede the accurate measurement of the ORR activity of Pt based catalysts. After exploring various conditioning protocols to approach maximum utilization of the electrochemical area (ECA) and peak ORR activity without introducing catalyst degradation, an investigation of measurement protocols for ECA and ORR activity was conducted. Down-selected protocols were based on the criteria of reproducibility, duration of experiments, impurity effects and magnitude of pseudo-capacitive background correction. In sum, statistical reproducibility of ORR activity for poly-Pt and Pt supported on high surface area carbon was demonstrated.

14 SOLAR ENERGY↗

Stirring and peristaltic pumping alter flow electrode particle size and morphology

Flowable carbon-based electrodes are widely studied in electrochemical systems for energy storage and water treatment. Most laboratory- and pilot-scale studies employ active mixing for slurry preparation and handling and use peristaltic pumps for slurry circulation. Magnetic stirring is the most prevalent mixing method at the laboratory scale, and the combination of magnetic mixing and peristaltic pumping is favored for convenience and compatibility with particulate suspensions. However, these methods can strongly affect particle size and morphology (and therefore cell performance). In this study, we evaluate how mixing and pumping influence particle degradation in two commonly used carbon materials: spherical carbon black (CB) beads and powdered activated carbon (AC). We performed 24 h stirring-only experiments using magnetic, orbital, and overhead stirring. Separately, we conducted 32 h circulation experiments using a commercial peristaltic pump. Particle morphology and size were analyzed using optical microscopy and laser diffraction. The initially spherical CB beads (~580 μm, 1.5 wt%) exhibit rapid and extensive breakdown under both peristaltic pumping and magnetic stirring. By comparison, AC particles (initially ~31 μm) tested at 1.5 and 15 wt% showed measurable size reductions of up to ~25 % under either stirring or pumping. In conclusion, these findings highlight the need to account for and quantify morphological changes caused by both stirring and pumping in the design and associated evaluation of flowable electrode systems.

Chemistry↗

Characterization of Resistances of a Capacitive Deionization System

Capacitive deionization (CDI) is a promising desalination technology, which operates at low pressure, low temperature, requires little infrastructure, and has the potential to consume less energy for brackish water desalination. However, CDI devices consume significantly more energy than the theoretical thermodynamic minimum, and this is at least partly due to resistive power dissipation. We here report our efforts to characterize electric resistances in a CDI system, with a focus on the resistance associated with the contact between current collectors and porous electrodes. We present an equivalent circuit model to describe resistive components in a CDI cell. We propose measurable figures of merit to characterize cell resistance. We also show that contact pressure between porous electrodes and current collectors can significantly reduce contact resistance. As a result, we propose and test an alternative electrical contact configuration which uses a pore-filling conductive adhesive (silver epoxy) and achieves significant reductions in contact resistance.

36 MATERIALS SCIENCE↗

Catalyst layer formulations for slot-die coating of PEM fuel cell electrodes

The series of electrodes were fabricated by the scalable and manufacturable slot-die coating method for proton exchange membrane fuel cell (PEMFC) application. The inks with different amounts of solids were studied by rheological methods in order to establish a coating window with minimum manufacturing defects. The obtained electrodes were characterized by SEM, AFM, and optical microscopy, which showed that they were uniform and homogeneous with minimum defects. The electrochemical evaluation of the manufactured gas diffusion electrodes (GDE) showed that the main characteristics of the electrodes, like electrochemical surface area, proton resistivity, and double layer capacitance, were found to be close for all samples confirming the reproducibility of the slot-die process. Additionally, we studied the effects of membrane thickness on the performance of the GDE membrane electrode assemblies and determined that a decrease in membrane thickness favored the performance. Furthermore, the obtained results clearly demonstrated the applicability and feasibility of the approach for the Manufacturing of catalyst layers for the fuel cell application with potential for future mass production.

08 HYDROGEN↗

Characterization of NAADP-mediated calcium signaling in human spermatozoa

Highlights: •Human sperm cells synthesize NAADP. •NAADP-AM mediates [Ca{sup 2+}]{sub i} increases in human sperm in the absence of [Ca{sup 2+}]{sub o}. •Human sperm have two acidic compartments located in the head and midpiece. -- Abstract: Ca{sup 2+} signaling in spermatozoa plays a crucial role during processes such as capacitation and release of the acrosome, but the underlying molecular mechanisms still remain unclear. Nicotinic acid adenine dinucleotide phosphate (NAADP) is a potent Ca{sup 2+}-releasing second messenger in a variety of cellular processes. The presence of a NAADP synthesizing enzyme in sea urchin sperm has been previously reported, suggesting a possible role of NAADP in sperm Ca{sup 2+} signaling. In this work we used in vitro enzyme assays to show the presence of a novel NAADP synthesizing enzyme in human sperm, and to characterize its sensitivity to Ca{sup 2+} and pH. Ca{sup 2+} fluorescence imaging studies demonstrated that the permeable form of NAADP (NAADP-AM) induces intracellular [Ca{sup 2+}] increases in human sperm even in the absence of extracellular Ca{sup 2+}. Using LysoTracker®, a fluorescent probe that selectively accumulates in acidic compartments, we identified two such stores in human sperm cells. Their acidic nature was further confirmed by the reduction in staining intensity observed upon inhibition of the endo-lysosomal proton pump with Bafilomycin, or after lysosomal bursting with glycyl-L-phenylalanine-2-naphthylamide. The selective fluorescent NAADP analog, Ned-19, stained the same subcellular regions as LysoTracker®, suggesting that these stores are the targets of NAADP action.

60 APPLIED LIFE SCIENCES↗

Miniaturized Multi-Band Antenna via Element Collocation

The resonant frequency of a microstrip patch antenna may be reduced through the addition of slots in the radiating element. Expanding upon this concept in favor of a significant reduction in the tuned width of the radiator, nearly 60% of the antenna metallization is removed, as seen in the top view of the antenna’s radiating element (shown in red, below, left). To facilitate an increase in the gain of the antenna, the radiator is suspended over the ground plane (green) by an air substrate at a height of 0.250" while being mechanically supported by 0.030" thick Rogers RO4003 laminate in the same profile as the element. Although the entire surface of the antenna (red) provides 2.45 GHz operation with insignificant negative effects on performance after material removal, the smaller square microstrip in the middle must be isolated from the additional aperture in order to afford higher frequency operation. A low insertion loss path centered at 2.45 GHz may simultaneously provide considerable attenuation at additional frequencies through the implementation of a series-parallel, resonant reactive path. However, an inductive reactance alone will not permit lower frequency energy to propagate across the intended discontinuity. To mitigate this, a capacitance is introduced in series with the inductor, generating a resonance at 2.45 GHz with minimum forward transmission loss. Four of these reactive pairs are placed between the coplanar elements as shown. Therefore, the aperture of the lower-frequency outer segment includes the smaller radiator while the higher frequency section is isolated from the additional material. In order to avoid cross-polarization losses due to the orientation of a transmitter or receiver in reference to the antenna, circular polarization is realized by a quadrature coupler for each collocated antenna as seen in the bottom view of the antenna (right). To generate electromagnetic radiation concentrically rotating about the direction of propagation, ideally one-half of the power must be delivered to the output of each branch with a phase shift of 90 degrees and identical amplitude. Due to this, each arm of the coupler is spaced λ/4 wavelength apart.

42 ENGINEERING↗

Ions Beams and Ferroelectric Plasma Sources

Near-perfect space-charge neutralization is required for the transverse compression of high perveance ion beams for ion-beam-driven warm dense matter experiments, such as the Neutralized Drift Compression eXperiment (NDCX). Neutralization can be accomplished by introducing a plasma in the beam path, which provides free electrons that compensate the positive space charge of the ion beam. In this thesis, charge neutralization of a 40~keV, perveance-dominated Ar$^+$ beam by a Ferroelectric Plasma Source (FEPS) is investigated. First, the parameters of the ion beam, such as divergence due to the extraction optics, charge neutralization fraction, and emittance were measured. The ion beam was propagated through the FEPS plasma, and the effects of charge neutralization were inferred from time-resolved measurements of the transverse beam profile. In addition, the dependence of FEPS plasma parameters on the configuration of the driving pulser circuit was studied to optimize pulser design. An ion accelerator was constructed that produced a 30-50~keV Ar$^+$ beam with pulse duration $<$300~$\mu$s and dimensionless perveance $Q$ up to 8$\times$10$^{-4}$. Transverse profile measurements 33~cm downstream of the ion source showed that the dependence of beam radius on $Q$ was consistent with space charge expansion. It was concluded that the beam was perveance-dominated with a charge neutralization fraction of approximately zero in the absence of neutralizing plasma. Since beam expansion occurred primarily due to space charge, the decrease in effective perveance due to neutralization by FEPS plasma can be inferred from the reduction in beam radius. Results on propagation of the ion beam through FEPS plasma demonstrate that after the FEPS is triggered, the beam radius decreases to its neutralized value in about 5~$\mu$s. The duration of neutralization was about 10~$\mu$s at a charging voltage $V_{FEPS}$~=~5.5~kV and 35~$\mu$s at $V_{FEPS}$~=~6.5~kV. With $V_{FEPS}$~=~6.5~kV, the transverse current density profile 33~cm downstream of the source had a Gaussian shape with $x_{rms}$=5~mm, which corresponds to a half-angle divergence of 0.87$^\circ$. The measurements show that near-perfect charge neutralization with FEPS can be attained. No loss of ion beam current was detected, indicating the absence of a neutral cloud in the region of beam propagation, which would cause beam loss to charge exchange collisions. This provides evidence in favor of using FEPS in a future Heavy Ion Fusion accelerator. The FEPS discharge was investigated based on current-voltage measurements in the pulser circuit. Different values of series resistance and storage capacitance in the pulser circuit were used. The charged particle current emitted by the FEPS into vacuum was measured from the difference in forward and return currents in the driving circuit. It was found that FEPS is an emitter of negative charge, and that electron current emission begins approximately 0.5~$\mu$s after the fast-rising high voltage pulse is applied and lasts for tens of $\mu$s. The value of the series resistance in the pulser circuit was varied to change the rise time of the voltage pulse; plasma density was expected to decrease with increasing values of resistance. However, the data showed that changing the resistance had no significant effect. The average charge emitted per shot depends strongly on the value of the storage capacitance. Lowering the capacitance from 141~nF to 47~nF resulted in a near-complete shut-off of charge emission, although the amplitude of the applied voltage pulse was as high, and rise time as short, as when high-density plasma was produced. Increasing the capacitance from 141~nF to 235~nF increased the average charge emitted per shot by a factor of$~$2.

ferroelectric plasma source↗

Investigating compositional effects of atomic layer deposition ternary dielectric Ti-Al-O on metal-insulator-semiconductor heterojunction capacitor structure for gate insulation of InAlN/GaN and AlGaN/GaN

Gate insulation/surface passivation in AlGaN/GaN and InAlN/GaN heterojunction field-effect transistors is a major concern for passivation of surface traps and reduction of gate leakage current. However, finding the most appropriate gate dielectric materials is challenging and often involves a compromise of the required properties such as dielectric constant, conduction/valence band-offsets, or thermal stability. Creating a ternary compound such as Ti-Al-O and tailoring its composition may result in a reasonably good gate material in terms of the said properties. To date, there is limited knowledge of the performance of ternary dielectric compounds on AlGaN/GaN and even less on InAlN/GaN. To approach this problem, the authors fabricated metal-insulator-semiconductor heterojunction (MISH) capacitors with ternary dielectrics Ti-Al-O of various compositions, deposited by atomic layer deposition (ALD). The film deposition was achieved by alternating cycles of TiO2 and Al2O3 using different ratios of ALD cycles. TiO2 was also deposited as a reference sample. The electrical characterization of the MISH capacitors shows an overall better performance of ternary compounds compared to the pure TiO2. The gate leakage current density decreases with increasing Al content, being similar to 2-3 orders of magnitude lower for a TiO2:Al2O3 cycle ratio of 2:1. Although the dielectric constant has the highest value of 79 for TiO2 and decreases with increasing the number of Al2O3 cycles, it is maintaining a relatively high value compared to an Al2O3 film. Capacitance voltage sweeps were also measured in order to characterize the interface trap density. A decreasing trend in the interface trap density was found while increasing Al content in the film. In conclusion, our study reveals that the desired high-kappa properties of TiO2 can be adequately maintained while improving other insulator performance factors. The ternary compounds may be an excellent choice as a gate material for both AlGaN/GaN and InAlN/GaN based devices.

Colon, Albert↗

Plasma Processing of SRF Cavities for the next Generation Of Particle Accelerators

The cost-effective production of high frequency accelerating fields are the foundation for the next generation of particle accelerators. The Ar/Cl2 plasma etching technology holds the promise to yield a major reduction in cavity preparation costs. Plasma-based dry niobium surface treatment provides an excellent opportunity to remove bulk niobium, eliminate surface imperfections, increase cavity quality factor, and bring accelerating fields to higher levels. At the same time, the developed technology will be more environmentally friendly than the hydrogen fluoride-based wet etching technology. Plasma etching of inner surfaces of standard multi-cell SRF cavities is the main goal of this research in order to eliminate contaminants, including niobium oxides, in the penetration depth region. Successful plasma processing of multi-cell cavities will establish this method as a viable technique in the quest for more efficient components of next generation particle accelerators. In this project the single-cell pill box cavity plasma etching system is developed and etching conditions are determined. An actual single cell SRF cavity (1497 MHz) is plasma etched based on the pill box cavity results. The first RF test of this plasma etched cavity at cryogenic temperature is obtained. The system can also be used for other surface modifications, including tailoring niobium surface properties, surface passivation or nitriding for better performance of SRF cavities. The results of this plasma processing technology may be applied to most of the current SRF cavity fabrication projects. In the course of this project it has been demonstrated that a capacitively coupled radio-frequency discharge can be successfully used for etching curved niobium surfaces, in particular the inner walls of SRF cavities. The results could also be applicable to the inner or concave surfaces of any 3D structure other than an SRF cavity.

43 PARTICLE ACCELERATORS↗

Frequency analysis and resonant operation for efficient capacitive deionization

Capacitive deionization (CDI) performance metrics can vary widely with operating methods. Conventional CDI operating methods such as constant current and constant voltage show advantages in either energy or salt removal performance, but not both. We here develop a theory around and experimentally demonstrate a new operation for CDI that uses sinusoidal forcing voltage (or sinusoidal current). We use a dynamic system modeling approach, and quantify the frequency response (amplitude and phase) of CDI effluent concentration. Using a wide range of operating conditions, we demonstrate that CDI can be modeled as a linear time invariant system. We validate this model with experiments, and show that a sinusoid voltage operation can simultaneously achieve high salt removal and strong energy performance, thus very likely making it superior to other conventional operating methods. Based on the underlying coupled phenomena of electrical charge (and ionic) transfer with bulk advection in CDI, we derive and validate experimentally the concept of using sinusoidal voltage forcing functions to achieve resonance-type operation for CDI. Despite the complexities of the system, we find a simple relation for the resonant time scale: the resonant time period (frequency) is proportional (inversely proportional) to the geometric mean of the flow residence time and the electrical (RC) charging time. Operation at resonance implies the optimal balance between absolute amount of salt removed (in moles) and dilution (depending on the feed volume processed), thus resulting in the maximum average concentration reduction for the desalinated water. We further develop our model to generalize the resonant time-scale operation, and provide responses for square and triangular voltage waveforms as two examples. To this end, we develop a general tool that uses Fourier analysis to construct CDI effluent dynamics for arbitrary input waveforms. Using this tool, we show that most of the salt removal (~95%) for square and triangular voltage forcing waveforms is achieved by the fundamental Fourier (sinusoidal) mode. The frequency of higher Fourier modes precludes high flow efficiency for these modes, so these modes consume additional energy for minimal additional salt removed. This deficiency of higher frequency modes further highlights the advantage of DC-offset sinusoidal forcing for CDI operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗