Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Nonlinear size dependent analysis and effectiveness of nanocrystalline micro/nanogyroscopes

Vibratory micro/nanogyroscopes made of nanocrystalline silicon have a complex microstructure consisting of grains, voids, and interface material phases. Given that the length scale of such inertial sensors is close to the size of the grains themselves, classical continuum mechanics theories are no longer adequate to accurately model the dynamic behaviors of these sensors. In this work, the couple stress and surface elasticity are incorporated to the governing equations of an electrically-actuated, amplitude-based, capacitive sensing cantilever gyroscope to obtain a comprehensive model of the nano-system. Then, the impact of the size dependent effects on the nonlinear dynamic behavior of the gyroscope is investigated by studying its performance for gyroscopes ranging in size from the micro-to the nano-scale. The present numerical study shows that the additional stiffness contributions from the couple stress and surface elasticity and changes in scale cause significant changes in the frequency response, nonlinear behaviors, and sensitivity of the gyroscope to the rotation rates. Furthermore, this numerical analysis demonstrates the importance of accounting for size dependent effects for micro/nanogyroscopes in order to avoid any deterioration of the effectiveness of the gyroscope operability.

42 ENGINEERING↗

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Non-contact current and voltage sensor

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

47 OTHER INSTRUMENTATION↗

Non-contact current and voltage sensing method using a clamshell housing and a ferrite cylinder

A method of measurement using a detachable current and voltage sensor provides an isolated and convenient technique for to measuring current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Metal oxide coating of carbon supports for supercapacitor applications.

The global market for wireless sensor networks in 2010 will be valued close to $10 B, or 200 M units. TPL, Inc. is a small Albuquerque based business that has positioned itself to be a leader in providing uninterruptible power supplies in this growing market with projected revenues expected to exceed $26 M in 5 years. This project focused on improving TPL, Inc.'s patent-pending EnerPak{trademark} device which converts small amounts of energy from the environment (e.g., vibrations, light or temperature differences) into electrical energy that can be used to charge small energy storage devices. A critical component of the EnerPak{trademark} is the supercapacitor that handles high power delivery for wireless communications; however, optimization and miniaturization of this critical component is required. This proposal aimed to produce prototype microsupercapacitors through the integration of novel materials and fabrication processes developed at New Mexico Technology Research Collaborative (NMTRC) member institutions. In particular, we focused on developing novel ruthenium oxide nanomaterials and placed them into carbon supports to significantly increase the energy density of the supercapacitor. These improvements were expected to reduce maintenance costs and expand the utility of the TPL, Inc.'s device, enabling New Mexico to become the leader in the growing global wireless power supply market. By dominating this niche, new customers were expected to be attracted to TPL, Inc. yielding new technical opportunities and increased job opportunities for New Mexico.

25 ENERGY STORAGE↗

Electroanalytical Investigation of the Electrode–Electrolyte Interface of Quaternary Ammonium Ionic Liquids: Impact of Alkyl Chain Length and Ether Functionality

The influence of ionic associations and potential-dependent interactions on the electrode–electrolyte interfacial structure of ionic liquids (ILs) is studied by electrochemical impedance spectroscopy (EIS) and surface-enhanced Raman spectroscopy (SERS) for a variety of asymmetric quaternary ammonium ILs. Specifically, the impact of cation alkyl chain length (C = 4, 8 and 16) and ether functionality on the interfacial structuring of ILs at the glassy carbon electrode surface is examined. Ammonium cations with alkyl chain length of 8 and 16 carbons are found to stabilize the formation of the bis(trifluorosulfonyl)imide, [TFSI], anion dense Stern layer at positive electrode potentials leading to larger capacitances. The longer alkyl chain of the cation is believed to screen the ion–ion repulsion among the anions by intruding into the interfacial anion layer. SERS suggests the presence of carbon-containing rings at the interface at both positive and negative electrode potentials, which can be explained by the buckling of the long alkyl chains. Inclusion of an ether functionality allowed for more symmetry in the camel-shaped potential-dependent differential capacitance curves, suggesting similar excess ion density at both positive and negative potentials. This work contributes to understanding and predicting the interfacial electrode capacitance in ILs by understanding the balance of ionic interactions and the associated repulsions at electrode–electrolyte interfaces that are pertinent to electrochemical energy storage, electrocatalysis, and electrochemical sensors.

25 ENERGY STORAGE↗

Carrier behavior in special multilayer device composed of different transition metal oxide-based intermediate connectors

The impact of illumination on the connection part of the tandem organic light-emitting diodes was studied by using a special organic multilayer sample consisted of two organic active layers coupled with different transition metal oxide (TMO)-based intermediate connectors (ICs). Through measuring the current density-voltage characteristic, interfacial electronic structures, and capacitance-voltage characteristic, we observe an unsymmetrical phenomenon in current density-voltage and capacitance-voltage curves of Mg:Alq{sub 3}/MoO{sub 3} and MoO{sub 3} composed devices, which was induced by the charge spouting zone near the ICs region and the recombination state in the MoO{sub 3} layer. Moreover, Mg:Alq{sub 3}/MoO{sub 3} composed device displays a photovoltaic effect and the V{sub oc} shifts to forward bias under illumination. Our results demonstrate that the TMO-based IC structure coupled with photovoltaic effect can be a good approach for the study of photodetector, light sensor, and so on.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction

We describe the design, construction, calibration, and two different applications of a miniature capacitance dilatometer. The device is suitable for thermal expansion and magnetostriction measurements from 300 K down to about 25 mK, with a resolution of 0.02 A at low temperatures. The main body of the dilatometer is fabricated from a single block of a Be-Cu alloy by electrical discharge milling. This creates an extremely compact high-resolution measuring cell. We have successfully tested and operated dilatometers of this new type with the commonly used physical property measurement system by quantum design, as well as with several other cryogenic refrigeration systems down to 25 mK and in magnetic fields up to 20 T. Here, the capacitance is measured with a commercially available capacitance bridge. Using a piezoelectric rotator from Attocube Systems, the cell can be rotated at T= 25 mK inside of an inner vacuum chamber of 40 mm diameter. The miniaturized design for the one-axis rotation setup allows a rotation of 360 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A single electron transistor charge sensor in strong rf fields

We measure the charge sensitivity, S e , of a single electron transistor (SET) in the presence of strong (V rf ~ e/C g ) spurious radio frequency (rf) signals at frequencies up to 50 MHz, where C g is the gate capacitance. Although S e appears to degrade when exposed to V rf , we find that broadening of conduction peaks is largely due to the measurement technique and show that S e is maintained even with strong V rf present. We show cancellation of a known V rf signal at 1 MHz, demonstrating that a stable bias point in the presence of rf signals is possible.

47 OTHER INSTRUMENTATION↗

Thermal and radiation response of 4H–SiC Schottky diodes with direct-write electrical contacts

In this work, a high-sensitivity 4H–SiC temperature sensor and an alpha detector have been fabricated using additively printed metal contacts. The surface morphology and electrical conductivity of the printed electrodes were established prior to Schottky diode development. 4H–SiC Schottky diodes with direct-write printed silver contacts on the 5 μ m-thick epilayer on 4H–SiC were characterized electrically in terms of the forward and reverse current–voltage and high-frequency capacitance–voltage characteristics. Furthermore, the turn-on voltage of the Schottky diodes, as established from the forward current–voltage characteristics measured up to a temperature of 400 °C, showed a linear temperature dependence. Schottky diodes with direct-write printed Ag electrodes were able to measure alpha particles emitted from Americium-241. The high temperature and radiation response of the Schottky diodes show their suitability for multi-modal sensor fusion on the 4H–SiC platform for harsh environment applications.

42 ENGINEERING↗

Gamma Radiation Monitoring Through Thin Film of ClAlPc Doped With TiO{sub 2}

Chloroaluminum phthalocyanine (ClAlPc) synthesized by adopting focused microwave synthesis approach was doped with nanocrystalline TiO{sub 2} (5% by weight) and developed into the thin film sandwiched device having ITO/ClAlPc:TiO{sub 2}/Ag Schottky configuration by spin coating technique covering 1 cm{sup 2} as an active area. The so fabricated device having initial dark current of the order of 0.2 5 m A was exposed to variable dose of gamma radiation ranging from lcGy to 10 Gy at a dose rate of 1 Gy/hour. The experimental observation reveals the generation of localized traps leading to structural disorder within the solid material. Doping with TiO{sub 2} enhances the surface area of the film which in tern improves sensitivity of device to wider dose rage. Exposure of the device to variable dose of gamma radiation imparts decrease in forward bias current and capacitance characteristics with increase in radiation dose. Also, absorbance characteristics of the Al Pc: TiO{sub 2} was analyzed before and after exposure to radiation which reveals that absorbance decreases with radiation dose leading to decrease in optical band gap.

36 MATERIALS SCIENCE↗

Robustness and printed sensor qualification

A limiting factor of additive manufactured (AM) sensors for in-pile applications is the development of appropriate interconnection and packaging strategies that can maintain reliable performance in extreme environments. Failure mechanisms in these harsh conditions could include, but not limited to, materials interaction (i.e., intermetallic formation) and coefficient of thermal expansion (CTE) mismatch between the individual components of the sensors. To mitigate premature failure and enable the successful sustained operation of AM sensors, non-destructive qualification tests are used as an intermediate process control step used for verifying robustness and reliability of the sensor before they are deployed. A materials system of interest is the use of barium strontium titanium oxide (BST) films on stainless steel 316L (SS316L) substrate. Due to BST’s high dielectric constant and tunable dielectric properties, there is an interest for its application as an insulation/encapsulation layer for capacitive strain gauges when printed on structural materials. Previous work on the BST/SS316L material system, however, showed that the BST cracks when exposed to temperatures up to 600 °C due to CTE mismatch between the printed BST film and the metallic substrate. When comparing different fabrication techniques, less surface cracking was observed in the samples that deposited thinner (i.e., 2-20 μm) than samples that were thicker (i.e., 135 µm – 300 µm). The objective of this report is to establish a qualification process that will determine and address any challenges (i.e., mechanical failure of thick prints) of the AM sensor prior to its application in experimental tests. To demonstrate the qualification process in this report, laser spallation and uniaxial tensile tests using dynamic and quasi-static loading, respectively, will be discussed.

36 - MATERIALS SCIENCE↗

Large Area Picosecond Photodetector (LAPPD TM ) - Pilot production and development status

Here, we discuss performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD (TM)) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate (MCP) based large area picosecond photodetector, capable of imaging with single-photon sensitivity at high spatial and temporal resolutions in a hermetic package. The LAPPD has an active area of 350 square centimeters in an all-glass hermetic package with a fused silica window and bottom plate and sidewalls made of borosilicate float glass. Signals are generated by a bi-alkali Na 2 KSb photocathode and amplified with a stacked chevron pair of MCPs produced by applying resistive and emissive atomic layer deposition coatings to glass capillary array (GCA) substrates. Signals are collected on RF stripline anodes applied to the bottom plates which exit the detector via pin-free hermetic seals under the side walls. LAPPD test and performance results for product produced and delivered to early adopter customers during the first half of 2018 are reviewed. These results include electron gains ≥ 7.5 x 10 6 @ 850/950 V (entry/exit MCP), low dark noise rates (22 Cts/s/cm 2 ), single photoelectron (PE) timing resolution of 64 picoseconds RMS, and single photoelectron spatial resolution along and across strips of 2.8 mm and 1.3 mm RMS respectively. Many of these devices also had very high QE photocathodes that were uniform over the full 195 mm x 195 mm window active area (LAPPD #15 QE% @ 365 nm Max/Avg/Min = 25.8/22.3 ± 3/15.7). An update is additionally provided of developments that enable capacitive signal coupling from the detector to application specific pads or stripline readout patterns deployed on printed circuit boards positioned beneath the file, outside of the vacuum package. We conclude with examples of how sensors offering picosecond timing, in diverse applications can bring transformative change to detector technology and applications in future experiments.

47 OTHER INSTRUMENTATION↗

Sensor Characteristics Reference Guide

The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information.

Acoustic Energy Generators↗

Recent advances in MoS{sub 2} nanostructured materials for energy and environmental applications – A review

Molybdenum disulfide (MoS{sub 2}), a layered transition metal dichalcogenide with an analogous structure to graphene, has attracted enormous attention worldwide owing to its use in a variety of applications such as energy storage, energy conversion, environmental remediation and sensors. MoS{sub 2} and graphene have almost similar functional properties such as high charge carrier transport, high wear resistance and good mechanical strength and friction. However, MoS{sub 2} is advantageous over graphene due to its low-cost, abundancy, tailorable morphologies and tuneable band gap with good visible light absorption properties. In this review, we have focussed mainly on recent advances in MoS{sub 2} nanostructured materials for the applications in the broad area of energy and environment. Special attention has been paid to their applications in dye-sensitized solar cells, supercapacitor, Li-ion battery, hydrogen evolution reaction, photocatalysis for the degradation of organic pollutants, chemical/bio sensors and gas sensors. Finally, the challenges to design MoS{sub 2} nanostructures suitable for energy and environmental applications are also highlighted. - Highlights: • Applications of MoS{sub 2} nanostructures towards energy, environmental remediation and sensors were summarized. • Recent advances in the development of MoS{sub 2} nanostructured materials were systematically investigated. • Wide range of energy applications including DSSCs, supercapacitors, Li-ion batteries and HER were reviewed. • Key challenges and optimization of structure for superior performance associated with MoS{sub 2} nanostructures were discussed. • Advances of environmental remediation based on MoS{sub 2} nanostructures were significantly highlighted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of MEMS based pyroelectric thermal energy harvesters

The efficient conversion of waste thermal energy into electrical energy is of considerable interest due to the huge sources of low-grade thermal energy available in technologically advanced societies. Our group at the Oak Ridge National Laboratory (ORNL) is developing a new type of high efficiency thermal waste heat energy converter that can be used to actively cool electronic devices, concentrated photovoltaic solar cells, computers and large waste heat producing systems, while generating electricity that can be used to power remote monitoring sensor systems, or recycled to provide electrical power. The energy harvester is a temperature cycled pyroelectric thermal-to-electrical energy harvester that can be used to generate electrical energy from thermal waste streams with temperature gradients of only a few degrees. The approach uses a resonantly driven pyroelectric capacitive bimorph cantilever structure that potentially has energy conversion efficiencies several times those of any previously demonstrated pyroelectric or thermoelectric thermal energy harvesters. The goals of this effort are to demonstrate the feasibility of fabricating high conversion efficiency MEMS based pyroelectric energy converters that can be fabricated into scalable arrays using well known microscale fabrication techniques and materials. These fabrication efforts are supported by detailed modeling studies of the pyroelectric energy converter structures to demonstrate the energy conversion efficiencies and electrical energy generation capabilities of these energy converters. This paper reports on the modeling, fabrication and testing of test structures and single element devices that demonstrate the potential of this technology for the development of high efficiency thermal-to-electrical energy harvesters.

14 SOLAR ENERGY↗