Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Multifunctional RF limiting amplifier

Multifunctional RF limiting amplifiers having various configurations and functions are disclosed. In a first configuration, the RF limiting amplifier includes an active load output circuit that allows one to adjust the output impedance based upon the anticipated connected load impedance. In a second configuration, the RF limiting amplifier includes a pair of emitter-followers to buffer the output of a first stage, allowing the RF limiting amplifier to drive one or more second stages. A third configuration includes a pair of RF limiting amplifiers with their outputs mixed to implement a down conversion function. The third configuration may be used to drive dual SAW resonators for detecting the presence of biological or chemical agents. The RF limiting amplifier may be implemented in either bipolar junction transistors or CMOS transistors.

Wessendorf, Kurt O.↗

Characterization of Humanized Mouse Model of Organophosphate Poisoning and Detection of Countermeasures via MALDI-MSI

Organophosphoate (OP) chemicals are known to inhibit the enzyme acetylcholinesterase (AChE). Studying OP poisoning is difficult because common small animal research models have serum carboxylesterase, which contributes to animals’ resistance to OP poisoning. Historically, guinea pigs have been used for this research; however, a novel genetically modified mouse strain (KIKO) was developed with nonfunctional serum carboxylase (Es1 KO) and an altered acetylcholinesterase (AChE) gene, which expresses the amino acid sequence of the human form of the same protein (AChE KI). KIKO mice were injected with 1xLD50 of an OP nerve agent or vehicle control with or without atropine. After one to three minutes, animals were injected with 35 mg/kg of the currently fielded Reactivator countermeasure for OP poisoning. Postmortem brains were imaged on a Bruker RapifleX ToF/ToF instrument. Data confirmed the presence of increased acetylcholine in OP-exposed animals, regardless of treatment or atropine status. More interestingly, we detected a small amount of Reactivator within the brain of both exposed and unexposed animals; it is currently debated if reactivators can cross the blood–brain barrier. Further, we were able to simultaneously image acetylcholine, the primary affected neurotransmitter, as well as determine the location of both Reactivator and acetylcholine in the brain. This study, which utilized sensitive MALDI-MSI methods, characterized KIKO mice as a functional model for OP countermeasure development.

2-PAM↗

Personal and environmental predictors of polycyclic aromatic hydrocarbon exposure identified through repeated silicone wristband sampling

This study integrates quantitative data on personal exposure to polycyclic aromatic hydrocarbons (PAHs) in 162 silicone wristbands with demographics, behavioral information, and housing characteristics to explore contributions to residential exposure in a superfund-adjacent community over the course of a year. Forty-six residents completed questionnaires and wore silicone wristbands as personal passive samplers for seven consecutive days on up to four separate occasions in alternating months between November 2022 and June 2023. It was hypothesized that individual behaviors and housing characteristics are sources of dependence and correlation between personal PAH exposures. 50 PAHs were detected at least once, 17 of which were alkylated PAHs. Exposure to PAHs of similar molecular weight was often correlated, notably between naphthalenes (2-rings) and higher molecular weight PAHs (3 or more rings). Generalized linear mixed models identified flooring type, participant age, and sampling month as important predictors of increased PAH exposure, and flooring type, and use of wood stoves or heavy machinery as predictors of increased naphthalene exposure relative to higher molecular weight PAHs. Individual chemical models based on concentration data and detection frequencies corroborated these findings across multiple PAHs. We demonstrate that personal exposure is not static and the degree of variability in personal exposure is individual. Hence, identification of influential exposure factors through repeated measures of chemical exposure and characterization of variability in personal exposure as performed in this study, is important in the development of exposure mitigation strategies.

Bonner, Emily↗

Kimberlina 1.2 Velocity Models and Seismic Data

Kimberlina 1.2 Velocity model and synthetic seismic data, produced in collaboration of teams at the National Energy Technology Laboratory, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory through the National Risk Assessment Partnership. Data is associated with the following publication: Zheng Zhou, Youzuo Lin, Zhongping Zhang, Yue Wu, Zan Wang, Robert Dilmore, and George Guthrie, "A Data-Driven CO2 Leakage Detection Using Seismic Data and Spatial-Temporal Densely Connected Convolutional Neural Networks," International Journal of Greenhouse Gas Control, Vol 90, 2019. The Kimberlina 1.2 Velocity models were produced by Zan Wang, Robert Dilmore, William Harbert, and Lianjie Huang at NETL. The following citations are directly related to the creation of the velocity models: Wang, Z. Harbert, W., Dilmore, R., Huang, L. Modeling of time-lapse seismic monitoring using CO2 leakage simulations for a model CO2 storage site with realistic geology: Application in assessment of early leak-detection capabilities. International Journal of Greenhouse Gas Control. V. 76, September 2018, Pages 39-52. https://doi.org/10.1016/j.ijggc.2018.06.011 Wang, Z., Dilmore, R., Harbert, W. Inferring CO2 saturation from synthetic surface seismic and downhole monitoring data using machine learning for leakage detection at CO2 sequestration sites. International Journal of Greenhouse Gas Control, V. 100, September 2020. https://doi.org/10.1016/j.ijggc.2020.103115 The velocity models were built based on the Kimberlina 1.2 aquifer impact data which is associated with the following publications: Buscheck, T.A., Mansoor, K., Yang, X., Wainwright, H., and Carroll, S. (2019). Downhole pressure and chemical monitoring for CO2 and brine leak detection in aquifers above a CO2 storage reservoir. International Journal of Greenhouse Gas Control. 91. 102812. 10.1016/j.ijggc.2019.102812. Xianjin Yang, Thomas A. Buscheck, Kayyum Mansoor, Zan Wang, Kai Gao, Lianjie Huang, Delphine Appriou, Susan A. Carroll, Assessment of geophysical monitoring methods for detection of brine and CO2 leakage in drinking water aquifers, International Journal of Greenhouse Gas Control, Volume 90, 2019, 102803, ISSN 1750-5836, https://doi.org/10.1016/j.ijggc.2019.102803 The synthetic seismic data was produced by Youzuo Lin and team at LANL, and are associated with the following citations: Jordan, P. D., and J. L. Wagoner. Characterizing Construction of Existing Wells to a CO2 Storage Target: The Kimberlina Site, California. Zheng Zhou, Youzuo Lin, Zhongping Zhang, Yue Wu, Zan Wang, Robert Dilmore, and George Guthrie, "A Data-Driven CO2 Leakage Detection Using Seismic Data and Spatial-Temporal Densely Connected Convolutional Neural Networks," International Journal of Greenhouse Gas Control, Vol 90, 2019.

CO2 Leakage↗

Raman Spectroscopy to Detect and Measure NOW Pheromones

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can effectively help reducing crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural ones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes and how those evolve from emission points, especially across large blocks and at plot borders.

47 OTHER INSTRUMENTATION↗

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

Geometrical and chemical effects on the electrochemistry of single-wall carbon nanotube (SWCNT) network electrodes

Single-wall carbon nanotube (SWCNT) network is a promising electrode material for bio detection. Unfortunately, the associations between their physical as well as chemical properties and observed electrochemical performance are not known. This hinders any systematic optimization of the network properties towards specific analytes. Here we present a consistent physicochemical and electrochemical characterization of differently treated SWCNT networks. The results unambiguously show that (i) even if the electrochemical properties of different electrodes are practically identical when assessed by surface insensitive outer sphere redox (OSR) probes their behavior with inner sphere redox (ISR) probes can be drastically different. Further, (ii) the choice of the modification method (structural, chemical, electrochemical) heavily depends on nature of the target analyte, which are typically ISR probes. Although, (iii) chemical changes in the carbon phase appeared to be minor, effects of different treatments on oxidation states of Fe appeared to have a strong effect on the electrochemical performance of the networks in the case of ISR probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the morphology and chemical activity of model ZrO x /Au (111) catalysts for CO 2 hydrogenation

In this study, the growth of ZrO x on Au (111) was investigated using scanning tunneling microscopy (STM) and synchrotron-based ambient pressure X-ray photoelectron spectroscopy (AP-XPS). Nanostructures of ZrO x (x= 1,2) at the sub-monolayer (≤ 0.3 ML) level were prepared by vapor depositing Zr metal onto Au (111) followed by oxidation with O 2 or CO 2 . At low coverages of the admetal (< 0.05 ML), the formed ZrO x nanostructures were dispersed randomly on the terraces and steps of the Au(111) substrate. Strong oxide-metal interactions prevented the formation of islands of zirconia. The ZrO x nanostructures displayed a reactivity towards CO 2 and H 2 not seen for bulk zirconia. C 1 s AP-XPS results indicated that CO 2 molecules adsorbed on Zr/ZrO x /Au(111) surfaces could undergo partial decomposition on Zr (CO 2 , gas → CO gas + O ads ), or react with oxygen sites from ZrO x to yield carbonates (Zr-CO 3, ads ). Further, after exposing ZrO 2 /Au (111) surfaces to 1:3 mixtures of CO 2 :H 2 , the formation of HCOO, CO 3 , and CH 3 O was detected in AP-XP spectra. These chemical species decomposed at temperatures in the range of 400-600 K, making them possible reaction intermediates for methanol synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detecting onset of lithium plating during fast charging of Li-ion batteries using operando electrochemical impedance spectroscopy

Electrochemical plating of Li metal on the graphite electrode is the key limitation behind slow charging times of Li-ion batteries (LIBs) in electric vehicles (EVs). Currently, electrochemical methods to detect the onset of Li plating while a battery is fast charging are sparse. In this study, we use operando electrochemical impedance spectroscopy to reliably detect the onset of Li plating on graphite electrodes in three-electrode LIBs. An increase in the graphite solid-electrolyte interface (SEI) resistance indicates that Li plating has occurred. By cross-validating with a highly sensitive ex situ chemical titration, we determine that this technique can detect very small amounts of plated Li (<0.6% of the graphite electrode's capacity). We also offer physical explanations for the observed impedance behavior. Finally, we show that this technique can be applied to standard two-electrode LIB systems, making the method an important step toward safely implementing fast charging protocols for LIBs in EVs.

25 ENERGY STORAGE↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Chemistry↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Arasteh, Kourosh [Lawrence Livermore National Labo↗

Enhanced ZIF-8-enabled colorimetric CO 2 sensing through dye-precursor synthesis

The accumulation of carbon dioxide (CO 2 ) within enclosed spaces, along with volatile organic compounds, under certain humidity, temperature, and ventilation conditions is associated with detrimental human health symptoms such as fatigue. Color-based chemical sensing is a promising approach to detect CO 2 levels relevant to indoor air quality through producing fast, quantifiable output visible to the naked eye. In a prior work, a colorimetric gas sensor was fabricated through synthesizing the metal-organic framework, ZIF-8, as the adsorbent, followed by post-synthetic mixing with a dye, phenol red (PSP), and primary amine, ethylenediamine (ED). While this sensor (termed PSP-ED/ZIF-8) maintained its structural integrity in atmospheric conditions and exhibited an increasing fuchsia-to-yellow color change with increasing CO 2 levels in dry environment, the colorimetric response greatly suffered in the presence of humid CO 2 . Here in this work, a significantly improved colorimetric CO 2 sensor (referred to as ED/PSP:ZIF-8) is accomplished through directly incorporating phenol red in the ZIF-8 metal and linker precursor solutions and then blending with ethylenediamine. MATLAB-generated color distributions and in-situ ultraviolet-visible (UV-Vis) spectroscopic studies quantitatively demonstrate an enhanced colorimetric gas response of ED/PSP:ZIF-8 compared to that of PSP-ED/ZIF-8 across an important range of CO 2 for indoor air quality monitoring (500 – 3500 ppm) and across a range of humidity. The new sensor also exhibits high selectivity to CO 2 compared to select volatile organic compounds, such as acetone and ethanol, which contribute to human health symptoms experienced indoors. The enhanced performance is attributed to the proposed incorporation of phenol red within ZIF-8, while maintaining the chemical stability of the MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous measurements of volatile gases as detection of algae crop health

Wide adoption of algae cultivation to produce environmentally sustainable biofuels and fine chemicals is currently hampered by large losses (10 to 30%) incurred by grazer infections. We show the usage of real-time chemical ionization mass spectrometry to rapidly identify gaseous indicators of grazer infections in cyanobacteria cultures. Grazing was detected significantly faster (up to 3 d) using real-time mass spectrometry than the current methods of microscopy and qPCR. By employing this technology, cultivators may be empowered to treat grazer infestations sooner, thereby protecting the crop and enhancing profitability.

09 BIOMASS FUELS↗

Single nuclear spin detection and control in a van der Waals material

Optically active spin defects in solids are leading candidates for quantum sensing and quantum networking. Recently, single spin defects were discovered in hexagonal boron nitride (hBN), a layered van der Waals (vdW) material. Owing to its two-dimensional structure, hBN allows spin defects to be positioned closer to target samples than in three-dimensional crystals, making it ideal for atomic-scale quantum sensing, including nuclear magnetic resonance (NMR) of single molecules. However, the chemical structures of these defects remain unknown and detecting a single nuclear spin with a hBN spin defect has been elusive. Here we report the creation of single spin defects in hBN using 13 C ion implantation and the identification of three distinct defect types based on hyperfine interactions. We observed both S = 1/2 and S = 1 spin states within a single hBN spin defect. We demonstrated atomic-scale NMR and coherent control of individual nuclear spins in a vdW material, with a π-gate fidelity up to 99.75% at room temperature. By comparing experimental results with density functional theory (DFT) calculations, we propose chemical structures for these spin defects. Our work advances the understanding of single spin defects in hBN and provides a pathway to enhance quantum sensing using hBN spin defects with nuclear spins as quantum memories.

Quantum metrology↗

Galactic ArchaeoLogIcaL ExcavatiOns (GALILEO) II. t-SNE portrait of local fossil relics and structures

Based on high-quality Apache Point Observatory Galactic Evolution Experiment (APOGEE) DR17 and Gaia DR3 data for 1742 red giants stars within 5 kpc of the Sun and not rotating with the Galactic disk (V φ < 100 km s -1 ), we used the nonlinear technique of unsupervised analysis t-Distributed Stochastic Neighbor Embedding (t-SNE) to detect coherent structures in the space of ten chemical-abundance ratios: [Fe/H], [O/Fe], [Mg/Fe], [Si/Fe], [Ca/Fe], [C/Fe], [N/Fe], [Al/Fe], [Mn/Fe], and [Ni/Fe]. Additionally, we obtained orbital parameters for each star using the nonaxisymmetric gravitational potential GravPot16. Seven structures are detected, including Splash, Gaia-Sausage-Enceladus (GSE), the high-α heated-disk population, N-C-O peculiar stars, and inner disk-like stars, plus two other groups that did not match anything previously reported in the literature, here named Galileo 5 and Galileo 6 (G5 and G6). These two groups overlap with Splash in [Fe/H], with G5 having a lower metallicity than G6, and they are both between GSE and Splash in the [Mg/Mn] versus [Al/Fe] plane, with G5 being in the α-rich in situ locus and G6 on the border of the α-poor in situ one. Nonetheless, their low [Ni/Fe] hints at a possible ex situ origin. Their orbital energy distributions are between Splash and GSE, with G5 being slightly more energetic than G6. We verified the robustness of all the obtained groups by exploring a large range of t-SNE parameters, applying it to various subsets of data, and also measuring the effect of abundance errors through Monte Carlo tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanoscale Examination of Chemical and Enzymatic Degradation of Plant Cell Walls

Lignocellulosic materials present the largest source of biomass for biotechnology and green energy. This study aimed at better understanding the cell wall disintegration mechanisms relevant for the biochemical conversion of biomass to carbohydrates. Herein, we examined nanoscale changes in cell wall structure and composition upon industrially relevant chemical and enzymatic treatments to achieve the desired level of breakdown. One treatment involved hydrogen peroxide and acetic acid to remove lignin. Another modification used the cellulase enzyme for cell wall degradation. Band excitation contact resonance atomic force microscopy was used to visualize and mechanically characterize cell wall layers. After cellulase treatments, we detected microcracks across the cell wall. Wet-chemical, Fourier-transform infrared and Raman spectroscopic analyses confirmed the removal of lignin and extractives through acid bleaching, while the enzymatic treatment minimally affected the biopolymer composition. Delignification resulted in cell wall delamination and reduced stiffness. In conclusion, X-ray diffraction revealed changes in cellulose structure and crystallinity.

Soini, Steven A. [Florida Atlantic Univ., Boca Rat↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗